Download Dacor DR30GIFS User's Manual
Transcript
DR30GS, DR30GFS, DR30GIS, DR30GIFS Revised 04/04/13 Page 1/5 Document # PG05-007 Distinctive™ 30” Wide All Gas Ranges PLANNING GUIDE All tolerances ±1/16” (±1.6 mm) unless otherwise noted. warning • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • This appliance must be installed in accordance with the accompanying installation instructions. Front of open door Front of handle Front of knobs Front panel Rear of front panel 46 3/4” (118.7 cm) 28 9/16” (72.5 cm) 28” (71.1 cm) 26 1/8” (66.4 cm) 24” (61.0 cm) 1 1/8” (2.9 cm) Backguard thickness 9” (22.9 cm) Grates extend Backguard*1 1” above trim 3” (7.6 cm) backguard* DR30GI[F]S: 1/4” (6.4 mm) thick top trim External handle shown, some models have integral handle (see inside cover) DR30G[F]S: Full stainless steel side panels DR30GI[F]S: 3 1/2” (8.9 cm) 2 partial stainless steel side panels (removable) Product width: 29 7/8” (75.9 cm) NOTE: Models DR30GS and DR30GFS are not compatible with a raised vent. 6” (15.2 cm) backguard* 1 3/4” (4.4 cm) backguard* 1 * See table for compatibility 35” (88.9 cm) to 37” (94.0 cm) Overall Depth Dimensions - side view Part Number Description Compatibility Standard on models DR30GIS, DR30GIFS Optional on models DR30GS, DR30GFS AER30GLBG Low profile (1 3/4 inch) AERB30G03 3 Inch Optional on models DR30GS, DR30GFS NOT compatible with models DR30GIS, DR30GIFS AERB30G06 6 Inch Standard on models DR30GS, DR30GFS NOT compatible with models DR30GIS, DR30GIFS AERB30G09 9 Inch Optional on models DR30GS, DR30GFS NOT compatible with models DR30GIS, DR30GIFS 1 Only backguard model AER30GLBG is compatible with a raised vent. Available Backguards All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093 DR30GS, DR30GFS, DR30GIS, DR30GIFS Revised 04/04/13 Page 2/5 Document # PG05-007 Distinctive 30” Wide All Gas Ranges PLANNING GUIDE All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted. B 13” (33.0 cm) max.4 ■■ Failure to meet or exceed the maximum and minimum dimensions/clearances stated may result in a fire hazard. ■■ The range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. ■■ To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above surface units should be avoided. If cabinet storage space is to be provided directly above the range, the risk of personal injury may be reduced by installing a range hood. ■■ In all instances, installation of a range hood is highly recommended. The hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets. See the range hood specifications for minimum clearances. ■■ If installing a raised vent, install only Dacor model ERV3015. ■■ The range may be installed flush to the rear wall. See diagram and notes for rear wall surface requirements. It is not necessary to install noncombustible materials behind the range below the countertop height. ■■ Any openings in the wall behind the appliance or in the floor underneath it must be sealed. Back wall immediately behind range6 Top of finished counter Note 1 Note 5 Suggested location of utilities3 A 14” (35.6 cm) min.4 Note 2 C A* B C 30” min. (76.2 cm) 36” (91.4 cm) recommended 30” (76.2 cm) min. 37” (94.0 cm) max. * See the cutout dimensions on following page for self-rimming installations. Freestanding Installation Cabinet Cutout Dimensions - Models DR30GS, DR30GFS, DR30GIS and DR30GIFS 1 30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. clearance if bottom of wood or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015” (0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30” (76.2 cm) min. clearance between top of range grates and bottom of unprotected wood or metal cabinet. If installing range hood, check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See Product Dimensions. 