Download Mitsubishi 20-MYA Specifications
Transcript
AIR-COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS DATA BOOK Series : PE(H) Cooling only Heat pump Model PE-7MYC PE-8MYC PE-10MYC PE-15MYC PE-20MYC Service ref. PE-7MYC-EU PE-8MYC-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU PEH-5MYA PEH-7MYA PEH-8MYA PEH-10MYA PEH-15MYA PEH-20MYA PEH-5MYA-EU PEH-7MYA-EU PEH-8MYA-EU PEH-10MYA-EU PEH-15MYA-EU PEH-20MYA-EU CONTENTS SAFETY FOR USE ------------------------------------------------------2 A COMPLETE LINE UP ------------------------------------------------4 FEATURES-----------------------------------------------------------------5 DESCRIPTIONS----------------------------------------------------------5 MECHANICAL SPECIFICATIONS ----------------------------------6 TYPICAL INSTALLATION EXAMPLE ------------------------------6 MODEL-DESIGNATION BREAKDOWN ---------------------------7 SPECIFICATIONS -------------------------------------------------------8 ELECTRICAL DATA ----------------------------------------------------11 SELECTION PROCEDURE -----------------------------------------16 CAPACITY TABLES ----------------------------------------------------18 CAPACITY REDUCTION RATIO DUE TO CHANGES IN PIPING LENGTH ------------------------------36 OPERATION RANGE--------------------------------------------------37 FAN PERFORMANCE-------------------------------------------------38 SOUND DATA------------------------------------------------------------41 APPROXIMATION FOR SOUND POWER LEVEL AT SUPPLY DUCT FLANGE OF UNIT------------------42 OUTLINE DIMENSIONS----------------------------------------------43 WIRING DIAGRAMS---------------------------------------------------50 ELECTRICAL OPERATION FLOW CHARTS -------------------63 REFRIGERANT SCHEMATICS-------------------------------------66 SAFETY & CONTROL DEVICES ----------------------------------67 SPECIAL ORDER ------------------------------------------------------69 PHYSICAL DATA--------------------------------------------------------70 INSTALLATION ----------------------------------------------------------79 INSTRUCTIONS FOR USE ------------------------------------------96 HOW TO OPERATE -------------------------------------------------101 LOW AMBIENT COOLING PARTS; OPTION;PAC-205FC (Fan controller)----------------------------104 SPECIFICATION GUIDELINES -113 Specifications subject to change without notice. -1- SAFETY FOR USE Before conducting installation work, please read this ''SAFETY FOR USE'' carefully for correct installation. Since the caution items shown here contain important description relative to safety, please observe them without fail. Warning Erroneous handling gives a high possibility to induce serious results such as death or heavy injury. Caution Erroneous handling may induce serious injury depending on the situation. After reading, please keep it with you together the Instruction Manual, and read it again at the movement of the unit. Warning Never repair the unit, remodel or transfer it to another site by yourself. If they are performed improperly, water leakage, electric shock or fire may result. If you need to have the unit repaired or moved, consult your dealer. Ask your dealer or specialized subcontractor for installation. Conducting installation work by yourself improperly may cause a fire, electric shock or water leakage. For installation, conduct the work correctly by following the Installation Manual. Improper installation may cause a fire, electrical shock or water leakage. Use only the specified refrigerant (R-22) to charge the refrigerant circuit. Do not mix it with any other refrigerant and do not allow air to remain in the circuit. Air enclosed in the circuit can cause high pressure resulting in a rupture and other hazards. Install the unit on a spot sufficiently durable against the unit weight. Insufficient durability can cause an injury by the falling down of unit. Ventilate the room if refrigerant leaks during Installation. The refrigerant heated generates poisonous gas by decomposition which can cause poisoning. All electric work must be performed by licensed technician, according to local regulations and the instructions given in this manual. The units should be powered by dedicated power lines. Power lines with insufficient capacity or improper electrical work may result in electric shock or fire. After completing installation work, make sure that refrigerant gas has not leaked. If refrigerant gas has leaked and exposed to fan heater, stove, oven and so on, it may generate noxious gases. Please do the gas leakage inspection before starting. Use only the specified cables for wiring. The connections must be made secured without tension the terminals. Improper connection or fastening can cause a fire or electrical shock. The unit should be installed according to the instructions in order to minimize the risk of damage from earthquakes, typhoons or strong winds. Improper installation work can cause an injury by the falling down of the unit. Take a proper measure to suppress the critical concentration of refrigerant if leaked when installing the unit in a small room. The limit density is made not to be exceeded even if the refrigerant leaks by any chance. You are necessary to ventilation measures to prevent the accident. If the refrigerant leaks, hypoxia accident may caused. For the countermeasure to be taken, consult your dealer. The outdoor unit must be installed on stable, level surface, in a place where there is no accumulation of snow , leaves or rubbish. The outdoor unit should be installed in a location where air and noise emitted by the unit will not disturb the neighbors. The indoor unit should be securely installed. If the unit is loosely mounted, it may fall, and cause injury. The terminal block cover of unit must be firmly attached to prevent entry of dust and moisture. Improper mounting of the cover cause electric shock or fire. The heating of refrigerant is noted. When the refrigerant touches the fire etc., it was decomposed and a poisonous gas is generated. Do not use the welding machine etc., in the room close up of the installation of the air conditioner. Use only optional parts authorised by Mitsubishi Electric. If the accessories are installed improperly, water leakage, electric shock or fire may result. Ask your dealer or an authorised company to install them. -2- Caution Arrange the configuration of wiring not to bring up the panel and terminal cover, and fasten the panel and terminal cover securely. The poor mounting of the panel or terminal cover may cause the heat generation of the terminal connection, a fire or electrical shock. Never install on the place where a combustible gas might leak. The gas may ignite or explode when the gas leaks and collects in surround of the unit. When the unit is installed at telecommunication centers or hospitals, take a proper provision against noise. The erroneous operation of air conditioner may be induced by inverter equipment, independent power device, medical equipment or communication equipment. Do not wash the unit with water. If washed with water, electric shock may be caused. Do not handle the switch with wet hands. Otherwise electric shock can be resulted. Be very careful about unit transportation. The unit should not be carried by only one person if it is more than 20kg. It occasionally causes the damage of the unit and health to be impaired. Some unit use PP bands for packing. Do not use any PP band for delivery purpose. It may cause the injury. Do not touch the heat exchanger fins with your bear hands. Doing so may cut your hands. When carrying in outdoor unit, be sure to support it at four points. Carrying in and lifting with 3-point support may make outdoor unit unstable, resulting in a fall of it. Be sure to safety dispose the packing materials. Packing materials, such as catches and other metal or wooden parts, may cause stabs or other injuries. For special use as for foods, animals/plants, precision equipment or art objects, the applicability should be confirmed beforehand. As the use for the applications other than that designed originally may result in the deterioration of the quality. Consult your dealer in this regard. Do not use the unit under a special atmosphere. Installing the unit at the following places may cause a trouble, a place where is much machine oil, salt , humidity or dust, spa district, a place full of sulfur gas, volatile gas, or corrosive gas, a place near high frequency processing machine. Thermal insulation of the drain pipes is necessary prevent dew condensation. If the drain pipes are not properly insulated, condensation will result and drip on ceiling, floor or other possessions. Do not leave the mounting base being damaged. The damaged base may cause the falling down of the unit which may give injury. The unit should be securely installed level surface. When the unit inclines, it causes the water leak and the breakdown. Please confirm the horizontal with the spirit level. Turn on the main power switch more than 6 hours before starting operation. Do not turn the main power switch OFF during seasons of heavy use, doing so can result in failure. Install drain piping (hose) according to this Installation Manual to ensure proper drainage. Improper drain piping (hose) may cause water leakage and damage to furniture or other possessions. Do not touch the compressor or refrigerant piping without wearing glove on your hands. Touching directly such part can cause a burn or frostbite as it becomes high or low temperature according to the refrigerant state. The unit must be properly earth connected. Do not connect the earth wire to gas pipe, city water pipe, lightning rod or telephone earth wire. Improper earth connection may cause electrical shock. Do not touch the metal edges inside the unit without wearing glove on your hands. Touching directly it may injure your hands. When installing at a watery place, provide an electric leak breaker. Failure to mount the electric leak breaker may cause electrical shock. Do not remove the panel or the fan guard from the unit when it is running. You could be injured if you touch rotating, hot or highvoltage parts. Use breaker or fuse with proper capacity. Make sure that each appliance has a main power switch. Using a wire or copper wire instead of proper capacity can cause fire or trouble. Other appliances connected to the same line could cause an overload. Do not operate the air conditioner without the air filter set place. Dust may accumulate, and cause a failure. For the power lines, use standard cables of sufficient current capacity. Otherwise, current leakage, overheating or fire may occur. At emergency (if you smell something burning), stop operation and turn the power source switch off. Continuing the operation without eliminating the emergency state may cause a machine trouble, fire, or electrical shock. After stopping operation, be sure to wait for five minutes before turning off the main power switch. Otherwise, water leakage or unit failure may occur. When installing the power lines, do not apply tension to the cables. The tighten or loosen the connections may cause generate heat and cause fire. Remote controller is not installed for the place where direct sunshine strikes. Remote controller should be pushed with finger Remote controller may be broken. Do not place objects under the units to avoid damage of condensation. When the room is high humidity or when the drain pipe is clogged, water may drip from the indoor unit. -3- A COMPLETE LINE UP Cooling capacity Heating capacity (PEH only) PEH-5 PE(H)-7 PE(H)-8 PE(H)-10 PE-15/PEH-15 PE(H)-20 kW 14.4 17.9 22.0 28.8 47.0/44.0 57.6 Btu/h 49,150 61,100 75,100 98,300 160,400/150,200 196,600 kcal/h 12,400 15,400 18,900 24,800 40,500/37,900 49,500 kW 14.4 18.8 22.0 28.8 44.0 57.6 Btu/h 49,150 64,100 75,100 98,300 150,200 196,600 kcal/h 12,400 16,200 18,900 24,800 37,900 49,500 Note: Cooling & heating capacities are based following conditions. Cooling: Indoor:27 DB, 19 WB; Outdoor: 35 DB Heating: Indoor:21 DB; Outdoor: 7 DB, 6 WB (PEH only) Cooling and Heating capacities are based 5m pipe length Indoor unit Example PEH-8 Outdoor unit Example PUH-8 -4- FEATURES Highly efficient operation Labour saving installation The EER(Energy Efficiency Ratio) on these models is greatly improved by revised design specifications and by being manufactured stringently to Mitsubishi Electric high quality standards. The unit operation can commence immediately after connecting to the power supply, refrigerant piping, drain piping, ducting and control system. Wide electrical control capability Comfort heating (PEH only) All models are flexible mechanical control configulation. In addition Global Remote Controller is prepared on standard. The Global Remote Controller give the below function. • Cool/Heat/Fan/Auto Changeover 3 pattern select (Change to switch inside R/C) · Cool/Fan · Cool/Heat/Fan · Cool/Heat/Fan/Auto Changeover (Heat and Auto Change over one only PEH) • 2 step control (PE(H)-15, 20 only) • Compressor Anti-short cycle timer (3 min) • Programmable weekly timer ON/OFF time setteing on 7-days • Real time clock • Built in Return air temperature Sensor (Option : Outside sensor) • Power failure comeback • Error indicator · Room temperature sensor Error • Key Lock Key lock except ON/OFF key The PEH models are designed to provide effective heating even when the outside temperature is down to -10˚C. High sensible cooling capacity The sensible cooling capacity has been significantly improved through balanced optimised heat exchanger design. Flexibility of Supply Air Delivery PE, PEH-15,20 feature belt driven Supply Air fans enabling accurate matching of actual airflow rates to the specified quantities. Accurate commissioning is assisted by the capability to change pulleys and belts if necessary to achieve the desired air balance. Low ambient cooling (Special order) In applications with relatively high internal loads, there may be a requirement for all series to operate on cooling at low ambient conditions. Special order parts is available to maintain the refrigeration circuit in balance at outdoor temperatures as low as -5˚C. Please consult your local Mitsubishi Electric Sales office for application advice on these parts. Grobal Remote Controller DESCRIPTIONS With the development of all series demands for such features as light weight, compactness, increased capacity, appropriate static pressure, air flow control, and having flexibility of inter facing energy saving electronic controls, Mitsubishi Electric have met market expectations. Mitsubishi Electric air conditioners series PE(H)/PU(H) are available in a wide range of sizes and models to enables the designer to select the best model for each application. All series units are completely assembled, wired and strictly tested at the factory. - 5- MECHANICAL SPECIFICATIONS General Condenser Coils All units are factory assembled, piped, internally wired. They are also tested and checked under a strict quality control system in the factory. Exterior surfaces of all units of outdoor unit are phosphatized, zinc-coated steel with powder coating and ivory white baked enamel finish. Unnecessary power input due to higher discharge pressure is avoided by high performance designs of cross-finned coil. Condenser coils are made of 9.52mm OD, 0.35mm thick seamless copper tubes mechanically bonded to 0.12mm thick aluminium fins and factory pressure and leak tested at 3.3MPa. Refrigeration Controls Refrigeration controls include condenser fan, evaporator fan and compressor contactors. Compressors All units have high efficiency type hermetic line starting compressors. Compressors are equipped with thermal overload protector, over-current relay and high pressure protection control. Crankcase heaters are standard. Evaporator Fans The sirocco fans are made of galvanized steel or plastic and balanced to proved accurate air flow performance at low noise level. Condenser Fan The direct-drive propeller fan is dynamically balanced, to ensure smooth airflow. A weatherproof three-phase squirrel cage induction motor is used to drive the condenser fan. Evaporator Coils Highly efficient cross-finned coil are applied to provide a larger cooling capacity with low air speed on the coil. Coils are made of 9.52mm OD and 0.35mm thick seamless copper tubing mechanically bonded to 0.12mm thick aluminium fins and are factory leak tested at a pressure of 3.3MPa. They are provided with strainers attached to the capillary tubes to further ensure a clean system. TYPICAL INSTALLATION EXAMPLE PU(H) PE(H) PE(H) PU(H) - 6- MODEL-DESIGNATION BREAKDOWN P E - 10 M Y C 1 Service reference Design Sequence Electrical Supply Y = 3 phase 380~415V 50Hz 4 wires of PE(H)-7 Indoor unit ( InY =case 1 phase 220~240V 50Hz 2 wires ) Compressor Horsepower 5 = 5 HP 7 = 7 HP 8 = 7.5 HP 10= 10 HP 15= 15 HP 20= 20 HP Series Number PE = Indoor unit PEH = Indoor unit PU = Outdoor unit PUH = Outdoor unit -7- SPECIFICATIONS Cooling only PE-7~20MYC PE-7MYC PE-8MYC PE-10MYC PE-15MYC PE-20MYC PE-7MYC-EU PE-8MYC-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU kW Btu/h kcal/h 17.9 61,100 Sensible cooling capacity (Gross) kW Btu/h kcal/h 14.3 48,800 22.0 75,100 18,900 17.6 60,100 15,100 28.8 98,300 24,800 23.0 78,500 19,800 47.0 160,400 40,400 37.6 128,300 32,300 57.6 196,600 49,500 46.1 157,300 39,600 Total cooling capacity (Net) kW Btu/h kcal/h 17.2/17.1 58,700/58,300 21.4 73,000 18,400 27.8 94,900 23,900 45.5/45.3 155,200/154,600 39,100/39,000 56.1/55.2 191,400/188,300 48,200/47,500 Model name Service reference Total cooling capacity (Gross) Power supply kg Service reference Width Depth Height Net weight Indoor coil Indoor fan Indoor fan motor Motor output Indoor fan air flow External static pressure Sound pressure level Drain connection Outdoor unit Model name mm mm mm kg Width Depth Height Net weight Compressor No. ✕ Motor output Crankcase heater Outdoor coil Outdoor fan Outdoor fan motor No. ✕ Motor output Outdoor fan air flow Sound pressure level Protection devices 3N~ 380~415V 50Hz 3N~ 380~415V 50Hz 0-100 0-50-100 5.7 5.0 R-22 8.7 Capillary tube PE-7MYC PE-8MYC PE-10MYC PE-15MYC PE-20MYC PE-7MYC-EU PE-8MYC-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU Galvanized steel 1,615 1,690 1,415 67 650 428 70 2 ✕ 4.8 2 ✕ 9.7 1,993 865 706 84 180 212 Cross fin coil Centrifugal (plastic) - Direct drive Centrifugal (plastic) - Belt drive Three phase induction motor Single phase induction motor 3.7 0.7 1.0 kW 2.2 0.21 CMM 60 70 90 140 180 CFM 2,119 2,472 3,179 4,945 6,358 L/S 1,000 1,167 1,500 2,333 3,000 5/12.5 mmAq 10/20 6.2/12.5 50/125 Pa 62/125 100/200 55 56 59 61 62 dB(A) mm 25.4 Service reference External finish Dimension 14,800/14,700 % Refrigerant control Indoor Unit Model name External finish Dimension 12,300 ~ 220~240V 50Hz 3N~ 380~415V 50Hz Indoor Outdoor Capacity step Refrigerant Refrigerant charge 15,400 PU-7MYC PU-8MYC PU-7MYC1-EU(S) PU-8MYC1-EU(S) kW W kW CMM CFM L/S dB(A) PU-15MYC 202 1 ✕ 5.0 62 205 230 285 Hermetic line start(reciprocating) 1 ✕ 5.5 1 ✕ 7.5 2 ✕ 5.5 62 72 2 ✕ 62 Cross fin coil Propeller-Direct drive Three phase induction motor 2 ✕ 0.09 2 ✕ 0.15 190 210 220 6,711 7,415 7,770 3,167 3,000 3,667 65 65 65 High pressure switch, freeze & frost protection, Fuse Over current relay (comp & indoor fan, outdoor fan) Internal thermostat (comp & indoor fan, outdoor fan) 1 ✕ 0.24 240 8,477 4,000 67 Note1. Cooling capacity and sound pressure level are based on the following conditions. Indoor;27˚CDB,19˚CWB, Outdoor;35˚CDB Cooling capacity is based 5m pipe length. 2. Refergirant charge volumes are factory charged (at 5m piping length).Refrigerant is enclosed with the outdoor unit. 3. Gross capacity do not include a deduction for evaporator fan motor heat. 4. The measuring point of the Sound pressure level is 1m from the unit front surface. 5. Specification subject to change without notice. -8- PU-20MYC PU-10MYC1-EU(S) PU-15MYC1-EU(S) Acrylic resin coating (Munsell 5Y 8/1) 1,400 998 700 980 1,230 mm mm mm kg PU-10MYC PU-20MYC1-EU(S) 1,996 998 961 360 2 ✕ 7.5 2 ✕ 72 2 ✕ 0.24 480 16,954 8,000 68 PEH-5,7,8MYA Model name Service reference Total cooling capacity (Gross) Heat pump kW Btu/h kcal/h Sensible cooling capacity (Gross) kW Btu/h kcal/h Total cooling capacity (Net) kW Btu/h kcal/h Heating capacity (Gross) kW Btu/h kcal/h Heating capacity (Net) kW Btu/h kcal/h Power supply Indoor Outdoor Capacity step Refrigerant Refrigerant charge Refrigerant control Indoor Unit Model name PEH-7MYA PEH-8MYA PEH-5MYA-EU PEH-7MYA-EU PEH-8MYA-EU 14.4 49,100 12,400 11.5 39,200 9,900 13.9 47,400 12,000 17.9 61,100 15,400 14.3 48,800 12,300 17.2/17.1 58,700/58,300 14,800/14,700 22.0 75,100 18,900 17.6 60,100 15,100 21.4 73,000 18,400 13.9 47,400 12,000 14.4 49,100 12,400 3N~ 380~415V 50Hz 3N~ 380~415V 50Hz 18.0 61,400 15,500 18.7/18.8 63,800/64,100 16,100/16,200 ~ 220~240V 50Hz 3N~ 380~415V 50Hz 21.4 73,000 18,400 22.0 75,100 18,900 3N~ 380~415V 50Hz 3N~ 380~415V 50Hz 0-100 R-22 % kg 5.0 5.7 6.6 Capillary tube Service reference External finish Dimension PEH-5MYA PEH-5MYA PEH-7MYA PEH-8MYA PEH-5MYA-EU PEH-7MYA-EU PEH-8MYA-EU Galvanized steel Width Depth Height Net weight Indoor coil Indoor fan Indoor fan motor Motor output Indoor fan air flow External static pressure Sound pressure level Drain connection Outdoor unit Model name Service reference External finish Width Dimension Depth Height Net weight Compressor Motor output Crankcase heater Outdoor coil Outdoor fan Outdoor fan motor No. ✕ Motor output Outdoor fan air flow Sound pressure level Protection devices mm mm mm kg 1,095 1,415 650 428 60 67 70 Cross fin coil Centrifugal (plastic) - Direct drive Three phase induction motor Three phase induction motor Single phase induction motor kW CMM CFM L/S mmAq Pa dB(A) mm 0.45 42 1,483 700 0.7 70 2,472 1,167 6.2/12.5 62/125 56 5/12.5 50/125 55 25.4 PUH-5MYE PUH-7MYC PUH-8MYC PUH-8MYE PUH-5MYE1-EU PUH-7MYC2-EU PUH-8MYC2-EU PUH-8MYE1-EU mm mm mm 1,000 550 1,175 kg 150 kW W 3.73 kW CMM CFM L/S dB(A) 0.21 60 2,119 1,000 Acrylic resin coating (Munsell 5Y 8/1) 1,400 700 980 214 211 Hermetic line start(reciprocating) 5.5 62 Cross fin coil Propeller-Direct drive Three phase induction motor 1 ✕ 0.15 2 ✕ 0.09 95 167 3,355 5,898 1,583 2,783 57 65 High pressure switch, freeze & frost protection, Fuse Over current relay (comp & indoor fan, outdoor fan) Internal thermostat (comp & indoor fan, outdoor fan) Note 1. Cooling, heating capacities and sound pressure level are based on the following conditions. Cooling indoor; 27˚CDB, 19˚CWB, outdoor :35˚CDB Heating indoor; 21˚CDB, outdoor :7.0˚CDB, 6.0˚CWB Cooling and heating capacities are based 5m pipe length. 