Download Hotpoint HTDX100GDWW Instructions / Assembly
Transcript
Installation Instructions Gas Dryer DES I GN CE R TI FI E D 4uestions on Installation" &all: GE&ARES 8S RUYLVLWRXUZHEVLWHDWwww.GEAppliances.com (US) %EFORE <O8 %EGIN WARNING RISK OF FIRE Read these instructions completely and carefully IM3ORTANT6DYHWKHVHLQVWUXFWLRQVIRU ORFDOLQVSHFWRU·VXVH IM3ORTANT2EVHUYHDOOJRYHUQLQJFRGHV DQGRUGLQDQFHV Note to Installer %HVXUHWROHDYHWKHVH LQVWUXFWLRQVZLWKWKHFXVWRPHU Note to &ustomer .HHSWKHVHLQVWUXFWLRQV ZLWK\RXU2ZQHU·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¿HGLQVWDOOHU ,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQDFFRUGDQFHZLWKORFDO FRGHV,QWKHDEVHQFHRIORFDOFRGHVLQVWDOODWLRQPXVWFRPSO\ZLWK1DWLRQDO)XHO*DV &RGH$16,=1)3$RUWKH&DQDGLDQ1DWXUDO*DVDQG3URSDQH,QVWDOODWLRQ&RGH &6$% California Safe Drinking Water and Toxic Enforcement Act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µULJLGPHWDOGXFWLQJIRUH[KDXVWLQJWKHFORWKHVGU\HUWRWKHRXWGRRUV DO NOTLQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDO VHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHGLWPXVWEH8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFH ZLWKWKHLQVWUXFWLRQVIRXQGLQ´&RQQHFWLQJ7KH'U\HU7R+RXVH9HQWµRQSDJHRIWKLV PDQXDO)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQWRFROODSVHEHHDVLO\FUXVKHGDQGWUDS OLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH 'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOGEHH[SRVHGWRZDWHU DQGRUZHDWKHU 6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKH FXVWRPHU In the state of Massachusetts: InstaOOatLon Pust Ee SeUfoUPeG E\ a TuaOL¿eG oU OLcenseG contUactoU SOuPEeU oU Jas¿tteU TuaOL¿eG oU OLcenseG E\ the state When usLnJ EaOOt\Se Jas shutoff YaOYes the\ shaOO Ee ThanGOe t\Se A Àe[LEOe Jas connectoU Zhen useG Pust not e[ceeG feet M ATERIALS YOU WILL NEED 4" DIA. METAL DUCT (RECOMMENDED) (x2) 4" DIAM METAL ELBOW 10" ADJUSTABLE WRENCHES 8" PIPE WRENCH SLIP JOINT PLIERS 4" DIA. FLEXIBLE METAL (SEMI-RIGID) UL LISTED TRANSITION DUCT (IF NEEDED) KIT WX08X10077 (INCLUDES 2 ELBOWS) LEVEL FLAT BLADE SCREWDRIVER 4" DIA. FLEXIBLE METAL (FOIL TYPE) UL LISTED TRANSITION DUCT (IF NEEDED.) 