Download Bell DBA-8Z User's Manual
Transcript
Digibell Vandal Resistant Systems CABLE SUPPLEMENT 1 Entrance Zone isolation (DBA-8Z) Daisy-chained Zone isolators Power supplies at each floor level PD-250 Issue 1 Cable legends 1x CAT5 8 Cores of CAT5/5e 2 4 2 Cores of CAT5/5e Optional cores depending on feature required bell system www.bellsystem.co.uk Digibell PD-250 Issue 1 System Part 1 Note 1. Contact Technical support for more than 1 phone per flat. 2. Maximum of 300m between the furthest 2 points. 3. All control equipment must be located in a protected indoor environment. 4. One DBA-8Z Phone Isolator per 8 flats. To Floor 2 1x CAT5 8 Flats/Phones 01 EF 2 7 89 A 7 8 9A 7 8 9A 340C PSU 1x CAT5 3m Max. 3m Max. 1x CAT5 50m Max. 4 Mo 1 ON ON 13:44 56 ON AUTO OFF P MANUAL CK MIN CLO TIME R HOUR DAY BSD-DIG 2 cores of 1.5mm2 TS2000-BST Time Clock (Trades) PS4 PS4 PSU 50m Max. 3m Max. 3x CAT5 Cores of CAT5 0.5A 4 1.0A 8 2 Descriptions DBA-8Z Zonal Isolator/Distributor BSD-DIG Digital Door Controller TS2000-BST Time Clock PS4 Power Supply, 13.8VDC, 4A 340C Power Supply, 13.8VDC, 1.5A 2 cores of 1.5mm2 01 EF 2 3456 340C PSU 1x CAT5 DBA-8Z 01 EF 2 3456 To distribution of next 16 100m Max. BCD BC D DBA-8Z 2 cores of 1.5mm2 3456 3456 01 EF 2 DBA-8Z Flat 8 1x CAT5 1x CAT5 100m Max. BC D DBA-8Z 8 Flats/ Phones 1x CAT5 1x CAT5 8 Flats/Phones Flat 1 7 89 A Floor 1 8 Flats/ Phones Flat 24 BCD Flat 17 Exit Button Entrance www.bellsystem.co.uk Lock release Digibell PD-250 Issue 1 System Part 2 Note 1. Contact Technical support for more than 1 phone per flat. 2. Maximum of 300m between the furthest 2 points. 3. All control equipment must be located in a protected indoor environment. 4. One DBA-8Z Phone Isolator per 8 flats. To next Floor 1x CAT5 8 Flats/Phones Flat 81 1x CAT5 1x CAT5 DBA-8Z DBA-8Z DBA-8Z 2 cores of 1.5mm2 100m Max. DBA-8Z 01 EF 2 7 89 A 7 89 A 7 8 9A 1x CAT5 1x CAT5 7 8 9A 8 Flats/ Phones 340C PSU 1x CAT5 Flat 56 3456 8 Flats/Phones Flat 49 Floor 2 3m Max. 1x CAT5 2 cores of 1.5mm2 01 EF 2 3456 BC D 3456 3456 01 EF 2 340C PSU To distribution of next 16 Flat 72 1x CAT5 1x CAT5 100m Max. 01 EF 2 BC D 8 Flats/ Phones 8 Flats/Phones BCD Floor 3 Flat 65 BC D 8 Flats/ Phones Flat 88 3m Max. Flat 33 8 Flats/ Phones 8 Flats/Phones 1x CAT5 1x CAT5 100m Max. Flat 40 100m Max. 1x CAT5 1x CAT5 3m Max. BC D 1x CAT5 BC D BC D 7 89 A 7 8 9A 340C PSU 2 cores of 1.5mm2 01 EF 2 3456 01 EF 2 3456 To distribution of next 16 DBA-8Z 01 EF 2 7 89 A BC D DBA-8Z 2 cores of 1.5mm2 34 56 34 56 01 EF 2 DBA-8Z 7 89A DBA-8Z 340C PSU 3m Max. 1x CAT5 From Floor 1