2. Refergirant charge volumes are factory charged (at 5m piping length).Refrigerant is enclosed with the outdoor unit. 3. Gross capacity do not include a deduction for evaporator fan motor heat. 4. The measuring point of the Sound pressure level is 1m from the unit front surface. 5. Specification subject to change without notice. -9- 1,250 550 1,175 188 1 ✕ 0.35 200 7,063 3,333 65 PEH-10,15,20MYA Heat pump Model name Service reference Total cooling capacity (Gross) kW Btu/h kcal/h Sensible cooling capacity (Gross) kW Btu/h kcal/h kW Btu/h kcal/h Total cooling capacity (Net) Heating capacity (Gross) kW Btu/h kcal/h Heating capacity (Net) kW Btu/h kcal/h Power supply PEH-15MYA PEH-20MYA PEH-10MYA-EU PEH-15MYA-EU PEH-20MYA-EU 27.8 94,900 23,900 27.8 94,900 23,900 27.8 94,900 44.0 150,200 37,900 35.2 120,200 30,200 42.5/41.7 145,000/142,300 36,600/35,900 41.7 142,300 35,900 43.2/44.0 147,400/37,200 150,100/37,800 3N~ 380~415V 50Hz 3N~ 380~415V 50Hz 23,900 27.8 94,900 23,900 28.8 98,300 24,800 Indoor Outdoor Capacity step Refrigerant Refrigerant charge Refrigerant control Indoor Unit Model name 57.6 196,600 49,500 46.0 157,000 39,600 56.1/55.1 191,400/188,000 48,200/47,400 55.1 188,000 47,400 56.6/57.6 193,100/196,500 48,700/49,500 0-100 % 0-50-100 R-22 kg 9.9 2 ✕ 9.7 2 ✕ 6.6 11.0 Capillary tube Service reference External finish Dimension PEH-10MYA PEH-10MYA PEH-15MYA PEH-20MYA PEH-10MYA-EU PEH-15MYA-EU PEH-20MYA-EU Galvanized steel Width Depth Height Net weight Indoor coil Indoor fan Indoor fan motor Motor output Indoor fan air flow External static pressure Sound pressure level Drain connection Outdoor unit Model name Service reference External finish Width Dimension Depth Height Net weight Compressor No. ✕ Motor output Crankcase heater Outdoor coil Outdoor fan Outdoor fan motor No. ✕ Motor output Outdoor fan air flow Sound pressure level Protection devices mm mm mm kg 1,615 650 428 84 1,690 1,993 865 706 180 212 Cross fin coil kW CMM CFM L/S mmAq Pa Centrifugal (plastic) - Direct drive Centrifugal (plastic) - Belt drive Three phase induction motor 1.0 2.2 3.7 140 180 90 4,945 6,358 3,179 1,500 2,333 3,000 10/20 6.2/12.5 62/125 59 dB(A) mm 62 25.4 PUH-10MYC PUH-10MYE PUH-15MYC PUH-20MYC PUH-10MYC2-EU PUH-10MYE1-EU PUH-15MYC2-EU PUH-20MYC2-EU mm mm mm 1,400 700 980 kg 240 Acrylic resin coating (Munsell 5Y 8/1) 1,250 550 1,175 431 221 1 ✕ 7.5 72 kW W kW CMM CFM L/S dB(A) 100/200 61 472 Hermetic line start(reciprocating) 2 ✕ 5.5 2 ✕ 62 Cross fin coil Propeller-Direct drive Three phase induction motor 0.35 200 7,063 3,333 2 ✕ 0.15 190 6,711 3,167 1,951 1,080 1,200 65 2 ✕ 7.5 2 ✕ 72 2 ✕ 0.35 2 ✕ 185 2 ✕ 6,534 2 ✕ 3,083 69 High pressure switch, freeze & frost protection, Fuse Over current relay (comp & indoor fan, outdoor fan) Internal thermostat (comp & indoor fan, outdoor fan) Note 1. Cooling, heating capacities and sound pressure level are based on the following conditions. Cooling indoor; 27˚CDB, 19˚CWB, outdoor :35˚CDB Heating indoor; 21˚CDB, outdoor :7.0˚CDB, 6.0˚CWB Cooling and heating capacities are based 5m pipe length. 2. Refergirant charge volumes are factory charged (at 5m piping length).Refrigerant is enclosed with the outdoor unit. 3. Gross capacity do not include a deduction for evaporator fan motor heat. 4. The measuring point of the Sound pressure level is 1m from the unit front surface. 5. Specification subject to change without notice. - 10 - ELECTRICAL DATA PE-7~20MYC-EU Cooling VOLT PE-7 240V PE8~20 415V PE-7 230V PE8~20 400V PE-7 220V PE8~20 380V ITEM PE-7MYC-EU PE-8MYC-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU PU-7MYC1-EU PU-8MYC1-EU PU-10MYC1-EU PU-15MYC1-EU PU-20MYC1-EU 17.4/17.6 10.1 7.8 21.1/22.0 7.1/7.2 29.1/29.6 19.0 14.2 37.3/39.1 14.2/14.6 83 74 76 78 119 82 83 140 74 2 × 9.2 2 × 7.65 8.6 6.8 6.0 ×15.95 2 16.0 12.3 10.7 2 × 12.45 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A COMPRESSOR INPUT RUN CURRENT INDOOR side External static pressure kW A Pa 50/125 62/125 62/125 100/200 100/200 INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 0.7/0.8 2.8/3.2 0.4 0.7 0.6 1.2 0.4 0.7 1.0 2.0 0.5 1.0 1.5/1.7 3.1/3.5 0.6 1.2 1.5/2.4 3.0/4.8 2 × 0.6 2 × 1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 7.1/7.2 14.7/15.2 77 7.8 14.7 77 86 10.1 19.6 74 85 17.4/17.6 30.2/30.6 83 123 21.1/22.0 38.7/40.5 79/78 145 COMPRESSOR INPUT RUN CURRENT INDOOR side External static pressure kW A 6.0 11.1 6.8 12.8 8.6 16.6 2X7.65 2X12.9 2X9.2 2X16.6 Pa 50/125 62/125 62/125 100/200 100/200 INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 0.7/0.8 2.9/3.4 0.4 0.7 0.6 1.2 0.4 0.7 1.0 2.0 0.5 1.0 1.5/1.7 3.2/3.6 0.6 1.2 1.5/2.4 3.1/4.9 2X0.6 2X1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 7.1/7.2 15.5/15.9 81 7.8 15.5 76 91 10.1 20.7 74 90 17.4/17.6 31.8/32.3 83 131 21.1/22.0 40.8/42.7 78 152 COMPRESSOR INPUT RUN CURRENT INDOOR side External static pressure kW A 6.0 11.6 6.8 13.4 8.6 17.6 2 × 7.65 2 × 13.65 2 × 9.2 2 × 17.55 Pa 50/125 62/125 62/125 100/200 100/200 INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 0.7/0.8 3.1/3.5 0.4 0.8 0.6 1.3 0.4 0.8 1.0 2.1 0.5 1.0 1.5/1.7 3.4/3.8 0.6 1.2 1.5/2.4 3.3/5.2 2 × 0.6 2 × 1.2 - 11 - PEH-5,7,8MYA-EU Cooling VOLT ITEM TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT PEH-7 240V COMPRESSOR INPUT RUN CURRENT PEH- INDOOR side 5, 8 External static pressure 415V INDOOR FAN INPUT kW A % A kW A PEH-5MYA-EU PEH-7MYA-EU PEH-8MYA-EU PUH-5MYE1-EU PUH-7MYC2-EU PUH-8MYC2-EU PUH-8MYE1-EU 7.8 7.9 5.49 7.1/7.2 14.2 14.7 9.6 14.2/14.6 76 75 80 83 83 69 74 6.8 6.8 4.7 6.0 12.3 12.3 8.1 10.7 Pa 50/125 50/125 62/125 62/125 RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 0.54 1.0 0.25 0.5 0.7/0.8 2.8/3.2 0.4 0.7 0.6 1.2 0.4 0.7 0.6 1.2 0.5 1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 5.49 10.0 79 72 7.1/7.2 14.7/15.2 77 7.8 14.7 77 86 7.9 15.2 75 86 kW A 4.7 8.5 6.0 11.1 6.8 12.8 6.8 12.8 Pa 50/125 50/125 62/125 62/125 RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 0.54 1.0 0.25 0.5 0.7/0.8 2.9/3.4 0.4 0.7 0.6 1.2 0.4 0.7 0.6 1.2 0.5 1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 5.49 10.6 80 75 7.1/7.2 15.5/15.9 81 7.8 15.5 76 91 7.9 16.0 75 91 kW A 4.7 8.9 6.0 11.6 6.8 13.4 6.8 13.4 Pa 50/125 50/125 62/125 62/125 kW A kW A 0.54 1.1 0.25 0.6 0.7/0.8 3.1/3.5 0.4 0.8 0.6 1.3 0.4 0.8 0.6 1.3 0.5 1.3 PEH-7 230V COMPRESSOR INPUT RUN CURRENT PEH- INDOOR side 5, 8 External static pressure 400V INDOOR FAN INPUT PEH-7 220V COMPRESSOR INPUT RUN CURRENT PEH- INDOOR side 5, 8 External static pressure 380V INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT - 12 - PEH-5,7,8MYA-EU Heating VOLT ITEM TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT PEH-7 240V COMPRESSOR INPUT RUN CURRENT PEH- INDOOR side 5, 8 External static pressure 415V INDOOR FAN INPUT kW A % A kW A PEH-5MYA-EU PEH-7MYA-EU PEH-8MYA-EU PUH-5MYE1-EU PUH-7MYC2-EU PUH-8MYC2-EU PUH-8MYE1-EU 6.5 4.5 6.6 6.2/6.3 12.4 8.6 12.9 13.2/13.6 73 73 71 83 69 83 74 5.5 3.71 5.5 5.1 10.5 7.1 10.5 9.7 Pa 50/125 50/125 62/125 62/125 RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 0.54 1.0 0.25 0.5 0.7/0.8 2.8/3.2 0.4 0.7 0.6 1.2 0.4 0.7 0.6 1.2 0.5 1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 4.5 8.9 73 72 6.2/6.3 13.7/14.2 77 6.5 12.8 73 86 6.6 13.4 71 86 kW A 3.71 7.4 5.1 10.1 5.5 10.9 5.5 11.0 Pa 50/125 50/125 62/125 62/125 RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 0.54 1.0 0.25 0.5 0.7/0.8 2.9/3.4 0.4 0.7 0.6 1.2 0.4 0.7 0.6 1.2 0.5 1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 4.5 9.5 72 75 6.2/6.3 14.5/14.9 81 6.5 13.6 73 91 6.6 14.1 71 91 kW A 3.71 7.8 5.1 10.6 5.5 11.5 5.5 11.5 Pa 50/125 50/125 62/125 62/125 kW A kW A 0.54 1.1 0.25 0.6 0.7/0.8 3.1/3.5 0.4 0.8 0.6 1.3 0.4 0.8 0.6 1.3 0.5 1.3 PEH-7 230V COMPRESSOR INPUT RUN CURRENT PEH- INDOOR side 5, 8 External static pressure 400V INDOOR FAN INPUT PEH-7 240V COMPRESSOR INPUT RUN CURRENT PEH- INDOOR side 5, 8 External static pressure 380V INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT - 13 - PEH-10,15,20MYA-EU Cooling VOLT PEH10~20 415V PEH10~20 400V PEH10~20 380V ITEM PEH-10MYA-EU PEH-15MYA-EU PEH-20MYA-EU PUH-10MYC2-EU PUH-10MYE1-EU PUH-15MYC2-EU PUH-20MYC2-EU 16.1/16.9 10.1 10.2 20.8/21.8 29.5/30.9 19.0 19.3 37.4/39.3 76 74 74 77 119 82 82 140 2 × 9.15 2 × 6.8 8.6 8.7 2 × 16.1 16.0 16.1 2 × 12.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A COMPRESSOR INPUT RUN CURRENT INDOOR side External static pressure kW A Pa 62/125 62/125 100/200 100/200 INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 1.0 2.0 0.5 1.0 1.0 2.0 0.5 1.2 1.5/2.3 2.7/4.1 2 × 0.5 2 × 1.2 1.5/2.5 2.8/4.7 2 × 0.5 2 × 1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 10.1 19.6 74 85 10.2 19.9 74 85 16.1/16.9 30.6/32.1 76 123 20.8/21.8 38.8/40.8 77 145 COMPRESSOR INPUT RUN CURRENT INDOOR side External static pressure kW A 8.6 16.6 8.7 16.7 2 × 6.8 2 × 12.7 2 × 9.15 2 × 16.75 Pa 62/125 62/125 100/200 100/200 INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 1.0 2.0 0.5 1.0 1.0 2.0 0.5 1.2 1.5/2.3 2.8/4.3 2 × 0.5 2 × 1.2 1.5/2.5 2.9/4.9 2 × 0.5 2 × 1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 10.1 20.7 68 90 10.2 21.0 68 90 16.1/16.9 32.1/33.7 70 131 20.8/21.8 40.9/42.9 71 152 COMPRESSOR INPUT RUN CURRENT INDOOR side External static pressure kW A 8.6 17.5 8.7 17.6 2 × 6.8 2 × 13.3 2 × 9.15 2 × 17.6 Pa 62/125 62/125 100/200 100/200 INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 1.0 2.1 0.5 1.1 1.0 2.1 0.5 1.3 1.5/2.3 2.9/4.5 2 × 0.5 2 × 1.3 1.5/2.5 3.1/5.1 2 × 0.5 2 × 1.3 - 14 - PEH-10,15,20MYA-EU Heating VOLT PEH10~20 415V PEH10~20 400V PEH10~20 380V ITEM PEH-10MYA-EU PEH-15MYA-EU PEH-20MYA-EU PUH-10MYC2-EU PUH-10MYE1-EU PUH-15MYC2-EU PUH-20MYC2-EU 13.7/14.5 8.3 8.6 16.2/17.2 25.5/26.9 16.1 16.4 31.3/33.2 75 72 73 72 115 82 82 136 2 × 5.6 6.8 7.1 2 × 6.85 13.1 13.2 2 × 10.2 2 × 13.05 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A COMPRESSOR INPUT RUN CURRENT INDOOR side External static pressure kW A Pa 62/125 62/125 100/200 100/200 INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 1.0 2.0 0.5 1.0 1.0 2.0 0.5 1.2 1.5/2.3 2.7/4.1 2 × 0.5 2 × 1.2 1.5/2.5 2.8/4.7 2 × 0.5 2 × 1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 8.3 16.6 72 85 8.6 16.9 73 85 13.7/14.5 26.5/28.0 75 119 16.2/17.2 32.5/34.5 72 141 COMPRESSOR INPUT RUN CURRENT INDOOR side External static pressure kW A 6.8 13.6 7.1 13.7 2 × 5.6 2 × 10.65 2 × 6.85 2 × 13.6 Pa 62/125 62/125 100/200 100/200 INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 1.0 2.0 0.5 1.0 1.0 2.0 0.5 1.2 1.5/2.3 2.8/4.3 2 × 0.5 2 × 1.2 1.5/2.5 2.9/4.9 2 × 0.5 2 × 1.2 TOTAL INPUT TOTAL RUN CURRENT POWER FACTOR START CURRENT kW A % A 8.3 17.5 72 90 8.6 17.8 73 90 13.7/14.5 27.8/29.4 75 126 16.2/17.2 34.3/36.3 72 148 COMPRESSOR INPUT RUN CURRENT INDOOR side External static pressure kW A 6.8 14.3 7.1 14.4 2 × 5.6 2 × 11.15 2 × 6.85 2 × 14.25 Pa 62/125 62/125 100/200 100/200 INDOOR FAN INPUT RUN CURRENT OUTDOOR FAN INPUT RUN CURRENT kW A kW A 1.0 2.1 0.5 1.1 1.0 2.1 0.5 1.3 1.5/2.3 2.9/4.5 2 × 0.5 2 × 1.3 1.5/2.5 3.1/5.1 2 × 0.5 2 × 1.3 - 15 - SELECTION PROCEDURE 1. Model Selection (With actual examples) First step, to select the approximate model: Based on the cooling load and the cooling capacity listed in the capacity table, select the applicable model. Second step, to select the model: To select the model, the following conditions must be known: (1) Total cooling load or sensible cooling load (2) Indoor conditioned temperature (WB*1, DB) (3) Designed outdoor temperature (DB)*2 (4) Designed air flow (5) Designed external static pressure (= Wind pressure loss of air duct)*3 Notes: *1. The correct WB is required since it has a serious effect on the capacity. *2. The cooling capacity decreases as the outdoor temperature increases. Therefore, the estimated highest temperature during an air conditioning time frame is the "designed outdoor temperature". However, it is recommended that the abnormal outdoor temperature which may occur once or twice a year be excluded from the calculation to avoid selection of an excessively large capacity model. *3. The wind pressure loss of an air duct should be calculated correctly. If a value having an excessive allowance is used, an excessively large model will be selected. Moreover, an excessively high air flow will be induced during actual operation causing the generation of high operating sounds and carry-over of condensed water. (Step-1) Confirmation of operation range Confirm that the conditions given above for the model to be selected are within the operation range listed on Page 37. (Step-2) Calculation of actual air flow, external static pressure, and fan motor input Based on the designed air flow and external static pressure, obtain the actual air flow, actual external static pressure, and fan motor power input from the fan performance table for the model selected. For an explanation of how to use the fan performance table, see the following examples. Example: PE-8MYC, 50Hz Example 1. (To operate with values near to the designed air flow and external static pressure.) Condition : Designed air flow 70CMM Designed external static pressure 60Pa Calculation : The designed point is A. Therefore, duct resistance line passing A is dotted line. Fan Performance Curve 50Hz Fan speed (Pa) (rpm) Therefore, actual point is B for ∆ connection 450 Recommended Range Actual air flow = 77CMM 400 For connection 1400 Actual external static pressure = 70Pa operation line 350 Note: Duct resustance line is secondary curve. 1300 Total static pressure B 300 1200 A 250 60Pa 1100 200 For connection operation line 1000 150 100 Inte rn P al S 900 50 800 0 50 - 16 - 55 60 65 70 Air flow (CMM) 75 77 80 (Step-3) Calculation of net capacity Based on the indoor conditioned temperature (WB,DB), designed outdoor temperature (DB), and the actual air flow obtained in Step-2, obtain the gross capacity from the gross capacity tables (pages 18~35). Then, calculate the net capacity from the formula below by using the fan motor input obtained in Step-2. Net capacity (kW) = Gross capacity (kW) - Fan motor input (kW) Example: PE-8MYC Condition: Indoor conditioned temp. : 26˚CDB, 19˚CWB Designed outdoor temp. : 40˚CDB Actual air flow : 77CMM Fan motor input : 0.6kW (See P.11) Calculation : The sections of the gross capacity table applicable for the above conditions are shown right. OUTDOOR DB˚C INDOOR INDOOR DB˚C 40.0 WB˚C Q kW SHC kW SHF T/I kW 19 21.3 9.7 0.46 8.3 26 Factor for Various Air Flow PE-8MYC-EU COOLING At 26˚CDB, 19˚CWB of Indoor, Q = 21.3, SHC = 9.7, T/I = 8.3 AIR VOLUME CMM 60 70 80 L/S 1,000 0.976 0.991 0.963 1,167 1.0 1.0 1.0 1,330 1.025 1.009 1.044 CAPACITY TOTAL INPUT SHC Therefore, when air flow is 77(CMM) Q = 21.3 ✕ (1+(1.025 - 1.0) ✕ 7/10*) ÷ 21.7(kW) SHC = 9.7 ✕ (1+(1.044 - 1.0) ✕ 7/10*) ÷ 10.0(kW) T/I = 8.3 ✕ (1+(1.009-1.0))✕ 7/10*) ÷ 8.4(kW) Note * : 7/10 = (77-70)/(80-70) Therfore, the net capacity is, Net total cooling capacity = 21.7 (kw) - 0.6(kW) = 21.1 (kW) Net sensible cooling capacity = 10.0 (kW) - 0.6 (kW) = 9.4 (kW) 2. Efficiency Calculation • Refrigerant cycle energy efficienty • System energy efficienty (1) COP = Gross total cooling capacity (kW) Compressor input (kW) (1) COP = Net cooling capacity (kW) Compressor input (kW) (2) EER = Gross total cooling capacity (kW) Total input (kW) (2) EER = Net cooling capacity (kW) Total input (kW) 1kW = 3412Btu/h Notes: 1. COP : Coefficient of performance 2. EER : Energy efficiency ratio 3. Temperature condition of COP, EER (ARI Standard Ratings) Indoor entering air temp. : 80˚FDB (=27˚CDB), 66˚FWB(=19˚CWB) Outdoor entering air temp. : 95˚FDB (=35˚CDB) 4. Total input = Compressor input + Indoor fan motor input + Outdoor fan motor input (page 11). - 17 - - 18 - 19.0 24 17.3 21 18.5 17.3 20 23 19.0 24 17.9 18.5 23 22 17.9 17.3 20 22 16.1 19 17.3 18.5 23 21 17.9 22 16.1 19 17.3 15.6 18 21 17.3 21 17.3 17.3 20 20 16.1 15.0 17 19 14.5 16 15.6 16.1 19 18 15.6 14.5 16 18 13.9 15 15.0 15.0 17 17 14.5 13.9 15 16 Q kW WB ˚C 7.3 8.6 9.9 11.2 12.4 4.8 6.2 7.5 8.9 10.1 12.1 3.7 4.8 6.2 7.4 9.1 10.6 3.8 5.1 6.7 8.0 9.3 11.0 3.9 5.2 6.8 8.3 10.1 4.2 5.5 7.2 SHCkW 20.0 4.8 4.8 4.7 4.7 4.6 4.8 4.8 4.7 4.7 4.6 4.6 4.8 4.7 4.7 4.6 4.6 4.5 4.7 4.6 4.6 4.5 4.5 4.5 4.6 4.5 4.5 4.5 4.4 4.5 4.5 4.4 T/I kW 18.5 18.0 17.4 16.8 16.8 18.5 18.0 17.4 16.8 16.8 15.6 18.0 17.4 16.8 16.8 15.6 15.1 16.8 16.8 15.6 15.1 14.6 14.1 15.6 15.1 14.6 14.1 13.5 14.6 14.1 13.5 Q kW 7.2 8.5 9.6 11.0 12.2 4.7 6.1 7.3 8.7 10.0 12.0 3.6 4.7 6.1 7.3 8.9 10.4 3.7 5.0 6.6 7.9 9.1 10.9 3.8 5.2 6.7 8.2 9.9 4.1 5.4 7.0 SHCkW 25.0 0.39 0.47 0.55 0.66 0.73 0.26 0.34 0.42 0.52 0.59 0.77 0.20 0.27 0.36 0.43 0.57 0.69 0.22 0.30 0.42 0.52 0.62 0.77 0.24 0.34 0.46 0.58 0.73 0.28 0.38 0.52 SHF AIR VOLUME CAPACITY TOTAL INPUT SHC PEH-5MYA-EU COOLING 35 584 0.969 0.989 0.967 CMM L/S 700 1.0 1.0 1.0 42 SHC:SENSIBLE HEAT CAPACITY 0.38 0.46 0.55 0.65 0.72 0.25 0.33 0.42 0.51 0.59 0.75 0.20 0.27 0.36 0.43 0.57 0.68 0.22 0.29 0.42 0.52 0.62 0.76 0.24 0.34 0.45 0.57 0.72 0.28 0.38 0.52 SHF Factor for Various Air Flow Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR PEH-5MYA-EU 17.9 17.3 16.8 16.2 16.2 17.9 17.3 16.8 16.2 16.2 15.1 17.3 16.8 16.2 16.2 15.1 14.6 16.2 16.2 15.1 14.6 14.1 13.6 15.1 14.6 14.1 13.6 13.1 14.1 13.6 13.1 Q kW 7.0 8.3 9.6 10.8 12.0 4.7 6.0 7.2 8.6 9.8 11.9 3.6 4.6 6.0 7.1 8.8 10.3 3.6 4.8 6.4 7.7 9.0 10.7 3.7 5.0 6.5 7.9 9.7 4.0 5.2 6.9 SHCkW 30.0 0.39 0.48 0.57 0.67 0.74 0.26 0.35 0.43 0.53 0.61 0.79 0.21 0.28 0.37 0.44 0.58 0.70 0.22 0.30 0.42 0.53 0.63 0.79 0.25 0.34 0.46 0.58 0.74 0.28 0.39 0.53 SHF 13.5 14.0 14.4 13.0 13.5 14.0 14.4 15.5 15.5 14.0 14.4 15.5 15.5 16.0 16.6 14.4 15.5 15.5 16.0 16.6 17.1 15.5 15.5 5.0 5.1 5.1 5.0 5.0 5.1 5.1 5.2 5.2 5.1 5.1 5.2 5.2 5.3 5.4 5.1 5.2 5.2 5.3 5.4 5.4 5.2 5.2 17.1 13.0 5.0 5.4 12.6 4.9 16.6 13.5 5.0 5.4 13.0 5.0 16.0 12.6 4.9 5.3 Q kW T/I kW OUTDOOR DB˚C 35.0 6.9 8.1 9.3 10.6 11.7 4.6 5.9 7.0 8.4 9.7 11.7 3.4 4.5 5.8 6.9 8.5 10.0 3.5 4.6 6.2 7.5 8.7 10.4 3.6 4.9 6.3 7.8 9.5 3.8 5.0 6.7 SHCkW 0.40 0.49 0.58 0.68 0.75 0.27 0.35 0.44 0.54 0.62 0.81 0.21 0.28 0.37 0.44 0.59 0.71 0.22 0.30 0.43 0.54 0.65 0.80 0.25 0.35 0.47 0.60 0.76 0.28 0.39 0.53 SHF 12.8 13.3 13.7 12.4 12.8 13.3 13.7 14.7 14.7 13.3 13.7 14.7 14.7 15.2 15.7 13.7 14.7 14.7 15.2 15.7 16.3 14.7 14.7 5.4 5.4 5.5 5.3 5.4 5.4 5.5 5.5 5.6 5.4 5.5 5.5 5.6 5.7 5.8 5.5 5.5 5.6 5.7 5.8 5.8 5.5 5.6 16.3 12.4 5.3 5.8 12.0 5.3 15.7 12.8 5.4 5.8 12.4 5.3 15.2 12.0 5.3 5.7 Q kW T/I kW 834 1.025 1.009 1.028 50 T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 125Pa”.) 5.1 5.1 5.0 4.9 4.9 5.1 5.1 5.0 4.9 4.9 4.8 5.1 5.0 4.9 4.9 4.8 4.8 4.9 4.9 4.8 4.8 4.7 4.7 4.8 4.8 4.7 4.7 4.6 4.7 4.7 4.6 T/I kW Cooling Capacity (Standard Air Flow) 40.0 6.6 7.9 9.1 10.3 11.5 4.3 5.6 6.8 8.2 9.4 11.5 3.3 4.4 5.6 6.7 8.4 9.8 3.3 4.5 6.0 7.4 8.5 10.1 3.4 4.7 6.1 7.6 9.3 3.7 4.9 6.5 SHCkW 0.41 0.50 0.60 0.70 0.78 0.27 0.36 0.45 0.56 0.64 0.84 0.21 0.29 0.38 0.46 0.61 0.74 0.23 0.30 0.44 0.55 0.67 0.82 0.25 0.36 0.48 0.61 0.77 0.29 0.39 0.54 SHF 6.3 6.2 6.1 6.0 6.0 6.3 6.2 6.1 6.0 6.0 5.9 6.2 6.1 6.0 6.0 5.9 5.9 6.0 6.0 5.9 5.9 5.8 5.8 5.9 5.9 5.8 5.8 5.7 5.8 5.8 5.7 T/I kW 15.3 14.8 14.3 13.8 13.8 15.3 14.8 14.3 13.8 13.8 12.9 14.8 14.3 13.8 13.8 12.9 12.5 13.8 13.8 12.9 12.5 12.1 11.7 12.9 12.5 12.1 11.7 11.3 12.1 11.7 11.3 Q kW 46.0 6.5 7.7 9.2 10.6 11.9 4.4 5.6 6.8 8.3 9.5 11.3 3.4 4.4 5.8 6.9 8.4 10.0 3.3 4.6 6.0 7.4 8.6 10.3 3.5 4.7 6.1 7.7 9.3 3.6 4.9 6.4 SHCkW 0.43 0.52 0.64 0.76 0.86 0.28 0.38 0.47 0.60 0.69 0.88 0.23 0.31 0.42 0.50 0.65 0.80 0.24 0.33 0.46 0.59 0.71 0.88 0.27 0.38 0.50 0.65 0.82 0.30 0.42 0.57 SHF 6.7 6.7 6.6 6.5 6.4 6.7 6.7 6.6 6.5 6.4 6.4 6.7 6.6 6.5 6.4 6.4 6.3 6.5 6.4 6.4 6.3 6.3 6.2 6.4 6.3 6.3 6.2 6.1 6.3 6.2 6.1 T/I kW CAPACITY TABLES - 19 - 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.3 3.3 9.1 9.1 9.0 9.0 8.9 8.9 8.8 8.8 8.7 8.7 18 19 20 21 22 23 24 25 26 27 4.2 4.2 4.2 4.3 4.3 4.4 4.4 4.4 4.5 4.5 14.3 14.2 14.2 14.1 14.1 14.0 14.0 13.9 13.9 13.8 13.7 13.6 16 17 18 19 20 21 22 23 24 25 26 27 12.3 12.3 12.2 12.2 12.2 12.1 12.1 12.0 12.0 11.9 11.8 3.4 3.5 3.5 3.5 3.5 3.5 3.6 3.6 3.6 3.6 3.7 15.6 15.7 15.8 15.9 15.9 16.0 16.1 16.1 16.2 16.3 16.3 16.4 17.7 17.8 18.0 18.1 18.1 18.2 18.3 18.4 18.5 18.5 18.6 18.6 18.7 Q kW 5.8 5.8 5.7 5.6 5.6 5.6 5.5 5.5 5.4 5.4 5.2 5.1 5.2 T/I kW HEATING PEH-5MYA-EU 35 584 0.987 1.021 CMM L/S CAPACITY TOTAL INPUT AIR VOLUME 700 1.0 1.0 42 Factor for Various Air Flow 834 1.011 0.983 50 T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 125Pa”.) 