6WHS9HULI\<RXU*DV,QVWDOODWLRQVHHVHFWLRQ 6WHS3UHSDUHWKH$UHDDQG([KDXVWIRU,QVWDOODWLRQRI 1HZ'U\HUVHHVHFWLRQ 6WHS&KHFNDQG,QVXUHWKH([LVWLQJ([WHUQDO([KDXVWLV &OHDQVHHVHFWLRQDQG0HHWV$WWDFKHG,QVWDOODWLRQ 6SHFL¿FDWLRQVVHHVHFWLRQ 6WHS5HPRYHWKH)RDP6KLSSLQJ3DGVVHHVHFWLRQ 6WHS0RYHWKH'U\HUWRWKH'HVLUHG/RFDWLRQ 6WHS/HYHO<RXU'U\HUVHHVHFWLRQ 6WHS&RQQHFWWKH*DV6XSSO\VHHVHFWLRQDQGFKHFNIRU OHDNVVHHVHFWLRQ EXHAUST HOOD PIPE COMPOUND SOAP SOLUTION FOR LEAK DETECTION (x2) 4" DUCT CLAMPS OR 4" SPRING CLAMPS DUCT TAPE SAFETY GLASSES (x2) FLEXIBLE GAS LINE CONNECTOR GLOVES 6WHS&RQQHFWWKH([WHUQDO([KDXVWVHHVHFWLRQ 6WHS&RQQHFWWKH3RZHU6XSSO\VHHVHFWLRQ 6WHS&KHFNWKH2SHUDWLRQRIWKH3RZHU6XSSO\*DV &RQQHFWLRQVDQG9HQWLQJ 6WHS3ODFHWKH2ZQHU·V0DQXDODQGWKH,QVWDOODWLRQ ,QVWUXFWLRQVLQDORFDWLRQZKHUHWKH\ZLOOEHQRWLFHG E\WKHRZQHU )RU$OFRYHRU&ORVHW,QVWDOODWLRQVHHVHFWLRQ )RU%DWKURRPRU%HGURRP,QVWDOODWLRQVHHVHFWLRQ )RU0RELOHRU0DQXIDFWXUHG+RPHVHHVHFWLRQ )RUJDUDJHLQVWDOODWLRQLIDOORZHGE\ORFDOFRGHVVHHVHFWLRQ 234D1582P003 31-16225-2 03-12 GE Installation Instructions Minimum &learance Other Than AlcoYe or &loset Installation 0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU &RQVLGHUDWLRQ mustEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRULQVWDOODWLRQDQGVHUYLFH 2 GAS RE48IREMENTS 3RE3ARING FOR INSTA//ATION WARNING OF NEW DRYER TI3: Install your dryer Eefore installinJ your Zasher This Zill alloZ Eetter access Zhen installinJ dryer e[haust Installation must conform to local codes and ordinances or in their aEsence the NATIONA/ F8E/ GAS &ODE ANSI =22 This Jas dryer is eTuipped Zith a 9alYe %urner AssemEly for use only Zith natural Jas 8sinJ conYersion Nit WE2;2 your local serYice orJani]ation can conYert this dryer for use Zith propane /3 Jas A// &ON9ERSIONS M8ST %E MADE %< 3RO3ER/< TRAINED AND 48A/IFIED 3ERSONNE/ AND IN A&&ORDAN&E WIT+ /O&A/ &ODES AND ORDINAN&E RE48IREMENTS The dryer must Ee disconnected from the Jas supply pipinJ system durinJ any pressure testinJ of that system at a test pressure in e[cess of 3SI K3a The dryer must Ee isolated from the Jas supply pipinJ system Ey closinJ the eTuipment shutoff YalYe durinJ any pressure testinJ of the Jas supply pipinJ of test pressure eTual to or less than 3SI K3a DRYER GAS SUPPLY CONNECTION DISCONNECTING GAS TURN GAS SHUT-OFF VALVE TO THE OFF POSITION. DISCONNECT AND DISCARD OLD FLEXIBLE GAS CONNECTOR AND OLD TRANSITION DUCTING MATERIAL. REPLACE WITH NEW CSA(AGA) APPROVED FLEXIBLE GAS LINE CONNECTOR AND UL APPROVED TRANSITION DUCT. WARNING NE9ER RE8SE O/D F/E;I%/E CONNECTORS 7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNV DQGSHUVRQDOLQMXU\$OZD\VXVHQHZÀH[LEOHFRQQHF WRUVZKHQLQVWDOOLQJJDVDSSOLDQFHV REMO9ING /INT FROM WA// E;+A8ST O3ENING 2" RemoYe and discard e[istinJ plastic or metal foil transition duct and replace Zith 8/ listed transition duct 2-5/8" WALL INTERNAL DUCT OPENING GAS S833/< CHECK THAT EXHAUST HOOD DAMPER OPENS AND CLOSES FREELY. 