3 Consult local code and following pages for requirements. 4 This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range. 5 10” (25.4 cm) min. to combustible sidewalls above range (both sides). 6 Non-combustible surface required for models DR30GIS and DR30GIFS up to vertical distance specified in note 1 or range hood, whichever is lower. Noncombustible surface recommended, but not required, for models DR30GS and DR30GFS. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093 DR30GS, DR30GFS, DR30GIS, DR30GIFS Revised 04/04/13 Page 3/5 Document # PG05-007 Distinctive 30” Wide All Gas Ranges PLANNING GUIDE Self-Rimming Installation, custom Cutout Options (Models DR30GIS and DR30GIFS Only) NOTE: The diagrams below are for installations that require custom cutouts. See page 5/5 for installation in standard 30 inch wide cutout. All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted. 10” min. (25.4 cm) to any combustibles above counter both sides 25 5/8” max. (65.1 cm) For all self-rimming installations: Countertop height: 34 3/4” (88.3 cm) min. 36 7/8” (93.7 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max. 1 10” min. (25.4 cm) Rear wall or 3/4” min. (1.9 cm) to any combustibles countertop edge countertop overhang above counter both sides Non-combustible rear wall required 1 29 1/4” (74.3 cm) countertop opening 30” (76.2 cm) cabinet opening below countertop 3 Notch countertop to width of cabinets Cabinet face below countertop 21” 20 3/4” (53.3 cm)� to (52.7 cm) 24” (61.0 cm) 25 3/4” (65.4 cm) max. Notch countertop to width of cabinets Cabinet face Countertop front below countertop 2 Cabinet Depth Greater Than 24” 3 1/4” Side Panels Installed, Range Back Overhanging Countertop (Top View) Cabinets Less Than 24” Deep, 3 1/4” Side Panels Installed, Range Back Flush to Wall (Top View) 10” min. (25.4 cm) to any combustibles above counter both sides 29 1/4” (74.3 cm) countertop opening 30” (76.2 cm) cabinet opening below countertop 3 Cabinet face below countertop Notch countertop overhang to width of cabinets 29 1/4” (74.3 cm) countertop opening 30” (76.2 cm) cabinet opening below countertop 3 21 1/8” 20 7/8” (53.7 cm) to (53.0 cm) 24 1/8” (61.3 cm) 1 10” min. (25.4 cm) Rear wall or to any combustibles countertop edge above counter both sides Non-combustible rear wall required 1 24” (61.0 cm) Countertop overhang 1 5/8” (4.1 cm) max. Cabinet Exactly 24” Deep, 3 1/4” Side Panels Removed, Range Back Flush to Wall (Top View) 29 1/4” (74.3 cm) countertop opening 30” (76.2 cm) cabinet opening below countertop 3 Cabinet face below countertop Notch countertop overhang to width of cabinets 1” min. (2.5 cm) Countertop overhang 24 1/8” (61.3 cm) Countertop overhang 1 5/8” (4.1 cm) max. 2 Cabinet Depth Greater Than 25 1/8” 3 1/4” Side Panels Removed, Range Back Overhanging Countertop (Top View) 1 On models DR30GIS and DR30GIS, non-combustible surface required immediately behind range, as specified on previous page, when back of backguard is less than 2 1/2” (6.4 cm) from rear wall. 2 Models DR30GIS and DR30GIS include self-rimming trim piece that attaches to back of range and covers the edge of the countertop overhang in back. 3 To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm). This configuration is only for models DR30GIS and DR30GIS with side panels behind door removed. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093 DR30GS, DR30GFS, DR30GIS, DR30GIFS Revised 04/04/13 Page 4/5 Document # PG05-007 Distinctive 30” Wide All Gas Ranges PLANNING GUIDE Raised Vent (Self-Rimming) Installation Cutout Options (Models DR30GIS and DR30GIFS Only) All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted. 3/8” min. (1.0 cm) flat countertop overhang required behind cutout For all installations with a raised vent: Countertop height: 34 3/4” (88.3 cm) min. 36 7/8” (93.7 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max. Wall NOTE: For all raised vent installations, use only Dacor raised vent model ERV3015. 