5.2 5.1 5.1 5.0 5.0 4.9 4.9 4.9 4.8 4.8 4.7 4.7 4.7 T/I kW 4.1 4.1 4.1 4.0 3.9 3.9 3.9 3.8 3.8 3.8 3.8 3.7 3.7 T/I kW 0.0 15.0 12.3 3.4 10.0 16.4 * Q:HEATING CAPACITY 4.6 4.5 4.2 14.3 15 DB ˚C 12.4 3.4 OUTDOOR WB ˚C 10.2 10.2 10.3 10.3 10.4 10.4 10.5 10.5 10.6 10.6 10.7 10.7 10.7 Q kW T/I kW Q kW 3.1 9.1 17 5.0 3.1 9.2 16 INDOOR 3.1 9.2 Q kW T/I kW -5.0 OUTDOOR WB ˚C Q kW T/I kW Q kW -10.0 15 DB ˚C INDOOR PEH-5MYA-EU Heating Capacity (Standard Air Flow) - 20 - 5.6 5.7 5.8 0.89 0.72 0.60 0.48 13.3 11.5 9.6 7.3 18.4 19.3 19.9 21.2 22.0 17 18 19 20 21 18 19 6.3 6.5 6.1 6.3 6.4 6.5 6.8 6.3 6.4 6.5 6.6 6.9 6.4 6.5 0.49 0.25 0.80 0.66 0.50 0.41 0.22 0.89 0.70 0.59 0.48 0.28 0.84 0.74 9.4 5.3 14.9 12.8 10.3 8.7 5.1 17.2 14.2 12.4 10.5 6.7 17.2 15.6 19.3 20.4 21.2 18.7 19.3 20.4 21.2 22.1 23.0 19.3 20.4 21.2 22.1 23.0 24.0 20.4 21.2 5.9 6.1 6.2 5.8 5.9 6.1 6.2 6.3 6.4 5.9 6.1 6.2 6.3 6.4 6.6 6.1 6.2 0.34 0.25 0.79 0.66 0.50 0.41 0.30 0.22 0.87 0.68 0.58 0.47 0.37 0.28 0.84 0.73 5.5 15.2 13.0 10.6 8.9 6.9 5.3 17.3 14.5 12.7 10.7 8.9 6.9 17.7 16.0 19.3 19.9 21.2 22.0 22.8 23.7 19.9 21.2 22.0 22.8 23.7 24.7 21.2 22.0 20 21 22 23 19 20 21 22 23 24 20 21 COOLING CAPACITY TOTAL INPUT SHC AIR VOLUME 50 830 0.975 0.989 0.964 CMM L/S Factor for Various Air Flow PE-7MYC-EU PEH-7MYA-EU 0.43 1,000 1.0 1.0 1.0 60 SHC:SENSIBLE HEAT CAPACITY 10.3 6.9 0.41 8.5 20.5 7.0 0.48 10.3 21.3 70 1,167 1.024 1.009 1.040 ( 0.44 7.3 35.0 7.2 0.50 9.0 17.9 7.4 0.43 8.4 19.6 7.5 0.50 10.1 20.4 9.9 0.45 7.8 7.7 0.55 11.6 21.2 22.2 7.5 0.66 7.4 0.77 15.1 19.6 13.4 7.3 0.88 16.6 18.8 20.4 7.8 0.29 6.4 22.2 7.7 7.4 0.61 12.0 19.6 0.39 7.3 0.73 13.7 18.8 8.4 7.2 0.94 16.8 17.9 21.2 7.7 0.23 4.8 21.2 7.5 7.3 0.53 9.9 18.8 0.32 7.2 0.69 12.3 17.9 6.4 7.0 0.83 14.2 17.2 20.4 7.4 0.26 5.1 19.6 7.3 7.0 0.62 10.7 17.2 0.36 6.9 0.75 12.4 16.5 6.8 6.8 0.94 14.8 15.8 18.8 7.2 7.0 6.9 6.8 6.7 6.9 6.8 6.7 T/I kW 0.29 0.40 0.55 0.70 0.90 0.33 0.46 0.63 SHF 5.2 6.9 9.0 11.0 13.5 5.5 7.2 9.5 SHCkW 17.9 17.2 16.5 15.8 15.1 16.5 15.8 15.1 Q kW 40.0 7.7 0.51 8.7 17.0 8.0 0.43 8.1 18.7 20.0 ) 0.46 8.3 9.7 19.2 8.2 0.56 11.4 20.3 21.2 18.4 8.1 0.67 17.6 8.0 0.80 14.9 18.7 13.1 16.9 7.9 0.92 16.5 17.9 19.5 20.0 8.3 0.30 6.4 21.2 19.2 18.4 8.1 0.51 9.9 19.5 8.2 17.6 8.0 0.63 11.7 18.7 0.40 16.9 7.9 0.75 13.4 17.9 8.2 16.0 7.7 0.96 16.3 17.0 20.3 19.2 8.2 0.23 4.6 18.4 17.6 16.9 16.0 15.5 17.6 16.9 16.0 15.5 14.8 14.2 16.0 15.5 14.8 14.2 13.6 14.8 14.2 13.6 Q kW 20.3 8.1 7.9 0.54 9.6 17.9 0.32 7.7 0.71 12.0 17.0 6.2 7.6 0.85 14.1 16.5 19.5 8.0 0.26 4.9 18.7 7.9 7.6 0.64 10.5 16.5 0.37 7.5 0.77 12.1 15.7 6.6 7.3 0.97 14.5 15.0 17.9 7.7 7.6 7.5 7.3 7.2 7.5 7.3 7.2 T/I kW 0.29 0.41 0.56 0.71 0.93 0.34 0.46 0.64 SHF 5.0 6.8 8.8 10.7 13.2 5.3 6.9 9.1 SHCkW 17.0 16.5 15.7 15.0 14.3 15.7 15.0 14.3 Q kW In case of “indoor fan external static pressure: ESP = 125Pa”. If you need “ESP = 50Pa”, please subtract “0.1kw” from “T/I value of this table”. 10.1 7.2 0.54 11.9 22.1 23.1 7.0 0.64 6.9 0.75 15.4 20.5 13.7 6.8 0.86 17.0 19.7 21.3 7.3 0.29 6.6 23.1 7.2 6.9 0.60 12.2 20.5 0.38 6.8 0.71 14.0 19.7 8.5 6.7 0.91 17.1 18.7 22.1 7.2 0.23 5.0 22.1 7.0 6.8 0.51 10.1 19.7 0.31 6.7 0.67 12.6 18.7 6.6 6.6 0.82 14.7 18.0 21.3 6.9 0.25 5.2 20.5 6.8 6.7 0.50 9.3 18.7 0.35 6.6 0.62 11.1 18.0 7.0 6.4 0.74 12.7 17.2 19.7 6.3 0.93 15.3 16.5 6.6 6.4 6.3 6.2 6.4 6.3 6.2 T/I kW 6.7 0.40 0.54 0.68 0.88 0.33 0.45 0.62 SHF OUTDOOR DB˚C 0.29 7.2 9.3 11.3 13.9 5.7 7.4 9.8 SHCkW 30.0 5.3 18.7 18.0 17.2 16.5 15.8 17.2 16.5 15.8 Q kW T/I:TOTAL INPUT 6.9 24.0 6.6 0.42 10.5 24.7 24 6.8 0.53 12.2 23.0 6.4 0.52 12.3 23.7 23 6.6 6.3 0.62 14.1 22.8 22 0.63 6.8 6.6 13.9 0.38 0.31 22.1 8.7 6.8 6.4 6.1 0.61 11.3 18.7 0.35 6.0 0.73 13.0 17.9 7.1 5.9 6.3 6.1 6.0 5.9 5.8 6.0 5.9 5.8 T/I kW 0.90 0.28 0.39 0.53 0.67 0.86 0.33 0.44 0.61 SHF 15.5 5.4 7.3 9.5 11.5 14.2 5.8 7.7 10.1 SHCkW 25.0 17.2 19.3 5.9 15.8 0.28 18.7 5.8 17.7 5.6 17.9 17.2 16.5 5.7 16 5.6 19.9 0.39 0.53 0.67 5.5 17.9 5.7 19 7.5 9.7 11.8 0.85 17.2 5.6 19.3 17.7 16 14.4 0.32 16.5 Q kW 5.5 T/I kW 18 16.9 15 6.0 0.44 0.61 SHF 18.4 18.4 17 7.9 10.3 SHCkW 17 17.7 16.9 15 16 Q kW WB ˚C 20.0 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR PE-7MYC-EU , PEH-7MYA-EU Cooling Capacity (Standard Air Flow) 46.0 9.3 11.1 12.7 14.4 16.2 6.2 7.9 9.5 11.2 12.9 15.8 4.3 5.9 7.7 9.2 11.5 13.6 4.7 6.3 8.4 10.2 11.8 14.1 4.8 6.5 8.5 10.3 12.9 5.0 6.6 8.9 SHCkW SHF 0.47 0.58 0.69 0.82 0.96 0.31 0.41 0.52 0.63 0.76 0.99 0.23 0.32 0.44 0.55 0.72 0.88 0.26 0.37 0.52 0.66 0.79 0.99 0.30 0.42 0.57 0.73 0.95 0.34 0.47 0.65 9.0 8.9 8.7 8.6 8.5 9.0 8.9 8.7 8.6 8.5 8.3 8.9 8.7 8.6 8.5 8.3 8.2 8.6 8.5 8.3 8.2 8.1 8.0 8.3 8.2 8.1 8.0 7.9 8.1 8.0 7.9 T/I kW - 21 - 5.3 5.4 5.5 0.70 0.57 0.46 9.9 21.6 22.5 23.4 24.4 25.3 26.1 22.5 23.4 5.6 5.7 5.4 5.5 5.6 5.7 5.8 6.0 5.5 5.6 5.7 5.8 6.0 6.1 5.6 5.7 0.34 0.25 0.76 0.63 0.50 0.41 0.30 0.23 0.81 0.67 0.56 0.45 0.36 0.28 0.83 0.71 7.7 5.8 15.8 13.6 11.3 9.5 7.3 5.7 17.5 15.1 13.2 11.0 9.2 7.3 18.8 16.8 23.5 20.7 21.7 22.6 23.5 24.5 25.4 21.7 22.6 23.5 24.5 25.4 26.2 22.6 23.5 21 18 19 20 21 22 23 19 20 21 22 23 24 20 21 25.3 26.1 6.0 6.1 0.49 0.41 12.5 10.8 25.4 26.2 23 24 10.7 12.5 14.6 16.7 18.6 7.3 9.1 11.0 13.2 15.0 17.5 5.7 7.3 9.5 11.2 13.5 15.7 5.8 7.6 9.9 11.8 13.8 16.3 5.9 7.9 10.0 12.3 14.8 6.2 8.3 10.6 23.3 24.3 25.2 21.5 22.4 23.3 24.3 25.2 25.9 22.4 23.3 5.3 5.3 5.5 5.6 5.7 5.3 5.5 5.6 5.7 5.8 5.9 5.5 5.6 5.7 5.8 5.9 6.1 5.6 5.7 0.70 0.57 0.46 0.34 0.25 0.76 0.63 0.50 0.40 0.30 0.22 0.81 0.67 0.56 0.41 0.49 0.60 0.71 0.83 0.28 0.36 COOLING CAPACITY TOTAL INPUT SHC AIR VOLUME 50 830 0.975 0.989 0.964 CMM L/S Factor for Various Air Flow PE-7MYC-EU PEH-7MYA-EU 25.9 6.1 1,000 1.0 1.0 1.0 60 1,167 1.024 1.009 1.040 70 25.2 5.9 10.7 12.4 14.6 16.6 18.5 7.2 9.1 10.9 13.1 14.9 17.5 5.6 7.2 9.4 11.1 13.5 15.7 5.8 7.6 9.8 11.8 13.7 16.3 5.9 7.8 9.9 12.2 14.7 6.2 8.2 10.6 22.2 23.1 24.1 25.0 21.3 22.2 23.1 24.1 25.0 25.6 22.2 23.1 5.6 5.8 5.9 5.5 5.6 5.8 5.9 6.0 6.1 5.6 5.8 5.9 6.0 6.1 6.2 5.8 5.9 0.46 0.34 0.25 0.76 0.63 0.50 0.40 0.30 0.22 ( 21.3 5.5 0.57 0.41 0.49 0.60 0.71 0.83 0.28 0.36 0.45 0.56 0.67 0.81 20.3 5.4 0.70 24.1 25.0 25.6 6.0 6.1 6.2 23.1 22.2 21.3 20.3 19.4 18.4 5.8 0.87 21.3 20.3 19.4 18.4 17.5 19.4 18.4 17.5 10.6 12.4 14.4 16.4 18.3 7.1 9.0 10.9 13.0 14.8 17.4 5.5 7.1 9.2 10.9 13.3 15.5 5.7 7.5 9.7 11.7 13.6 16.1 5.8 7.7 9.9 12.1 14.6 6.1 8.1 10.5 Q kW SHCkW 5.6 5.5 5.4 5.3 5.1 5.4 5.3 5.1 T/I kW 0.27 0.38 0.51 0.66 0.83 0.31 0.44 0.60 SHF 10.0 21.7 22.6 19.9 20.8 21.7 22.6 23.5 24.3 20.8 21.7 22.6 23.5 24.3 25.2 21.7 22.6 5.5 5.6 5.8 5.9 6.0 5.6 5.8 5.9 6.0 6.1 6.3 5.8 5.9 6.0 6.1 6.3 6.5 5.9 6.0 0.70 0.58 0.46 0.34 0.25 0.76 0.63 0.49 0.41 0.50 0.60 0.71 0.82 0.28 0.36 0.45 0.56 0.67 0.82 0.22 0.30 0.40 20.8 5.4 0.87 23.5 24.3 25.2 6.1 6.3 6.5 19.9 19.1 18.2 20.8 5.8 0.27 19.9 19.1 18.2 17.3 19.1 18.2 17.3 10.5 12.4 14.3 16.2 18.0 7.0 8.9 10.8 12.8 14.6 17.4 5.4 7.0 9.1 10.8 13.2 15.4 5.6 7.4 9.7 11.6 13.4 16.0 5.7 7.6 9.8 12.0 14.5 6.0 8.0 10.4 Q kW SHCkW 5.6 5.5 5.4 5.3 5.5 5.4 5.3 T/I kW 0.38 0.51 0.66 0.84 0.31 0.44 0.60 SHF 26 27 6.1 6.2 6.3 0.46 0.34 0.25 ) 25 5.9 0.58 0.42 0.51 0.61 0.72 0.83 0.28 0.37 0.46 0.57 0.68 0.83 0.22 0.30 0.40 0.50 0.63 6.7 6.5 6.4 6.3 6.2 6.7 6.5 6.4 6.3 6.2 6.1 6.5 6.4 6.3 6.2 6.1 5.9 24 5.8 0.70 0.77 23 5.7 0.88 ( 17.6 17.8 18.0 18.0 18.0 18.1 18.2 18.2 18.2 18.4 18.4 18.8 18.5 6.5 6.5 6.4 6.4 6.3 6.2 6.2 6.1 6.1 6.0 6.0 5.9 5.9 5.3 5.3 5.3 5.3 5.2 5.2 5.2 5.1 5.1 5.1 5.0 5.0 5.0 20.5 20.6 20.8 20.8 20.9 21.0 21.0 21.0 21.0 21.2 21.3 21.7 21.4 7.2 7.2 7.1 7.0 7.0 6.9 6.8 6.7 6.7 6.6 6.6 6.5 6.4 T/I kW 10.0 OUTDOOR WB ˚C 12.7 12.8 13.0 12.9 13.0 13.1 13.1 13.2 13.2 13.3 13.4 13.8 13.5 Q kW T/I kW Q kW 5.0 4.9 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.7 4.7 4.6 4.6 23.6 23.7 23.9 23.9 24.0 24.1 24.1 24.2 24.2 24.4 24.4 24.8 24.6 Q kW HEATING 50 830 0.980 1.028 CMM L/S CAPACITY TOTAL INPUT AIR VOLUME 1,000 1.0 1.0 60 Factor for Various Air Flow PEH-7MYA-EU 8.0 7.9 7.9 7.8 7.7 7.6 7.6 7.5 7.4 7.3 7.2 7.1 7.0 T/I kW 5.9 5.8 5.8 5.8 5.7 5.7 5.6 5.6 5.5 5.5 5.5 5.4 5.4 T/I kW 0.0 15.0 15.0 15.1 15.4 15.3 15.4 15.5 15.5 15.6 15.6 15.7 15.8 16.1 15.4 Q kW 1,167 1.011 0.98 70 * Q:HEATING CAPACITY T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 125Pa”. If you need “ESP = 50Pa”, please subtract “0.1kw” from “T/I value of this table”. 27 26 25 24 23 22 21 20 19 18 17 16 15 DB ˚C INDOOR 10.6 10.6 10.8 10.8 10.8 10.9 22 6.1 11.0 11.0 11.0 11.2 11.3 11.7 11.5 T/I kW -5.0 OUTDOOR WB ˚C Q kW T/I kW Q kW -10.0 21 0.27 20 19 18 17 16 5.9 5.8 5.7 5.6 5.8 5.7 15 DB ˚C INDOOR PEH-7MYA-EU Heating Capacity (Standard Air Flow) 0.38 0.51 0.66 0.84 0.32 0.44 5.6 SHF T/I kW 0.60 15.0 T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 125Pa”. If you need “ESP = 50Pa”, please subtract “0.1kw” from “T/I value of this table”. 24.3 5.8 22.4 21.5 20.5 23.3 22.4 21.5 20.5 19.6 18.6 5.2 21.5 20.5 19.6 18.6 17.7 19.6 18.6 17.7 0.87 0.45 5.0 OUTDOOR DB˚C Q kW SHCkW 5.5 5.3 5.3 5.2 5.1 5.3 5.2 5.1 T/I kW 0.27 0.38 0.51 0.66 0.83 0.31 0.44 0.60 SHF SHC:SENSIBLE HEAT CAPACITY 24.4 5.8 0.60 14.7 24.5 22 25.3 24.4 23.4 22.5 21.6 20.6 23.4 22.5 21.6 22.6 20.6 19.7 20 11.9 13.8 18.7 21.6 20.6 19.7 18.7 17.8 19.7 18.7 17.8 21.7 19.8 17 5.2 0.87 16.4 0.0 Q kW SHC kW 19 18.8 16 5.5 5.4 5.3 5.2 5.0 5.3 5.2 5.0 0.28 6.0 0.38 0.51 0.66 0.83 0.31 0.44 0.59 T/I kW 20.7 21.7 19 7.9 10.0 12.4 14.8 6.2 8.3 10.6 SHF 18 20.7 18.8 16 18 17.9 15 19.8 19.8 17 17 18.8 16 17.9 Q kW SHCkW -5.0 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 15 DB˚C WB˚C INDOOR PE-7MYC-EU , PEH-7MYA-EU (Use for low ambient cooling parts) Cooling Capacity (Standard Air Flow) ) - 22 - 26.1 23.5 21 18 27.9 28.8 24 26.1 21 23 25.2 20 27.0 28.8 24 22 27.9 25.2 20 23 24.4 19 27.0 27.9 23 22 27.0 22 26.1 26.1 21 21 25.2 20 24.4 25.2 20 19 24.4 22.7 17 19 22.0 16 23.5 24.4 19 18 23.5 22.0 16 18 21.3 15 22.7 22.7 17 17 22.0 21.3 15 16 Q kW WB ˚C 11.9 13.8 16.1 18.5 21.0 7.9 10.0 11.9 14.4 16.6 19.2 6.0 8.0 10.4 12.3 14.7 17.4 6.1 8.1 10.7 12.9 15.1 18.1 6.2 8.7 11.1 13.8 16.2 6.6 9.0 11.6 SHCkW 20.0 28.0 7.2 26.2 27.1 28.0 7.0 7.2 25.3 6.9 6.8 24.4 27.1 7.0 6.7 26.2 25.3 24.4 6.9 6.8 6.7 23.6 27.1 7.0 6.5 26.2 25.3 24.4 23.6 22.8 25.3 24.4 23.6 22.8 22.0 21.3 23.6 22.8 22.0 21.3 20.6 22.0 21.3 20.6 Q kW 6.9 6.8 6.7 6.5 6.4 6.8 6.7 6.5 6.4 6.3 6.2 6.5 6.4 6.3 6.2 6.1 6.3 6.2 6.1 T/I kW COOLING PEH-8MYA-EU PE-8MYC-EU CAPACITY TOTAL INPUT SHC AIR VOLUME 11.8 13.5 15.8 18.2 20.7 7.7 9.8 11.6 14.1 16.2 18.7 5.9 7.9 10.2 12.1 14.3 17.0 5.9 7.8 10.4 12.6 14.8 17.7 6.0 8.5 10.9 13.6 15.9 6.4 8.8 11.4 SHCkW 25.0 0.42 0.50 0.60 0.72 0.85 0.27 0.36 0.44 0.56 0.66 0.79 0.22 0.30 0.40 0.50 0.61 0.75 0.23 0.32 0.44 0.55 0.67 0.83 0.26 0.37 0.50 0.64 0.77 0.29 0.41 0.55 SHF 60 1,000 0.976 0.991 0.963 CMM L/S 1,167 1.0 1.0 1.0 70 SHC:SENSIBLE HEAT CAPACITY 0.41 0.49 0.60 0.71 0.83 0.27 0.36 0.44 0.55 0.66 0.79 0.22 0.30 0.40 0.49 0.60 0.74 0.23 0.32 0.44 0.55 0.67 0.82 0.26 0.37 0.49 0.63 0.76 0.29 0.41 0.55 SHF Factor for Various Air Flow Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR 27.1 26.3 25.4 24.5 23.7 27.1 26.3 25.4 24.5 23.7 22.9 26.3 25.4 24.5 23.7 22.9 22.1 24.5 23.7 22.9 22.1 21.3 20.6 22.9 22.1 21.3 20.6 19.9 21.3 20.6 19.9 Q kW 11.9 13.5 15.6 17.9 20.4 7.5 9.6 11.4 13.9 15.9 18.4 5.7 7.7 10.0 12.0 14.1 16.7 5.7 7.6 10.2 12.3 14.5 17.4 5.9 8.4 10.7 13.3 15.7 6.2 8.5 11.1 SHCkW 0.44 0.51 0.62 0.73 0.86 0.28 0.36 0.45 0.57 0.67 0.80 0.22 0.30 0.41 0.50 0.62 0.76 0.23 0.32 0.44 0.56 0.68 0.84 0.26 0.38 0.50 0.65 0.79 0.29 0.41 0.56 SHF 7.9 7.8 7.6 7.5 7.4 7.9 7.8 7.6 7.5 7.4 7.3 7.8 7.6 7.5 7.4 7.3 7.2 7.5 7.4 7.3 7.2 7.0 6.9 7.3 7.2 7.0 6.9 6.8 7.0 6.9 6.8 T/I kW 26.0 25.3 24.4 23.7 22.8 26.0 25.3 24.4 23.7 22.8 22.0 25.3 24.4 23.7 22.8 22.0 21.3 23.7 22.8 22.0 21.3 20.6 19.9 22.0 21.3 20.6 19.9 19.2 20.6 19.9 19.2 Q kW OUTDOOR DB˚C 35.0 11.7 13.3 15.4 17.7 19.9 7.2 9.3 11.1 13.5 15.5 17.8 5.5 7.4 9.7 11.7 13.8 16.4 5.6 7.4 9.9 12.0 14.3 17.1 5.7 8.1 10.4 13.1 15.5 5.9 8.2 10.9 SHCkW 0.45 0.53 0.63 0.75 0.87 0.28 0.37 0.46 0.57 0.68 0.81 0.22 0.30 0.41 0.51 0.63 0.77 0.24 0.32 0.45 0.56 0.69 0.86 0.26 0.38 0.50 0.66 0.81 0.29 0.41 0.57 SHF 8.4 8.3 8.1 8.0 7.9 8.4 8.3 8.1 8.0 7.9 7.8 8.3 8.1 8.0 7.9 7.8 7.6 8.0 7.9 7.8 7.6 7.5 7.4 7.8 7.6 7.5 7.4 7.3 7.5 7.4 7.3 T/I kW 25.2 24.3 23.6 22.8 22.0 25.2 24.3 23.6 22.8 22.0 21.3 24.3 23.6 22.8 22.0 21.3 20.6 22.8 22.0 21.3 20.6 19.8 19.1 21.3 20.6 19.8 19.1 18.3 19.8 19.1 18.3 Q kW 1,330 1.025 1.009 1.044 80 T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.) 7.5 7.4 7.2 7.1 7.0 7.5 7.4 7.2 7.1 7.0 6.9 7.4 7.2 7.1 7.0 6.9 6.7 7.1 7.0 6.9 6.7 6.6 6.5 6.9 6.7 6.6 6.5 6.4 6.6 6.5 6.4 T/I kW 30.0 PE-8MYC-EU , PEH-8MYA-EU (combined with PUH-8MYC2-EU) Cooling Capacity (Standard Air Flow) 40.0 11.7 13.1 15.2 17.3 19.6 7.0 9.1 11.1 13.5 15.5 17.9 5.3 7.3 9.5 11.5 13.6 16.2 5.4 7.2 9.7 11.9 14.0 16.8 5.6 8.0 10.2 12.7 14.9 5.9 8.1 10.5 SHCkW 0.46 0.54 0.64 0.76 0.89 0.28 0.37 0.47 0.59 0.70 0.84 0.22 0.31 0.42 0.52 0.64 0.78 0.24 0.33 0.46 0.58 0.71 0.88 0.26 0.39 0.52 0.67 0.82 0.30 0.42 0.58 SHF 8.9 8.8 8.7 8.6 8.5 8.9 8.8 8.7 8.6 8.5 8.3 8.8 8.7 8.6 8.5 8.3 8.2 8.6 8.5 8.3 8.2 8.1 7.9 8.3 8.2 8.1 7.9 7.8 8.1 7.9 7.8 T/I kW 46.0 SHF 8.7 8.5 8.6 8.7 8.8 8.9 8.6 8.7 8.8 8.9 9.1 9.2 8.8 0.82 0.68 0.53 0.40 0.27 0.90 0.72 0.59 0.46 0.33 0.24 0.80 14.5 12.4 9.9 7.7 5.4 16.4 13.7 11.5 9.4 7.0 5.2 15.6 17.6 18.3 18.9 19.5 20.2 18.3 18.9 19.5 20.2 20.9 21.7 19.5 9.2 0.78 16.9 21.7 9.6 9.1 0.90 18.8 20.9 9.5 9.6 0.28 6.7 23.9 0.48 9.5 0.38 8.8 23.1 11.5 9.3 0.48 10.8 22.4 23.9 9.2 0.61 13.3 21.7 9.3 9.1 0.73 15.2 20.9 0.56 8.9 0.87 17.6 20.2 12.8 9.5 0.22 5.1 23.1 23.1 9.3 0.31 7.0 22.4 0.66 9.2 0.43 9.3 21.7 14.8 9.1 0.53 11.1 20.9 22.4 8.9 0.65 13.2 20.2 7.9 8.6 18.3 0.30 8.5 T/I kW 5.7 0.58 18.9 10.3 SHCkW 0.43 17.6 Q kW - 23 - 5.9 6.0 5.8 5.9 6.0 6.1 6.2 5.9 0.41 0.29 0.77 0.62 0.48 0.36 0.26 0.82 9.4 6.9 17.0 14.1 11.4 8.9 6.6 18.8 22.9 23.8 22.0 22.9 23.8 24.7 25.6 22.9 16 17 15 16 17 18 19 16 17 6.1 6.2 6.3 6.4 6.1 0.55 0.44 0.33 0.24 0.73 13.5 11.2 8.6 6.5 18.1 24.7 25.6 26.5 27.4 24.7 19 20 21 18 30.8 29.0 28.2 27.3 26.4 30.8 29.0 28.2 27.3 26.4 25.5 29.0 28.2 27.3 26.4 25.5 24.6 27.3 26.4 25.5 24.6 23.8 22.9 25.5 24.6 23.8 22.9 22.0 23.8 22.9 22.0 12.2 14.2 16.7 19.2 21.5 8.2 10.3 12.4 15.0 17.2 20.0 6.3 8.2 10.7 12.7 15.4 18.0 6.4 8.6 11.2 13.4 15.7 18.7 6.6 8.9 11.3 14.1 16.9 6.9 9.3 12.0 Q kW SHC kW 0.0 COOLING CAPACITY TOTAL INPUT SHC AIR VOLUME 60 1,000 0.976 0.991 0.963 CMM L/S Factor for Various Air Flow PE-8MYC-EU PEH-8MYA-EU 6.5 6.6 6.7 6.9 6.4 6.5 6.6 6.7 6.9 0.44 0.36 0.27 0.81 0.70 0.59 0.49 0.40 6.0 0.73 0.55 6.5 0.24 6.4 6.4 0.32 0.65 6.3 0.44 6.3 6.0 0.55 0.78 6.0 0.66 6.7 5.9 0.82 0.22 6.3 0.26 6.6 6.0 0.36 0.29 6.0 0.48 6.5 5.9 0.61 0.39 5.8 0.77 6.4 6.0 0.29 0.48 5.9 0.41 6.3 5.8 0.55 0.60 T/I kW SHF 1,167 1.0 1.0 1.0 70 SHC:SENSIBLE HEAT CAPACITY 6.8 0.39 12.2 31.0 24 19.3 27.4 21 6.7 6.3 0.81 21.6 26.5 20 0.49 6.8 0.26 8.2 31.0 24 14.2 6.7 0.35 10.4 29.2 23 29.2 6.5 0.44 12.5 28.3 22 23 6.4 0.55 15.1 27.4 21 6.5 6.3 0.65 17.3 26.5 20 6.4 6.2 0.79 20.1 25.6 19 0.59 6.7 0.22 6.3 29.2 23 0.70 6.5 0.29 8.2 28.3 22 16.8 6.4 0.39 10.8 27.4 21 28.3 6.3 0.48 12.8 26.5 20 22 6.2 0.61 15.5 25.6 19 6.0 0.66 15.8 23.8 18 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 5.8 15 0.55 T/I kW SHF 12.1 Q kW SHCkW -5.0 22.0 DB˚C WB˚C INDOOR 12.2 14.1 16.7 19.1 21.4 8.1 10.3 12.4 14.9 17.1 19.9 6.3 8.1 10.7 12.7 15.3 17.9 6.4 8.5 11.1 13.4 15.6 18.6 6.5 8.9 11.3 14.0 16.8 6.8 9.3 12.0 6.6 6.7 6.8 7.0 6.5 6.6 6.7 6.8 7.0 0.44 0.35 0.27 0.81 0.70 0.59 0.49 0.40 6.2 0.73 0.55 6.6 0.23 6.5 6.5 0.32 0.65 6.3 0.44 6.3 6.2 0.54 0.78 6.1 0.66 6.8 6.0 0.82 0.22 6.3 0.26 6.7 6.2 0.36 0.29 6.1 0.48 6.6 6.0 0.62 0.39 5.9 0.77 6.5 6.1 0.29 0.48 6.0 0.41 6.3 5.9 0.55 0.60 T/I kW SHF 0.22 0.78 0.65 0.55 0.44 0.35 0.27 0.81 0.70 0.59 0.49 0.40 6.2 19.6 16.9 14.8 12.2 10.2 8.0 21.3 18.9 16.5 14.0 12.1 28.7 25.2 26.1 27.0 27.8 28.7 30.1 26.1 27.0 27.8 28.7 30.1 0.73 17.7 24.4 0.29 0.23 6.3 27.0 8.1 0.32 8.3 26.1 27.8 0.43 10.9 25.2 0.39 0.54 13.2 24.4 10.6 0.66 15.5 23.5 27.0 0.81 18.5 22.7 0.48 0.25 6.4 25.2 12.6 0.36 8.8 24.4 26.1 0.48 11.2 23.5 0.60 0.61 13.9 22.7 15.1 0.76 25.2 0.29 6.8 16.6 21.8 0.40 9.2 22.7 23.5 0.54 11.9 SHF 21.8 Q kW SHCkW 10.0 0.29 0.21 0.78 0.65 0.55 0.44 0.35 0.27 0.82 0.70 0.59 0.49 0.41 8.0 6.1 19.4 16.7 14.6 12.1 10.1 7.9 21.1 18.7 16.3 13.9 12.0 28.6 25.0 25.8 26.7 27.7 28.6 29.5 25.8 26.7 27.7 28.6 29.5 7.0 6.6 6.7 6.8 6.9 7.0 7.2 6.7 6.8 6.9 7.0 7.2 0.73 17.6 24.1 6.4 27.7 0.23 6.2 26.7 6.8 6.9 0.32 8.2 25.8 6.7 0.39 0.43 10.8 25.0 6.6 10.5 0.54 13.0 24.1 6.4 26.7 0.66 15.3 23.3 6.3 6.8 0.81 18.3 22.4 6.2 0.48 0.25 6.3 25.0 6.6 12.5 0.36 8.7 24.1 6.4 25.8 0.48 11.1 23.3 6.3 6.7 0.62 13.8 22.4 6.2 0.60 0.76 21.6 6.0 14.9 0.29 6.7 16.4 23.3 6.3 25.0 0.40 9.1 22.4 6.2 6.6 0.54 11.7 SHF 21.6 Q kW SHCkW 6.0 T/I kW 15.0 14.2 14.1 17 18 19 20 21 22 23 24 25 26 27 6.5 6.3 6.4 6.5 6.6 7.0 6.4 6.5 6.6 7.0 7.0 7.5 7.3 7.2 7.1 7.0 7.5 7.3 7.2 7.1 7.0 7.0 7.3 7.2 7.1 7.0 7.0 6.6 80 1,330 1.025 1.009 1.044 6.7 6.7 6.6 6.6 6.5 6.4 6.4 6.3 6.3 6.2 6.2 6.1 6.1 23.7 23.8 24 24 24.1 24.2 24.2 24.3 24.3 24.4 24.5 24.6 24.6 7.4 7.4 7.3 7.2 7.2 7.1 7.0 6.9 6.9 6.8 6.8 7.0 6.6 T/I kW 10.0 ) 26.8 26.9 27.1 27.1 27.2 27.3 27.3 27.4 27.4 27.6 27.6 27.7 27.8 Q kW HEATING PEH-8MYA-EU 60 1,000 0.989 1.010 CMM L/S CAPACITY TOTAL INPUT AIR VOLUME 70 1,167 1.0 1.0 5.6 6.1 6.0 6.0 6.0 5.9 5.9 5.8 5.8 5.7 5.7 5.7 5.6 1,330 1.011 0.987 80 8.2 8.1 8.1 8.0 7.9 7.8 7.8 7.7 7.6 7.5 7.4 7.3 7.2 T/I kW 15.0 18.2 18.3 18.6 18.5 18.6 18.7 18.7 18.8 18.8 18.9 19 19 T/I kW 0.0 19.1 Factor for Various Air Flow ( 20.8 21 21.2 21.2 21.2 21.3 21.4 21.4 21.4 21.6 21.6 21.7 21.7 5.5 5.5 5.5 5.5 5.4 5.4 5.4 5.3 5.3 5.3 5.2 5.2 5.2 OUTDOOR WB ˚C 15.9 16 16.2 16.1 16.2 16.3 16.3 16.4 16.4 16.5 16.6 16.7 16.7 Q kW T/I kW Q kW 5.1 13.8 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 4.9 4.9 13.8 14 14 14 14.2 14.2 14.4 4.8 4.8 Q kW * Q:HEATING CAPACITY T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 62/125Pa”. 27 26 25 24 23 22 21 20 19 18 17 16 15 DB ˚C INDOOR 14.5 16 6.4 7.1 14.6 15 6.3 14.7 DB ˚C T/I kW -5.0 OUTDOOR WB ˚C Q kW T/I kW Q kW -10.0 T/I kW INDOOR PEH-8MYA-EU (combined with PUH-8MYC2-EU) Heating Capacity (Standard Air Flow) T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.) 30.5 28.9 28.1 27.2 26.3 30.5 28.9 28.1 27.2 26.3 25.4 28.9 28.1 27.2 26.3 25.4 24.5 27.2 26.3 25.4 24.5 23.7 22.8 25.4 24.5 23.7 22.8 21.9 23.7 22.8 21.9 Q kW SHCkW 5.0 OUTDOOR DB˚C PE-8MYC-EU , PEH-8MYA-EU (combined with PUH-8MYC2-EU) (Use for low ambient cooling parts) Cooling Capacity (Standard Air Flow) - 24 - 26.1 23.5 21 18 27.9 28.8 24 26.1 21 23 25.2 20 27.0 28.8 24 22 27.9 25.2 20 23 24.4 19 27.0 27.9 23 22 27.0 22 26.1 26.1 21 21 25.2 20 24.4 25.2 20 19 24.4 22.7 17 19 22.0 16 23.5 24.4 19 18 23.5 22.0 16 18 21.3 15 22.7 22.7 17 17 22.0 21.3 15 16 Q kW WB ˚C 11.9 13.8 16.1 18.5 21.0 7.9 10.0 11.9 14.4 16.6 19.2 6.0 8.0 10.4 12.3 14.7 17.4 6.1 8.1 10.7 12.9 15.1 18.1 6.2 8.7 11.1 13.8 16.2 6.6 9.0 11.6 SHCkW 20.0 28.0 7.2 26.2 27.1 28.0 7.0 7.2 25.3 6.9 6.8 24.4 27.1 7.0 6.7 26.2 25.3 24.4 6.9 6.8 6.7 23.6 27.1 7.0 6.5 26.2 25.3 24.4 23.6 22.8 25.3 24.4 23.6 22.8 22.0 21.3 23.6 22.8 22.0 21.3 20.6 22.0 21.3 20.6 Q kW 6.9 6.8 6.7 6.5 6.4 6.8 6.7 6.5 6.4 6.3 6.2 6.5 6.4 6.3 6.2 6.1 6.3 6.2 6.1 T/I kW COOLING PEH-8MYA-EU PE-8MYC-EU CAPACITY TOTAL INPUT SHC AIR VOLUME 11.8 13.5 15.8 18.2 20.7 7.7 9.8 11.6 14.1 16.2 18.7 5.9 7.9 10.2 12.1 14.3 17.0 5.9 7.8 10.4 12.6 14.8 17.7 6.0 8.5 10.9 13.6 15.9 6.4 8.8 11.4 SHCkW 25.0 0.42 0.50 0.60 0.72 0.85 0.27 0.36 0.44 0.56 0.66 0.79 0.22 0.30 0.40 0.50 0.61 0.75 0.23 0.32 0.44 0.55 0.67 0.83 0.26 0.37 0.50 0.64 0.77 0.29 0.41 0.55 SHF 60 1,000 0.976 0.991 0.963 CMM L/S 1,167 1.0 1.0 1.0 70 SHC:SENSIBLE HEAT CAPACITY 0.41 0.49 0.60 0.71 0.83 0.27 0.36 0.44 0.55 0.66 0.79 0.22 0.30 0.40 0.49 0.60 0.74 0.23 0.32 0.44 0.55 0.67 0.82 0.26 0.37 0.49 0.63 0.76 0.29 0.41 0.55 SHF Factor for Various Air Flow Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR 27.1 26.3 25.4 24.5 23.7 27.1 26.3 25.4 24.5 23.7 22.9 26.3 25.4 24.5 23.7 22.9 22.1 24.5 23.7 22.9 22.1 21.3 20.6 22.9 22.1 21.3 20.6 19.9 21.3 20.6 19.9 Q kW 11.9 13.5 15.6 17.9 20.4 7.5 9.6 11.4 13.9 15.9 18.4 5.7 7.7 10.0 12.0 14.1 16.7 5.7 7.6 10.2 12.3 14.5 17.4 5.9 8.4 10.7 13.3 15.7 6.2 8.5 11.1 SHCkW 0.44 0.51 0.62 0.73 0.86 0.28 0.36 0.45 0.57 0.67 0.80 0.22 0.30 0.41 0.50 0.62 0.76 0.23 0.32 0.44 0.56 0.68 0.84 0.26 0.38 0.50 0.65 0.79 0.29 0.41 0.56 SHF 7.9 7.8 7.6 7.5 7.4 7.9 7.8 7.6 7.5 7.4 7.3 7.8 7.6 7.5 7.4 7.3 7.2 7.5 7.4 7.3 7.2 7.0 6.9 7.3 7.2 7.0 6.9 6.8 7.0 6.9 6.8 T/I kW 26.0 25.3 24.4 23.7 22.8 26.0 25.3 24.4 23.7 22.8 22.0 25.3 24.4 23.7 22.8 22.0 21.3 23.7 22.8 22.0 21.3 20.6 19.9 22.0 21.3 20.6 19.9 19.2 20.6 19.9 19.2 Q kW OUTDOOR DB˚C 35.0 11.7 13.3 15.4 17.7 19.9 7.2 9.3 11.1 13.5 15.5 17.8 5.5 7.4 9.7 11.7 13.8 16.4 5.6 7.4 9.9 12.0 14.3 17.1 5.7 8.1 10.4 13.1 15.5 5.9 8.2 10.9 SHCkW 0.45 0.53 0.63 0.75 0.87 0.28 0.37 0.46 0.57 0.68 0.81 0.22 0.30 0.41 0.51 0.63 0.77 0.24 0.32 0.45 0.56 0.69 0.86 0.26 0.38 0.50 0.66 0.81 0.29 0.41 0.57 SHF 8.4 8.3 8.1 8.0 7.9 8.4 8.3 8.1 8.0 7.9 7.8 8.3 8.1 8.0 7.9 7.8 7.6 8.0 7.9 7.8 7.6 7.5 7.4 7.8 7.6 7.5 7.4 7.3 7.5 7.4 7.3 T/I kW 25.2 24.3 23.6 22.8 22.0 25.2 24.3 23.6 22.8 22.0 21.3 24.3 23.6 22.8 22.0 21.3 20.6 22.8 22.0 21.3 20.6 19.8 19.1 21.3 20.6 19.8 19.1 18.3 19.8 19.1 18.3 Q kW 1,330 1.025 1.009 1.044 80 T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.) 