3/8" NPT MALE THREAD GAS SUPPLY NOTE: Add to vertical dimension the distance between cabinet bottom to floor. $LQ1DWLRQDO3LSH7DSHUWKUHDGSOXJJHGWDSSLQJ DFFHVVLEOHIRUWHVWJDXJHFRQQHFWLRQPXVWEHLQVWDOOHG LPPHGLDWHO\XSVWUHDPRIWKHJDVVXSSO\FRQQHFWLRQWR WKHGU\HU&RQWDFW\RXUORFDOJDVXWLOLW\VKRXOG\RXKDYH TXHVWLRQVRQWKHLQVWDOODWLRQRIWKHSOXJJHGWDSSLQJ 6XSSO\OLQHLVWREHLQULJLGSLSHDQGHTXLSSHGZLWK DQDFFHVVLEOHVKXWRȺZLWKLQIWRIDQGLQWKHVDPH URRPZLWKWKHGU\HU 8VHSLSHWKUHDGVHDOHUFRPSRXQGRU7HÀRQWDSHDSSUR SULDWHIRUQDWXUDORU/3JDV <RXPXVWXVHZLWKWKLVGU\HUDÀH[LEOHPHWDOFRQQHFWRU OLVWHGFRQQHFWRU$16,=&6$7KHOHQJWKRIWKH FRQQHFWVKDOOQRWH[FHHGIW &RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\ 2SHQVKXWRȺYDOYH TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES AND BREAKING THEM AWAY FROM THE DRYER LEGS. BE SURE TO REMOVE ALL OF THE FOAM PIECES AROUND THE LEGS. AD-8STING FOR E/E9ATION *DVFORWKHVGU\HUVLQSXWUDWLQJVDUHEDVHGRQVHDOHYHO RSHUDWLRQDQGQHHGQRWEHDGMXVWHGIRURSHUDWLRQDWRU EHORZIWHOHYDWLRQ )RURSHUDWLRQDWHOHYDWLRQVDERYHIWLQSXWUDWLQJV VKRXOGEHUHGXFHGDWDUDWHRISHUFHQWIRUHDFK IWDERYHVHDOHYHO ,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQGRUGLQDQFHVRU LQWKHLUDEVHQFHWKH1$7,21$/)8(/*$6&2'($16,= 2 Installation Instructions RECONNECTING GAS Listed connector ANSI Z21.24 / CSA 6.10 FLARE NPT 1/8" NPT PIPE PLUG FOR CHECKING GAS INLET PRESSURE 3/8" NPT PIPE SIZE AT LEAST 1/2" Note:7KHFRQQHFWRUDQG¿WWLQJVDUHGHVLJQHGIRUXVH RQO\RQWKHRULJLQDOLQVWDOODWLRQDQGDUHQRWWREHUHXVHG IRUDQRWKHUDSSOLDQFHRUDWDQRWKHUORFDWLRQ.HHSÀDUH HQGRIDGDSWRUIUHHRIJUHDVHRLODQGWKUHDGVHDODQW CA8TION: 8VHDGDSWHUVDVVKRZQ&RQQHFWRU QXWVPXVWQRWEHFRQQHFWHGGLUHFWO\WRSLSHWKUHDGV TIGHTEN ALL CONNECTIONS USING TWO ADJUSTABLE WRENCHES. DO NOT OVERTORQUE GAS CONNECTIONS! /EAK TEST WARNING: NE9ER 8SE AN O3EN F/AME TO TEST FOR GAS /EAKS TIGHTEN THE FLEXIBLE GAS LINE USING TWO ADJUSTABLE WRENCHES. 