10” min. (25.4 cm) Rear wall or to any combustibles countertop edge above counter both sides 3/8” (9.5 mm) min. countertop overhang Stiffener Countertop ERV3015 raised vent 27 1/2” (69.9 cm) raised vent opening 1 29 1/4” (74.3 cm) countertop opening 30” (76.2 cm) cabinet opening below countertop Cabinet face below countertop Notch countertop overhang to width of cabinets 3” (7.6 cm) 3/8” (9.5 mm) min. countertop overhang 25 3/4” (65.4 cm) max. 30” (76.2 cm) cabinet opening below countertop Cabinet face Countertop overhang 1 5/8” (4.1 cm) max. IMPORTANT: If optional side panels are not installed cabinet face must be flush with back of control panel. Side View - DR30GI[F]S Range and ERV3015 Raised Vent Rear wall or countertop edge 3” (7.6 cm) 10” min. (25.4 cm) Rear wall or to any combustibles countertop edge above counter both sides 3/8” (9.5 mm) min. countertop overhang 27 1/2” (69.9 cm) raised vent opening 20 7/8” 20 5/8” (53.0 cm) to (52.4 cm) 24 1/8” (61.3 cm) Notch countertop overhang to width of cabinets Countertop front Back of control panel 3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener 27 1/2” (69.9 cm) raised vent opening 1 29 1/4” (74.3 cm) countertop opening DR30GI[F]S range Shown with partial side panel installed 20 5/8” (52.4 cm) 24” - 24 1/4” Cabinet Depth Partial Side Panels Installed (Top View)2 10” min. (25.4 cm) to any combustibles above counter both sides 29 1/2” (74.9 cm) Cabinet face below countertop 24 1/4” - 27 1/2” Cabinet Depth Partial Side Panels Installed (Top View) 1 29 1/4” (74.3 cm) countertop opening 30” (76.2 cm) cabinet opening below countertop Cabinet face below countertop Notch countertop overhang to width of cabinets 3” (7.6 cm) 24 1/8” (61.3 cm) Countertop overhang 1 5/8” (4.1 cm) max. Custom Cabinet 27 1/2” or Deeper, Partial Side Panels Removed (Top View) 1 To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm). Width notches remains 30”. 2 For 24 to 24 1/4 inch deep cabinets, the side panels and control panel will protrude from the cabinet face a total of 5 5/8 inches. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093 DR30GS, DR30GFS, DR30GIS, DR30GIFS Revised 04/04/13 Page 5/5 Document # PG05-007 PLANNING GUIDE Distinctive 30” Wide All Gas Ranges Self-Rimming Installation, Standard Cutout Requirements (Models DR30GIS and DR30GIFS Only) 10” min. (25.4 cm) to any combustibles above counter both sides 24 3/8” min. (61.9 cm) Non-combustible rear wall required 30” (76.2 cm) countertop/cabinet opening Cabinet face below countertop Countertop front standard width CUTOUT FOR model dr30dI[F]S self-rimming TRIM KIT atkdr30Gw required 10” (25.4 cm) 10” (25.4 cm) Electrical Specifications/Dimensions, All Models 12 1/4” (31.1 cm) to 14 1/4” (36.2 cm) 6’ (183 cm) long 12” (30.5 cm) 2 1/2” (6.4 cm) 3 1/2” (8.9 cm) 1” (2.5 cm) 4 1/4” (10.8 cm) utility clearance behind range back of range ELECTRICAL REQUIREMENTS GAS SUPPLY PRESSURE REQUIREMENTS Electrical Circuit Required Total Connected Load Gas Type 120 Vac, 60 Hz, 15 Amps., dedicated, grounded 4.0 Amps. @ 120 Vac, 60 Hz Natural LP Manifold Pressure* (WC) Min. Gas Supply Pressure (WC) Max. Input Pressure 5” 6” 1/2 psi 10” 11” 1/2 psi IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label. The gas inlet on the regulator accommodates a 1/2” NPT gas line connection. The range can also accommodate a 3/4” NPT gas line connection by removing the 1/2” to 3/4” adapter on the regulator inlet. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093