7.5 7.4 7.2 7.1 7.0 7.5 7.4 7.2 7.1 7.0 6.9 7.4 7.2 7.1 7.0 6.9 6.7 7.1 7.0 6.9 6.7 6.6 6.5 6.9 6.7 6.6 6.5 6.4 6.6 6.5 6.4 T/I kW 30.0 PE-8MYC-EU , PEH-8MYA-EU (combined with PUH-8MYE1-EU) Cooling Capacity (Standard Air Flow) 40.0 11.7 13.1 15.2 17.3 19.6 7.0 9.1 11.1 13.5 15.5 17.9 5.3 7.3 9.5 11.5 13.6 16.2 5.4 7.2 9.7 11.9 14.0 16.8 5.6 8.0 10.2 12.7 14.9 5.9 8.1 10.5 SHCkW 0.46 0.54 0.64 0.76 0.89 0.28 0.37 0.47 0.59 0.70 0.84 0.22 0.31 0.42 0.52 0.64 0.78 0.24 0.33 0.46 0.58 0.71 0.88 0.26 0.39 0.52 0.67 0.82 0.30 0.42 0.58 SHF 8.9 8.8 8.7 8.6 8.5 8.9 8.8 8.7 8.6 8.5 8.3 8.8 8.7 8.6 8.5 8.3 8.2 8.6 8.5 8.3 8.2 8.1 7.9 8.3 8.2 8.1 7.9 7.8 8.1 7.9 7.8 T/I kW 46.0 SHF 8.7 8.5 8.6 8.7 8.8 8.9 8.6 8.7 8.8 8.9 9.1 9.2 8.8 0.82 0.68 0.53 0.40 0.27 0.90 0.72 0.59 0.46 0.33 0.24 0.80 14.5 12.4 9.9 7.7 5.4 16.4 13.7 11.5 9.4 7.0 5.2 15.6 17.6 18.3 18.9 19.5 20.2 18.3 18.9 19.5 20.2 20.9 21.7 19.5 9.2 0.78 16.9 21.7 9.6 9.1 0.90 18.8 20.9 9.5 9.6 0.28 6.7 23.9 0.48 9.5 0.38 8.8 23.1 11.5 9.3 0.48 10.8 22.4 23.9 9.2 0.61 13.3 21.7 9.3 9.1 0.73 15.2 20.9 0.56 8.9 0.87 17.6 20.2 12.8 9.5 0.22 5.1 23.1 23.1 9.3 0.31 7.0 22.4 0.66 9.2 0.43 9.3 21.7 14.8 9.1 0.53 11.1 20.9 22.4 8.9 0.65 13.2 20.2 7.9 8.6 18.3 0.30 8.5 T/I kW 5.7 0.58 18.9 10.3 SHCkW 0.43 17.6 Q kW - 25 - 5.9 6.0 5.8 5.9 6.0 6.1 6.2 5.9 0.41 0.29 0.77 0.62 0.48 0.36 0.26 0.82 9.4 6.9 17.0 14.1 11.4 8.9 6.6 18.8 22.9 23.8 22.0 22.9 23.8 24.7 25.6 22.9 16 17 15 16 17 18 19 16 17 6.1 6.2 6.3 6.4 6.1 0.55 0.44 0.33 0.24 0.73 13.5 11.2 8.6 6.5 18.1 24.7 25.6 26.5 27.4 24.7 19 20 21 18 30.8 29.0 28.2 27.3 26.4 30.8 29.0 28.2 27.3 26.4 25.5 29.0 28.2 27.3 26.4 25.5 24.6 27.3 26.4 25.5 24.6 23.8 22.9 25.5 24.6 23.8 22.9 22.0 23.8 22.9 22.0 12.2 14.2 16.7 19.2 21.5 8.2 10.3 12.4 15.0 17.2 20.0 6.3 8.2 10.7 12.7 15.4 18.0 6.4 8.6 11.2 13.4 15.7 18.7 6.6 8.9 11.3 14.1 16.9 6.9 9.3 12.0 Q kW SHC kW 0.0 COOLING CAPACITY TOTAL INPUT SHC AIR VOLUME 60 1,000 0.976 0.991 0.963 CMM L/S Factor for Various Air Flow PE-8MYC-EU PEH-8MYA-EU 6.5 6.6 6.7 6.9 6.4 6.5 6.6 6.7 6.9 0.44 0.36 0.27 0.81 0.70 0.59 0.49 0.40 6.0 0.73 0.55 6.5 0.24 6.4 6.4 0.32 0.65 6.3 0.44 6.3 6.0 0.55 0.78 6.0 0.66 6.7 5.9 0.82 0.22 6.3 0.26 6.6 6.0 0.36 0.29 6.0 0.48 6.5 5.9 0.61 0.39 5.8 0.77 6.4 6.0 0.29 0.48 5.9 0.41 6.3 5.8 0.55 0.60 T/I kW SHF 1,167 1.0 1.0 1.0 70 SHC:SENSIBLE HEAT CAPACITY 6.8 0.39 12.2 31.0 24 19.3 27.4 21 6.7 6.3 0.81 21.6 26.5 20 0.49 6.8 0.26 8.2 31.0 24 14.2 6.7 0.35 10.4 29.2 23 29.2 6.5 0.44 12.5 28.3 22 23 6.4 0.55 15.1 27.4 21 6.5 6.3 0.65 17.3 26.5 20 6.4 6.2 0.79 20.1 25.6 19 0.59 6.7 0.22 6.3 29.2 23 0.70 6.5 0.29 8.2 28.3 22 16.8 6.4 0.39 10.8 27.4 21 28.3 6.3 0.48 12.8 26.5 20 22 6.2 0.61 15.5 25.6 19 6.0 0.66 15.8 23.8 18 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 5.8 15 0.55 T/I kW SHF 12.1 Q kW SHCkW -5.0 22.0 DB˚C WB˚C INDOOR 12.2 14.1 16.7 19.1 21.4 8.1 10.3 12.4 14.9 17.1 19.9 6.3 8.1 10.7 12.7 15.3 17.9 6.4 8.5 11.1 13.4 15.6 18.6 6.5 8.9 11.3 14.0 16.8 6.8 9.3 12.0 6.6 6.7 6.8 7.0 6.5 6.6 6.7 6.8 7.0 0.44 0.35 0.27 0.81 0.70 0.59 0.49 0.40 6.2 0.73 0.55 6.6 0.23 6.5 6.5 0.32 0.65 6.3 0.44 6.3 6.2 0.54 0.78 6.1 0.66 6.8 6.0 0.82 0.22 6.3 0.26 6.7 6.2 0.36 0.29 6.1 0.48 6.6 6.0 0.62 0.39 5.9 0.77 6.5 6.1 0.29 0.48 6.0 0.41 6.3 5.9 0.55 0.60 T/I kW SHF 0.22 0.78 0.65 0.55 0.44 0.35 0.27 0.81 0.70 0.59 0.49 0.40 6.2 19.6 16.9 14.8 12.2 10.2 8.0 21.3 18.9 16.5 14.0 12.1 28.7 25.2 26.1 27.0 27.8 28.7 30.1 26.1 27.0 27.8 28.7 30.1 0.73 17.7 24.4 0.29 0.23 6.3 27.0 8.1 0.32 8.3 26.1 27.8 0.43 10.9 25.2 0.39 0.54 13.2 24.4 10.6 0.66 15.5 23.5 27.0 0.81 18.5 22.7 0.48 0.25 6.4 25.2 12.6 0.36 8.8 24.4 26.1 0.48 11.2 23.5 0.60 0.61 13.9 22.7 15.1 0.76 25.2 0.29 6.8 16.6 21.8 0.40 9.2 22.7 23.5 0.54 11.9 SHF 21.8 Q kW SHCkW 10.0 0.29 0.21 0.78 0.65 0.55 0.44 0.35 0.27 0.82 0.70 0.59 0.49 0.41 8.0 6.1 19.4 16.7 14.6 12.1 10.1 7.9 21.1 18.7 16.3 13.9 12.0 28.6 25.0 25.8 26.7 27.7 28.6 29.5 25.8 26.7 27.7 28.6 29.5 7.0 6.6 6.7 6.8 6.9 7.0 7.2 6.7 6.8 6.9 7.0 7.2 0.73 17.6 24.1 6.4 27.7 0.23 6.2 26.7 6.8 6.9 0.32 8.2 25.8 6.7 0.39 0.43 10.8 25.0 6.6 10.5 0.54 13.0 24.1 6.4 26.7 0.66 15.3 23.3 6.3 6.8 0.81 18.3 22.4 6.2 0.48 0.25 6.3 25.0 6.6 12.5 0.36 8.7 24.1 6.4 25.8 0.48 11.1 23.3 6.3 6.7 0.62 13.8 22.4 6.2 0.60 0.76 21.6 6.0 14.9 0.29 6.7 16.4 23.3 6.3 25.0 0.40 9.1 22.4 6.2 6.6 0.54 11.7 SHF 21.6 Q kW SHCkW 6.0 T/I kW 15.0 14.2 14.1 17 18 19 20 21 22 23 24 25 26 27 6.5 6.3 6.4 6.5 6.6 7.0 6.4 6.5 6.6 7.0 7.0 7.5 7.3 7.2 7.1 7.0 7.5 7.3 7.2 7.1 7.0 7.0 7.3 7.2 7.1 7.0 7.0 6.6 80 1,330 1.025 1.009 1.044 6.7 6.7 6.6 6.6 6.5 6.4 6.4 6.3 6.3 6.2 6.2 6.1 6.1 23.7 23.8 24 24 24.1 24.2 24.2 24.3 24.3 24.4 24.5 24.6 24.6 7.4 7.4 7.3 7.2 7.2 7.1 7.0 6.9 6.9 6.8 6.8 7.0 6.6 T/I kW 10.0 ) 26.8 26.9 27.1 27.1 27.2 27.3 27.3 27.4 27.4 27.6 27.6 27.7 27.8 Q kW HEATING PEH-8MYA-EU 60 1,000 0.989 1.010 CMM L/S CAPACITY TOTAL INPUT AIR VOLUME 70 1,167 1.0 1.0 5.6 6.1 6.0 6.0 6.0 5.9 5.9 5.8 5.8 5.7 5.7 5.7 5.6 1,330 1.011 0.987 80 8.2 8.1 8.1 8.0 7.9 7.8 7.8 7.7 7.6 7.5 7.4 7.3 7.2 T/I kW 15.0 18.2 18.3 18.6 18.5 18.6 18.7 18.7 18.8 18.8 18.9 19 19 T/I kW 0.0 19.1 Factor for Various Air Flow ( 20.8 21 21.2 21.2 21.2 21.3 21.4 21.4 21.4 21.6 21.6 21.7 21.7 5.5 5.5 5.5 5.5 5.4 5.4 5.4 5.3 5.3 5.3 5.2 5.2 5.2 OUTDOOR WB ˚C 15.9 16 16.2 16.1 16.2 16.3 16.3 16.4 16.4 16.5 16.6 16.7 16.7 Q kW T/I kW Q kW 5.1 13.8 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 4.9 4.9 13.8 14 14 14 14.2 14.2 14.4 4.8 4.8 Q kW * Q:HEATING CAPACITY T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 62/125Pa”. 27 26 25 24 23 22 21 20 19 18 17 16 15 DB ˚C INDOOR 14.5 16 6.4 7.1 14.6 15 6.3 14.7 DB ˚C T/I kW -5.0 OUTDOOR WB ˚C Q kW T/I kW Q kW -10.0 T/I kW INDOOR PEH-8MYA-EU (combined with PUH-8MYE1-EU) Heating Capacity (Standard Air Flow) T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.) 30.5 28.9 28.1 27.2 26.3 30.5 28.9 28.1 27.2 26.3 25.4 28.9 28.1 27.2 26.3 25.4 24.5 27.2 26.3 25.4 24.5 23.7 22.8 25.4 24.5 23.7 22.8 21.9 23.7 22.8 21.9 Q kW SHCkW 5.0 OUTDOOR DB˚C PE-8MYC-EU , PEH-8MYA-EU (combined with PUH-8ME1-EU) (Use for low ambient cooling parts) Cooling Capacity (Standard Air Flow) - 26 9.1 0.70 23.6 33.6 COOLING CAPACITY TOTAL INPUT SHC AIR VOLUME 80 1,330 0.977 0.991 0.968 CMM L/S Factor for Various Air Flow PE-10MYC-EU PEH-10MYA-EU 0.41 1,550 1.0 1.0 1.0 90 SHC:SENSIBLE HEAT CAPACITY 15.1 14.8 0.41 10.0 9.9 0.50 17.3 34.6 35.7 9.8 0.60 9.6 0.72 23.2 32.4 20.1 9.5 0.80 26.0 32.4 33.5 10.0 9.9 9.8 9.6 9.5 9.4 9.9 9.8 9.6 9.5 9.4 9.3 9.6 9.5 9.4 9.3 9.2 9.2 9.4 9.3 9.2 9.2 9.1 9.2 9.2 9.1 T/I kW 0.28 0.36 0.46 0.58 0.65 0.82 0.22 0.30 0.41 0.48 0.63 0.76 0.23 0.31 0.45 0.55 0.68 0.84 0.27 0.37 0.49 0.63 0.80 0.29 0.42 0.55 SHF 9.9 12.6 15.3 18.6 21.1 24.6 7.6 10.0 13.1 15.6 19.0 22.2 7.6 10.2 13.4 16.1 19.1 22.8 8.1 10.8 13.8 17.2 20.8 8.2 11.3 14.5 SHCkW 35.0 14.4 0.42 10.7 10.6 0.51 16.8 33.1 34.2 10.4 0.61 10.3 0.73 22.7 31.0 19.6 10.2 0.82 25.3 31.0 32.0 10.7 0.28 10.6 9.6 0.37 34.2 12.2 10.4 0.46 14.8 32.0 33.1 10.3 10.2 10.1 10.6 10.4 10.3 10.2 10.1 10.0 10.3 10.2 10.1 10.0 9.9 9.8 10.1 10.0 9.9 9.8 9.7 9.9 9.8 9.7 T/I kW 0.59 0.67 0.84 0.22 0.30 0.41 0.48 0.64 0.78 0.24 0.32 0.45 0.56 0.69 0.86 0.27 0.38 0.50 0.64 0.81 0.29 0.42 0.56 SHF 18.2 20.7 24.2 7.4 9.6 12.6 15.0 18.5 21.7 7.3 9.8 13.1 15.6 18.7 22.3 7.8 10.5 13.3 16.7 20.4 7.9 10.9 14.0 SHCkW 31.0 31.0 28.8 33.1 32.0 31.0 31.0 28.8 27.9 31.0 31.0 28.8 27.9 26.9 26.0 28.8 27.9 26.9 26.0 25.1 26.9 26.0 25.1 Q kW OUTDOOR DB˚C 35.7 34.6 33.5 32.4 32.4 30.1 34.6 33.5 32.4 32.4 30.1 29.1 32.4 32.4 30.1 29.1 28.1 27.1 30.1 29.1 28.1 27.1 26.1 28.1 27.1 26.1 Q kW 30.0 100 1,660 1.035 1.005 1.037 40.0 14.0 0.43 11.5 11.4 0.52 16.4 31.4 32.5 11.2 0.63 11.1 0.76 22.3 29.4 19.1 11.0 0.85 25.1 29.4 30.4 11.5 0.29 9.3 11.4 32.5 0.38 11.2 0.48 14.5 30.4 11.8 11.1 0.61 17.8 29.4 31.4 11.0 10.9 11.4 11.2 11.1 11.0 10.9 10.8 11.1 11.0 10.9 10.8 10.7 10.6 10.9 10.8 10.7 10.6 10.5 10.7 10.6 10.5 T/I kW 0.69 0.86 0.22 0.31 0.42 0.50 0.66 0.80 0.24 0.32 0.46 0.58 0.71 0.88 0.27 0.38 0.51 0.66 0.83 0.30 0.43 0.57 SHF 20.2 23.6 7.1 9.3 12.3 14.7 18.0 21.2 7.0 9.5 12.6 15.3 18.2 21.8 7.5 10.1 13.0 16.3 19.9 7.6 10.5 13.6 SHCkW 29.4 27.3 31.4 30.4 29.4 29.4 27.3 26.5 29.4 29.4 27.3 26.5 25.6 24.7 27.3 26.5 25.6 24.7 23.9 25.6 24.7 23.9 Q kW T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.) 9.4 36.9 8.9 0.40 15.4 38.0 24 9.3 0.49 17.6 35.9 8.5 0.49 17.9 36.9 23 9.2 0.59 20.3 8.7 0.58 20.8 35.8 22 34.7 8.6 0.70 24.1 34.6 21 9.0 0.79 26.5 33.6 8.5 0.78 27.0 9.4 9.3 0.27 0.36 10.1 12.8 36.9 9.2 9.1 9.0 8.9 35.9 0.44 0.56 0.64 9.3 9.2 9.1 9.0 8.9 8.8 9.1 9.0 8.9 8.8 8.7 8.6 8.9 8.8 8.7 8.6 8.5 8.7 8.6 8.5 T/I kW 8.8 34.6 20 0.35 15.4 18.9 21.4 0.80 0.22 0.30 0.40 0.48 0.62 0.75 0.23 0.31 0.44 0.54 0.67 0.83 0.27 0.37 0.49 0.63 0.78 0.29 0.42 0.55 SHF 34.7 33.6 33.6 24.9 7.8 10.3 13.5 16.0 19.4 22.7 7.8 10.5 13.8 16.4 19.5 23.3 8.3 11.1 14.2 17.6 21.2 8.5 11.7 14.8 SHCkW 25.0 8.7 8.6 8.5 8.4 35.9 8.8 31.2 34.7 33.6 33.6 31.2 8.7 8.4 8.5 8.4 30.2 33.6 8.6 8.3 33.6 31.2 30.2 29.1 28.1 31.2 30.2 29.1 28.1 27.0 29.1 28.1 27.0 Q kW 8.5 8.4 8.3 8.3 8.2 8.4 8.3 8.3 8.2 8.1 8.3 8.2 8.1 T/I kW 8.9 38.0 24 13.0 0.44 0.55 0.63 0.79 0.22 0.29 0.40 0.47 0.61 0.74 0.23 0.31 0.44 0.54 0.66 0.82 0.26 0.36 0.48 0.62 0.77 0.29 0.41 0.54 SHF 0.27 36.9 23 15.7 19.1 21.7 25.3 8.0 10.4 13.7 16.2 19.7 23.0 8.1 10.8 14.1 16.8 19.9 23.7 8.4 11.3 14.4 17.8 21.5 8.7 11.9 15.1 SHCkW 10.3 35.8 34.6 20 22 32.1 19 34.6 36.9 23 21 35.8 22 32.1 19 34.6 31.1 18 21 34.6 21 34.6 34.6 20 20 32.1 30.0 17 19 28.9 16 31.1 32.1 19 18 31.1 28.9 16 18 27.8 15 30.0 30.0 17 17 28.9 27.8 15 16 Q kW WB ˚C 20.0 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR PE-10MYC-EU , PEH-10MYA-EU (combined with PUH-10MYC2-EU) Cooling Capacity (Standard Air Flow) 12.0 12.1 12.2 11.7 11.8 12.0 12.1 12.3 12.4 11.8 12.0 12.1 12.3 12.4 0.31 0.23 0.89 0.71 0.62 0.49 0.38 0.29 0.89 0.78 0.65 0.53 0.44 9.0 6.7 22.8 19.5 17.1 14.0 11.3 8.8 24.5 21.6 18.5 15.7 13.4 29.5 25.7 27.6 27.6 28.6 29.5 30.5 27.6 27.6 28.6 29.5 30.5 12.0 20.6 24.9 28.6 11.8 0.24 6.7 27.6 11.8 11.7 0.33 9.1 27.6 0.43 11.6 0.48 12.2 25.7 11.9 11.5 0.59 14.8 24.9 27.6 11.4 0.73 17.6 24.1 11.7 11.7 0.91 21.2 23.3 0.52 11.6 0.28 7.1 25.7 14.2 11.5 0.39 9.7 24.9 27.6 11.4 0.52 12.5 24.1 11.6 11.3 0.67 15.7 23.3 0.68 11.5 0.85 19.2 22.5 17.5 11.4 0.30 7.2 24.1 25.7 11.3 0.43 10.0 23.3 0.83 T/I kW SHF 0.58 13.1 22.5 46.0 SHCkW Q kW - 27 - 0.39 0.28 0.74 0.59 0.46 0.35 0.25 0.79 0.63 0.52 0.42 0.31 0.22 0.69 12.3 9.1 22.0 18.4 14.8 11.7 8.8 24.4 20.6 17.6 14.7 11.3 8.6 23.5 31.1 32.5 29.7 31.1 32.5 33.9 35.3 31.1 32.5 33.9 35.3 36.7 38.1 33.9 16 17 15 16 17 18 19 16 17 18 19 20 21 18 0.45 0.39 18.5 16.0 40.9 40.5 24 0.66 25.0 38.1 21 23 0.76 28.0 36.7 20 0.55 0.27 10.8 40.5 24 21.9 0.33 13.6 40.9 23 39.5 0.41 16.3 39.5 22 22 0.52 20 0.61 0.74 26.1 35.3 19 19.6 0.20 8.4 40.9 23 22.4 0.27 10.8 39.5 22 38.1 0.37 14.1 38.1 21 36.7 0.45 16.7 36.7 20 21 0.57 20.2 35.3 19 38.0 39.4 40.8 40.4 36.6 38.0 39.4 40.8 40.4 8.1 8.2 8.2 8.3 8.0 8.1 8.2 8.2 8.3 15.9 18.5 21.7 24.9 27.8 10.7 13.5 16.2 19.6 22.3 26.0 8.3 10.7 14.1 16.6 20.1 23.4 8.5 11.3 14.6 17.5 20.5 24.3 8.7 11.7 14.8 18.3 0.39 0.45 0.55 0.65 0.76 0.27 0.33 0.41 0.52 0.61 0.74 0.20 0.27 0.37 0.45 0.57 0.69 0.22 0.31 0.41 0.52 0.63 0.79 0.25 0.34 0.46 0.59 COOLING PE-10MYC-EU PEH-10MYA-EU CAPACITY TOTAL INPUT SHC AIR VOLUME 39.2 40.6 40.1 36.4 37.8 39.2 40.6 40.1 8.5 8.6 8.6 8.3 8.4 8.5 8.6 8.6 80 1,330 0.977 0.991 0.968 CMM L/S 90 1,550 1.0 1.0 1.0 1,660 1.035 1.005 1.037 100 37.8 8.4 15.8 18.4 21.6 24.8 27.7 10.7 13.4 16.2 19.5 22.2 25.9 8.3 10.7 14.0 16.6 20.1 23.4 8.4 11.2 14.5 17.4 20.4 24.3 8.7 11.6 14.7 18.2 0.39 0.45 0.55 0.66 0.76 0.27 0.33 0.41 0.52 0.61 0.74 0.20 0.27 0.37 0.46 0.57 0.70 0.22 0.31 0.41 0.52 0.63 0.79 0.25 0.35 0.46 0.59 36.0 37.4 38.8 40.2 39.6 36.0 37.4 38.8 40.2 39.6 8.6 8.7 8.8 8.9 9.0 8.6 8.7 8.8 8.9 9.0 33.2 8.5 34.6 37.4 8.7 8.6 36.0 8.6 40.2 34.6 8.6 8.9 33.2 8.5 38.8 31.8 8.4 8.8 30.4 8.3 37.4 34.6 8.6 8.7 33.2 8.5 36.0 31.8 8.4 8.6 30.4 8.3 34.6 29.0 8.1 8.6 0.28 8.9 31.8 8.4 15.7 18.2 21.3 24.5 27.5 10.6 13.3 16.0 19.4 22.1 25.7 8.2 10.6 13.9 16.5 19.9 23.2 8.3 11.0 14.4 17.2 20.2 24.1 8.6 11.5 14.6 18.1 0.40 0.45 0.55 0.66 0.76 0.27 0.33 0.41 0.52 0.61 0.74 0.20 0.27 0.37 0.46 0.58 0.70 0.22 0.31 0.42 0.52 0.64 0.79 0.25 0.35 0.46 0.60 0.75 0.40 12.1 30.4 8.3 21.8 0.53 15.5 SHF 29.0 Q kW SHCkW 8.1 T/I kW 10.0 35.4 36.3 37.2 38.0 38.9 35.4 36.3 37.2 38.0 38.9 9.1 9.1 9.2 9.3 9.5 9.1 9.1 9.2 9.3 9.5 32.6 8.9 34.0 36.3 9.1 9.0 35.4 9.1 38.0 34.0 9.0 9.3 32.6 8.9 37.2 31.3 8.8 9.2 29.9 8.7 36.3 34.0 9.0 9.1 32.6 8.9 35.4 31.3 8.8 9.1 29.9 8.7 34.0 28.5 8.6 9.0 0.28 8.8 31.3 8.8 15.5 18.1 21.1 24.3 27.2 10.4 13.2 15.9 19.3 21.9 25.5 8.1 10.5 13.8 16.4 19.8 23.1 8.2 10.9 14.2 17.0 20.0 23.9 8.5 11.4 14.5 18.0 0.40 0.48 0.57 0.67 0.77 0.27 0.35 0.43 0.53 0.62 0.75 0.21 0.28 0.38 0.46 0.58 0.71 0.23 0.31 0.42 0.52 0.64 0.80 0.25 0.35 0.46 0.60 0.76 0.40 12.0 29.9 8.7 21.6 0.54 15.3 SHF 28.5 Q kW SHCkW 8.6 T/I kW 15.0 17.9 17.8 17 18 19 20 21 22 23 24 25 26 27 9.3 9.2 9.3 9.3 9.4 9.6 9.3 9.3 9.4 9.6 9.7 10.0 10.0 9.9 9.8 9.7 10.0 10.0 9.9 9.8 9.7 9.6 10.0 9.9 9.8 9.7 9.6 9.4 27.2 27.4 27.6 27.7 27.8 27.9 28.0 28.1 28.1 28.3 28.4 28.5 28.6 8.5 8.4 8.4 8.3 8.2 8.1 8.1 8.0 7.9 7.8 7.8 7.6 7.7 6.8 6.7 6.7 6.6 6.6 6.5 6.5 6.5 6.4 6.4 31.1 31.4 31.6 31.7 31.8 32.0 32.1 32.2 32.3 32.5 32.6 32.7 32.8 9.6 9.5 9.4 9.3 9.2 9.1 9.1 9.0 8.9 8.8 8.7 8.5 8.6 T/I kW 10.0 OUTDOOR WB ˚C 20.3 20.4 20.5 20.6 20.7 20.8 20.9 21.0 21.1 21.2 6.3 6.3 6.3 ) 35.4 35.6 35.9 36.1 36.2 36.4 36.6 36.8 36.9 37.0 37.1 37.2 37.3 Q kW HEATING PEH-10MYA-EU 80 1,330 0.989 1.025 CMM L/S CAPACITY TOTAL INPUT AIR VOLUME 90 1,500 1.0 1.0 1,660 1.008 0.984 100 10.8 10.7 10.5 10.4 10.3 10.3 10.2 10.1 10.0 9.9 9.7 9.5 9.6 T/I kW 7.6 7.5 7.5 7.4 7.3 7.3 7.2 7.1 7.1 7.0 7.0 6.9 6.9 T/I kW 15.0 23.6 23.7 23.9 24.0 24.1 24.2 24.3 24.3 24.4 24.5 24.6 24.5 24.8 0.0 Factor for Various Air Flow ( 6.1 6.1 6.0 6.0 6.0 6.0 5.9 5.9 5.9 5.9 21.3 205.8 21.4 Q kW T/I kW Q kW 5.0 17.3 17.4 17.5 17.6 17.7 18.0 18.1 18.2 5.8 5.8 5.8 Q kW * Q:HEATING CAPACITY T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 62/125Pa”. 27 26 25 24 23 22 21 20 19 18 17 16 15 DB ˚C INDOOR 18.2 16 9.3 9.8 18.3 15 9.2 18.4 DB ˚C T/I kW -5.0 OUTDOOR WB ˚C Q kW T/I kW Q kW -10.0 T/I kW INDOOR PEH-10MYA-EU (combined with PUH-10MYC2-EU) Heating Capacity (Standard Air Flow) T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.) 36.4 8.3 33.6 8.2 35.0 37.8 8.4 8.2 36.4 8.3 40.6 35.0 8.2 8.6 33.6 8.2 39.2 32.2 8.1 8.5 30.8 8.0 37.8 35.0 8.2 8.4 33.6 8.2 36.4 32.2 8.1 8.3 30.8 8.0 35.0 29.4 7.8 8.2 0.28 9.0 32.2 8.1 0.74 0.39 12.2 30.8 8.0 21.9 0.53 15.6 29.4 SHF Q kW SHCkW 5.0 OUTDOOR DB˚C 7.8 T/I kW SHC:SENSIBLE HEAT CAPACITY 36.6 8.0 33.8 7.9 35.2 38.0 8.1 7.9 36.6 8.0 40.8 35.2 7.9 8.2 33.8 7.9 39.4 32.4 7.8 8.2 31.0 7.7 38.0 35.2 7.9 8.1 33.8 7.9 36.6 32.4 7.8 8.0 31.0 7.7 35.2 29.6 7.5 7.9 0.28 9.1 32.4 7.8 0.74 0.39 12.2 31.0 7.7 22.0 0.53 15.7 29.6 SHF Q kW SHC kW 7.5 T/I kW 0.0 Factor for Various Air Flow Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 15 0.53 SHF 15.8 Q kW SHCkW -5.0 29.7 DB˚C WB ˚C INDOOR PE-10MYC-EU , PEH-10MYA-EU (combined with PUH-10MYC2-EU) Cooling Capacity (Standard Air Flow) (Use for low ambient cooling parts) - 28 9.1 0.70 23.6 33.6 COOLING CAPACITY TOTAL INPUT SHC AIR VOLUME 80 1,330 0.977 0.991 0.968 CMM L/S Factor for Various Air Flow PE-10MYC-EU PEH-10MYA-EU 0.41 1,550 1.0 1.0 1.0 90 SHC:SENSIBLE HEAT CAPACITY 15.1 14.8 0.41 10.0 9.9 0.50 17.3 34.6 35.7 9.8 0.60 9.6 0.72 23.2 32.4 20.1 9.5 0.80 26.0 32.4 33.5 10.0 9.9 9.8 9.6 9.5 9.4 9.9 9.8 9.6 9.5 9.4 9.3 9.6 9.5 9.4 9.3 9.2 9.2 9.4 9.3 9.2 9.2 9.1 9.2 9.2 9.1 T/I kW 0.28 0.36 0.46 0.58 0.65 0.82 0.22 0.30 0.41 0.48 0.63 0.76 0.23 0.31 0.45 0.55 0.68 0.84 0.27 0.37 0.49 0.63 0.80 0.29 0.42 0.55 SHF 9.9 12.6 15.3 18.6 21.1 24.6 7.6 10.0 13.1 15.6 19.0 22.2 7.6 10.2 13.4 16.1 19.1 22.8 8.1 10.8 13.8 17.2 20.8 8.2 11.3 14.5 SHCkW 35.0 14.4 0.42 10.7 10.6 0.51 16.8 33.1 34.2 10.4 0.61 10.3 0.73 22.7 31.0 19.6 10.2 0.82 25.3 31.0 32.0 10.7 0.28 10.6 9.6 0.37 34.2 12.2 10.4 0.46 14.8 32.0 33.1 10.3 10.2 10.1 10.6 10.4 10.3 10.2 10.1 10.0 10.3 10.2 10.1 10.0 9.9 9.8 10.1 10.0 9.9 9.8 9.7 9.9 9.8 9.7 T/I kW 0.59 0.67 0.84 0.22 0.30 0.41 0.48 0.64 0.78 0.24 0.32 0.45 0.56 0.69 0.86 0.27 0.38 0.50 0.64 0.81 0.29 0.42 0.56 SHF 18.2 20.7 24.2 7.4 9.6 12.6 15.0 18.5 21.7 7.3 9.8 13.1 15.6 18.7 22.3 7.8 10.5 13.3 16.7 20.4 7.9 10.9 14.0 SHCkW 31.0 31.0 28.8 33.1 32.0 31.0 31.0 28.8 27.9 31.0 31.0 28.8 27.9 26.9 26.0 28.8 27.9 26.9 26.0 25.1 26.9 26.0 25.1 Q kW OUTDOOR DB˚C 35.7 34.6 33.5 32.4 32.4 30.1 34.6 33.5 32.4 32.4 30.1 29.1 32.4 32.4 30.1 29.1 28.1 27.1 30.1 29.1 28.1 27.1 26.1 28.1 27.1 26.1 Q kW 30.0 100 1,660 1.035 1.005 1.037 40.0 14.0 0.43 11.5 11.4 0.52 16.4 31.4 32.5 11.2 0.63 11.1 0.76 22.3 29.4 19.1 11.0 0.85 25.1 29.4 30.4 11.5 0.29 9.3 11.4 32.5 0.38 11.2 0.48 14.5 30.4 11.8 11.1 0.61 17.8 29.4 31.4 11.0 10.9 11.4 11.2 11.1 11.0 10.9 10.8 11.1 11.0 10.9 10.8 10.7 10.6 10.9 10.8 10.7 10.6 10.5 10.7 10.6 10.5 T/I kW 0.69 0.86 0.22 0.31 0.42 0.50 0.66 0.80 0.24 0.32 0.46 0.58 0.71 0.88 0.27 0.38 0.51 0.66 0.83 0.30 0.43 0.57 SHF 20.2 23.6 7.1 9.3 12.3 14.7 18.0 21.2 7.0 9.5 12.6 15.3 18.2 21.8 7.5 10.1 13.0 16.3 19.9 7.6 10.5 13.6 SHCkW 29.4 27.3 31.4 30.4 29.4 29.4 27.3 26.5 29.4 29.4 27.3 26.5 25.6 24.7 27.3 26.5 25.6 24.7 23.9 25.6 24.7 23.9 Q kW T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.) 9.4 36.9 8.9 0.40 15.4 38.0 24 9.3 0.49 17.6 35.9 8.5 0.49 17.9 36.9 23 9.2 0.59 20.3 8.7 0.58 20.8 35.8 22 34.7 8.6 0.70 24.1 34.6 21 9.0 0.79 26.5 33.6 8.5 0.78 27.0 9.4 9.3 0.27 0.36 10.1 12.8 36.9 9.2 9.1 9.0 8.9 35.9 0.44 0.56 0.64 9.3 9.2 9.1 9.0 8.9 8.8 9.1 9.0 8.9 8.8 8.7 8.6 8.9 8.8 8.7 8.6 8.5 8.7 8.6 8.5 T/I kW 8.8 34.6 20 0.35 15.4 18.9 21.4 0.80 0.22 0.30 0.40 0.48 0.62 0.75 0.23 0.31 0.44 0.54 0.67 0.83 0.27 0.37 0.49 0.63 0.78 0.29 0.42 0.55 SHF 34.7 33.6 33.6 24.9 7.8 10.3 13.5 16.0 19.4 22.7 7.8 10.5 13.8 16.4 19.5 23.3 8.3 11.1 14.2 17.6 21.2 8.5 11.7 14.8 SHCkW 25.0 8.7 8.6 8.5 8.4 35.9 8.8 31.2 34.7 33.6 33.6 31.2 8.7 8.4 8.5 8.4 30.2 33.6 8.6 8.3 33.6 31.2 30.2 29.1 28.1 31.2 30.2 29.1 28.1 27.0 29.1 28.1 27.0 Q kW 8.5 8.4 8.3 8.3 8.2 8.4 8.3 8.3 8.2 8.1 8.3 8.2 8.1 T/I kW 8.9 38.0 24 13.0 0.44 0.55 0.63 0.79 0.22 0.29 0.40 0.47 0.61 0.74 0.23 0.31 0.44 0.54 0.66 0.82 0.26 0.36 0.48 0.62 0.77 0.29 0.41 0.54 SHF 0.27 36.9 23 15.7 19.1 21.7 25.3 8.0 10.4 13.7 16.2 19.7 23.0 8.1 10.8 14.1 16.8 19.9 23.7 8.4 11.3 14.4 17.8 21.5 8.7 11.9 15.1 SHCkW 10.3 35.8 34.6 20 22 32.1 19 34.6 36.9 23 21 35.8 22 32.1 19 34.6 31.1 18 21 34.6 21 34.6 34.6 20 20 32.1 30.0 17 19 28.9 16 31.1 32.1 19 18 31.1 28.9 16 18 27.8 15 30.0 30.0 17 17 28.9 27.8 15 16 Q kW WB ˚C 20.0 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR PE-10MYC-EU , PEH-10MYA-EU (combined with PUH-10MYE1-EU) Cooling Capacity (Standard Air Flow) 12.0 12.1 12.2 11.7 11.8 12.0 12.1 12.3 12.4 11.8 12.0 12.1 12.3 12.4 0.31 0.23 0.89 0.71 0.62 0.49 0.38 0.29 0.89 0.78 0.65 0.53 0.44 9.0 6.7 22.8 19.5 17.1 14.0 11.3 8.8 24.5 21.6 18.5 15.7 13.4 29.5 25.7 27.6 27.6 28.6 29.5 30.5 27.6 27.6 28.6 29.5 30.5 12.0 20.6 24.9 28.6 11.8 0.24 6.7 27.6 11.8 11.7 0.33 9.1 27.6 0.43 11.6 0.48 12.2 25.7 11.9 11.5 0.59 14.8 24.9 27.6 11.4 0.73 17.6 24.1 11.7 11.7 0.91 21.2 23.3 0.52 11.6 0.28 7.1 25.7 14.2 11.5 0.39 9.7 24.9 27.6 11.4 0.52 12.5 24.1 11.6 11.3 0.67 15.7 23.3 0.68 11.5 0.85 19.2 22.5 17.5 11.4 0.30 7.2 24.1 25.7 11.3 0.43 10.0 23.3 0.83 T/I kW SHF 0.58 13.1 22.5 46.0 SHCkW Q kW - 29 - 0.39 0.28 0.74 0.59 0.46 0.35 0.25 0.79 0.63 0.52 0.42 0.31 0.22 0.69 12.3 9.1 22.0 18.4 14.8 11.7 8.8 24.4 20.6 17.6 14.7 11.3 8.6 23.5 31.1 32.5 29.7 31.1 32.5 33.9 35.3 31.1 32.5 33.9 35.3 36.7 38.1 33.9 16 17 15 16 17 18 19 16 17 18 19 20 21 18 0.45 0.39 18.5 16.0 40.9 40.5 24 0.66 25.0 38.1 21 23 0.76 28.0 36.7 20 0.55 0.27 10.8 40.5 24 21.9 0.33 13.6 40.9 23 39.5 0.41 16.3 39.5 22 22 0.52 20 0.61 0.74 26.1 35.3 19 19.6 0.20 8.4 40.9 23 22.4 0.27 10.8 39.5 22 38.1 0.37 14.1 38.1 21 36.7 0.45 16.7 36.7 20 21 0.57 20.2 35.3 19 38.0 39.4 40.8 40.4 36.6 38.0 39.4 40.8 40.4 8.1 8.2 8.2 8.3 8.0 8.1 8.2 8.2 8.3 15.9 18.5 21.7 24.9 27.8 10.7 13.5 16.2 19.6 22.3 26.0 8.3 10.7 14.1 16.6 20.1 23.4 8.5 11.3 14.6 17.5 20.5 24.3 8.7 11.7 14.8 18.3 0.39 0.45 0.55 0.65 0.76 0.27 0.33 0.41 0.52 0.61 0.74 0.20 0.27 0.37 0.45 0.57 0.69 0.22 0.31 0.41 0.52 0.63 0.79 0.25 0.34 0.46 0.59 COOLING PE-10MYC-EU PEH-10MYA-EU CAPACITY TOTAL INPUT SHC AIR VOLUME 39.2 40.6 40.1 36.4 37.8 39.2 40.6 40.1 8.5 8.6 8.6 8.3 8.4 8.5 8.6 8.6 80 1,330 0.977 0.991 0.968 CMM L/S 90 1,550 1.0 1.0 1.0 1,660 1.035 1.005 1.037 100 37.8 8.4 15.8 18.4 21.6 24.8 27.7 10.7 13.4 16.2 19.5 22.2 25.9 8.3 10.7 14.0 16.6 20.1 23.4 8.4 11.2 14.5 17.4 20.4 24.3 8.7 11.6 14.7 18.2 0.39 0.45 0.55 0.66 0.76 0.27 0.33 0.41 0.52 0.61 0.74 0.20 0.27 0.37 0.46 0.57 0.70 0.22 0.31 0.41 0.52 0.63 0.79 0.25 0.35 0.46 0.59 36.0 37.4 38.8 40.2 39.6 36.0 37.4 38.8 40.2 39.6 8.6 8.7 8.8 8.9 9.0 8.6 8.7 8.8 8.9 9.0 33.2 8.5 34.6 37.4 8.7 8.6 36.0 8.6 40.2 34.6 8.6 8.9 33.2 8.5 38.8 31.8 8.4 8.8 30.4 8.3 37.4 34.6 8.6 8.7 33.2 8.5 36.0 31.8 8.4 8.6 30.4 8.3 34.6 29.0 8.1 8.6 0.28 8.9 31.8 8.4 15.7 18.2 21.3 24.5 27.5 10.6 13.3 16.0 19.4 22.1 25.7 8.2 10.6 13.9 16.5 19.9 23.2 8.3 11.0 14.4 17.2 20.2 24.1 8.6 11.5 14.6 18.1 0.40 0.45 0.55 0.66 0.76 0.27 0.33 0.41 0.52 0.61 0.74 0.20 0.27 0.37 0.46 0.58 0.70 0.22 0.31 0.42 0.52 0.64 0.79 0.25 0.35 0.46 0.60 0.75 0.40 12.1 30.4 8.3 21.8 0.53 15.5 SHF 29.0 Q kW SHCkW 8.1 T/I kW 10.0 35.4 36.3 37.2 38.0 38.9 35.4 36.3 37.2 38.0 38.9 9.1 9.1 9.2 9.3 9.5 9.1 9.1 9.2 9.3 9.5 32.6 8.9 34.0 36.3 9.1 9.0 35.4 9.1 38.0 34.0 9.0 9.3 32.6 8.9 37.2 31.3 8.8 9.2 29.9 8.7 36.3 34.0 9.0 9.1 32.6 8.9 35.4 31.3 8.8 9.1 29.9 8.7 34.0 28.5 8.6 9.0 0.28 8.8 31.3 8.8 15.5 18.1 21.1 24.3 27.2 10.4 13.2 15.9 19.3 21.9 25.5 8.1 10.5 13.8 16.4 19.8 23.1 8.2 10.9 14.2 17.0 20.0 23.9 8.5 11.4 14.5 18.0 0.40 0.48 0.57 0.67 0.77 0.27 0.35 0.43 0.53 0.62 0.75 0.21 0.28 0.38 0.46 0.58 0.71 0.23 0.31 0.42 0.52 0.64 0.80 0.25 0.35 0.46 0.60 0.76 0.40 12.0 29.9 8.7 21.6 0.54 15.3 SHF 28.5 Q kW SHCkW 8.6 T/I kW 15.0 17.9 17.8 17 18 19 20 21 22 23 24 25 26 27 9.3 9.2 9.3 9.3 9.4 9.6 9.3 9.3 9.4 9.6 9.7 10.0 10.0 9.9 9.8 9.7 10.0 10.0 9.9 9.8 9.7 9.6 10.0 9.9 9.8 9.7 9.6 9.4 27.2 27.4 27.6 27.7 27.8 27.9 28.0 28.1 28.1 28.3 28.4 28.5 28.6 8.5 8.4 8.4 8.3 8.2 8.1 8.1 8.0 7.9 7.8 7.8 7.6 7.7 6.8 6.7 6.7 6.6 6.6 6.5 6.5 6.5 6.4 6.4 31.1 31.4 31.6 31.7 31.8 32.0 32.1 32.2 32.3 32.5 32.6 32.7 32.8 9.6 9.5 9.4 9.3 9.2 9.1 9.1 9.0 8.9 8.8 8.7 8.5 8.6 T/I kW 10.0 OUTDOOR WB ˚C 20.3 20.4 20.5 20.6 20.7 20.8 20.9 21.0 21.1 21.2 6.3 6.3 6.3 ) 35.4 35.6 35.9 36.1 36.2 36.4 36.6 36.8 36.9 37.0 37.1 37.2 37.3 Q kW HEATING PEH-10MYA-EU 80 1,330 0.989 1.025 CMM L/S CAPACITY TOTAL INPUT AIR VOLUME 90 1,500 1.0 1.0 1,660 1.008 0.984 100 10.8 10.7 10.5 10.4 10.3 10.3 10.2 10.1 10.0 9.9 9.7 9.5 9.6 T/I kW 7.6 7.5 7.5 7.4 7.3 7.3 7.2 7.1 7.1 7.0 7.0 6.9 6.9 T/I kW 15.0 23.6 23.7 23.9 24.0 24.1 24.2 24.3 24.3 24.4 24.5 24.6 24.5 24.8 0.0 Factor for Various Air Flow ( 6.1 6.1 6.0 6.0 6.0 6.0 5.9 5.9 5.9 5.9 21.3 205.8 21.4 Q kW T/I kW Q kW 5.0 17.3 17.4 17.5 17.6 17.7 18.0 18.1 18.2 5.8 5.8 5.8 Q kW * Q:HEATING CAPACITY T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 62/125Pa”. 