3 Installation Instructions E/ECTRICA/ CONNECTION 6 E;HA8ST INFORMATION INFORMATION WARNING IN CANADA AND IN THE 8NITED STATES THE RE48IRED E;HA8ST D8CT DIAMETER IS IN 2mm DO NOT 8SE D8CT /ONGER THAN S3ECIFIED IN THE E;HA8ST /ENGTH TA%/E WARNING TO RED8CE T+E RISK OF FIRE E/ECTRICA/ S+OCK AND 3ERSONA/ IN-8RY: 8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO ,QFUHDVHWKHGU\LQJWLPHVDQGWKHHQHUJ\FRVW 5HGXFHWKHGU\HUOLIH $FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG The correct e[haust installation is YO8R RES3ONSI%I/ITY 3roElems due to incorrect installation are not coYered Ey the Zarranty 5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLOWUDQVLWLRQ GXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW 7KHMA;IM8M A//OWA%/EGXFWOHQJWKDQGQXPEHURI EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRIGXFW QXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOOFDSDQGDOO FRQGLWLRQVQRWHGEHORZ7KHPD[LPXPGXFWOHQJWKIRUULJLG PHWDOGXFWLVVKRZQLQWKHWDEOHEHORZ DO NOT 8SE AN E;TENSION CORD OR AN ADA3TER 3/8G WIT+ T+IS A33/IANCE 'U\HUPXVWEHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFH ZLWKORFDOFRGHVDQGRUGLQDQFHVRULQWKHDEVHQFH RIORFDOFRGHVLQDFFRUGDQFHZLWKWKH1$7,21$/ (/(&75,&$/&2'($16,1)3$12 E/ECTRICA/ RE48IREMENTS 7KLVDSSOLDQFHPXVWEHVXSSOLHGZLWK9+]DQG FRQQHFWHGWRDSURSHUO\JURXQGHGEUDQFKFLUFXLW SURWHFWHGE\DRUDPSFLUFXLWEUHDNHURUWLPH GHOD\IXVH,IHOHFWULFDOVXSSO\SURYLGHGGRHVQRWPHHWWKH DERYHVSHFL¿FDWLRQVLWLVUHFRPPHQGHGWKDWDOLFHQVHG HOHFWULFLDQLQVWDOODQDSSURYHGRXWOHW EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Use only for short Recommended run installations WARNING THIS DRYER IS E48I33ED A THREE3RONG GRO8NDING 3/8G FOR YO8R 3ROTECTION AGAINST SHOCK HA=ARD AND SHO8/D %E 3/8GGED DIRECT/Y INTO A 3RO3ER/Y GRO8NDED THREE3RONG RECE3TAC/E DO NOT C8T OR REMO9E THE GRO8NDING 3RONG FROM THIS 3/8G 4" DIA. 4" DIA. 4" DIA. 4" No. of 90º Elbows 0 1 2 3 ENSURE PROPER GROUND EXISTS BEFORE USE. 2-1/2" Rigid Metal 90 60 45 35 Feet Feet Feet Feet Rigid Metal 60 45 35 25 E;HA8ST SYSTEM CHECK /IST Feet Feet Feet Feet HOOD OR WA// CA3 7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\RIELUGV RURWKHUZLOGOLIH 7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWRWKHH[KDXVW DLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFHWRSUHYHQW FORJJLQJ NeYer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nstallation Instructions STANDARD REAR EXHAUST (Vented above floor level) E;HA8ST CONNECTION WARNING TO RED8CE THE ELBOW HIGHLY RECOMMENDED RISK OF FIRE OR 3ERSONA/ IN-8RY: 7KLVFORWKHVGU\HUPXVWEHH[KDXVWHGWRWKH RXWGRRUV :HUHFRPPHQGWKDW\RXLQVWDOO\RXUGU\HUEHIRUH LQVWDOOLQJ\RXUZDVKHU7KLVZLOOSHUPLWGLUHFWDFFHVV IRUHDVLHUH[KDXVWFRQQHFWLRQ 