Transcript
GLENDALE™ UNDERCOUNTER SINK BARRIER FREE VITREOUS CHINA GLENDALE™ UNDER COUNTER SINK • • • • Shell style pattern in bowl Made from vitreous china Unglazed rim for undermount Front overflow with option of rear overflow installation for Barrier Free • Center drain outlet • Supplied with mounting kit (047194-0070A) and template ❏ 0625.000 464 x 381mm (18-1/4" x 15") Bowl Sizes: 406mm (16") wide 311mm (12-1/4") front to back 152mm (6") deep A FINISHED WALL OR SPLASHBACK B 51mm (2) MIN. 76mm (3) 610mm (24) OVERFLOW 76mm (3) Compliance Certifications Meets or Exceeds the Following Specifications: • ASME A112.19.2M for Vitreous China Fixtures 41mm (1-5/8) EDGE OF COUNTER TOP CUTOUT 381mm (15) 180mm (7-5/8) C/L OF 864mm OUTLET (34) 45° C/L MOUNTING CLIP (SEE DETAIL) 25mm (1) 464mm (18-1/4) SEALING COMPOUND *343mm * 273mm BRASS INSERT MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES CHECK LOCAL CODES. With overflow to the rear and countertop 864mm (34”) from finished floor. Lavatory installed 51mm (2”) MIN. from front edge of countertop. Countertop thickness to be 25mm (1”) maximum. 19mm (3/4) MIN. LAVA 203mm (8) CLIP MACH. SCREW 1-1/4 O.D. WASTE 1-1/4 O.D. TAILPIECE * See faucet section for additional models available 229mm (9) MIN. DETAIL OF MOUNTING CLIP (KIT No.47194.0070A) 16mm (5/8) SUPPLIES AS REQ'D. To Be Specified: ❏ Color: ❏ Faucet*: ❏ Faucet Finish: ❏ Supplies: ❏ 1-1/4" Trap: 152mm (6) MAX. BARRIER FREE CLEARANCE 19mm (3/4) (10-3/4) 787mm (31) 864mm (34) DRAWING FOR DIMENSIONAL PURPOSES ONLY. IT IS NOT AN EXACT REPRESENTATION. 686mm (27) MIN. COUNTERTOP (BY OTHERS) 197mm (7-3/4) (13-1/2) 203mm (8) MIN. FINISHED FLOOR FITTING A B CENTER-SET 27mm(1-1/16) 102mm(4) SPREAD 32mm(1-1/4) 203mm(8) REFER TO INSTRUCTIONS PROVIDED WITH KIT FOR ADDITIONAL INFORMATION NOTES: * DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TRAP ARE SUGGESTED. ▼ UNDERCOUNTER MOUNTING KIT SUPPLIED WITH SINK. FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. IN-FIELD ADJUSTMENT OF POP-UP ROD EXTENSION REQUIRED. PROVIDE A 2-1/2" OFF-SET BEND FOR PROPER OPERATION. USE ENCLOSED TEMPLATE FOR COUNTERTOP CUTOUT. SEALING COMPOUND SUPPLIED BY OTHERS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages. J47 © 2006 American Standard Inc. Revised 5/06