27 26 25 24 23 22 21 20 19 18 17 16 15 DB ˚C INDOOR 18.2 16 9.3 9.8 18.3 15 9.2 18.4 DB ˚C T/I kW -5.0 OUTDOOR WB ˚C Q kW T/I kW Q kW -10.0 T/I kW INDOOR PEH-10MYA-EU (combined with PUH-10MYE1-EU) Heating Capacity (Standard Air Flow) T/I:TOTAL INPUT (In case of “indoor fan external static pressure: ESP = 62/125Pa”.) 36.4 8.3 33.6 8.2 35.0 37.8 8.4 8.2 36.4 8.3 40.6 35.0 8.2 8.6 33.6 8.2 39.2 32.2 8.1 8.5 30.8 8.0 37.8 35.0 8.2 8.4 33.6 8.2 36.4 32.2 8.1 8.3 30.8 8.0 35.0 29.4 7.8 8.2 0.28 9.0 32.2 8.1 0.74 0.39 12.2 30.8 8.0 21.9 0.53 15.6 29.4 SHF Q kW SHCkW 5.0 OUTDOOR DB˚C 7.8 T/I kW SHC:SENSIBLE HEAT CAPACITY 36.6 8.0 33.8 7.9 35.2 38.0 8.1 7.9 36.6 8.0 40.8 35.2 7.9 8.2 33.8 7.9 39.4 32.4 7.8 8.2 31.0 7.7 38.0 35.2 7.9 8.1 33.8 7.9 36.6 32.4 7.8 8.0 31.0 7.7 35.2 29.6 7.5 7.9 0.28 9.1 32.4 7.8 0.74 0.39 12.2 31.0 7.7 22.0 0.53 15.7 29.6 SHF Q kW SHC kW 7.5 T/I kW 0.0 Factor for Various Air Flow Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 15 0.53 SHF 15.8 Q kW SHCkW -5.0 29.7 DB˚C WB ˚C INDOOR PE-10MYC-EU , PEH-10MYA-EU (combined with PUH-10MYE1-EU) Cooling Capacity (Standard Air Flow) (Use for low ambient cooling parts) - 30 - 25.1 19.5 14.3 39.7 33.5 28.8 23.7 18.4 14.0 38.0 47.0 48.5 50.2 52.1 47.0 48.5 50.2 52.1 53.8 55.8 50.2 16 17 18 19 16 17 18 19 20 21 18 32.8 27.5 23.5 17.9 14.1 42.3 36.3 31.8 26.8 22.4 18.0 45.7 40.8 35.4 30.6 26.8 53.8 55.8 57.7 59.6 52.1 53.8 55.8 57.7 59.6 61.5 53.8 55.8 57.7 59.6 61.5 20 21 22 23 19 20 21 22 23 24 20 21 22 23 24 35.8 52.1 19 30.3 45.5 15 15.2 48.5 17 20.4 26.1 47.0 45.5 15 SHCkW 16 Q kW WB ˚C 20.0 16.3 15.8 15.6 15.4 15.1 16.3 15.8 15.6 15.4 15.1 14.7 15.8 15.6 15.4 15.1 14.7 14.5 15.4 15.1 14.7 14.5 14.2 14.0 14.7 14.5 14.2 14.0 13.8 14.2 14.0 13.8 T/I kW 59.8 57.9 56.0 54.1 52.1 59.8 57.9 56.0 54.1 52.1 50.4 57.9 56.0 54.1 52.1 50.4 48.7 54.1 52.1 50.4 48.7 47.0 45.5 50.4 48.7 47.0 45.5 44.0 47.0 45.5 44.0 Q kW 26.5 30.0 34.6 40.0 45.0 17.7 22.0 26.2 31.0 35.4 41.3 13.8 17.5 23.1 27.0 32.1 37.1 13.5 17.8 23.0 28.2 32.7 38.9 13.8 19.2 24.9 29.9 35.0 14.8 20.0 25.7 SHCkW 25.0 0.44 0.52 0.62 0.74 0.86 0.30 0.38 0.47 0.57 0.68 0.82 0.24 0.31 0.43 0.52 0.64 0.76 0.25 0.34 0.46 0.58 0.70 0.85 0.27 0.39 0.53 0.66 0.79 0.32 0.44 0.58 SHF AIR VOLUME CAPACITY TOTAL INPUT SHC PE-15MYC1-EU COOLING 120 2,000 0.976 0.991 0.963 CMM L/S 2,334 1.0 1.0 1.0 140 SHC:SENSIBLE HEAT CAPACITY 0.44 0.51 0.61 0.73 0.85 0.29 0.38 0.46 0.57 0.67 0.81 0.24 0.31 0.42 0.51 0.63 0.76 0.25 0.34 0.46 0.57 0.69 0.85 0.27 0.39 0.52 0.65 0.79 0.31 0.43 0.57 SHF Factor for Various Air Flow Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR PE-15MYC1-EU 57.9 56.2 54.3 52.3 50.6 57.9 56.2 54.3 52.3 50.6 48.9 56.2 54.3 52.3 50.6 48.9 47.2 52.3 50.6 48.9 47.2 45.5 44.0 48.9 47.2 45.5 44.0 42.5 45.5 44.0 42.5 Q kW ( 26.6 29.9 34.2 39.4 44.5 17.2 21.5 25.7 30.4 34.8 40.6 13.5 17.2 22.6 26.6 31.6 36.7 13.1 17.5 22.6 27.7 32.1 38.3 13.5 18.7 24.3 29.3 34.5 14.2 19.4 25.1 SHCkW 30.0 0.46 0.53 0.63 0.75 0.88 0.30 0.38 0.47 0.58 0.69 0.83 0.24 0.32 0.43 0.53 0.65 0.78 0.25 0.35 0.46 0.59 0.71 0.87 0.28 0.40 0.54 0.67 0.81 0.31 0.44 0.59 SHF 17.9 17.6 17.2 17.0 16.7 17.9 17.6 17.2 17.0 16.7 16.5 17.6 17.2 17.0 16.7 16.5 16.3 17.0 16.7 16.5 16.3 15.8 15.6 16.5 16.3 15.8 15.6 15.4 15.8 15.6 15.4 T/I kW 55.5 54.1 52.1 50.6 48.7 55.5 54.1 52.1 50.6 48.7 47.0 54.1 52.1 50.6 48.7 47.0 45.5 50.6 48.7 47.0 45.5 44.0 42.5 47.0 45.5 44.0 42.5 41.0 44.0 42.5 41.0 Q kW OUTDOOR DB˚C 35.0 26.3 29.5 33.5 38.8 43.5 16.6 20.9 25.0 29.9 34.0 39.4 13.1 16.6 22.1 26.0 30.9 36.0 12.7 16.9 22.0 27.1 31.6 37.5 13.1 18.2 23.7 28.7 34.1 13.7 18.9 24.5 SHCkW 0.47 0.55 0.64 0.77 0.89 0.30 0.39 0.48 0.59 0.70 0.84 0.24 0.32 0.44 0.53 0.66 0.79 0.25 0.35 0.47 0.59 0.72 0.88 0.28 0.40 0.54 0.68 0.83 0.31 0.44 0.60 SHF 19.0 18.8 18.3 18.1 17.9 19.0 18.8 18.3 18.1 17.9 17.6 18.8 18.3 18.1 17.9 17.6 17.2 18.1 17.9 17.6 17.2 17.0 16.7 17.6 17.2 17.0 16.7 16.5 17.0 16.7 16.5 T/I kW 53.8 51.9 50.4 48.7 47.0 53.8 51.9 50.4 48.7 47.0 45.5 51.9 50.4 48.7 47.0 45.5 44.0 48.7 47.0 45.5 44.0 42.3 40.8 45.5 44.0 42.3 40.8 39.1 42.3 40.8 39.1 Q kW 40.0 26.4 29.2 33.3 38.1 42.7 16.2 20.4 24.8 29.7 34.0 39.5 12.5 16.2 21.6 25.6 30.5 35.4 12.4 16.7 21.7 26.7 31.0 36.8 12.9 17.9 23.2 28.1 32.9 13.5 18.4 23.8 SHCkW ) 0.49 0.56 0.66 0.78 0.91 0.30 0.39 0.49 0.61 0.72 0.87 0.24 0.32 0.44 0.55 0.67 0.80 0.26 0.35 0.48 0.61 0.73 0.90 0.28 0.41 0.55 0.69 0.84 0.32 0.45 0.61 SHF 2,660 1.025 1.009 1.044 160 T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 200Pa”. If you need “ESP = 100Pa”, please subtract “0.2kw” from “T/I value of this table”. 17.0 16.7 16.3 16.0 15.8 17.0 16.7 16.3 16.0 15.8 15.6 16.7 16.3 16.0 15.8 15.6 15.1 16.0 15.8 15.6 15.1 14.9 14.7 15.6 15.1 14.9 14.7 14.5 14.9 14.7 14.5 T/I kW Cooling Capacity (Standard Air Flow) 20.1 19.9 19.7 19.4 19.2 20.1 19.9 19.7 19.4 19.2 18.8 19.9 19.7 19.4 19.2 18.8 18.5 19.4 19.2 18.8 18.5 18.3 17.9 18.8 18.5 18.3 17.9 17.6 18.3 17.9 17.6 T/I kW 51.1 49.4 47.9 46.4 44.7 51.1 49.4 47.9 46.4 44.7 43.2 49.4 47.9 46.4 44.7 43.2 41.7 46.4 44.7 43.2 41.7 40.4 39.1 43.2 41.7 40.4 39.1 37.6 40.4 39.1 37.6 Q kW 46.0 25.7 28.6 32.4 37.0 41.2 15.4 19.7 24.2 29.3 33.4 38.8 11.9 15.5 20.9 24.9 29.5 34.1 12.0 16.1 21.0 25.8 30.2 36.1 12.5 17.4 22.6 27.3 32.0 13.2 18.0 23.1 SHCkW SHF 0.50 0.58 0.68 0.80 0.92 0.30 0.40 0.50 0.63 0.75 0.90 0.24 0.32 0.45 0.56 0.68 0.82 0.26 0.36 0.49 0.62 0.75 0.92 0.29 0.42 0.56 0.70 0.85 0.33 0.46 0.62 21.7 21.5 21.0 20.8 20.6 21.7 21.5 21.0 20.8 20.6 20.1 21.5 21.0 20.8 20.6 20.1 19.9 20.8 20.6 20.1 19.9 19.7 19.4 20.1 19.9 19.7 19.4 19.2 19.7 19.4 19.2 T/I kW - 31 - 52.2 47.0 21 18 55.8 57.6 24 52.2 21 23 50.4 20 54.0 57.6 24 22 55.8 50.4 20 23 48.8 19 54.0 55.8 23 22 54.0 22 52.2 52.2 21 21 50.4 20 48.8 50.4 20 19 48.8 45.4 17 19 44.0 16 47.0 48.8 19 18 47.0 44.0 16 18 42.6 15 45.4 45.4 17 17 44.0 42.6 15 16 Q kW WB ˚C 15.6 0.44 25.1 16.1 16.3 0.52 0.44 28.1 24.9 54.2 56.0 COOLING PEH-15MYA-EU CAPACITY TOTAL INPUT SHC AIR VOLUME 120 2,000 0.976 0.991 0.963 CMM L/S Factor for Various Air Flow 140 2,334 1.0 1.0 1.0 16.9 17.1 0.53 0.46 28.0 24.9 52.6 54.2 160 2,660 1.025 1.009 1.044 35.0 17.6 18.0 18.2 0.64 0.55 0.47 31.4 27.6 24.6 50.6 52.0 17.4 0.77 36.3 47.4 48.8 17.1 0.89 18.2 18.0 17.6 17.4 17.1 16.9 18.0 17.6 17.4 17.1 16.9 16.5 17.4 17.1 16.9 16.5 16.3 16.1 16.9 16.5 16.3 16.1 15.8 16.3 16.1 15.8 T/I kW 0.30 0.39 0.48 0.59 0.70 0.84 0.24 0.32 0.44 0.53 0.66 0.79 0.25 0.35 0.47 0.59 0.72 0.88 0.28 0.40 0.54 0.68 0.83 0.31 0.44 0.60 SHF 40.8 15.5 19.5 23.4 28.0 31.8 36.9 12.2 15.6 20.7 24.3 28.9 33.7 11.9 15.9 20.6 25.3 29.6 35.1 12.3 17.1 22.2 26.9 32.0 12.8 17.7 23.0 SHCkW 45.6 52.0 50.6 48.8 47.4 45.6 44.0 50.6 48.8 47.4 45.6 44.0 42.6 47.4 45.6 44.0 42.6 41.2 39.8 44.0 42.6 41.2 39.8 38.4 41.2 39.8 38.4 Q kW 40.0 18.9 19.1 19.3 0.66 0.56 0.49 27.3 24.7 48.6 50.4 18.7 0.78 35.7 45.6 31.2 18.4 0.91 40.0 44.0 47.2 19.3 0.30 19.1 18.9 18.7 18.4 18.0 19.1 18.9 18.7 18.4 18.0 17.8 18.7 18.4 18.0 17.8 17.6 17.1 18.0 17.8 17.6 17.1 16.9 17.6 17.1 16.9 T/I kW 0.39 0.49 0.61 0.72 0.87 0.24 0.32 0.44 0.55 0.67 0.80 0.26 0.35 0.48 0.61 0.73 0.90 0.28 0.41 0.55 0.69 0.84 0.32 0.45 0.61 SHF 15.1 19.1 23.2 27.9 31.8 37.0 11.7 15.2 20.2 24.0 28.6 33.1 11.6 15.6 20.3 25.0 29.0 34.4 12.1 16.8 21.7 26.3 30.8 12.6 17.2 22.2 SHCkW 50.4 48.6 47.2 45.6 44.0 42.6 48.6 47.2 45.6 44.0 42.6 41.2 45.6 44.0 42.6 41.2 39.6 38.2 42.6 41.2 39.6 38.2 36.6 39.6 38.2 36.6 Q kW case of “indoor fan external static pressure: ESP = 200Pa”. ( InIf you need “ESP = 100Pa”, please subtract “0.8kw” from “T/I value of this table”. ) 16.5 16.3 0.75 0.63 16.1 17.1 16.9 16.5 16.3 16.1 15.8 16.9 16.5 16.3 16.1 15.8 15.6 16.3 16.1 15.8 15.6 15.2 15.0 15.8 15.6 15.2 15.0 14.8 15.2 15.0 14.8 T/I kW 0.88 0.30 0.38 0.47 0.58 0.69 0.83 0.24 0.32 0.43 0.53 0.65 0.78 0.25 0.35 0.46 0.59 0.71 0.87 0.28 0.40 0.54 0.67 0.81 0.31 0.44 0.59 SHF OUTDOOR DB˚C 32.0 36.9 41.6 16.1 20.1 24.1 28.5 32.6 38.0 12.6 16.1 21.1 25.0 29.6 34.4 12.3 16.4 21.2 25.9 30.1 35.8 12.6 17.5 22.8 27.4 32.4 13.3 18.2 23.5 SHCkW 30.0 50.8 49.0 47.4 54.2 52.6 50.8 49.0 47.4 45.8 52.6 50.8 49.0 47.4 45.8 44.2 49.0 47.4 45.8 44.2 42.6 41.2 45.8 44.2 42.6 41.2 39.8 42.6 41.2 39.8 Q kW T/I:TOTAL INPUT 15.6 15.4 15.2 16.3 16.1 15.6 15.4 15.2 15.0 16.1 15.6 15.4 15.2 15.0 14.5 15.4 15.2 15.0 14.5 14.3 14.1 15.0 14.5 14.3 14.1 13.9 14.3 14.1 13.9 T/I kW 0.62 0.74 0.86 0.30 0.38 0.47 0.57 0.68 0.82 0.24 0.31 0.43 0.52 0.64 0.76 0.25 0.34 0.46 0.58 0.70 0.85 0.27 0.39 0.53 0.66 0.79 0.32 0.44 0.58 SHF 32.4 37.4 42.1 16.6 20.6 24.5 29.0 33.2 38.7 12.9 16.4 21.6 25.3 30.1 34.8 12.6 16.7 21.6 26.4 30.6 36.4 12.9 17.9 23.4 28.0 32.7 13.9 18.8 24.0 SHCkW 52.4 50.6 48.8 56.0 54.2 52.4 50.6 48.8 47.2 54.2 52.4 50.6 48.8 47.2 45.6 50.6 48.8 47.2 45.6 44.0 42.6 47.2 45.6 44.0 42.6 41.2 44.0 42.6 41.2 Q kW 25.0 SHC:SENSIBLE HEAT CAPACITY 15.2 0.51 28.6 14.8 14.5 15.6 15.2 15.0 14.8 14.5 14.1 15.2 15.0 14.8 14.5 14.1 13.9 14.8 14.5 14.1 13.9 13.7 13.5 14.1 13.9 13.7 13.5 13.2 13.7 13.5 13.2 T/I kW 15.0 0.73 0.85 0.29 0.38 0.46 0.57 0.67 0.81 0.24 0.31 0.42 0.51 0.63 0.76 0.25 0.34 0.46 0.57 0.69 0.85 0.27 0.39 0.52 0.65 0.79 0.31 0.43 0.57 SHF 0.61 33.2 38.1 42.8 16.9 21.0 25.1 29.8 34.0 39.6 13.2 16.8 21.9 25.8 30.8 35.6 13.1 17.2 22.2 27.0 31.3 37.2 13.4 18.3 23.5 28.4 33.5 14.2 19.1 24.5 SHCkW 20.0 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR PEH-15MYA-EU Cooling Capacity (Standard Air Flow) 20.2 20.6 20.8 0.50 24.1 47.8 19.7 34.7 43.4 0.58 20.8 0.92 38.6 41.8 26.7 20.6 0.30 14.4 47.8 46.2 20.2 0.40 18.5 46.2 20.0 20.0 0.50 22.6 44.8 0.68 19.7 0.63 27.4 43.4 30.3 19.3 0.75 31.2 41.8 44.8 20.6 0.90 36.3 40.4 0.80 20.2 0.24 11.1 46.2 19.1 20.0 20.0 0.82 31.9 39.0 0.32 19.7 0.26 11.3 43.4 14.5 19.3 0.36 15.0 41.8 44.8 19.1 0.49 19.6 40.4 19.7 18.9 0.62 24.1 39.0 0.45 18.7 0.75 28.2 37.8 19.6 19.3 0.92 33.8 36.6 43.4 19.1 0.29 11.7 40.4 19.3 18.9 0.42 16.3 39.0 0.56 18.7 0.56 21.2 37.8 23.3 18.4 0.70 25.6 36.6 41.8 18.9 0.85 30.0 35.2 0.68 18.7 0.33 12.3 37.8 27.6 18.4 0.46 16.8 36.6 40.4 T/I kW SHF 0.62 21.7 35.2 46.0 SHCkW Q kW - 32 - 54.8 49.4 21 18 0.24 0.81 0.67 0.57 0.46 0.37 0.28 0.83 0.72 13.8 41.4 35.6 31.3 26.1 21.8 17.5 44.2 39.6 56.6 58.4 51.2 53.0 54.8 56.6 58.4 62.6 53.0 54.8 23 19 20 21 22 23 24 20 21 0.61 0.51 0.41 34.7 29.6 25.6 56.6 58.4 62.6 23 24 0.31 22 17.5 0.41 22 22.7 54.8 0.50 21 26.7 0.63 0.76 0.26 0.35 0.46 0.57 0.69 0.85 0.28 0.38 0.50 0.64 0.80 0.31 0.43 0.57 53.0 32.2 37.3 14.1 18.4 23.5 28.1 32.7 38.8 14.4 19.0 23.8 29.3 35.0 14.9 19.8 25.3 SHF 20 51.2 53.0 19 51.2 20 47.6 17 19 45.8 16 49.4 51.2 19 18 49.4 45.8 16 18 44.0 15 47.6 47.6 17 17 45.8 16 44.0 Q kW SHCkW -5.0 AIR VOLUME CAPACITY TOTAL INPUT SHC PEH-15MYA-EU COOLING 120 2,000 0.976 0.991 0.963 CMM L/S 2,334 1.0 1.0 1.0 140 2,660 1.025 1.009 1.044 160 T/I:TOTAL INPUT 0.42 25.4 0.72 39.3 54.4 14.7 61.2 0.83 43.9 52.6 14.5 15.7 0.28 17.4 61.2 15.7 0.51 0.37 21.6 57.9 15.2 29.3 0.46 25.9 56.1 14.9 57.9 0.57 30.9 54.4 14.7 15.2 0.67 35.2 52.6 14.5 0.61 0.80 40.9 50.8 14.2 34.4 0.24 13.6 57.9 15.2 56.1 0.31 17.3 56.1 14.9 14.9 0.41 0.50 0.63 0.75 0.25 0.34 0.46 0.57 0.68 0.84 0.28 0.38 0.50 0.64 0.79 0.31 0.43 0.57 22.5 26.5 31.8 36.9 13.8 18.1 23.2 27.9 32.4 38.4 14.1 18.8 23.8 29.1 34.7 14.8 19.6 25.1 SHF 54.4 52.6 50.8 49.1 54.4 52.6 50.8 49.1 47.3 45.6 50.8 49.1 47.3 45.6 43.8 47.3 45.6 43.8 Q kW SHCkW 5.0 ( 51.6 53.5 55.3 57.2 59.0 51.6 53.5 15.3 15.6 15.8 16.1 16.6 15.3 15.6 59.0 49.9 15.1 16.6 57.2 16.1 57.2 55.3 15.8 16.1 53.5 15.6 55.3 51.6 15.3 15.8 49.9 48.2 53.5 51.6 49.9 48.2 46.6 44.9 49.9 48.2 46.6 44.9 43.2 46.6 44.9 43.2 25.2 28.8 33.6 38.5 43.2 17.0 21.2 25.3 30.2 34.4 40.0 13.4 17.0 22.1 26.0 31.1 36.0 13.3 17.5 22.6 27.3 31.7 37.6 13.6 18.4 23.6 28.6 33.9 14.4 19.3 24.7 Q kW SHCkW 15.1 14.6 15.6 15.3 15.1 14.6 14.3 14.1 15.1 14.6 14.3 14.1 13.9 14.3 14.1 13.9 T/I kW 0.43 0.50 0.61 0.72 0.84 0.29 0.37 0.46 0.56 0.67 0.80 0.23 0.31 0.41 0.50 0.62 0.75 0.25 0.34 0.45 0.57 0.68 0.84 0.27 0.38 0.51 0.64 0.78 0.31 0.43 0.57 SHF 15.0 11.2 11.2 11.2 11.2 11.2 11.2 11.2 11.2 11.4 28.5 28.5 28.5 28.3 28.1 28.1 28.1 27.7 27.7 26 27 15.0 14.5 14.3 14.1 13.9 15.0 14.5 14.3 14.1 13.9 13.9 14.5 14.3 14.1 14.9 14.9 14.7 14.7 14.5 14.3 14.3 14.0 14.0 13.8 13.8 13.6 13.6 47.5 47.7 48.1 48.1 48.3 48.5 48.5 48.7 48.7 48.9 49.1 49.3 49.3 16.5 16.5 16.3 16.1 16.1 15.8 15.6 15.4 15.4 15.2 15.2 15.6 14.7 T/I kW 10.0 HEATING PEH-15MYA-EU 13.6 13.4 13.4 13.4 13.2 13.2 12.9 12.9 12.7 12.7 12.7 12.5 12.5 T/I kW 53.7 53.9 54.3 54.3 54.5 54.7 54.7 54.9 54.9 55.3 55.3 55.5 55.7 Q kW 18.3 18.1 18.1 17.8 17.6 17.4 17.4 17.2 16.9 16.7 16.5 16.3 16.1 T/I kW 15.0 36.5 36.7 37.3 37.1 37.3 37.5 37.5 37.7 37.7 37.9 38.1 38.1 38.3 0.0 140 2,334 1.0 1.0 120 2,000 0.989 1.015 CMM L/S CAPACITY TOTAL INPUT AIR VOLUME Factor for Various Air Flow ( 41.7 42.1 42.5 42.5 42.5 42.7 42.9 42.9 42.9 43.3 43.3 43.5 43.5 12.3 12.3 12.3 12.3 12.0 12.0 12.0 11.8 11.8 11.8 11.6 OUTDOOR WB ˚C 31.9 32.1 32.5 32.3 32.5 32.7 32.7 32.9 32.9 33.1 33.3 11.6 11.6 Q kW 1.011 0.989 2,660 160 * Q:HEATING CAPACITY T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 200Pa”. If you need “ESP = 100Pa”, please subtract “0.8kw” from “T/I value of this table”. 27 26 25 24 23 22 21 20 19 18 17 16 15 DB ˚C 13.9 25 24 23 22 21 20 19 INDOOR ) 10.9 28.9 18 17 33.5 33.5 Q kW T/I kW Q kW 10.9 29.1 5.0 10.7 29.3 16 10.7 T/I kW -5.0 OUTDOOR WB ˚C Q kW T/I kW Q kW -10.0 29.5 15 DB ˚C INDOOR PEH-15MYA-EU Heating Capacity (Standard Air Flow) 13.9 13.2 14.1 13.9 13.9 13.2 13.0 120.8 13.9 13.2 13.0 12.8 12.6 13.0 12.8 12.6 T/I kW In case of “indoor fan external static pressure: ESP = 200Pa”. If you need “ESP = 100Pa”, please subtract “0.8kw” from “T/I value of this table”. 0.42 0.72 38.9 53.9 16.1 25.3 0.83 43.5 52.2 15.9 60.2 0.29 17.2 60.2 16.9 16.9 0.37 21.4 57.4 16.7 0.51 0.46 25.6 55.6 16.4 29.1 0.57 30.5 53.9 16.1 57.4 0.67 34.8 52.2 15.9 16.7 0.80 40.5 50.5 15.4 0.61 0.24 13.5 57.4 16.7 34.0 0.31 17.1 55.6 16.4 55.6 0.41 22.3 53.9 16.1 16.4 0.50 0.62 0.75 0.25 0.34 0.45 0.57 0.68 0.84 0.27 0.38 0.50 0.64 0.79 0.31 0.43 0.57 26.2 31.5 36.5 13.6 17.8 22.9 27.6 32.0 38.0 13.9 18.6 23.7 28.9 34.3 14.6 19.5 24.9 SHF 52.2 50.5 48.8 53.9 52.2 50.5 48.8 47.0 45.3 50.5 48.8 47.0 45.3 43.6 47.0 45.3 43.6 Q kW SHCkW 10.0 15.9 15.4 15.1 16.1 15.9 15.4 15.1 14.8 14.6 15.4 15.1 14.8 14.6 14.3 14.8 14.6 14.3 T/I kW OUTDOOR DB˚C 14.7 14.5 14.2 13.7 14.7 14.5 14.2 13.7 13.7 13.5 14.2 13.7 13.7 13.5 13.2 13.7 13.5 13.2 T/I kW SHC:SENSIBLE HEAT CAPACITY 0.41 25.5 62.0 0.72 39.4 54.6 13.5 14.4 0.83 44.0 52.8 13.3 0.51 0.28 17.4 62.0 14.4 29.5 0.37 21.7 58.1 14.2 58.1 0.46 26.0 56.3 13.7 14.2 0.57 31.1 54.6 13.5 0.61 0.67 35.4 52.8 13.3 34.5 0.81 41.1 51.0 13.1 56.3 0.24 13.7 58.1 14.2 13.7 0.31 0.41 0.50 0.63 0.75 0.26 0.35 0.46 0.57 0.69 0.84 0.28 0.38 0.50 0.64 0.79 0.31 0.43 0.57 17.4 22.6 26.6 32.0 37.1 14.0 18.2 23.4 28.0 32.6 38.6 14.2 18.9 23.8 29.2 34.8 14.8 19.7 25.2 SHF 56.3 54.6 52.8 51.0 49.3 54.6 52.8 51.0 49.3 47.5 45.8 51.0 49.3 47.5 45.8 44.0 47.5 45.8 44.0 Q kW SHC kW 13.7 13.5 13.3 13.1 12.8 13.5 13.3 13.1 12.8 12.6 12.4 13.1 12.8 12.6 12.4 12.2 12.6 12.4 12.2 T/I kW 0.0 Factor for Various Air Flow Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 15 DB˚C WB˚C INDOOR PEH-15MYA-EU (Use for low ambient cooling parts) Cooling Capacity (Standard Air Flow) ) - 33 - 73.8 71.8 69.4 67.2 67.2 73.8 71.8 69.4 67.2 67.2 62.4 71.8 69.4 67.2 67.2 62.4 60.4 67.2 67.2 62.4 60.4 58.2 56.2 62.4 60.4 58.2 56.2 54.0 58.2 56.2 54.0 Q kW COOLING CAPACITY TOTAL INPUT SHC AIR VOLUME 160 2,660 0.976 0.991 0.963 CMM L/S Factor for Various Air Flow PE-20MYC-EU 30.4 35.4 41.4 47.9 53.5 20.5 26.4 31.3 38.3 43.2 50.1 16.2 20.8 27.4 32.5 39.3 45.3 15.9 21.2 27.9 33.6 39.0 47.1 17.1 22.8 28.9 35.7 42.3 17.6 23.6 30.1 SHCkW 25.0 0.41 0.49 0.60 0.71 0.80 0.28 0.37 0.45 0.57 0.64 0.80 0.23 0.30 0.41 0.48 0.63 0.75 0.24 0.32 0.45 0.56 0.67 0.84 0.27 0.38 0.50 0.63 0.78 0.30 0.42 0.56 SHF 3,000 1.0 1.0 1.0 180 SHC:SENSIBLE HEAT CAPACITY 19.4 0.41 31.1 76.0 24 18.7 0.71 48.8 69.2 21 19.2 18.5 0.79 54.5 69.2 20 0.49 19.4 0.28 21.0 76.0 24 36.2 19.2 0.36 26.8 73.8 23 73.8 19.0 0.45 31.9 71.6 22 23 18.7 0.56 38.8 69.2 21 19.0 18.5 0.63 43.9 69.2 20 0.59 18.3 0.79 50.9 64.2 19 42.3 19.2 0.22 16.6 73.8 23 71.6 19.0 0.30 21.2 71.6 22 22 18.7 0.40 27.9 69.2 21 18.3 0.62 18.1 39.8 0.74 18.7 18.5 64.2 19 46.0 0.24 18.5 0.48 62.2 18 16.5 0.32 18.3 18.1 18.1 17.9 18.3 18.1 18.1 17.9 17.7 18.1 17.9 17.7 T/I kW 33.0 69.2 21 21.9 0.44 0.55 0.67 0.83 0.27 0.37 0.49 0.63 0.77 0.30 0.42 0.55 SHF 69.2 69.2 20 28.5 34.3 39.9 47.8 17.4 23.2 29.3 36.2 43.1 18.0 24.1 30.8 SHCkW 20 64.2 60.0 17 19 57.8 16 62.2 64.2 19 18 62.2 57.8 16 18 55.6 15 60.0 60.0 17 17 57.8 55.6 15 16 Q kW WB ˚C 20.0 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR PE-20MYC-EU 71.4 69.2 67.0 64.8 64.8 71.4 69.2 67.0 64.8 64.8 60.2 69.2 67.0 64.8 64.8 60.2 58.2 64.8 64.8 60.2 58.2 56.2 54.2 60.2 58.2 56.2 54.2 52.2 56.2 54.2 52.2 Q kW 3,320 1.025 1.009 1.044 200 T/I:TOTAL INPUT 20.5 20.3 20.1 19.8 19.6 20.5 20.3 20.1 19.8 19.6 19.4 20.3 20.1 19.8 19.6 19.4 19.2 19.8 19.6 19.4 19.2 19.0 18.7 19.4 19.2 19.0 18.7 18.5 19.0 18.7 18.5 T/I kW Cooling Capacity (Standard Air Flow) ( 0.42 0.50 0.61 0.73 0.81 0.28 0.37 0.46 0.58 0.66 0.82 0.23 0.30 0.41 0.49 0.64 0.76 0.24 0.32 0.45 0.56 0.68 0.85 0.28 0.38 0.50 0.64 0.80 0.30 0.42 0.56 SHF 21.8 21.6 21.4 20.9 20.7 21.8 21.6 21.4 20.9 20.7 20.5 21.6 21.4 20.9 20.7 20.5 20.3 20.9 20.7 20.5 20.3 20.1 20.1 20.5 20.3 20.1 20.1 19.8 20.1 20.1 19.8 T/I kW 68.4 66.2 64.0 62.0 62.0 68.4 66.2 64.0 62.0 62.0 57.6 66.2 64.0 62.0 62.0 57.6 55.8 62.0 62.0 57.6 55.8 53.8 52.0 57.6 55.8 53.8 52.0 50.2 53.8 52.0 50.2 Q kW OUTDOOR DB˚C 35.0 29.3 34.0 39.8 46.0 51.2 19.6 25.2 30.1 36.9 41.8 48.6 15.3 19.6 25.8 30.5 37.4 43.5 14.9 20.0 26.3 31.9 37.3 45.1 16.1 21.4 27.1 34.0 40.9 16.3 22.1 28.4 SHCkW 0.43 0.51 0.62 0.74 0.83 0.29 0.38 0.47 0.60 0.67 0.84 0.23 0.31 0.42 0.49 0.65 0.78 0.24 0.32 0.46 0.57 0.69 0.87 0.28 0.38 0.50 0.65 0.81 0.30 0.43 0.57 SHF 23.3 23.1 22.7 22.5 22.2 23.3 23.1 22.7 22.5 22.2 22.0 23.1 22.7 22.5 22.2 22.0 21.8 22.5 22.2 22.0 21.8 21.6 21.4 22.0 21.8 21.6 21.4 21.1 21.6 21.4 21.1 T/I kW 65.0 62.8 60.8 58.8 58.8 65.0 62.8 60.8 58.8 58.8 54.6 62.8 60.8 58.8 58.8 54.6 53.0 58.8 58.8 54.6 53.0 51.2 49.4 54.6 53.0 51.2 49.4 47.8 51.2 49.4 47.8 Q kW 40.0 28.3 33.0 38.9 45.2 50.7 18.8 24.4 29.3 36.0 40.8 47.4 14.7 19.0 25.1 29.9 36.5 42.6 14.3 19.3 25.6 31.2 36.5 44.0 15.4 20.7 26.4 33.0 39.8 15.7 21.3 27.7 SHCkW ) 0.44 0.53 0.64 0.77 0.86 0.29 0.39 0.48 0.61 0.69 0.87 0.23 0.31 0.43 0.51 0.67 0.80 0.24 0.33 0.47 0.59 0.71 0.89 0.28 0.39 0.52 0.67 0.83 0.31 0.43 0.58 SHF In case of “indoor fan external static pressure: ESP = 200Pa”. If you need “ESP = 100Pa”, please subtract “0.9kw” from “T/I value of this table”. 