8VHRQO\µULJLGPHWDOGXFWLQJIRUWKHKRPHH[KDXVW GXFW 8VHRQO\µULJLGPHWDORU8/OLVWHGÀH[LEOHPHWDO VHPLULJLGRUIRLOW\SHGXFWWRFRQQHFWWKHGU\HU WRWKHKRPHH[KDXVWGXFW,WPXVWEHLQVWDOOHG LQDFFRUGDQFHZLWKWKHLQVWUXFWLRQVIRXQGLQ ´&RQQHFWLQJ7KH'U\HU7R+RXVH9HQWµRQSDJHRI WKLVPDQXDO 'RQRWWHUPLQDWHH[KDXVWLQDFKLPQH\DZDOO DFHLOLQJJDVYHQWFUDZOVSDFHDWWLFXQGHUDQ HQFORVHGÀRRURULQDQ\RWKHUFRQFHDOHGVSDFH RIDEXLOGLQJ7KHDFFXPXODWHGOLQWFRXOGFUHDWHD SRWHQWLDO¿UHKD]DUG 1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFW ZLWKDNLWFKHQH[KDXVWV\VWHP$FRPELQDWLRQRI JUHDVHDQGOLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG 'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVW OHQJWKWDEOH/RQJHUGXFWVFDQDFFXPXODWHOLQW FUHDWLQJDSRWHQWLDO¿UHKD]DUG 1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW 7KLVZLOOFDXVHOLQWWRDFFXPXODWHFUHDWLQJD SRWHQWLDO¿UHKD]DUG 'RQRWDVVHPEOHGXFWZRUNZLWKDQ\IDVWHQHUV WKDWH[WHQGLQWRWKHGXFW7KHVHIDVWHQHUVFDQ DFFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG 'RQRWREVWUXFWLQFRPLQJRUH[KDXVWHGDLU 3URYLGHDQDFFHVVIRULQVSHFWLRQDQGFOHDQLQJRI WKHH[KDXVWV\VWHPHVSHFLDOO\DWWXUQVDQGMRLQWV ([KDXVWV\VWHPVKDOOEHLQVSHFWHGDQGFOHDQHGDW OHDVWRQFH\HDU RECOMMENDED CONFIGURATION TO MINIMIZE EXHAUST BLOCKAGE. ELBOW HIGHLY RECOMMENDED NOTE: ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING. 8 /E9E/ING DRYER LEVEL FRONT-TO-BACK. LEVEL SIDE-TO-SIDE. THIS DRYER COMES READY FOR REAR E;HA8STING IF S3ACE IS /IMITED 8SE THE INSTR8CTIONS IN SECTION TO E;HA8ST DIRECT/Y FROM THE SIDES OR %OTTOM OF THE CA%INET STANDARD REAR EXHAUST (Vented at floor level) FOR STRAIGHT LINE INSTALLATION, CONNECT THE DRYER EXHAUST TO THE EXTERNAL EXHAUST HOOD USING DUCT TAPE OR CLAMP. CSA (AGA) APPROVED NEW FLEXIBLE GAS LINE CONNECTOR EXTERNAL DUCT OPENING GAS INLET PIPE 4 LEVELING LEGS STAND THE DRYER UPRIGHT NEAR THE FINAL LOCATION AND ADJUST THE 4 LEVELING LEGS TO MATCH THE HEIGHT OF YOUR WASHER. ADJUST THE 2 ANTI-TIP LEGS TO CONTACT THE FLOOR. DUCT TAPE OR DUCT CLAMP 4" METAL DUCT (CUT TO PROPER LENGTH) DUCT TAPE OR DUCT CLAMP NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING. HOWEVER, IF FLEXIBLE DUCTING IS USED IT MUST BE UL-LISTED METAL NOT PLASTIC. 