Download Dacor dacor er30g User's Manual

Transcript
ER30G
Revised
10/08/08
30” Wide, Epicure™
All Gas Range
1/2
PLANNING
GUIDE
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
45 1/2” (1156mm)
28 1/2” (724mm)
27” (686mm)
26 1/16” (662mm)
23 15/16” (608mm)
Front of open door
Front of handle
Front edge of bullnose
Front panel
Rear of front panel
1 1/16” (27mm)
Backguard
thickness
9” (229mm)
Backguard**
6” (152mm)
3” (76mm) Backguard*
Backguard**
1 9/16”
(40mm)
* Standard
** Optional
35”
(889mm)
to
37 1/8”
(943mm)
Product Width: 29 7/8” (759mm)
ER30G
Overall Depth Dimensions
side view
Range Model
ER30G
Electrical
Circuit
Required
Total
Connected
Load
240 Vac,
60 Hz, 15 Amp
0.5 kW
(4.0 Amp)
Electrical Requirements
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
warning
◊
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
◊
This appliance must be installed in accordance with the
accompanying installation instructions.
Specifications are subject to change without notice.
See installation instructions for additional details.
5.5
ER30G
30” Wide, Epicure™
All Gas Range
Revised
10/08/08
2/2
PLANNING
GUIDE
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
B
Model Number
ER30G
“A”
“B”
30 1/16” (764mm)
30” (762mm) Minimum
36” (914mm) Recommended
Non-Combustible
surface along
back wall
recommended
30” (762mm)
min.*
A
NOTES:
Suggested
location of
utilities***
**
* Vertical to combustible surface
** Cabinet depth is at discretion of customer
but cabinet face MUST NOT protrude further
than rear of front panel, see product dimesions
*** Consult local code for exact location
requirements.
1. Utilities may be located in the lower left
corner of the adjacent right cabinet.
(Recommended)
2. Contact your local building department
to verify compliance with local code
interpretation.
Cutout dimensions
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Natural
5”
6”
1/2 p.s.i.
LP
10”
11”
1/2 p.s.i.
IMPORTANT: The information above is for reference only. If the
above data does not agree with the product data label, use the
data on the product data label on top of the kick plate below the
door (remove the door according to the installation instructions to
view it).
The gas connection is located on the back of the unit as shown.
12 1/2”
(31.8 cm)
to
14 5/8”
(37.1 cm)
2 5/8”
(66.7 cm)
back of range
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.6