30.0 34.9 40.8 47.1 52.6 20.1 25.9 30.9 37.7 42.7 49.6 15.8 20.3 26.7 31.6 38.4 44.5 15.4 20.7 27.2 32.8 38.3 46.2 16.6 22.1 28.1 34.9 41.7 17.0 22.9 29.4 SHCkW 30.0 25.1 24.9 24.4 24.2 24.0 25.1 24.9 24.4 24.2 24.0 23.8 24.9 24.4 24.2 24.0 23.8 23.5 24.2 24.0 23.8 23.5 23.3 23.1 23.8 23.5 23.3 23.1 22.9 23.3 23.1 22.9 T/I kW 46.0 SHF 26.2 26.4 26.8 27.0 25.7 26.2 0.49 0.40 0.29 0.89 0.79 28.3 23.3 17.9 49.4 43.9 57.2 59.0 61.0 55.2 55.2 27.0 25.7 0.63 34.8 55.2 26.8 25.5 0.71 39.4 55.2 0.44 26.8 0.89 45.9 51.4 27.0 26.4 0.24 14.0 59.0 61.0 26.2 0.32 18.2 57.2 26.4 25.7 0.44 24.2 55.2 0.54 25.5 0.52 28.9 55.2 31.8 25.3 0.69 35.4 51.4 59.0 26.2 0.83 41.2 49.8 0.66 25.7 0.25 13.5 55.2 37.6 25.5 0.33 18.5 55.2 57.2 25.3 0.48 24.7 25.1 24.9 25.5 25.3 25.1 24.9 24.6 25.1 24.9 24.6 T/I kW 51.4 0.73 0.92 0.28 0.40 0.53 0.68 0.85 0.31 0.44 0.59 0.61 35.3 42.7 14.6 19.8 25.4 31.8 38.4 14.9 20.5 26.6 SHCkW 30.2 49.8 48.2 46.6 51.4 49.8 48.2 46.6 45.0 48.2 46.6 45.0 Q kW - 34 - 60.0 17 58.2 17.9 19.0 0.75 45.3 60.4 17.9 0.74 46.0 62.2 18 19.2 19.4 19.7 19.9 20.1 20.3 19.4 19.7 0.64 0.57 0.45 0.37 0.28 0.80 0.71 43.2 38.3 31.3 20.5 53.5 47.9 67.2 67.2 69.4 71.8 73.8 67.2 67.2 18.1 18.4 18.6 18.8 19.0 19.2 18.4 18.6 0.63 0.56 0.45 0.36 0.28 0.79 0.71 43.9 38.8 31.9 26.8 21.0 54.5 48.8 69.2 69.2 71.6 73.8 76.0 69.2 69.2 21 22 23 24 20 21 19.0 19.2 0.49 0.41 36.2 31.1 73.8 76.0 23 24 20.1 20.3 0.49 0.41 35.4 30.4 71.8 73.8 COOLING PEH-20MYA-EU CAPACITY TOTAL INPUT SHC AIR VOLUME 160 2,660 0.976 0.991 0.963 CMM L/S Factor for Various Air Flow 180 3,000 1.0 1.0 1.0 20.5 20.7 21.2 0.49 0.41 0.30 31.6 26.7 20.3 64.8 64.8 21.4 21.6 0.50 0.42 34.9 30.0 69.2 71.4 200 3,320 1.025 1.009 1.044 35.0 21.4 21.6 21.8 22.0 0.69 0.57 0.46 0.32 37.3 31.9 26.3 20.0 53.8 55.8 57.6 22.5 22.9 23.1 0.62 0.51 0.43 39.8 34.0 29.3 66.2 68.4 22.2 0.74 46.0 62.0 64.0 22.0 0.83 51.2 22.9 0.38 25.2 66.2 62.0 22.5 0.47 30.1 64.0 23.1 22.2 0.60 36.9 62.0 0.29 22.0 0.67 41.8 62.0 19.6 21.8 0.84 48.6 57.6 68.4 22.9 22.5 0.31 19.6 64.0 0.23 22.2 0.42 25.8 62.0 15.3 22.0 0.49 30.5 62.0 66.2 21.8 0.65 37.4 21.6 0.78 43.5 55.8 57.6 22.2 0.24 14.9 62.0 62.0 21.2 0.87 21.8 21.6 21.4 21.2 21.0 21.4 21.2 21.0 T/I kW 0.28 0.38 0.50 0.65 0.81 0.30 0.43 0.57 SHF 45.1 16.1 21.4 27.1 34.0 40.9 16.3 22.1 28.4 SHCkW 52.0 57.6 55.8 53.8 52.0 50.2 53.8 52.0 50.2 Q kW 40.0 24.2 24.6 24.8 0.64 0.53 0.44 38.9 33.0 28.3 62.8 65.0 24.0 0.77 45.2 58.8 60.8 23.8 0.86 50.7 0.39 24.4 62.8 58.8 24.6 0.48 29.3 60.8 24.8 24.2 0.61 36.0 58.8 0.29 24.0 0.69 40.8 58.8 18.8 23.5 23.8 0.87 47.4 54.6 65.0 24.6 24.2 0.31 19.0 60.8 0.23 24.0 0.43 25.1 58.8 14.7 23.8 0.51 29.9 58.8 62.8 23.5 0.67 36.5 54.6 23.3 0.80 42.6 23.8 0.33 19.3 58.8 53.0 23.5 0.47 25.6 54.6 24.0 23.3 0.59 31.2 53.0 0.24 23.1 0.71 36.5 51.2 14.3 22.9 0.89 44.0 49.4 58.8 23.5 23.3 23.1 22.9 22.7 23.1 22.9 22.7 T/I kW 0.28 0.39 0.52 0.67 0.83 0.31 0.43 0.58 SHF 15.4 20.7 26.4 33.0 39.8 15.7 21.3 27.7 SHCkW 54.6 53.0 51.2 49.4 47.8 51.2 49.4 47.8 Q kW case of “indoor fan external static pressure: ESP = 200Pa”. ( InIf you need “ESP = 100Pa”, please subtract “1.0kw” from “T/I value of this table”. ) 21.2 0.61 40.8 20.7 0.73 47.1 64.8 67.0 20.5 0.81 52.6 21.4 0.37 25.9 69.2 64.8 21.2 0.46 30.9 67.0 21.6 20.7 0.58 37.7 64.8 0.28 20.5 0.66 42.7 64.8 20.1 20.3 0.82 49.6 60.2 71.4 21.4 0.23 15.8 69.2 67.0 20.3 0.64 38.4 20.1 0.76 44.5 58.2 60.2 20.7 0.24 15.4 20.5 64.8 0.32 20.3 0.45 27.2 60.2 20.7 20.1 0.56 32.8 58.2 64.8 19.9 0.68 38.3 56.2 20.3 20.1 19.9 19.9 19.7 19.9 19.9 19.7 T/I kW 19.9 0.28 0.38 0.50 0.64 0.80 0.30 0.42 0.56 SHF OUTDOOR DB˚C 0.85 16.6 22.1 28.1 34.9 41.7 17.0 22.9 29.4 SHCkW 30.0 46.2 54.2 60.2 58.2 56.2 54.2 52.2 56.2 54.2 52.2 Q kW T/I:TOTAL INPUT 19.9 0.60 41.4 69.4 26.4 SHC:SENSIBLE HEAT CAPACITY 18.8 0.59 42.3 71.6 22 20 0.80 50.1 62.4 0.79 50.9 64.2 19 20.1 0.23 16.2 71.8 19.0 19.9 0.22 0.30 16.6 73.8 23 20.8 69.4 18.8 0.30 21.2 71.6 22 19.7 0.41 27.4 67.2 18.6 0.40 27.9 69.2 21 19.4 0.48 32.5 67.2 18.4 0.48 33.0 69.2 20 19.2 0.63 39.3 18.1 0.62 39.8 64.2 62.4 19 19.7 0.24 15.9 67.2 18.6 0.24 16.5 19.4 69.2 0.32 21 21.2 67.2 18.4 0.32 21.9 69.2 20 19.2 0.45 27.9 62.4 18.1 0.44 19.0 0.56 33.6 60.4 28.5 18.8 18.6 19.2 19.0 18.8 18.6 18.4 18.8 18.6 18.4 T/I kW 0.67 0.84 0.27 0.38 0.50 0.63 0.78 0.30 0.42 0.56 SHF 39.0 58.2 47.1 17.1 22.8 28.9 35.7 42.3 17.6 23.6 30.1 SHCkW 64.2 17.9 56.2 62.4 18.1 17.7 60.4 58.2 56.2 17.9 17.9 17.7 54.0 56.2 17.7 17.5 54.0 Q kW 17.5 T/I kW 17.9 0.67 0.83 0.27 0.37 0.49 0.63 0.77 0.30 0.42 0.55 SHF 0.55 39.9 47.8 17.4 23.2 29.3 36.2 43.1 18.0 24.1 30.8 SHCkW 25.0 34.3 19 57.8 16 62.2 64.2 19 18 62.2 57.8 16 18 55.6 15 60.0 60.0 17 17 57.8 55.6 15 16 Q kW WB ˚C 20.0 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 DB ˚C INDOOR INDOOR PEH-20MYA-EU Cooling Capacity (Standard Air Flow) 61.0 59.0 57.2 55.2 55.2 61.0 59.0 57.2 55.2 55.2 51.4 59.0 57.2 55.2 55.2 51.4 49.8 55.2 55.2 51.4 49.8 48.2 46.6 51.4 49.8 48.2 46.6 45.0 48.2 46.6 45.0 Q kW 46.0 27.0 31.8 37.6 43.9 49.4 17.9 23.3 28.3 34.8 39.4 45.9 14.0 18.2 24.2 28.9 35.4 41.2 13.5 18.5 24.7 30.2 35.3 42.7 14.6 19.8 25.4 31.8 38.4 14.9 20.5 26.6 SHCkW SHF 0.44 0.54 0.66 0.79 0.89 0.29 0.40 0.49 0.63 0.71 0.89 0.24 0.32 0.44 0.52 0.69 0.83 0.25 0.33 0.48 0.61 0.73 0.92 0.28 0.40 0.53 0.68 0.85 0.31 0.44 0.59 26.8 26.6 26.1 25.9 25.5 26.8 26.6 26.1 25.9 25.5 25.3 26.6 26.1 25.9 25.5 25.3 25.1 25.9 25.5 25.3 25.1 24.8 24.6 25.3 25.1 24.8 24.6 24.4 24.8 24.6 24.4 T/I kW - 35 - 17.2 17.4 17.6 17.6 17.8 17.2 17.4 0.62 0.52 0.42 0.34 0.27 0.77 0.66 45.3 39.8 33.1 27.6 22.1 56.4 50.5 73.4 76.2 79.0 81.8 82.0 73.4 76.2 20 21 22 23 24 20 21 81.2 81.6 78.8 76.0 73.2 81.2 81.6 78.8 76.0 73.2 70.4 81.6 78.8 76.0 73.2 70.4 67.6 76.0 73.2 70.4 67.6 64.8 62.0 70.4 67.6 64.8 62.0 59.2 64.8 62.0 59.2 32.2 37.4 44.0 50.3 56.2 21.9 27.5 33.0 39.7 45.2 52.5 17.2 22.0 28.6 33.8 40.8 47.4 17.5 23.0 29.7 35.5 41.4 49.2 17.9 23.8 30.1 37.1 44.4 18.6 24.9 31.9 Q kW SHC kW 0.0 T/I kW 17.7 18.0 18.2 17.7 18.0 18.2 18.5 18.5 18.0 18.2 18.5 18.5 18.7 18.9 18.5 18.5 18.7 18.9 19.2 19.4 18.5 18.7 18.9 19.2 19.4 19.4 18.7 18.9 19.2 19.4 19.4 SHF 0.54 0.40 0.29 0.75 0.60 0.46 0.35 0.25 0.79 0.64 0.53 0.42 0.31 0.23 0.70 0.58 0.46 0.38 0.28 0.21 0.75 0.62 0.52 0.42 0.34 0.27 0.77 0.66 0.56 0.46 0.40 AIR VOLUME CAPACITY TOTAL INPUT SHC PEH-20MYA-EU COOLING 160 2,660 0.976 0.991 0.963 CMM L/S Factor for Various Air Flow 3,000 1.0 1.0 1.0 180 5.0 32.1 37.2 43.7 50.1 55.9 21.8 27.4 32.8 39.5 45.0 52.3 17.1 21.9 28.5 33.7 40.6 47.2 17.4 22.9 29.5 35.4 41.2 49.0 17.8 23.7 30.0 36.9 44.2 18.6 24.8 31.7 19.7 19.2 19.4 19.7 20.0 20.2 19.4 19.7 20.0 20.2 20.2 20.5 20.0 20.2 20.2 20.5 20.7 21.0 20.2 20.2 20.5 20.7 21.0 21.3 20.2 20.5 20.7 21.0 21.3 0.29 0.75 0.60 0.47 0.35 0.25 0.80 0.64 0.53 0.42 0.31 0.23 0.70 0.58 0.46 0.38 0.28 0.21 0.75 0.62 0.52 0.42 0.34 0.27 0.77 0.66 0.56 0.46 0.40 200 79.0 80.4 77.6 74.8 72.0 79.0 80.4 77.6 74.8 72.0 69.2 80.4 77.6 74.8 72.0 69.2 66.4 74.8 72.0 69.2 66.4 63.6 60.8 69.2 66.4 63.6 60.8 58.0 63.6 60.8 58.0 31.7 36.9 43.3 49.6 55.4 21.5 27.2 32.5 39.3 44.6 51.8 16.9 21.7 28.3 33.4 40.4 46.8 17.1 22.5 29.2 35.0 40.8 48.6 17.7 23.5 29.7 36.7 43.8 18.4 24.6 31.4 Q kW SHCkW T/I kW 18.5 18.7 19.0 18.5 18.7 19.0 19.2 19.5 18.7 19.0 19.2 19.5 19.7 19.7 19.2 19.5 19.7 19.7 19.9 20.2 19.5 19.7 19.7 19.9 20.2 20.4 19.7 19.7 19.9 20.2 20.4 SHF 0.54 0.40 0.29 0.76 0.60 0.47 0.35 0.26 0.80 0.64 0.53 0.42 0.31 0.23 0.70 0.58 0.46 0.38 0.28 0.21 0.75 0.62 0.53 0.42 0.34 0.27 0.77 0.66 0.56 0.46 0.40 10.0 ) 16 17 21 22 17.1 17.1 16.8 17.1 17.1 17.3 17.5 17.1 17.1 17.3 17.5 17.7 17.9 17.3 17.5 17.7 17.9 18.1 18.4 17.5 17.7 17.9 18.1 18.4 18.4 17.7 17.9 18.1 18.4 18.4 0.41 0.29 0.76 0.61 0.47 0.36 0.26 0.81 0.65 0.53 0.42 0.31 0.23 0.71 0.59 0.47 0.39 0.29 0.22 0.76 0.63 0.54 0.43 0.36 0.27 0.78 0.68 0.58 0.48 0.40 24.3 18.2 43.4 36.4 29.5 23.3 17.5 48.2 40.3 34.6 28.8 22.2 16.8 46.4 40.1 33.2 28.1 21.4 16.7 51.4 44.3 39.0 32.2 27.0 21.3 54.9 49.2 42.8 36.5 31.4 59.8 62.5 57.0 59.8 62.5 65.3 68.0 59.8 62.5 65.3 68.0 70.8 72.5 65.3 68.0 70.8 72.5 74.2 75.9 68.0 70.8 72.5 74.2 75.9 77.6 70.8 72.5 74.2 75.9 77.6 54.4 54.8 55.2 55.4 55.6 55.8 56.0 56.2 56.2 56.6 56.8 57.0 57.2 17.6 17.4 17.4 17.2 17.0 16.8 16.8 16.6 16.4 16.1 16.1 15.7 15.9 14.1 13.9 13.9 13.7 13.7 13.5 13.5 13.5 13.2 13.2 13.0 13.0 13.0 62.2 62.8 63.2 63.4 63.6 64.0 64.2 64.4 64.6 65.0 65.2 65.4 65.6 19.9 19.7 19.5 19.3 19.0 18.8 18.8 18.6 18.4 18.2 18.0 17.6 17.8 T/I kW 10.0 OUTDOOR WB ˚C 40.6 40.8 41.0 41.2 41.4 41.6 41.8 42.0 42.2 42.4 42.6 42.6 42.8 PEH-20MYA-EU HEATING 15.7 15.5 15.5 15.3 15.1 15.1 14.9 14.7 14.7 14.5 14.5 14.3 14.3 T/I kW 0.0 70.8 71.2 71.8 72.2 72.4 72.8 73.2 73.6 73.8 74.0 74.2 74.4 74.6 Q kW 22.4 22.1 21.7 21.5 21.3 21.3 21.1 20.9 20.7 20.5 20.1 19.7 19.9 T/I kW 15.0 47.2 47.4 47.8 48.0 48.2 48.4 48.6 48.6 48.8 49.0 49.2 49.0 49.6 Q kW L/S CMM CAPACITY TOTAL INPUT AIR VOLUME 0.989 1.025 2,660 160 1.0 1.0 3,000 180 Factor for Various Air Flow ( 12.6 12.6 12.4 12.4 12.4 12.4 12.2 12.2 12.2 12.2 12.0 12.0 12.0 Q kW T/I kW Q kW 5.0 34.6 34.8 35.0 35.2 35.4 35.6 35.8 36.0 36.2 36.4 36.4 36.6 36.8 T/I kW -5.0 OUTDOOR WB ˚C Q kW T/I kW Q kW -10.0 1.008 0.984 3,320 200 * Q:HEATING CAPACITY T/I:TOTAL INPUT In case of “indoor fan external static pressure: ESP = 200Pa”. If you need “ESP = 100Pa”, please subtract “1.0kw” from “T/I value of this table”. 27 26 25 24 23 22 21 20 19 18 17 16 15 DB ˚C INDOOR 27 26 25 24 23 20 19 18 15 16.8 0.55 31.1 DB ˚C T/I kW SHF INDOOR PEH-20MYA-EU Heating Capacity (Standard Air Flow) 57.0 Q kW SHCkW 15.0 In case of “indoor fan external static pressure: ESP = 200Pa”. If you need “ESP = 100Pa”, please subtract “1.0kw” from “T/I value of this table”. 19.4 0.40 ( 19.2 0.54 T/I:TOTAL INPUT 80.2 81.2 78.4 75.6 72.8 80.2 81.2 78.4 75.6 72.8 70.0 81.2 78.4 75.6 72.8 70.0 67.2 75.6 72.8 70.0 67.2 64.4 61.6 70.0 67.2 64.4 61.6 58.8 64.4 61.6 58.8 T/I kW SHF OUTDOOR DB˚C Q kW SHCkW 3,320 1.025 1.009 1.044 SHC:SENSIBLE HEAT CAPACITY 17.8 17.0 0.75 52.7 70.6 19 0.40 17.6 0.21 17.3 81.8 23 32.4 17.6 0.28 22.1 79.0 22 82.0 17.4 0.38 28.7 76.2 21 24 17.2 0.46 33.9 73.4 20 17.6 17.0 0.58 40.9 70.6 19 0.46 17.0 0.70 47.5 67.8 18 37.6 17.4 0.23 17.6 76.2 21 81.8 17.2 0.32 23.2 73.4 20 23 17.0 0.42 29.8 70.6 19 17.6 17.0 0.53 35.7 67.8 18 0.56 16.7 0.64 41.6 65.0 17 44.2 16.5 0.79 49.4 62.2 16 79.0 17.0 0.26 18.0 70.6 19 22 17.0 0.35 23.9 67.8 16.5 0.60 18 16.3 0.75 16.7 37.2 16.7 0.29 0.46 62.2 16 44.6 16.5 0.40 30.2 59.4 15 18.7 16.3 0.54 65.0 65.0 17 25.0 32.0 T/I kW SHF 17 62.2 16 59.4 Q kW SHCkW -5.0 Note1. * Q:COOLING CAPACITY 30 28 26 24 22 20 15 DB˚C WB˚C INDOOR PEH-20MYA-EU (Use for low ambient cooling parts) Cooling Capacity (Standard Air Flow) ) CAPACITY REDUCTION RATIO DUE TO CHANGES IN PIPING LENGTH (1) Cooling capacity PE-7,8,15MYC-EU PEH-7,8,15MYA-EU Capacity ratio 1.0 0.9 0 5 10 15 20 25 30 35 40 45 50 40 45 50 Equivalent piping length (m) PE-10,20MYC-EU PEH-10,20MYA-EU Capacity ratio 1.0 0.9 0 5 10 15 20 25 30 35 Equivalent piping length (m) (2) Heating capacity Model name Equivalent piping length PEH-7, 8, 10, 15, 20MYA - 36 - ~30m 30~50m 1.0 0.995 OPERATION RANGE The range of working temperatures is as below. Make sure which unit you are using and confirm the range of application. Cooling Heating (PEH only) 40 30 Range for continuous operation 20 10 0 -5 -10 10 15 20 24 25 30 Indoor temp.(˚CWB) Range for continuous operation Use for low ambient cooling parts (without PU-15,20) Outdoor temp.(˚CWB) Outdoor temp.(˚CDB) 50 46 15 10 5 Range for continuous operation 0 -5 -10 10 15 Note: As an applicable humidity outside standard for both indoors and outdoors, and indoor return air we recommend use within a range of 35-80% relative humidity. However, it is a condition that there is no be dewy in surfaces of electric parts. - 37 - 20 25 27 30 Indoor temp.(˚CDB) Caution: The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. FAN PERFORMANCE PE-7MYC-EU PEH-7MYA-EU PEH-5MYA-EU Fan Performance Curve 50Hz (Pa) 450 450 Recommended Range 400 400 Fan speed (rpm) 350 Recommended Range Fan speed (rpm) 1400 350 1300 1300 300 1200 Total static pressure Total static pressure Fan Performance Curve 50Hz (Pa) For connection operation line 250 1100 200 1000 150 900 For connection operation line For Hi speed operation line 300 1200 250 200 150 1100 For Low speed operation line 1000 900 800 100 Inte r 100 SP nal Inte 50 0 35 580 40 45 750 50 55 (CMM) 920 (L/S) 48 50 800 Air flow factory pre setting ESP = 125Pa 450 (Pa) Fan speed (rpm) 1400 400 For connection operation line 350 Total static pressure Total static pressure 300 1200 150 1100 For connection operation line 900 800 100 r na Fan Performance Curve 50Hz Fan speed (rpm) 1400 For connection operation line 1300 300 1200 250 200 150 Inte 70 Recommended Range 1300 1000 65 450 Recommended Range 350 200 60 1000 PE-10MYC-EU PEH-10MYA-EU Fan Performance Curve 50Hz (Pa) 55 Air flow factory pre setting ESP = 125Pa PE-8MYC-EU PEH-8MYA-EU 250 l SP 50 0 400 r na 1100 For connection 1000 operation line al 900 SP n er t l SP In 100 50 50 0 0 50 830 55 60 1000 65 70 1170 75 80 (CMM) 1330 (L/S) Air flow factory pre setting ESP = 125Pa 65 70 1080 80 1330 90 100 (CMM) 1670 (L/S) Air flow factory pre setting ESP = 125Pa - 38 - 75 (CMM) 1250 (L/S) PE-15MYC1-EU PEH-15MYA-EU Total static pressure (Pa) 200 Fan Performance Curve 50Hz Recommended Range (Pa) 1000 300 Fan speed (rpm) 1300 Total static pressure 800 600 3.7kW 400 L/S FAN SPEED rpm PULLEYSIZE (MOTOR SIDE) mm inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm 1100 PULLEYSIZE mm (MOTOR SIDE) inch 1000 2.2kW 900 800 200 CMM 1200 500 400 Model 600 700 600 500 l SP a Intern 700 0 110 1830 120 130 2170 140 150 2500 160 170 (CMM) 2830(L/S) 800 Air flow factory pre setting ESP = 200Pa PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw 110 1830 768 139.7 5.5 254 10 B45 2.2 898 114.3 4.5 177.8 7 B38X2 2.2 942 152.4 6 228.6 9 B44 2.2 1008 127 5 177.8 7 B37X2 3.7 1119 139.7 5.5 177.8 7 B38X2 3.7 1190 127 5 152.4 6 B36X2 3.7 1258 177.8 7 203.2 8 B42 3.7 Airflow PE-15MYC1-EU, PEH-15MYA-EU 140 120 130 150 2330 2000 2170 2500 768 768 768 768 139.7 139.7 139.7 139.7 5.5 5.5 5.5 5.5 254 254 254 254 10 10 10 10 B45 B45 B45 B45 2.2 2.2 2.2 2.2 898 898 898 898 114.3 114.3 114.3 114.3 4.5 4.5 4.5 4.5 177.8 177.8 177.8 177.8 7 7 7 7 B38X2 B38X2 B38X2 B38X2 2.2 2.2 2.2 2.2 942 942 971 942 152.4 152.4 139.7 152.4 6 6 5.5 6 228.6 228.6 203.2 228.6 9 9 8 9 B44 B44 B40X2 B44 2.2 2.2 3.7 2.2 1008 1008 1067 1008 127 127 152.4 127 5 5 6 5 177.8 177.8 203.2 177.8 7 7 8 7 B37X2 B37X2 B37X2 B40X2 3.7 3.7 3.7 3.7 1119 1119 1119 1119 139.7 139.7 139.7 139.7 5.5 5.5 5.5 5.5 177.8 177.8 177.8 177.8 7 7 7 7 B38X2 B38X2 B38X2 B38X2 3.7 3.7 3.7 3.7 1190 1190 1190 127 127 127 5 5 5 152.4 152.4 152.4 6 6 6 B36X2 B36X2 B36X2 3.7 3.7 3.7 - 160 2670 898 114.3 4.5 177.8 7 B38X2 2.2 971 139.7 5.5 203.2 8 B40X2 3.7 1067 152.4 6 203.2 8 B40X2 3.7 1119 139.7 5.5 177.8 7 B38X2 3.7 - Std. PE-20MYC-EU PEH-20MYA-EU Total static pressure (Pa) 200 Fan Performance Curve (Pa) Recommended Range 1000 Fan speed (rpm) 300 1300 5.5 Total static pressure 800 kW 1200 400 600 1100 1000 400 500 3.7kW 900 800 700 200 600 P rnal S Inte 600 700 0 150 160 2500 180 3000 195200 3300 220 240 (CMM) 4000(L/S) Air flow factory pre setting ESP = 200Pa 800 Model CMM L/S FAN SPEED rpm PULLEYSIZE (MOTOR SIDE) mm inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw FAN SPEED rpm PULLEYSIZE mm (MOTOR SIDE) inch PULLEYSIZE mm (FAN SIDE) inch BELT SIZE inch MOTOR kw Std. - 39 - mm (FAN SIDE) 150 2500 627 127 5 279.4 11 B44X2 3.7 768 139.7 5.5 254 10 B43X2 3.7 942 152.4 6 228.6 9 B42X2 3.7 1008 127 5 177.8 7 B37X2 3.7 1119 139.7 5.5 177.8 7 B37X2 5.5 1229 152.4 6 177.8 7 B38X2 5.5 1258 177.8 7 203.2 8 B41X2 5.5 Airflow PE-20MYC-EU, PEH-20MYA-EU 200 160 180 220 3330 2670 3000 3670 692 627 692 127 127 127 5 5 5 254 279.4 254 11 10 10 B44X2 B42X2 B42X2 3.7 3.7 3.7 768 773 773 773 139.7 127 127 127 5.5 5 5 5 254 228.6 228.6 228.6 10 9 9 9 B43X2 B40X2 B40X2 B40X2 3.7 3.7 3.7 3.7 942 942 942 942 152.4 152.4 152.4 152.4 6 6 6 6 228.6 228.6 228.6 228.6 9 9 9 9 B42X2 B42X2 B42X2 B41X2 3.7 3.7 5.5 3.7 1008 1008 1067 1067 127 127 152.4 152.4 5 5 6 6 177.8 177.8 203.2 203.2 7 7 8 8 B37X2 B37X2 B39X2 B39X2 3.7 3.7 5.5 5.5 1119 1119 1119 1119 139.7 139.7 139.7 139.7 5.5 5.5 5.5 5.5 177.8 177.8 177.8 177.8 7 7 7 7 B37X2 B37X2 B37X2 B37X2 5.5 5.5 5.5 5.5 1229 1229 1229 152.4 152.4 152.4 6 6 6 177.8 177.8 177.8 7 7 7 B38X2 B38X2 B38X2 5.5 5.5 5.5 1258 1258 177.8 177.8 7 7 203.2 203.2 8 8 B41X2 B41X2 5.5 5.5 - 240 4000 773 127 5 228.6 9 B40X2 3.7 942 152.4 6 228.6 9 B41X2 5.5 1067 152.4 6 203.2 8 B39X2 5.5 - 170 2830 898 114.3 4.5 177.8 7 B38X2 2.2 971 139.7 5.5 203.2 8 B40X2 3.7 1067 152.4 6 203.2 8 B40X2 3.7 1119 139.7 5.5 177.8 7 B38X2 3.7 - Pulley outside dimensions are shown below: (Unit : mm) (1) Shape of belt groove e f K0 Shape of V-belt Nominal Dia. øP.C B Over 125 Under 160 Over 160 Under 200 Over 200 a (˚) W 34 15.86 36 16.07 38 16.29 øP.C r3 r1 a r2 r2 K w L0 L0 K K0 e f r1 r2 r3 V-belt thickness (Reference) 12.5 5.5 9.5 19.0 12.5 0.2~0.5 0.5~1.0 1~2 11 Sectional plan of V-belt 11.0mm 16.5mm 40˚ B type (2) Shape of motor pulley boss (Unit : mm) C B A MOTOR CAPACITY (kW) A +0.028 2.2, 3.7 28 + 0.007 5.5 38 + 0.007 +0.028 B + 0.128 31 + 0.007 + 0.128 41 + 0.009 - 40 - C 8 +0.018 -0.018 +0.018 10 -0.018 SOUND DATA Indoor units Sound Levels MODEL PEH-5MYA-EU PE-7MYC-EU PEH-7MYA-EU PE-8MYC-EU PEH-8MYA-EU PE-10MYC-EU PEH-10MYA-EU PE-15MYC1-EU PEH-15MYA-EU PE-20MYC-EU PEH-20MYA-EU OCTAVE BAND FREQ. Hz SPL dB(A) 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 55 60.5 57.5 57.5 52.5 50.5 43 34.5 28.5 55 62 60 54 53 50 42.5 37 31.5 56 63 61 55 54 51 43.5 38 32.5 59 62 62.5 58.5 59.5 53 48 43.5 36 61 25 40 47 52 55 57.5 52 36.5 62 32 44 49 53.5 56.5 57.5 53 51 Outdoor units Sound Levels OCTAVE BAND FREQ. Hz SPL dB(A) 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz PUH-5MYE1-EU 57 68 58 57 52.5 52 47.5 49 40 PU-7MYC1-EU PUH-7MYC2-EU PU-8MYC1-EU PUH-8MYC2-EU 65 62 63.5 62 62 60 57.5 54 54 65 62 63.5 62 62 60 57.5 54 54 PUH-8MYE1-EU PU-10MYC1-EU PUH-10MYC2-EU 65 45.4 58 58 58.5 61 60 51.5 47 65 64.5 65 64 62.5 60 57 54.5 53 PUH-10MYE1-EU 65 45.4 58 58 58.5 61 60 51.5 47 PU-15MYC1-EU 67 68 72 70 65 60 57 53 49.5 PU-20MYC1-EU 68 66 69 70.5 65 62 59 56.5 53 PUH-15MYC2-EU 69 43 51 59 64 65 64 55 50.5 PUH-20MYC2-EU 69 43 51 59 64.5 65 64 55.5 51.5 MODEL Position measurement Indoor unit Outdoor unit PE(H) PU(H) 1m Inlet Outlet 1m 1m - 41 - Service panel side APPROXIMATION FOR SOUND POWER LEVEL AT SUPPLY DUCT FLANGE OF UNIT Air volume 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz <CMM> External static pressure <Pa> PE(H)-7 60 125 77.2 74.7 71.6 69.9 65.7 61.4 PE(H)-8 70 125 79.4 76.9 73.9 72.4 68.4 64.3 PE(H)-10 90 125 81.2 78.7 75.7 74.3 70.4 66.5 PE(H)-15 140 200 83.4 80.9 78.0 76.6 72.7 68.9 PE(H)-20 180 200 84.5 82.1 79.1 77.7 73.8 70.1 MODEL Note: This is very rough calculation, Noise level will be changed by operation condition or installation. - 42 - OUTLINE DIMENSIONS (unit; mm) PEH-5 POWER SUPPLY CABLE ENTRY ø27 (Bottom side) 104 130 130 130 130 130 66 HOLES:18-ø3.1 AIR INLET DUCT FLANGE 40 55 50 105 960 20 200 40 199 40 OPTIONAL PARTS CABLE ENTRY ø27 (Bottom side) 34 782 135 66 CONTROL CABLE ENTRY ø27 (Bottom side) *Except: Drain size (unit; inch) 20 131 CONTROL BOX 55 AIR OUTLET DUCT FLANGE 130 130 130 55 15 HOLES:14-ø3.1 HOLES:4-ø12 1095 650 50 40 920 15 210 210 98 250 428 REFRIGERANT PIPE ø12.7 (1/2) Braze 14 AIR OUTLET 25 382 280 100 100 130 130 42 33 40 500 REFRIGERANT PIPE ø19.05 (3/4) Braze 25 70 42 20 156 344 70 15 95 152 AIR INLET 1000 530 944 562 DRAIN:RC1 PE(H)-7,8 104 POWER SUPPLY CABLE ENTRY 27 (Bottom side) 1102 130 130 130 130 34 130 130 130 HOLES:24- 3.1 31 130 105 40 199 1280 20 20 200 (Bottom side) AIR INLET DUCT FLANGE 50 55 OPTIONAL PARTS CABLE ENTRY 27 40 27 (Bottom side) 40 CONTROL CABLE ENTRY 135 31 HOLES:22- 3.1 45 AIR OUTLET DUCT FLANGE REFRIGERANT PIPE 25.4 (1) Braze 25 130 130 130 45 HOLES:4- 12 1000 40 120 250 REFRIGERANT PIPE 15.88 (5/8) Braze 382 100 100 25 1240 120 AIR OUTLET 14 70 280 42 130 98 40 15 130 130 156 344 33 130 1320 70 42 20 15 95 152 428 AIR INLET 530 130 1415 650 50 130 15 131 CONTROL BOX 562 1264 DRAIN:Rc1 - 43 - PE(H)-10 104 POWER SUPPLY CABLE ENTRY 27 (Bottom side) 1302 66 130 135 130 130 130 34 130 130 130 130 HOLES:26- 3.1 130 66 CONTROL 105 40 (Bottom side) 1480 20 20 200 40 (Bottom side) 199 40 OPTIONAL PARTS CABLE ENTRY 27 AIR INLET DUCT FLANGE 50 27 55 CABLE ENTRY HOLES:22- 3.1 45 130 130 130 AIR OUTLET DUCT FLANGE HOLES:4- 12 25 AIR OUTLET 40 98 220 REFRIGERANT PIPE 15.88 (5/8) Braze 250 382 100 100 280 45 1440 1000 220 REFRIGERANT PIPE 28.6 (1-1/8) Braze 25 70 20 40 42 130 42 130 1520 70 15 130 156 344 1464 33 562 DRAIN:Rc 1 PE(H)-15 70 1690 1418 120 49 1300=130X10 59 AIR INLET DUCT FLANGE 63 50 POWER SUPPLY CABLE ENTRY 27 (BOTTOM SIDE) 3.1 15 HOLES:34- 59 130 55 CONTROL CABLE ENTRY 27 (BOTTOM SIDE) 620 40 40 190 REFRIGERANT PIPE 15.88 (5/8) Braze REFRIGERANT PIPE 25.4 (1) 25 Braze OPTIONAL PARTS REFRIGERANT CABLE ENTRY 27 PIPE 15.88 (5/8) Braze CONTROL BOX REFRIGERANT PIPE 25.4 (1) Braze 130 AIR OUTLET DUCT FLANGE 46 910=130X7 484 VIEW A 12 63 HOLES:4- 15 34 81 25 1637 1002 46 101 HOLES:24- 3.1 865 1587 - 44 - 50 19 23 110 110 600 110 110 130 50 DRAIN: Rc1 110 130 706 130 207 276 A 36 AIR OUTLET 50 15 27 37 36 462 74 91 191 AIR OUTLET 74 AIR INLET 746 87 69 15 26 428 95 152 AIR INLET 15 130 14 530 130 1615 650 50 130 15 131 CONTROL BOX AIR INLET PE(H)-20 70 1993 1648 193 44 49 1560=130X12 AIR INLET DUCT FLANGE 63 50 POWER SUPPLY CABLE ENTRY 27 (BOTTOM SIDE) 3.1 15 HOLES:38- 44 130 620 40 12 63 HOLES:4- 130 21 1170=130X9 536 81 25 1940 25 CABLE ENTRY 27 REFRIGERANT CONTROL BOX PIPE 15.88 (5/8) Braze REFRIGERANT PIPE 28.6 (1-1/8) Braze AIR OUTLET DUCT FLANGE 15 190 44 40 REFRIGERANT PIPE 15.88 (5/8) Braze REFRIGERANT PIPE 28.6 (1-1/8) Braze OPTIONAL PARTS 55 CONTROL CABLE ENTRY 27 (BOTTOM SIDE) 1212 21 142 HOLES:28- 3.1 865 130 26 1890 50 DRAIN:Rc 1 - 45 - 50 36 207 269.5 A 19 23 110 110 600 110 706 AIR OUTLET 50 15 110 130 167 AIR OUTLET 90 AIR INLET 746 110 37 36 130 90 89.5 462 50 27 69 15 87 VIEW A AIR INLET PUH-5 75 AIR INLET 400 AIR INLET 75 Holes :4-12 × 20 21 1040 550 AIR OUTLET 21 1000 1175 SERVICE PANEL 131 126 REFRIGERANT PIPE ø12.7 (1/2) Flare CABLE ENTRY 21 Hole : ø15 Holes : 2-ø15 75 18 PU(H)-7,8,10 (Upper blow) AIR INLET 275 275 13 400 42 75 42 84 75 REFRIGERANT PIPE ø19.05 (3/4) Flare 200 CABLE ENTRY 25X40 1000 350 13 724 AIR INLET 700 AIR OUTLET Holes: 4-12 × 20 SERVICE PANEL 120 980 AIR INLET 34 28 100 235 175 REFRIGERANT PIPE PU(H)- 7,8:ø25.4(1) Flange PU(H)- 10:ø28.6(1-1/8) Flange 875 REFRIGERANT PIPE ø15.88 (5/8) Flare 72 115 25 160 25 1400 540 700 1450 25 ACCESSORY PIPE - 46 - 25 PUH-8,10 (Side blow) 400 75 AIR INLET Holes : 4-12 × 20 75 AIR INLET 21 1290 21 AIR OUTLET 550 1250 1175 SERVICE PANEL REFRIGERANT PIPE ø15.88(5/8) Flare 130 CABLE ENTRY REFRIGERANT PIPE PUH-8:ø25.4(1) Flange PUH-10:ø28.6(1-1/8) Flange 44 49 Hole : ø15 400 75 56 42 75 42 84 75 Holes : 2-ø15 275 275 ACCESSORY PIPE PU-15 23 AIR INLET 23 1046 AIR INLET AIR INLET AIR OUTLET 998 998 HOLES: 4-Uø15 SERVICE PANEL 1070 REFRIGERANT PIPE ø25.4(1) Flange ACCESSORY PIPE 170 75 85 75 78 No.1 No.2 85 0 169 242 100 CONTROL CABLE ENTRY ø27 50 137 721 995 POWER SUPPLY CABLE ENTRY ø43 - 47 - 137 1230 REFRIGERANT PIPE ø15.88(5/8) Flare PU-20 464 35 AIR INLET AIR INLET 464 AIR INLET No.1 17 35 30 52 48 HOLES: 6-ø15 No.2 2036 17 ACCESSORY PIPE REFRIGERANT PIPE ø15.88(5/8) Flare REFRIGERANT PIPE ø28.6(1-1/8) Flange 1996 160 SERVICE PANEL CONTROL CABLE ENTRY ø27 801 POWER SUPPLY CABLE ENTRY ø47 392 81 85 213 80 961 AIR OUTLET 998 756475 750 130 PUH-15,20 200 Holes : 4-12 × 20 27 830 2005 478.5 27 994 CONTROL BOX REFRIGERANT PIPE ø15.88 (5/8) Flare 1042 1200 SERVICE PANEL REFRIGERANT PIPE PUH-15:ø25.4(1) Flange PUH-20:ø28.6(1-1/8) Flange 1080 26 74 No.1 No.2 195 120 ACCESSORY PIPE 66 911 54 128 1951 2059 - 48 - 54 Note: In the case of installation are shown below, it is possible to use the unit by connecting the duct. However, the pressure loss must be 30Pa (3mmAq) or less. Duct work is local supply. DUCT DUCT - 49 - WIRING DIAGRAMS PE-7MYC-EU /PU-7MYC1-EU (STANDARD) OUTDOOR TB1 L2 RED F3(3.15A) BLUE WHITE BLACK BLACK MC 51F2 RED L1 WHITE RED PE 51F2 17 CIRCUIT BREAKER (FIELD SUPPLY) PU-7MYC1-EU···50A 51C RED WHITE L3 N 52C RED L1 POWER SUPPLY 380~415VAC 3N~PE 50Hz 52C BLACK 49C 18 C14 RED 2 3 WHITE 1 2 3 RED BLACK MF2 (*2) VIOLET TB5 1 16 VIOLET 1 C11 15 BLACK MF3 (*2) C21 15 63H WHITE GRAY 2 19 CZ2 C13 51C 1 22 VIOLET CZ2 CH 14 20 3 30 CZ 21 GRAY 14 CR2 VIOLET 52C 30 CZ TB6 N N (*1) JUMPER INDOOR TB2 L POWER SUPPLY 220~240VAC ~PE 50Hz TB4 51F1 52F RED L TB4 Hi C01 RED 6 6 5 BROWN 2 Low BLUE RED F1 (3.15A) L CIRCUIT BREAKER (FIELD SUPPLY) PE-7MYC-EU···15A RED NOTE 5 C03 C03 C04 1 TB4 GRAY 1 19 PINK GRAY 1 26L 15 3 15 TB3 15 C03 3 3 OUTDOOR 3 TB4 30FZ 18 16 C16 COMP1 FZ 8 CZ1 24VAC(N) AC 24V Tr 52F 21 PAC-204RC 1 RED SILVER PINK 4 1 1 C PINK F2 (3.15A) 51F1 17 BLUE C01 PINK 20 MF1 5 6 FAN HI PE 7 SW2(FIELD SUPPLY) 24VAC(L) N (*2) 1 7 CZ2 3 2 CR1 2 PINK GRAY 14 GRAY 3 52F 30 FZ BLUE Symbol MC MF1 MF2,3 52C 52F TB1~6 CH F1~3 Tr 49C 51C 51F1,2 63H 26L FZ CZ1,2 30CZ,FZ SW1 C C01,03,04,11, 13,14,16,21 CR1,2 Name Compressor motor Fan motor (indoor)(*2) Fan motor (outdoor)(*2) Contactor (compressor) Contactor (fan I/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat (compressor) Over current relay (compressor) Over current relay(fanI/D,O/D) High-pressure switch Thermostat (compressor) Auxiliary relay (fan) Auxiliary relay (compressor) Auxiliary relay (check) Switch (Fan Hi-Low) Run capacitor Connector Surge killer Controller connection. Symbol No. TB4 1 2 3 4 Function Power (Active) Cooling operation Fan operation Power (Neutral) PAC-204RC terminal no. 24VAC(L) COMP1 FAN HI 24VAC (N) BLUE GRAY 14 FZ CZ1 N 4 4 GRAY Note: 1. 