5 2 ANTI-TIP LEGS Installation Instructions CONNECTING THE DRYER TO HO8SE 9ENT DON’T RIGID META/ TRANSITION D8CT DO NOT SIT DRYER ON FLEXIBLE EXHAUST )RUEHVWGU\LQJSHUIRUPDQFHDULJLGPHWDOWUDQVLWLRQGXFWLV UHFRPPHQGHG 5LJLGPHWDOWUDQVLWLRQVGXFWVUHGXFHWKHULVNRIFUXVKLQJDQGNLQNLQJ 8//ISTED F/E;I%/E META/ SEMIRIGID TRANSITION D8CT ,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOH PHWDOVHPLULJLGGXFWLQJFDQEHXVHG.LW:;; 1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU RWKHUHQFORVHGVSDFHV 7RWDOOHQJWKRIÀ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À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ÀH[LEOHPHWDOIRLOW\SHGXFW $8/OLVWHGÀH[LEOHPHWDOIRLOW\SHGXFWPD\EHXVHG21/< LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOHPHWDOVHPLULJLG GXFWLQJFDQQRWEHXVHG$1'ZKHUHDµGLDPHWHUFDQEH PDLQWDLQHGWKURXJKRXWWKHHQWLUHOHQJWKRIWKHWUDQVLWLRQGXFW ,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDOIRLO W\SHGXFWVWKDWFRPSO\ZLWKWKH´2XWOLQHIRU&ORWKHV'U\HU 7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG 1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU RWKHUHQFORVHGVSDFHV 7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHWP $YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV )RUEHVWGU\LQJSHUIRUPDQFH 6OLGHRQHHQGRIWKHGXFWRYHUWKHFORWKHVGU\HURXWOHW SLSH 6HFXUHWKHGXFWZLWKDFODPS :LWKWKHGU\HULQLWVSHUPDQHQWSRVLWLRQH[WHQGWKHGXFW WRLWVIXOOOHQJWK$OORZµRIGXFWWRRYHUODSWKHH[KDXVW SLSH&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDV VWUDLJKWDVSRVVLEOHIRUPD[LPXPDLUÀRZ 6HFXUHWKHGXFWWRWKHH[KDXVWSLSHZLWKWKHRWKHUFODPS %ATHROOM OR %EDROOM INSTA//ATION 7KHGU\HUM8STEHYHQWHGWRWKHRXWGRRUV6HHE;HA8ST INFORMATIONVHFWLRQ 7KHLQVWDOODWLRQPXVWFRQIRUPZLWKORFDOFRGHVRULQWKH DEVHQFHRIORFDOFRGHVZLWKWKHNATIONA/ F8E/ GAS CODE ANSI =22 DO MO%I/E OR MAN8FACT8RED HOME INSTA//ATION ,QVWDOODWLRQPXVWFRQIRUPWRWKHMAN8FACT8RED HOME CONSTR8CTION SAFETY STANDARD TIT/E 2 3ART 28 RUZKHQVXFKVWDQGDUGLVQRWDSSOLFDEOHZLWKAMERICAN NATIONA/ STANDARD FOR MO%I/E HOME NO % 7KHGU\HUM8STEHYHQWHGWRWKHRXWGRRUVZLWKWKH WHUPLQDWLRQVHFXUHO\IDVWHQHGWRWKHPRELOHKRPHVWUXFWXUH 6HHE;HA8ST INFORMATIONVHFWLRQ 7KHYHQWM8ST NOTEHWHUPLQDWHGEHQHDWKDPRELOHRU PDQXIDFWXUHGKRPH 7KHYHQWGXFWPDWHULDOM8ST %E META/ KIT D6 M8STEHXVHGWRDWWDFKWKHGU\HUVHFXUHO\WR WKHVWUXFWXUH 7KHYHQW0867127EHFRQQHFWHGWRDQ\RWKHUGXFWYHQWRU FKLPQH\ 'RQRWXVHVKHHWPHWDOVFUHZVRURWKHUUHIDVWHQLQJGHYLFHV ZKLFKH[WHQGLQWRWKHLQWHULRURIWKHH[KDXVWYHQW 3URYLGHDQRSHQLQJZLWKDIUHHDUHDRIDWOHDVWVTLQRU LQWURGXFWLRQRIRXWVLGHDLULQWRWKHGU\HUURRP 6WDFNLQJRIDJDVGU\HULVQRWSHUPLWWHGLQDPRELOHKRPHRU PDQXIDFWXUHGKRPH ELBOW HIGHLY RECOMMENDED ELBOWS HIGHLY RECOMMENDED 6 Installation Instructions ADDING NEW D8CT 2 GARAGE