Hydrosense HSCP
Water Leak Detection Panel
User Manual
Man-1136
Issue 01 April 2010
Alarm condition
General alarm indicator lights and zonal alarm indicators flash. Buzzer pulses rapidly.
Carry Out
investigation
procedure
Fault condition
General fault indicator lights and specific fault indicators flash. Buzzer sounds continuously.
Call
maintenance
engineer
Man-1136_Hydrosense_HSCP_User_01
Page 2 of 6
Disabled condition
General disablement indicator and specific fault indicator lit continuously.
Maintain
vigilance
during
disablement
conditions
Test condition
Test indicator and specific fault indicator lit continuously.
Ensure
system is
returned to
normal when
testing is
finished
Man-1136_Hydrosense_HSCP_User_01
Page 3 of 6
How To
Silence buzzer
Do This
Comments
Display
Alarm/Fault
Buzzer Silenced
Alarm/Fault
Buzzer Silenced
Test lamps
Press button
Lamp
Test
Buzzer sounds whilst
button is pressed
All lamps on
Press button
Enable buttons
(Only Alarm/Fault
warning Silence and
Lamp Test buttons are
operable without
turning enable key)
Enable
Control
Buzzer beeps twice
every few seconds
Turn key
Silence alarms
Silence/Sound
Alarm
Sound alarms
Press button
Silence/Sound
Alarm
Alarm/Fault
Buzzer Silenced
Buzzer pulses rapidly
Alarm
Press button
Reset
Ensure source of
alarm event is cleared
before resetting
Reset
Press button
Disable a zone step 1
Mode
Press button
First display
Select
Zone 5 for example
Disable a zone step 2
Disable a zone step 3
Press button to
scroll zones
Zone 5
Enter
Alarm in Zone
5
6
7
Zone Fault
Press button
Zone 5 fault LED lit
Man-1136_Hydrosense_HSCP_User_01
Page 4 of 6
General
Disablement
Dot flashes to indicate
disablement
How To
Do This
Comments
Display
Mode
Put a zone into test
mode step 1
Press button
Select
First display
Press button to
scroll zone
Zone 5
Zone 5 for example
Put a zone into test
mode step 2
Put a zone into test
mode step 3
Alarm in Zone
Enter
1
2
3
Zone Fault
Zone 1 fault LED lit
Press button
General
Disablement
Dot flashes to indicate
test mode
Mode
Enable a zone step 1
Press button to
display disablements
First display
Select
Flashing dot indicates
zone is disabled
Enable a zone step 2
Enable a zone step 3
Press button to
scroll zones
Zone 5
Enter
Alarm in Zone
5
Press button to
enable zone
6
7
Zone Fault
General
Disablement
General disablement
indicator extinguishes
Zone 5 LED extinguishes
Mode
Exit test mode step 1
First display
Press button
Select
Flashing dot indicates
zone is in test mode
Exit test mode step 2
Press button to
scroll zones
Exit test mode step 3
Zone 5
Alarm in Zone
Enter
1
Press button to
exit test mode
Man-1136_Hydrosense_HSCP_User_01
2
3
Zone Fault
Zone 1 flt LED extinguishes
Page 5 of 6
Test Mode On
Test mode LED
extinguishes
How To
Do This
Display
Comments
Mode
Disable sounders
step 1
Press button till
db is displayed
Disable sounders
step 2
Enter
Dot flashes to indicate
bells disabled.
General disablement
and Sounder
Fault/Disablement
indicators lit
Press button
Mode
Flashing dot indicates
bells disabled.
Enable sounders
step 1
Press button till
db is displayed
Enter
Dot stops flashing to
indicate sounders are
enabled
Enable sounders
step 2
Press button
Mode
Activate zone input
delays step 1
Press button till
Ad is displayed
Activate zone input
delays step 2
Enter
Dot flashes to indicate
that delays are active
if they have been set
in engineering mode
(refer to operation and
maintenance manual
configuration table)
Press button
Mode
Dot stops flashing to
indicate delays have
been de-activated
De-activate zone
input delays
Return system to
normal
Press button till
Ad is displayed
Enable
Control
Leaves only
Alarm/Fault Warning
Silence and Lamp test
buttons operable
Turn key and
remove
For service contact:
Man-1136_Hydrosense_HSCP_User_01
Telephone:
Page 6 of 6