2. 3. 4. The dotted lines show field wiring. The figure in the parenthesis show field supply parts. Color of earth wire is yellow and green twisting. Please remove the jumper wire ((*1) Mark) in the left diagram if you use the switch <SW1> at local. If the switch <SW1> is not used, the fan motor (indoor) drives at high speed. 5. In case of power supply 220V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 6. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays <51C>, <51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. This motor (*2) includes auto reset type internal thermostat. - 50 - PE-8,10MYC-EU/PU-8,10MYC1-EU (STANDARD) TB1 OUTDOOR RED L1 L2 POWER SUPPLY 380~415VAC 3N~PE 50Hz RED L3 N 52C WHITE BLACK BLACK F3(3.15A) L1 BLUE WHITE BLACK 51F2 17 VIOLET CIRCUIT BREAKER (FIELD SUPPLY) 52C TB5 18 16 VIOLET C14 15 1 2 19 C13 22 VIOLET CZ2 30 CZ 3 21 TB6 30 CZ RED L2 L3 WHITE 51F1 C01RED 1 2 3 BLACK RED WHITE BLACK MF3 (*1) 14 CR2 52F L1 RED BLUE TB2 INDOOR MF2 (*1) VIOLET 52C N N BLACK GRAY 14 20 CH WHITE CZ2 51C 1 RED 1 2 3 C21 GRAY 15 63H C11 1 2 3 49C PU- 8MYC1-EU···50A PU-10MYC1-EU···60A POWER SUPPLY 380~415VAC 3N~PE 50Hz MC 51F2 RED RED PE 51C RED WHITE F1 (3.15A) L1 WHITE C02 RED MF1 BLUE WHITE 1 BLUE 2 3 RED N TB4 GRAY PE C01 1 4 49F C03 20 17 FZ 3 3 30FZ Controller connection. Symbol No. Function TB4 1 2 3 4 Power (Active) Cooling operation Fan operation Power (Neutral) 3 2 CZ2 GRAY PAC-204RC terminal no. 24VAC(L) COMP1 FAN HI 24VAC (N) GRAY 3 14 52F BLUE GRAY 14 FZ CZ1 Symbol Name Compressor motor MC MF1 Fan motor (indoor) MF2,3 Fan motor (outdoor)(*1) 52C Contactor (compressor) 52F Contactor (fan I/D) TB1~6 Terminal block CH Crankcase heater F1~3 Fuse (3.15A) Tr Transformer 49F Internal thermostat(indoor fan) 49C Internal thermostat(compressor) Over current relay(compressor) 51C Over current relay(fanI/D,O/D) 51F1,2 High-pressure switch 63H 26L Thermostat(freeze pretection) FZ Auxiliary relay (fan) Auxiliary relay (compressor) CZ1,2 Auxiliary relay (check) 30CZ,FZ C01~04,11, Connector 13,14,16,21 Surge killer CR1,2 3 15 OUTDOOR 30 FZ N 15 TB3 15 2 BLUE 1 26L 3 CR1 PINK C16 GRAY PINK TB4 19 18 PAC-204RC AC 24V Tr 5 CZ1 C03 C04 1 SILVER 1 FAN HI RED 8 24VAC(L) 51F1 PINK COMP1 16 52F 1 1 F2 (3.15A) 24VAC(N) CIRCUIT BREAKER (FIELD SUPPLY) PE-8,10MYC-EU···15A NOTE 4 C03 4 4 C01 1 2 3 GRAY Attach the accessory Remove C02 1 2 3 MF1 1 2 3 This circuit diagram shows connections. (If the external static pressure is less than 30 pa, change to connections.) Note: 1. 2. 3. 4. The dotted lines show field wiring. The figure in the parenthesis show field supply parts. Color of earth wire is yellow and green twisting. In case of power supply 380V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 5. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays<51C>, <51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. This motor (*1) includes auto reset type internal thermostat. - 51 - PE-15MYC1-EU/PU-15MYC1-EU (STANDARD) TB1 OUTDOOR L2 L3 CIRCUIT BREAKER (FIELD SUPPLY) PU-15MYC1-EU···100A N 52C1 RED L1 POWER SUPPLY 380~415VAC 3N~PE 50Hz RED WHITE WHITE 52C2 RED 51C2 RED 52F2 RED 51F2 WHITE BLACK BLACK BLACK MC2 L1 RED 51 F2 18 52 C1 52 C2 VIOLET 49C1 19 VIOLET ORANGE C14 17 16 ORANGE C24 1 CH1 2 20 1 1 CH2 25 51C1 23 26 VIOLET 21 30 CZ2-1 CZ1 3 3 22 TB5 N N WHITE BLUE 51F1 MF1 BLACK F1 (3.15A) RED PE L1 F2 (3.15A) NOTE 4 C03 RED 1 C03 SILVER C16 AC 24V FZ 30 FZ 3 19 PAC-204RC 11 2 TB3 2 52 F1 GRAY3 CZ 1-1 BLUE N Name Compressor motor Fan motor (indoor) Fan motor (outdoor)(*1) Contactor (compressor) Contactor (fan I/D) Contactor (fan O/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat(compressor) Over current relay(compressor) Over current relay(fanI/D) Over current relay(fanO/D) High-pressure switch Thermostat(freeze protection) Auxiliary relay (fan) Auxiliary relay (fan) Auxiliary relay Auxiliary relay (check) Connector Surge killer Timer (2sec.) Controller connection. Symbol No. TB3 2,3 1 4 5 Function Power (Active) Cooling operation Fan operation Power (Neutral) PAC-204RC terminal no. 24VAC(L) 2:COMP1 3:COMP2 FAN HI 24VAC (N) C26 1 26L2 3 3 12 TB3 3 4 GRAY 11 12 11 12 OUTDOOR CZ 1-2 FZ CZ 2-2 13 5 GRAY Note: 1. 2. 3. 4. CZ 2-1 GRAY 4 5 Symbol MC1,2 MF1 MF2 52C1,2 52F1 52F2 TB1~5 CH1,2 F1~3 Tr 49C1,2 51C1,2 51F1 51F2 63H1,2 26L1,2 FZ 30FZ CZ1-1,2/2-1,2 30CZ1,2 C03,04,11,13, 14,16,23,24,26 CR1~3 2 1 26L1 TB4 CR1 PINK 30 FZ 3 CZ 1-2 GRAY GRAY 17 16 18 3 20 PINK CZ 1-1 1 Tr C03 6 TB3 C04 1 51F1 PINK 52F1 1 1 GRAY FAN HI BLUE 24VAC(L) N 13 CR3 COMP2 CIRCUIT BREAKER (FIELD SUPPLY) PE-15MYC1-EU···30A RED L2 L3 GRAY 52 F2 2 N 52F1 L1 29 ORANGE CZ2-2 52 ORANGE C2 COMP1 POWER SUPPLY 380~415VAC 3N~PE 50Hz 13 30 CZ2 BLUE TB2 PINK 2 CZ 2-2 CZ 2-1 ORANGE 51C2 27 24VAC(N) INDOOR 11 12 12 GRAY GRAY 28 30 CZ2 30 CZ1 11 30 2 CR2 52 VIOLET C1 52 C2 TB4 63H2 63H1 C23 C13 52 C1 49C2 24 VIOLET 1 GRAY 13 The dotted lines show field wiring. The figure in the parenthesis show field supply parts. Color of earth wire is yellow and green twisting. In case of power supply 380V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 5. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays <51C1,2>, <51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. This timer <2> installed because the power supply breaker may operate if two compressors start at the same time. 3. Do not change factory set value of all timers. 4. This motor (*1) includes auto reset type internal thermostat. - 52 - C11RED 1 WHITE 2 BLACK 3 WHITE WHITE F3(3.15A) MC1 BLACK BLACK BLACK BLUE PE 51C1 RED WHITE MF2 (*1) PE-20MYC-EU/PU-20MYC1-EU (STANDARD) OUTDOOR TB1 L2 L3 N RED 51C1 52C1 RED L1 POWER SUPPLY 380~415VAC 3N~PE 50Hz WHITE 51C2 52C2 RED PE CIRCUIT BREAKER (FIELD SUPPLY) PU-20MYC1-EU···125A WHITE BLACK BLACK F3 (3.15A) 52F2 L1 RED 24 52 C2 19 25 17 C14 C24 20 1 21 3 2 26 51C1 CR2 30 CZ1 52 VIOLET C1 22 30 CZ1 2 52 ORANGE C2 RED L2 L3 WHITE 52 F2 2 N GRAY 13 BLUE 51F1 L1 F2 (3.15A) NOTE 4 C03 SILVER 1 1 AC 24V 18 C03 3 20 PINK 30 FZ 30 FZ 3 3 PAC-204RC 11 2 TB3 2 Name Compressor motor Fan motor (indoor) Fan motor (outdoor)(*1) Contactor (compressor) Contactor (fan I/D) Contactor (fan O/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat(compressor) Over current relay(compressor) Over current relay(fanI/D) Over current relay(fanO/D) High-pressure switch Thermostat(freeze protection) Auxiliary relay (fan) Auxiliary relay (fan) Auxiliary relay Auxiliary relay (check) Connector Surge killer Timer (2sec.) Controller connection. Symbol No. Function 1 TB3 2,3 4 5 Power (Active) Cooling operation Fan operation Power (Neutral) C26 1 26L2 3 3 12 TB3 11 3 GRAY3 CZ 1-1 GRAY CZ 1-2 4 12 OUTDOOR 4 CZ 2-1 GRAY 5 GRAY 12 CZ 2-2 13 FZ 5 Symbol MC1,2 MF1 MF2,3 52C1,2 52F1 52F2 TB1~5 CH1,2 F1~3 Tr 49C1,2 51C1,2 51F1 51F2,3 63H1,2 26L1,2 FZ 30FZ CZ1-1,2/2-1,2 30CZ1,2 C03,04,11,13,14, 16,21,23,24,26 CR1~3 2 1 26L1 11 52 F1 BLUE N CZ 1-2 TB4 CR1 PINK 16 C16 Tr PINK 19 CZ 1-1 GRAY GRAY 17 C03 C04 51F1 FZ 6 TB3 FAN HI RED 1 52F1 1 1 GRAY 24VAC(L) PE CZ 2-2 MF1 F1 (3.15A) RED CIRCUIT BREAKER (FIELD SUPPLY) PE-20MYC-EU···30A 12 13 BLACK BLUE 11 CZ 2-1 30 CR3 52F1 L1 N 1 WHITE 2 BLACK 3 GRAY GRAY 12 11 ORANGE 51C2 CZ 2-2 30 CZ2 COMP2 POWER SUPPLY 380~415VAC 3N~PE 50Hz 1 WHITE 2 BLACK 3 C21RED BLACK 29 30 CZ2 N BLUE 2 28 TB2 INDOOR C11RED WHITE 1 COMP1 N 23 27 VIOLET CZ2-1 3 51F3 MC2 63H2 63H1 CH2 CH1 1 PINK TB4 C23 1 52 C2 RED 31 24VAC(N) C13 52 C1 ORANGE BLACK 49C2 49C1 52 C1 ORANGE WHITE 51 F3 VIOLET 51F2 RED RED 51 F2 16 VIOLET RED WHITE 18 MC1 BLACK BLACK BLACK BLUE TB5 RED WHITE WHITE GRAY 13 Note:1. The dotted lines show field wiring. 2. The figure in the parenthesis show field supply parts. 3. Color of earth wire is yellow and green twisting. 4. In case of power supply 380V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 5. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays <51C1,2>,<51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. This timer <2> installed because the power supply breaker may operate if two compressors start at the same time. 3. Do not change factory set value of all timers. 4. This motor (*1) includes auto reset type internal thermostat. PAC-204RC terminal no. 24VAC(L) 2:COMP1 3:COMP2 FAN HI 24VAC (N) - 53 - MF2 (*1) MF3 (*1) PE-7MYC-EU / PU-7MYC1-EU (SPECIAL ORDER : LOW AMBIENT COOLING) OUTDOOR TB1 L2 RED F3(3.15A) BLUE WHITE BLACK BLACK CIRCUIT BREAKER (FIELD SUPPLY) PU-7MYC1-EU···50A 52C C11 1 WHITE 2 BLACK 3 51F2 17 MC 51F2 RED L1 RED PE 51C RED WHITE L3 N 52C RED L1 POWER SUPPLY 380~415VAC 3N~PE 50Hz LOW AMBIENT COOLING PARTS L1 U C11 L2 V L3 W C21 VIOLET TH 49C 18 C14 TB5 1 16 VIOLET 15 RED 1 2 3 RED WHITE BLACK BLACK GRAY 2 19 CZ2 C13 51C 1 22 VIOLET CZ2 CH 14 20 3 30 CZ 21 GRAY 14 CR2 VIOLET 52C 30 CZ TB6 N N (*1) JUMPER INDOOR TB2 L POWER SUPPLY 220~240VAC ~PE 50Hz TB4 51F1 52F RED L TB4 Hi C01 RED 6 6 5 BROWN 2 Low RED F1 (3.15A) L CIRCUIT BREAKER (FIELD SUPPLY) PE-7MYC-EU···15A RED NOTE 5 C03 C03 C04 1 TB4 GRAY 1 19 PINK GRAY 1 26L 15 3 15 TB3 15 C03 3 3 OUTDOOR 3 TB4 30FZ 18 16 C16 COMP1 FZ 8 CZ1 24VAC(N) AC 24V Tr 52F 21 PAC-204RC 1 RED SILVER PINK 4 1 1 C PINK F2 (3.15A) 51F1 17 BLUE FAN HI PE 7 SW2(FIELD SUPPLY) BLUE C01 PINK 20 MF1 5 6 24VAC(L) N (*2) 1 7 CZ2 3 2 CR1 2 PINK GRAY 14 GRAY 3 52F 30 FZ BLUE Symbol MC MF1 MF2,3 52C 52F TB1~6 CH F1~3 Tr 49C 51C 51F1,2 63H 26L FZ CZ1,2 30CZ,FZ SW1 C C01,03,04,11, 13,14,16,21 CR1,2 Name Compressor motor Fan motor (indoor)(*2) Fan motor (outdoor)(*2) Contactor (compressor) Contactor (fan I/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat (compressor) Over current relay (compressor) Over current relay(fanI/D,O/D) High-pressure switch Thermostat (compressor) Auxiliary relay (fan) Auxiliary relay (compressor) Auxiliary relay (check) Switch (Fan Hi-Low) Run capacitor Connector Surge killer Controller connection. Symbol No. TB4 1 2 3 4 Function Power (Active) Cooling operation Fan operation Power (Neutral) PAC-204RC terminal no. 24VAC(L) COMP1 FAN HI 24VAC (N) BLUE GRAY 14 FZ CZ1 N 4 4 GRAY Note: 1. 2. 3. 4. The dotted lines show field wiring. The figure in the parenthesis show field supply parts. Color of earth wire is yellow and green twisting. Please remove the jumper wire ((*1) Mark) in the left diagram if you use the switch <SW1> at local. If the switch <SW1> is not used, the fan motor (indoor) drives at high speed. 5. In case of power supply 220V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 6. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays <51C>, <51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. This motor (*2) includes auto reset type internal thermostat. - 54 - MF2 (*2) WHITE C21 15 63H 1 2 3 MF3 (*2) PE-8,10MYC-EU / PU-8,10MYC1-EU (SPECIAL ORDER : LOW AMBIENT COOLING) TB1 OUTDOOR RED L1 L2 POWER SUPPLY 380~415VAC 3N~PE 50Hz RED L3 N 52C WHITE BLACK BLACK F3(3.15A) L1 BLUE 51F2 CIRCUIT BREAKER (FIELD SUPPLY) WHITE 2 BLACK 3 52C L1 U LOW AMBIENT COOLING PARTS L2 V L3 W TH TB5 18 16 VIOLET C14 15 1 19 C13 22 VIOLET CZ2 30 CZ 3 21 TB6 30 CZ 51F1 52F RED L2 L3 WHITE C01RED 1 2 3 BLACK RED WHITE BLACK BLUE TB2 L1 RED 14 CR2 F1 (3.15A) L1 WHITE C02 RED MF1 BLUE WHITE 1 BLUE 2 3 RED N TB4 GRAY PE C01 1 4 49F C03 20 17 FZ 3 3 30FZ Controller connection. Symbol No. Function TB4 1 2 3 4 Power (Active) Cooling operation Fan operation Power (Neutral) 3 2 CZ2 GRAY PAC-204RC terminal no. 24VAC(L) COMP1 FAN HI 24VAC (N) GRAY 3 14 52F BLUE GRAY 14 FZ CZ1 Symbol Name Compressor motor MC MF1 Fan motor (indoor) MF2,3 Fan motor (outdoor)(*1) 52C Contactor (compressor) 52F Contactor (fan I/D) TB1~6 Terminal block CH Crankcase heater F1~3 Fuse (3.15A) Tr Transformer 49F Internal thermostat(indoor fan) 49C Internal thermostat(compressor) Over current relay(compressor) 51C Over current relay(fanI/D,O/D) 51F1,2 High-pressure switch 63H 26L Thermostat(freeze pretection) FZ Auxiliary relay (fan) Auxiliary relay (compressor) CZ1,2 Auxiliary relay (check) 30CZ,FZ C01~04,11, 13,14,16,21 Connector Surge killer CR1,2 3 15 OUTDOOR 2 N 15 TB3 15 30 FZ BLUE 1 26L 3 CR1 PINK C16 GRAY PINK TB4 19 18 PAC-204RC AC 24V Tr 5 CZ1 C03 C04 1 SILVER 1 FAN HI RED 8 24VAC(L) 51F1 PINK COMP1 16 52F 1 1 F2 (3.15A) 24VAC(N) CIRCUIT BREAKER (FIELD SUPPLY) PE-8,10MYC-EU···15A NOTE 4 C03 4 4 C01 1 2 3 GRAY Attach the accessory Remove C02 1 2 3 MF1 1 2 3 This circuit diagram shows connections. (If the external static pressure is less than 30 pa, change to connections.) Note: 1. 2. 3. 4. The dotted lines show field wiring. The figure in the parenthesis show field supply parts. Color of earth wire is yellow and green twisting. In case of power supply 380V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 5. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays<51C>, <51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. This motor (*1) includes auto reset type internal thermostat. - 55 - MF2 (*1) VIOLET 52C N N BLACK GRAY 14 20 CH WHITE CZ2 51C 1 RED 1 2 3 C21 GRAY 15 2 C11 1 2 3 49C 63H INDOOR C11 1 17 VIOLET PU- 8MYC1-EU···50A PU-10MYC1-EU···60A POWER SUPPLY 380~415VAC 3N~PE 50Hz MC 51F2 RED RED PE 51C RED WHITE MF3 (*1) PEH-5MYA-EU/PUH-5MYE1-EU (STANDARD) TB1 OUTDOOR L2 POWER SUPPLY 380~415VAC 3N~PE 50Hz RED 51C RED WHITE WHITE BLACK L1 RED CIRCUIT BREAKER (FIELD SUPPLY) PUH-5MYE1-EU···50A (*1) HZ2 51F2 17 22 FC TB6 VIOLET C14 52C 1C11RED 2 WHITE MF2 3 BLACK X1 WHITE F3(3.15A) PE (*1) 51F2 RED BLUE MC BLACK BLACK L3 N 52C RED L1 1 BROWN 16 T1 X1 X2 X1 28 63H1 24 23 1 C18 25 18 VIOLET 1 15 19 21 VIOLET CZ2 BROWN 20 C15 CR2 21 S4 T1 VIOLET 52C TB6 N TB2 WHITE RED F1(3.15A) L1 N X WHITE U WHITE V Y BLUE MF1 Z RED W BLUE C02 2 3 1 RED PE 16 C01 TB4 1 GRAY 51F1 CIRCUIT BREAKER (FIELD SUPPLY) PEH-5MYA-EU···15A 14 T2 C01 RED 1 2 3 BLACK BLUE X1 NOTE 4 C03 PINK 4 RED 1 F2 (3.15A) C03 C04 SILVER 1 1 52F 1 24VAC(L) N GRAY BROWN BLUE 51F1 52F RED L2 L3 X2 3 N BLUE L1 14 27 1 30 CZ INDOOR 13 HZ2 CZ2 T2 30 CZ 3 TB5 26D BROWN 26 CH POWER SUPPLY 380~415VAC 3N~PE 50Hz 13 GRAY GRAY 2 51C C13 15 63H2 2 GRAY 6 CZ1 PAC-204RC GRAY TB3 HZ1 GRAY 15 13 15 13 15 13 PINK 30FZ OUTDOOR CZ2 TB4 C03 18 3 52F FAN HI PINK AC 24V Tr 19 FZ 4WV 5 COMP1 17 24VAC(N) 49F 3 3 CR1 GRAY 2 3 GRAY 3 2 CZ1 HZ1 4 GRAY 4 14 FZ 30 FZ 14 BLUE Symbol MC MF1 MF2 52C 52F TB1~6 CH F1~3 Tr 49F 51C 51F1 51F2 63H1 63H2 26D Name Compressor motor(*1) Fan motor (indoor) Fan motor (outdoor)(*1) Contactor (compressor) Contactor (fan I/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat(fan I/D) Over current relay(compressor) Over current relay(fan I/D) Over current relay(fan O/D) High-pressure switch High-pressure switch (defrost) Thermostat (defrost) HZ2 N Symbol 21S4 FZ CZ1,2 HZ1,2 30CZ,30FZ X1 X2 C01~04,11 13~15,18 T1 T2 CR1,2 GRAY 5 5 Name 4-Way valve Auxiliary relay (fan) Auxiliary relay (compressor) Auxiliary relay (4-way valve) Auxiliary relay (check) Contactor (fan O/D) Auxiliary relay (defrost) Connector Attach the accessory Remove C02 C01 1 2 3 RED U X WHITE WHITE V MF1 Y BLUE 2 Z RED 3 BLUE W 1 2 3 1 This circuit diagram shows connections. (If the external static pressure is less than 30 pa, change to connections.) Note: 1. The dotted lines show field wiring. 2. The figure in the parenthesis show field supply parts. 3. Color of earth wire is yellow and green twisting. 4. In case of power supply 380V AC model Tr wiring. Timer Timer Surge killer C03 1 C03 1 C04 1 RED SILVER AC 24V Tr Controller connection. PAC-204RC terminal no. Power (Active) 24VAC(L) Cooling or Heating operation COMP1 Revercing Valve 4WV for Heating operation FAN HI Fan operation 24VAC(N) Power (Neutral) C03 3 Symbol No. Function TB4 1 2 3 4 5 3 3 5. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current,over current relays<51C>,<51F1,2> are installed. Therefore,do not change factory set value of over current relays. 2. Do not change factory set value of timer. 3. This motor (*1) includes auto reset type internal thermostat. - 56 - PEH-7MYA-EU/ PUH-7MYC2-EU (STANDARD) OUTDOOR TB1 L2 RED F3(3.15A) BLUE WHITE BLACK BLACK L1 RED WHITE RED RED PE HZ2 51F2 17 CIRCUIT BREAKER (FIELD SUPPLY) PUH-7MYC2-EU···50A 16 C13 X1 X2 1 X1 GRAY T1 29 25 24 C18 26 1 13 GRAY 15 13 30 CZ VIOLET 52C WHITE MF3 BLACK (*2) C21 HZ2 26D GRAY 14 T2 28 3 X2 N BLUE (*2) RED 14 1 21 S4 T1 CR2 1 2 3 27 C15 VIOLET 30 CZ N BROWN BROWN 22 CZ2 20 21 1C11RED 2 WHITE MF2 3 BLACK 2 BROWN 51C 3 15 63H2 CZ2 2 1 CH TB6 TB5 63H1 VIOLET 19 X1 BLACK TB6 FC BROWN 18 C14 MC 51F2 23 VIOLET 49C 52C 51C RED WHITE L3 N 52C RED L1 POWER SUPPLY 380~415VAC 3N~PE 50Hz X1 T2 BLUE N (*1) JUMPER INDOOR TB2 L POWER SUPPLY 220~240VAC ~PE 50Hz TB4 51F1 52F RED L TB4 Hi 7 6 8 F1 (3.15A) BROWN BLUE 4 TB4 1 GRAY RED C01 PINK 20 MF1 5 6 52F C PINK 6 GRAY 1 C03 C04 1 SILVER 1 PINK 17 AC 24V Tr 19 PINK PAC-204RC 16 C16 15 TB3 FZ TB4 C03 30FZ 3 PINK 3 3 2 GRAY 3 GRAY 2 CR1 52F Symbol MC MF1 MF2,3 52C 52F TB1~6 CH F1~3 Tr 49C 51C 51F1 51F2 63H1 63H2 26L 26D Name Compressor motor Fan motor (indoor)(*2) Fan motor (outdoor)(*2) Contactor (compressor) Contactor (fan I/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat(compressor) Over current relay(compressor) Over current relay(fanI/D) Over current relay(fanO/D) High-pressure switch High-pressure switch (defrost) Thermostat(freeze protection) Thermostat (defrost) 1 3 15 13 15 13 OUTDOOR CZ2 3 HZ2 4 14 FZ 14 N BLUE HZ1 GRAY 13 4 GRAY CZ1 HZ1 30 FZ CZ1 GRAY 26L HZ1 FAN HI RED 51F1 F2 (3.15A) 24VAC(L) NOTE 5 C03 4WV CIRCUIT BREAKER (FIELD SUPPLY) PEH-7MYA-EU···15A 18 21 1 L COMP1 RED 24VAC(N) PE 8 SW1(FIELD SUPPLY) BLUE (*2) 1 2 Low N C01RED 7 Symbol 21S4 FZ CZ1,2 HZ1,2 30CZ,30FZ X1 X2 <SW1> C01,03,04,11 13~16,18,21 T1 T2 CR1,2 C BLUE GRAY Name 4-Way valve Auxiliary relay (fan) Auxiliary relay (compressor) Auxiliary relay (4-way valve) Auxiliary relay (check) Contactor (fan O/D) Auxiliary relay (defrost) Switch (Fan Hi-Low) Connector Timer Timer Surge killer Run capacitor 5 5 GRAY Note:1. The dotted lines show field wiring. 2. The figure in the parenthesis show field supply parts. 3. Color of earth wire is yellow and green twisting. 4. Please remove the jumper wire [(*1) Mark] in the left diagram if you use the switch <SW1> at local. If the switch <SW1> is not used, the fan motor (indoor) drives at higi speed. 5. In case of power supply 220V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 6. Specification subject to change without notice. Controller connection. Symbol No. Function TB4 1 2 3 4 5 Power (Active) Cooling or Heating operation Revercing Valve for Heating operation Fan operation Power (Neutral) Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays<51C>,<51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. Do not change factory set value of timer. 3. This motor (*2) includes auto reset type internal thermostat. PAC-204RC terminal no. 24VAC(L) COMP1 4WV FAN HI 24VAC(N) - 57 - PEH-8,10MYA-EU/PUH-8,10MYC2-EU (STANDARD) PEH-8,10MYA-EU/PUH-8,10MYE1-EU OUTDOOR L1 TB1 L2 POWER SUPPLY 380~415VAC 3N~PE 50Hz N 51C RED WHITE WHITE BLUE PE 1C11RED 2 WHITE MF2 3 BLACK X1 BLACK L1 RED (*1) 1C21 RED 2 WHITE MF3 3 BLACK HZ2 51F2 23 17 VIOLET BROWN FC TB6 (*1) 49C 52C 18 X1 X2 C14 16 51F2 RED WHITE F3(3.15A) PUH- 8MYC2-EU···50A PUH-10MYC2-EU···60A PUH- 8MYE1-EU···50A PUH-10MYE1-EU···60A MC BLACK BLACK L3 CIRCUIT BREAKER (FIELD SUPPLY) 52C RED RED 1 29 C18 26 25 24 63H1 VIOLET X1 T1 TB5 1 15 63H2 15 2 GRAY GRAY 2 19 C13 1 51C 26D 22 VIOLET CZ2 CH BROWN 3 C15 CR2 VIOLET 52C 21 S4 T1 TB2 WHITE C02 X WHITE U WHITE V Y BLUE 2 MF1 3 Z W RED BLUE C01 RED 1 2 3 BLACK RED N N BLUE F1 (3.15A) 1 L1 RED TB4 1 GRAY 51F1 SILVER 24VAC(L) RED C03 1 C04 1 1 4 49F AC 24V Tr 5 FZ PINK C03 3 3 TB4 GRAY N Symbol 26D 21S4 FZ CZ1,2 HZ1,2 30CZ,30FZ X1 X2 C01~04,11, 13~16,18,21 T1 T2 CR1,2 BLUE GRAY Name Thermostat (defrost) 4-Way valve Auxiliary relay (fan) Auxiliary relay (compressor) Auxiliary relay (4-way valve) Auxiliary relay (check) Contactor (fan O/D) Auxiliary relay (defrost) Connector Timer Timer Surge killer 4 5 15 2 3 HZ1 GRAY 13 1 GRAY 4 CZ2 FZ 13 13 HZ2 OUTDOOR 14 5 5 C01 1 2 3 3 15 15 4 GRAY 3 2 GRAY 14 Attach the accessory Remove C02 1 2 3 1 2 3 MF1 This circuit diagram shows connections. (If the external static pressure is less than 30 pa, change to connections.) Note: 1. 