INSTA//ATION IF A//OWED BY /OCA/ CODES FIXING HOLE 'U\HUVLQVWDOOHGLQJDUDJHVPXVWEHHOHYDWHGLQFKHV FPDERYHWKHÀRRU PORTION "A" DRYER E;HA8ST TO RIGHT /EFT OR BOTTOM CABINET WARNING BEFORE PERFORMING THIS E;HA8ST INSTA//ATION BE S8RE TO DISCONNECT THE DRYER FROM ITS E/ECTRICA/ S8PP/Y PROTECT YO8R HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE S8RE TO WEAR G/O9ES LEFT SIDE EXHAUST Reconnect the cut portion (A) of the duct to the blower housing. Make sure that the shortened duct is aligned with the tab in the base. Use the screw saved previously to secure the duct in place through the tab on the appliance base. ADDING E/BOW AND D8CT FOR E;HA8ST TO /EFT SIDE OF CABINET 3UHDVVHPEOHµHOERZZLWKµGXFW:UDSGXFWWDSH DURXQGMRLQW ,QVHUWGXFWDVVHPEO\HOERZ¿UVWWKURXJKWKHVLGH RSHQLQJDQGFRQQHFWWKHHOERZWRWKHGU\HULQWHUQDO GXFW REMOVE SCREW AND SAVE. CA8TION: Be sure not to pull or damaJe the electrical Zires inside the dryer Zhen insertinJ the duct REMOVE DESIRED KNOCKOUT (ONE ONLY). Detach and remove the bottom, right or left side knockout as desired. Remove the screw inside the dryer exhaust duct and save. Pull the duct out of the dryer. EXHAUST CAN BE ADDED TO LEFT OR RIGHT SIDE Note: Only 4” round rigid metal ducting allowed inside dryer. DUCT TAPE FIXING HOLE B A 9" Cut the duct as shown and keep portion A. TAB /OCATION $SSO\GXFWWDSHDVVKRZQRQWKHMRLQWEHWZHHQWKH GU\HULQWHUQDOGXFWDQGWKHHOERZ DUCT TAPE BEND TAB UP 45 o Through the rear opening, locate the tab in the middle of the appliance base. Lift the tab to about 45º using a flat blade screwdriver. 7 CA8TION: Internal duct joints must be secured Zith tape otherZise they may separate and cause a safety ha]ard Installation Instructions ADDING E/BOW FOR E;HA8ST THRO8GH BOTTOM OF CABINET CHANGING DIRECTION OF DOOR OPENING ,QVHUWWKHHOERZWKURXJKWKHUHDURSHQLQJDQGFRQQHFW LWWRWKHGU\HULQWHUQDOGXFW $SSO\GXFWWDSHRQWKHMRLQWEHWZHHQWKHGU\HULQWHUQDO GXFWDQGHOERZDVVKRZQRQSDJH REMOVE 4 HINGE SCREWS. CAUTION: Internal duct joints must be secured with tape, otherwise they may separate and cause a safety hazard. ADDING CO9ER P/ATE TO REAR OF CABINET ROTATE DOOR 180° AND REINSTALL. PL ATE (KIT WE1M454) &RQQHFWVWDQGDUGPHWDOHOERZVDQGGXFWVWRFRPSOHWH WKHH[KDXVWV\VWHP&RYHUEDFNRSHQLQJZLWKDSODWH.LW :(0DYDLODEOHIURP\RXUORFDOVHUYLFHSURYLGHU 3ODFHGU\HULQ¿QDOORFDWLRQ WARNINGNE9ER /EA9E THE BACK OPENING WITHO8T THE P/ATE 8 REMOVE 4 HOLE PLUGS AND PLACE THEM IN THE HOLES ON THE OPPOSITE SIDE. Installation Instructions CONNECTING IN/ET HOSES (on some models) CONNECTING IN/ET HOSES cont 87XUQWKHZDWHUIDXFHWRQ &KHFNIRUOHDNVDURXQGWKH¶·<··FRQQHFWRUIDXFHWDQG KRVHFRXSOLQJV 7RSURGXFHVWHDPWKHGU\HUPXVWFRQQHFWWRWKHFROG ZDWHUVXSSO\6LQFHWKHZDVKHUPXVWDOVRFRQQHFWWRWKH FROGZDWHUD´<µFRQQHFWRULVLQVHUWHGWRDOORZERWKLQOHW KRVHVWRPDNHWKDWFRQQHFWLRQDWWKHVDPHWLPH NOTE:8VHWKHQHZLQOHWKRVHVSURYLGHGQHYHU XVHROGKRVHV 7XUQWKHFROGZDWHUIDXFHWRȺ5HPRYHWKHZDVKHULQOHW KRVHIURPWKHZDVKHU¿OOYDOYHFRQQHFWRUFROG 2(QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGVFUHZWKH IHPDOHFRXSOLQJRIWKHVKRUWKRVHRQWRWKHZDVKHU¿OO YDOYHFRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG $WWDFKWKHIHPDOHHQGRIWKH¶·<··FRQQHFWRUWRWKH PDOHFRXSOLQJRIWKHVKRUWKRVH(QVXUHWKHUXEEHUÀDW ZDVKHULVLQSODFH7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG WATER S8PP/Y RE48IREMENTS +RWDQGFROGZDWHUIDXFHWV0867EHLQVWDOOHGZLWKLQ LQFPRI\RXUZDVKHU·VZDWHULQOHW7KHIDXFHWV 0867EHLQFPJDUGHQKRVHW\SHVRLQOHWKRVHV FDQEHFRQQHFWHG:DWHUSUHVVXUH0867EHEHWZHHQ DQGSRXQGVSHUVTXDUHLQFK<RXUZDWHUGHSDUWPHQW FDQDGYLVH\RXRI\RXUZDWHUSUHVVXUH NOTE: $ZDWHUVRIWHQHULVUHFRPPHQGHGWRUHGXFH EXLOGXSRIVFDOHLQVLGHWKHVWHDPJHQHUDWRULIWKHKRPH ZDWHUVXSSO\LVYHU\KDUG 6 SER9ICING WARNING /ABE/ A// WIRES PRIOR TO DISCONNECTION WHEN SER9ICING CONTRO/S WIRING ERRORS CAN CA8SE IMPROPER AND DANGERO8S OPERATION AFTER SER9ICING INSTA//ATION ,QVHUWWKH¿OWHUVFUHHQLQWKHFRXSOLQJRIWKHZDVKHU·V LQOHWKRVH,IDUXEEHUÀDWZDVKHULVDOUHDG\LQSODFH UHPRYHLWEHIRUHLQVWDOOLQJWKH¿OWHUVFUHHQ$WWDFKWKLV FRXSOLQJWRRQHPDOHHQGRIWKH¶·<··FRQQHFWRU7LJKWHQ E\KDQGXQWLO¿UPO\VHDWHG (QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGDWWDFKWKH GU\HU·VORQJLQOHWKRVHWRWKHRWKHUPDOHHQGRIWKH¶·<·· FRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG 6(QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGDWWDFK WKHRWKHUHQGRIWKHGU\HU·VORQJLQOHWKRVHWRWKH¿OO YDOYHFRQQHFWRUDWWKHERWWRPRIWKHGU\HUEDFNSDQHO 7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG )RUVHUYLFLQJSKRQHQXPEHUVIRUUHSODFHPHQWSDUWVDQG RWKHULQIRUPDWLRQUHIHUWR2ZQHU·V0DQXDORUYLVLWRXU :HEVLWH 5(*,67(5<2851(:$33/,$1&(725(&(,9($1< ,03257$17352'8&7127,),&$7,216 3OHDVHJRWRZZZGEAppliances.comRUPDLOLQ\RXU 3URGXFW5HJLVWUDWLRQ&DUG )RUTXHVWLRQVRQLQVWDOODWLRQFDOO86RU &DQDGD 8VLQJSOLHUVWLJKWHQDOOWKHFRXSOLQJVZLWKDQDGGLWLRQDO WZR²WKLUGVWXUQ NOTE:'RQRWRYHUWLJKWHQ'DPDJHWRWKHFRXSOLQJVPD\ UHVXOW 9 Notes 10 Notes 11