2. 3. 4. The dotted lines show field wiring. The figure in the parenthesis show field supply parts. Color of earth wire is yellow and green twisting. In case of power supply 380V AC model Tr wiring. C03 3 PAC-204RC terminal no. Power (Active) 24VAC(L) Cooling or Heating operation COMP1 Revercing Valve 4WV for Heating operation FAN HI Fan operation 24VAC(N) Power (Neutral) Symbol No. Function TB4 CZ1 GRAY C03 1 C03 1 C04 1 RED SILVER AC 24V Tr Controller connection. 1 2 3 C16 CZ1 HZ1 52F 30 FZ Name Compressor motor Fan motor (indoor) Fan motor (outdoor)(*1) Contactor (compressor) Contactor (fan I/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat(indoor fan) Internal thermostat(compressor) Over current relay(compressor) Over current relay(fan I/D) Over current relay(fan O/D) High-pressure switch High-pressure switch (defrost) Thermostat(freeze protection) 18 PAC-204RC 26L HZ1 CR1 PINK 19 GRAY TB3 3 30FZ Symbol MC MF1 MF2,3 52C 52F TB1~6 CH F1~3 Tr 49F 49C 51C 51F1 51F2 63H1 63H2 26L 6 20 17 BLUE 52F 1 4WV NOTE 4 C03 PINK 16 C01 F2 (3.15A) FAN HI PE COMP1 CIRCUIT BREAKER (FIELD SUPPLY) PEH-8,10MYA-EU···15A RED L2 L3 GRAY 14 T2 X1 51F1 52F L1 BROWN 24VAC(N) INDOOR X2 3 N BLUE 28 1 30 CZ POWER SUPPLY 380~415VAC 3N~PE 50Hz 14 T2 30 CZ 21 N CZ2 HZ2 27 BROWN 20 TB6 13 13 3 3 5. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays<51C>,<51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. Do not change factory set value of timer. 3. This motor (*1) includes auto reset type internal thermostat. - 58 - PEH-15,20MYA-EU/PUH-15,20MYC2-EU (STANDARD) OUTDOOR L1 TB1 WHITE BLACK BLACK BLUE N WHITE BLACK 52C2 WHITE F3(3.15A) RED L1 HZ2 52C2 C14 16 VIOLET ORANGE C13 19 C23 1 CH1 23 1 24 VIOLET C24 1 2 25 22 VIOLET 20 3 30 CZ1 3 T2 PINK 1 28 ORANGE 2 C28 1 2 30 CZ2 CZ 2-2 52 ORANGE 41 3 N 13 CZ 2-2 HZ2 GRAY T4 42 3 T3 X1 13 GRAY 12 14 BROWN N 12 GRAY 11 CZ 2-1 X4 T2 21 S4-2 T3 S4-1 2 C2 1 11 GRAY 26 D2 40 C25 X3 T1 (*1) TB4 63H 2-2 26 D1 35 C15 1 29 CR3 21 1C21 RED 2 WHITE MF3 3 BLACK X2 X2 44 PINK 39 63H 2-1 51C2 27 37 PINK X1 43 BROWN 34 C18 PINK 14 T4 X2 BLUE N 51F1 52F WHITE MF1 BLACK L1 GRAY RED NOTE 4 C03 C03 RED 1 SILVER 51F1 F2 (3.15A) 3 FZ 30 FZ 18 PINK 3 3 Symbol MC1,2 MF1 MF2,3 52C1,2 52F TB1~5 CH1,2 F1~3 Tr 49C1,2 51C1,2 51F1 51F2,3 63H1-1,1-2 63H2-1,2-2 26L1,2 26D1,2 21S4-1,2 FZ 30FZ CZ1-1,2/2-1,2 HZ1-1,2/2 30CZ1,2 X1,2 X3,4 C03,04,11,13~16, 18,21,23~26,28 T1,2 T3,4 2 CR1~3 GRAY CZ 1-1 GRAY C16 CZ 1-2 16 GRAY 13 HZ 1-1 GRAY C26 1 1 HZ HZ 26L1 1-1 26L2 1-2 3 3 11 12 TB3 11 12 13 11 12 13 OUTDOOR 19 PINK CR1 TB3 3 2 5 4 CZ 2-2 CZ 2-1 GRAY GRAY GRAY 3 4 5 GRAY 2 HZ2 52F CZ 1-1 30 FZ BLUE 7 15 1 AC 24V Tr C03 52F 1 TB3 C04 1 PINK 17 1 FAN HI PE CIRCUIT BREAKER (FIELD SUPPLY) PEH-15,20MYA-EU···30A 4WV F1 (3.15A) COMP2 BLUE 20VAC(L) N C1 38 51F3 WHITE BLACK X3 X2 2 2 30 CZ2 RED RED L2 L3 32 X4 BROWN 36 T1 COMP1 L1 33 BROWN 20VAC(N) INDOOR TB2 31 1 CR2 CZ 2-1 52 VIOLET 30 CZ1 BLUE X4 X1 ORANGE 26 21 N X3 63H1-2 63H1-1 51C1 CH2 51F3 49C2 49C1 18 15 51F2 MC2 BLACK 30 TB5 FC BROWN RED 17 52C1 (*1) 51C2 RED RED 1 C11RED 2 WHITE MF2 3 BLACK X1 RED WHITE BLACK RED PE POWER SUPPLY 380~415VAC 3N~PE 50Hz MC1 BLACK 51F2 CIRCUIT BREAKER (FIELD SUPPLY) PUH-15MYC2-EU···100A PUH-20MYC2-EU···125A TB5 51C1 RED WHITE WHITE L3 52C1 RED RED L2 POWER SUPPLY 380~415VAC 3N~PE 50Hz N GRAY Name Compressor motor Fan motor (indoor) Fan motor (outdoor)(*1) Contactor (compressor) Contactor (fan I/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat(compressor) Over current relay(compressor) Over current relay(fanI/D) Over current relay(fanO/D) High-pressure switch High-pressure switch (defrost) Thermostat(freeze protection) Thermostat (defrost) 4-Way valve Auxiliary relay (fan) Auxiliary relay (fan) Auxiliary relay Auxiliary relay (heater) Auxiliary relay (check) Contactor (fan O/D) Auxiliary relay (defrost) Connector Timer Timer Timer (2sec.) Surge killer CZ 1-2 HZ1 FZ 14 6 6 Note:1. 2. 3. 4. GRAY 14 The dotted lines show field wiring. The figure in the parenthesis show field supply parts. Color of earth wire is yellow and green twisting. In case of power supply 380V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 5. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays <51C1,2>, <51F1,2,3> are installed. Therefore, do not change factory set value of over current relays. 2. Timers<T1,2> are installed for defrost control. 3. This timer <2> installed because the power supply breaker may operate two compressors start at the same time. 4. Do not change factory set value of all timers. 5. This motor (*1) includes auto reset type internal thermostat. Controller connection. PAC-204RC terminal no. Power (Active) 24VAC(L) Cooling or Heating operation COMP1 Cooling or Heating operation COMP2 Revercing Valve 4WV for Heating operation Fan operation FAN HI Power (Neutral) 24VAC(N) Symbol No. Function TB3 1 2 3 4 5 6 - 59 - PEH-7MYA-EU / PUH-7MYC2-EU (SPECIAL ORDER : LOW AMBIENT COOLING) OUTDOOR TB1 L2 RED F3(3.15A) BLUE L1 WHITE BLACK BLACK HZ2 51F2 17 CIRCUIT BREAKER (FIELD SUPPLY) PUH-7MYC2-EU···50A TB6 FC BROWN 18 16 C13 X1 X2 1 25 C18 26 BROWN BROWN 22 3 VIOLET 52C 2 3 L3 W C21 1 2 3 TH FC RED WHITE BLACK RED WHITE BLACK C21 N FULL LOAD INPUT (ONLY HEAT PUMP) HZ2 14 26D GRAY T2 28 3 X2 N BLUE C11 1 L2 V 14 21 S4 T1 CR2 L1 U 2 1 20 30 CZ LOW AMBIENT COOLING PARTS 27 C15 VIOLET 30 CZ N 13 1 BROWN CZ2 21 13 GRAY 15 63H2 CZ2 2 51C 3 15 X1 GRAY T1 29 24 1 CH TB6 TB5 63H1 VIOLET 19 2 23 VIOLET C14 X1 C11 1 BLACK 49C 52C MC 51F2 RED WHITE RED RED PE 51C RED WHITE L3 N 52C RED L1 POWER SUPPLY 380~415VAC 3N~PE 50Hz X1 T2 BLUE N (*1) JUMPER INDOOR TB2 L POWER SUPPLY 220~240VAC ~PE 50Hz RED TB4 51F1 52F L TB4 Hi 6 F1 (3.15A) RED (*2) 1 BROWN 2 BLUE 4 TB4 1 GRAY C01 PINK 20 MF1 5 6 52F C PINK 6 GRAY RED 51F1 1 F2 (3.15A) C03 C04 1 SILVER 1 PINK 17 AC 24V Tr 19 PINK PAC-204RC 16 C16 15 TB3 FZ 30FZ 3 PINK Name Compressor motor Fan motor (indoor)(*2) Fan motor (outdoor)(*2) Contactor (compressor) Contactor (fan I/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat(compressor) Over current relay(compressor) Over current relay(fanI/D) Over current relay(fanO/D) High-pressure switch High-pressure switch (defrost) Thermostat(freeze protection) Thermostat (defrost) 3 3 Symbol 21S4 FZ CZ1,2 HZ1,2 30CZ,30FZ X1 X2 <SW1> C01,03,04,11 13~16,18,21 T1 T2 CR1,2 C TB4 4 5 Power (Active) Cooling or Heating operation Revercing Valve for Heating operation Fan operation Power (Neutral) 3 15 13 13 OUTDOOR 4 GRAY 3 CZ1 HZ1 BLUE GRAY Name 4-Way valve Auxiliary relay (fan) Auxiliary relay (compressor) Auxiliary relay (4-way valve) Auxiliary relay (check) Contactor (fan O/D) Auxiliary relay (defrost) Switch (Fan Hi-Low) Connector Timer Timer Surge killer Run capacitor CZ2 HZ2 4 14 FZ 5 5 GRAY Note:1. The dotted lines show field wiring. 2. The figure in the parenthesis show field supply parts. 3. Color of earth wire is yellow and green twisting. 4. Please remove the jumper wire [(*1) Mark] in the left diagram if you use the switch <SW1> at local. If the switch <SW1> is not used, the fan motor (indoor) drives at higi speed. 5. In case of power supply 220V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 6. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays<51C>,<51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. Do not change factory set value of timer. 3. This motor (*2) includes auto reset type internal thermostat. Controller connection. 1 2 3 1 14 N Symbol No. Function GRAY 2 CR1 3 2 GRAY 52F 30 FZ Symbol MC MF1 MF2,3 52C 52F TB1~6 CH F1~3 Tr 49C 51C 51F1 51F2 63H1 63H2 26L 26D HZ1 GRAY 13 15 TB4 C03 BLUE CZ1 GRAY 26L HZ1 FAN HI NOTE 5 C03 24VAC(L) CIRCUIT BREAKER (FIELD SUPPLY) PEH-7MYA-EU···15A 18 21 1 L 4WV RED COMP1 PE 8 Low 8 SW1(FIELD SUPPLY) BLUE 24VAC(N) N C01RED 7 7 PAC-204RC terminal no. 24VAC(L) COMP1 4WV FAN HI 24VAC(N) - 60 - MF2 (*2) MF3 (*2) PEH-8,10MYA-EU / PUH-8,10MYE1-EU PEH-8,10MYA-EU / PUH-8,10MYC2-EU (SPECIAL ORDER : LOW AMBIENT COOLING) TB1 BLUE RED WHITE F3(3.15A) PE PUH- 8MYC2-EU···50A PUH-10MYC2-EU···60A PUH- 8MYE1-EU···50A PUH-10MYE1-EU···60A FC N X1 24 51C C15 CR2 VIOLET 52C 21 S4 T1 X2 3 N BLUE TB2 RED F1 (3.15A) C01 RED X WHITE U WHITE V Y BLUE MF1 Z RED BLUE W C02 TB4 1 GRAY F2 (3.15A) NOTE 4 C03 RED C01 C03 C04 1 SILVER 1 1 4 49F AC 24V Tr 5 2 3 1 FZ PINK PINK C03 3 3 18 PAC-204RC C16 TB4 GRAY 30 FZ Symbol 26D 21S4 FZ CZ1,2 HZ1,2 30CZ,30FZ X1 X2 C01~04,11, 13~16,18,21 T1 T2 CR1,2 2 3 15 BLUE GRAY Name Thermostat (defrost) 4-Way valve Auxiliary relay (fan) Auxiliary relay (compressor) Auxiliary relay (4-way valve) Auxiliary relay (check) Contactor (fan O/D) Auxiliary relay (defrost) Connector Timer Timer Surge killer CZ1 HZ1 GRAY GRAY 13 1 GRAY 4 CZ2 FZ 13 13 HZ2 OUTDOOR 14 5 5 C01 1 2 3 3 15 15 4 GRAY 3 2 CZ1 HZ1 52F N GRAY 26L HZ1 CR1 19 Name Compressor motor Fan motor (indoor) Fan motor (outdoor)(*1) Contactor (compressor) Contactor (fan I/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat(indoor fan) Internal thermostat(compressor) Over current relay(compressor) Over current relay(fan I/D) Over current relay(fan O/D) High-pressure switch High-pressure switch (defrost) Thermostat(freeze protection) 6 TB3 3 30FZ BLUE 52F 1 20 17 GRAY 14 Attach the accessory Remove C02 1 2 3 1 2 3 MF1 This circuit diagram shows connections. (If the external static pressure is less than 30 pa, change to connections.) Note: 1. 2. 3. 4. The dotted lines show field wiring. The figure in the parenthesis show field supply parts. Color of earth wire is yellow and green twisting. In case of power supply 380V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr Controller connection. C03 3 PAC-204RC terminal no. Power (Active) 24VAC(L) Cooling or Heating operation COMP1 Revercing Valve 4WV for Heating operation FAN HI Fan operation 24VAC(N) Power (Neutral) Symbol No. Function 4 5 GRAY RED PE PINK TB4 13 L1 16 1 2 3 MF3 (*1) N 1 2 3 51F1 Symbol MC MF1 MF2,3 52C 52F TB1~6 CH F1~3 Tr 49F 49C 51C 51F1 51F2 63H1 63H2 26L BLACK 14 T2 BLUE 51F1 52F BROWN X1 BLACK N WHITE 14 28 1 30 CZ CIRCUIT BREAKER (FIELD SUPPLY) PEH-8,10MYA-EU···15A RED CZ2 HZ2 27 BROWN T2 30 CZ 21 WHITE MF2 (*1) BROWN 3 RED BLACK 26D 22 VIOLET CZ2 20 L2 L3 WHITE FULL LOAD INPUT (ONLY HEAT PUMP) TB5 15 63H2 2 1 L1 X1 1 RED 15 13 2 GRAY GRAY CH INDOOR T1 C18 29 26 25 1 2 3 C21 1 2 3 TH 1 19 POWER SUPPLY 380~415VAC 3N~PE 50Hz L3 W BROWN FC TB6 63H1 C11 L2 V 3 X2 C14 VIOLET N L1 U 2 23 18 TB6 LOW AMBIENT COOLING PARTS 49C 52C C13 C11 1 HZ2 51F2 17 VIOLET 16 X1 BLACK L1 RED MC BLACK 51F2 FAN HI N RED WHITE BLACK L3 CIRCUIT BREAKER (FIELD SUPPLY) 51C WHITE 24VAC(L) POWER SUPPLY 380~415VAC 3N~PE 50Hz 52C RED RED 4WV L2 COMP1 L1 24VAC(N) OUTDOOR 3 3 5. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays<51C>,<51F1,2> are installed. Therefore, do not change factory set value of over current relays. 2. Do not change factory set value of timer. 3. This motor (*1) includes auto reset type internal thermostat. - 61 - PEH-15,20MYA-EU / PUH-15,20MYC2-EU (SPECIAL ORDER : LOW AMBIENT COOLING) OUTDOOR L1 TB1 WHITE BLACK BLACK BLUE N WHITE BLACK 52C2 RED L1 HZ2 52C2 C14 VIOLET ORANGE 19 C23 C13 1 1 CH1 23 24 VIOLET C24 1 2 25 22 VIOLET 20 TB2 28 30 CZ2 ORANGE 2 CZ 2-2 52 T2 C28 TH1 41 3 N L3 W GRAY GRAY 11 12 13 CZ 2-1 CZ 2-2 TH2 FC N HZ2 GRAY PINK 14 T4 X2 BLUE N 51F1 52F WHITE MF1 BLACK L1 GRAY RED NOTE 4 C03 C03 RED 1 SILVER 51F1 F2 (3.15A) 1 Tr C03 3 FZ 30 FZ 18 3 3 GRAY C16 TB3 Symbol MC1,2 MF1 MF2,3 52C1,2 52F TB1~5 CH1,2 F1~3 Tr 49C1,2 51C1,2 51F1 51F2,3 63H1-1,1-2 63H2-1,2-2 26L1,2 26D1,2 21S4-1,2 FZ 30FZ CZ1-1,2/2-1,2 HZ1-1,2/2 30CZ1,2 X1,2 X3,4 C03,04,11,13~16, 18,21,23~26,28 T1,2 T3,4 2 CR1~3 3 2 GRAY CZ 1-2 16 GRAY 13 HZ 1-1 GRAY C26 1 1 HZ HZ 26L1 1-1 26L2 1-2 3 3 11 12 TB3 4 5 11 12 11 12 3 4 CZ 2-2 CZ 2-1 GRAY GRAY GRAY 13 13 HZ2 5 52F CZ 1-1 N GRAY CZ 1-1 15 2 PINK 7 OUTDOOR 19 PINK CR1 30 FZ BLUE 1 TB3 1 AC 24V PINK 17 1 C04 FAN HI PE CIRCUIT BREAKER (FIELD SUPPLY) PEH-15,20MYA-EU···30A 52F 4WV F1 (3.15A) COMP2 BLUE GRAY CZ 1-2 6 Name Compressor motor Fan motor (indoor) Fan motor (outdoor)(*1) Contactor (compressor) Contactor (fan I/D) Terminal block Crankcase heater Fuse (3.15A) Transformer Internal thermostat(compressor) Over current relay(compressor) Over current relay(fanI/D) Over current relay(fanO/D) High-pressure switch High-pressure switch (defrost) Thermostat(freeze protection) Thermostat (defrost) 4-Way valve Auxiliary relay (fan) Auxiliary relay (fan) Auxiliary relay Auxiliary relay (heater) Auxiliary relay (check) Contactor (fan O/D) Auxiliary relay (defrost) Connector Timer Timer Timer (2sec.) Surge killer HZ1 FZ 14 6 GRAY Note:1. 2. 3. 4. 14 The dotted lines show field wiring. The figure in the parenthesis show field supply parts. Color of earth wire is yellow and green twisting. In case of power supply 380V AC model Tr wiring. C03 1 C03 1 C04 1 RED SILVER AC 24V Tr C03 3 3 3 5. Specification subject to change without notice. Caution, 1. To protect each fan motor and compressor from abnormal current, over current relays <51C1,2>, <51F1,2,3> are installed. Therefore, do not change factory set value of over current relays. 2. Timers<T1,2> are installed for defrost control. 3. This timer <2> installed because the power supply breaker may operate two compressors start at the same time. 4. Do not change factory set value of all timers. 5. This motor (*1) includes auto reset type internal thermostat. Controller connection. PAC-204RC terminal no. Power (Active) 24VAC(L) Cooling or Heating operation COMP1 Cooling or Heating operation COMP2 Revercing Valve 4WV for Heating operation Fan operation FAN HI Power (Neutral) 24VAC(N) Symbol No. Function TB3 1 2 3 4 5 6 - 62 - 1 2 3 RED WHITE BLACK MF3 (*1) FULL LOAD INPUT (ONLY HEAT PUMP) 14 3 T3 X1 L2 V 13 GRAY T4 42 BROWN N TB4 12 LOW AMBIENT COOLING PARTS C21 L1 U 3 11 X4 T2 1 2 26 D2 40 1 21 S4-2 T3 2 N X2 1 2 C25 X3 T1 S4-1 FC MC2 51F3 63H 2-2 (*1) FULL LOAD INPUT (ONLY HEAT PUMP) X2 44 PINK 39 PINK 1 26 D1 35 C15 1 29 CR3 21 C2 ORANGE 30 CZ2 37 PINK 2 51C2 27 38 63H 2-1 20VAC(L) N C1 VIOLET RED RED L2 L3 2 2 WHITE MF2 3 BLACK L3 W 51C2 WHITE BLACK X3 X2 X1 BROWN 34 C18 BROWN 1 COMP1 L1 X4 BROWN 36 43 20VAC(N) INDOOR 33 32 ORANGE CR2 CZ 2-1 52 30 CZ1 BLUE X4 X1 T1 26 30 CZ1 3 21 N X3 31 63H1-2 63H1-1 51C1 CH2 3 51F3 49C2 49C1 18 16 51F2 C11 1 RED L2 V BLACK 30 TB5 FC BROWN RED 17 LOW AMBIENT COOLING PARTS L1 U 3 WHITE F3(3.15A) 15 1 2 RED RED 52C1 X1 RED WHITE BLACK RED CIRCUIT BREAKER (FIELD SUPPLY) PUH-15MYC2-EU···100A PUH-20MYC2-EU···125A POWER SUPPLY 380~415VAC 3N~PE 50Hz MC1 BLACK 51F2 PE TB5 51C1 RED WHITE WHITE L3 52C1 RED RED L2 POWER SUPPLY 380~415VAC 3N~PE 50Hz ELECTRICAL OPERATION FLOW CHARTS PE-7,8,10MYC-EU PEH-5MYA-EU, PEH-7,8,10MYA-EU START START POWER ON POWER ON CH ON CH ON 30FZ,30CZ ON (SELF HOLD) 30FZ,30CZ ON (SELF HOLD) LCD controller ON? NO YES YES FZ ON FZ ON 52F ON MF1 OPERATE LCD controller COMP ON? 52F ON MF1 OPERATE NO YES CZ1,2 NO LCD controller ON? NO COOL MODE? HZ1,2 ON 21S4 YES ON NO LCD controller COMP ON? 52C ON MC OPERATE MF2, 3 OPERATE NO YES CZ1 LCD controller COMP ON? ON YES CZ1,2 CH OFF SAFETY DEVICE OFF? YES 30CZ 52C MC MF1 MF2,3 CH 52C ON MC OPERATE MF2, 3 OPERATE NO OFF OFF STOP Note STOP ON CH ON ON 52C ON MC OPERATE MF2, 3 OPERATE OFF CH OFF SAFETY DEVICE OFF? YES 30CZ 52C MC MF1 MF2,3 NO PASS THE 30 MIN ? (T1) NO YES OFF 26D ON ? Condensing -4±1.5˚C temp. OFF STOP Note STOP NO YES T2 ON X1 ON (SELF HOLD) SERVICE CALL CH X2 ON ON 21S4 OFF T1 OFF MF2, 3 STOP SERVICE CALL PASS THE 15 MIN ? (T2) Note. 1. When the fault of outdoor unit is occurred, the fan(MF1) of indoor unit continues to work. But the unit doesn't work correctly (not cooling and heating ). Then, turn off the power supply and check outdoor unit. NO YES X1 OFF T2 OFF X2 OFF 21S4 T1 ON MF2, 3 OPERATE - 63 - YES 26D OFF? Condensing 26±1.5˚C temp. or 63H2 OFF? High pressure 2.16MPa NO PE-15MYC1-EU PE-20MYC-EU START START POWER ON POWER ON CH1,2 ON CH1,2 ON 30FZ,30CZ1,2 ON (SELF HOLD) 30FZ,30CZ1,2 ON (SELF HOLD) NO LCD controller ON? YES YES FZ ON FZ ON 52F1 ON MF1 OPERATE 52F1 ON MF1 OPERATE NO LCD controller COMP ON? NO LCD controller COMP ON? YES YES CZ1-1,CZ2-1 ON CZ1-1,CZ2-1 ON 52C1 ON MC1 OPERATE MF2 OPERATE 52C1 ON MC1 OPERATE MF2 OPERATE CH 1 OFF CH 1 CZ1-2,CZ2-2 ON TIMER 2 ON NO PASS THE 3 MIN? 52C2 ON MC2 OPERATE CH2 OFF CH2 No.2 SAFETY DEVICE OFF? YES 30CZ1 OFF YES 30CZ2 OFF CH1 NO 52C2 ON MC2 OPERATE MF3 OPERATE No.1 SAFETY DEVICE OFF? 52C1 MC1 MF2 OFF CZ1-2,CZ2-2 ON TIMER 2 ON PASS THE 3 MIN? NO NO LCD controller ON? 52C2 MC2 MF2 OFF STOP STOP CH2 ON NO OFF STOP STOP NO No.1 SAFETY DEVICE OFF? No.2 SAFETY DEVICE OFF? YES 30CZ1 OFF YES 30CZ2 OFF 52C1 MC1 MF2,3 ON CH1 SERVICE CALL OFF 52C2 MC2 MF2,3 OFF STOP STOP CH2 ON SERVICE CALL Note: When the fault of outdoor unit is occurred, the fan(MF1) of indoor unit continues to work. But the unit doesn’t work correctly (not cooling ). Then, turn off the power supply and check outdoor unit. When the fault of indoor unit is occurred, both indoor unit and outdoor unit is stop. - 64 - OFF STOP STOP ON NO PEH-15,20MYA-EU START POWER ON CH1,2 ON 30FZ,30CZ1,2 ON (SELF HOLD) NO LCD controller ON? YES FZ ON 52F1 ON MF1 OPERATE NO COOL MODE? HZ1,2 ON 21S4-1,2 ON T1,T2 ON YES NO LCD controller COMP ON? YES YES CZ1-1,CZ2-1 ON CZ1-1,CZ2-1 ON 52C1 MC1 MF2 52C1 MC1 MF2 CH 1 ON OPERATE OPERATE CH 1 OFF NO PASS THE 3 MIN? OFF PASS THE 3 MIN? YES CH 2 ON OPERATE OPERATE CZ1-2,CZ2-2 ON TIMER 2 ON CZ1-2,CZ2-2 ON TIMER 2 ON 52C2 MC2 MF3 NO LCD controller COMP ON? NO PASS THE 30 MIN ON? (T1) YES ON OPERATE OPERATE 52C2 MC2 MF3 OFF CH 2 ON OPERATE OPERATE PASS THE 30 MIN ON? (T2) NO YES NO 26D1 ON? Condensing -4±1.5˚C temp. OFF YES X4 ON? No.1 SAFETY DEVICE OFF? No.2 SAFETY DEVICE OFF? YES 30CZ1 OFF 52C1 MC1 MF2 CH1 YES 30CZ2 OFF OFF STOP STOP 52C2 MC2 MF3 ON CH2 SERVICE CALL OFF STOP STOP ON NO NO No.1 SAFETY DEVICE OFF? No.2 SAFETY DEVICE OFF? YES 30CZ1 OFF 52C1 MC1 MF2 CH1 NO 26D2 ON? Condensing -4±1.5˚C temp. YES NO NO YES YES 30CZ2 OFF OFF STOP STOP 52C2 MC2 MF3 ON CH2 SERVICE CALL OFF STOP STOP NO X3 ON? NO NO YES YES X1 ON (SELF HOLD) T3 ON X2 ON (SELF HOLD) T4 ON X3 ON X4 ON 21S41 OFF T1 OFF MF2 STOP 21S42 OFF T2 OFF MF3 STOP ON PASS THE 15 MIN ON? (T3) NO NO 26D1 OFF? Condensing 26±1.5˚C temp. or 63H2-1 OFF? High pressure 2.16MPa YES X1 OFF T3 OFF NO NO 26D2 OFF? Condensing 26±1.5˚C temp. or 63H2-2 OFF? High pressure 2.16MPa YES YES X2 OFF T4 OFF X3 OFF X4 OFF 21S41, T1 ON MF2 OPERATE 21S42, T2 ON MF3 OPERATE Note: When the fault of outdoor unit is occurred, the fan(MF1) of indoor unit continues to work. But the unit doesn't work correctly (not cooling ). Then, turn off the power supply and check outdoor unit. When the fault of indoor unit is occurred, both indoor unit and outdoor unit is stop. - 65 - PASS THE 15 MIN ON? (T4) YES REFRIGERANT SCHEMATICS PE-7,8,10,20MYC-EU PE-15MYC1-EU INDOOR PE Evaporator BRAZING FRANGE FLARE OUTDOOR PU Condenser High pressure switch Service port Check joint Strainer Ball valve COOL Muffler Accumulator Check joint Compressor Capillary Tube Strainer Ball valve Note: PE-15MYC1,20MYC-EU is comprised of two refrigerant cycles. PEH-5,7,8,10,15,20MYA-EU BRAZING FRANGE FLARE INDOOR PEH Evaporator OUTDOOR PUH Condenser High pressure switch Service port Check joint Strainer Strainer 4-Way valve High pressure switch (defrost) Ball valve HEAT COOL Muffler Accumulator Check joint Compressor Capillary Tube Check valve Strainer Capillary Tube Check valve Ball valve Strainer Note: PEH-15,20MYA-EU is comprised of two refrigerant cycles. - 66 - SAFETY & CONTROL DEVICES PE-7,8,10MYC-EU PE-15MYC1-EU PE-20MYC-EU NO. PE-7MYC-EU PU-7MYC1-EU PE-8MYC-EU PU-8MYC1-EU PE-10MYC-EU PU-10MYC1-EU COMPRESSOR OVER CURRENT RELAY 51C 19.0A 22.0A 31.0A COMPRESSOR INTERNAL THERMOSTAT 49C 105 ± 5 ˚C OF83 ± 11 ˚C ON HIGH PRESSURE SWITCH 63H 2.94MPa OFF INDOOR FAN MOTOR OVER CURRENT RELAY 51F1 INDOOR FAN MOTOR INTERNAL THERMOSTAT - 150 ˚C OFF OUTDOOR FAN MOTOR OVER CURRENT RELAY 51F2 2.5A OUTDOOR FAN MOTOR INTERNAL THERMOSTAT - 150 ˚C OFF ITEM FUSE F1 ITEM 5.0A 3.5A 3 NO. 3.15A PE-15MYC1-EU PE-20MYC-EU PU-15MYC1-EU PU-20MYC1-EU COMPRESSOR OVER CURRENT RELAY 51C1,2 22.0A 31.0A COMPRESSOR INTERNAL THERMOSTAT 49C 105 ± 5 ˚C OFF 83 ± 11 ˚C ON HIGH PRESSURE SWITCH INDOOR FAN MOTOR OVER CURRENT RELAY 63 3.24MPa OFF 51F1 4.6A 7.2A OUTDOOR FAN MOTOR OVER CURRENT RELAY 51F2,3 2.5A OUTDOOR FAN MOTOR INTERNAL THERMOSTAT - 150 ˚C OFF FUSE F1 3 - 67 - 3.15A 5.0A PEH-7,8,10MYA-EU PEH-15,20MYA-EU ITEM NO. PEH-8MYA-EU PUH-8MYC2-EU PUH-8MYE1-EU PEH-5MYA-EU PEH-7MYA-EU PUH-5MYE1-EU PUH-7MYC2-EU COMPRESSOR OVER CURRENT RELAY 51C 15.0A 19.0A COMPRESSOR INTERNAL THERMOSTAT 49C 110 ± 5˚C OFF 61 ± 9˚C ON 22.0A 105 ± 5˚C OFF 83 ± 11˚C ON HIGH PRESSURE SWITCH 63H1 2.94MPa OFF HIGH PRESSURE SWITCH (DEFROST) 63H2 2.16MPa OFF 26D -4 ± 1.5 ˚C ON,26± 1.5 ˚C OFF 26D1,2 - FROST PROTECTOR INDOOR FAN MOTOR OVER CURRENT RELAY 51F1 INDOOR FAN MOTOR INTERNAL THERMOSTAT - OUTDOOR FAN MOTOR OVER CURRENT RELAY 51F2 2.5A - 150˚C OFF OUTDOOR FAN MOTOR INTERNAL THERMOSTAT FUSE F1 ITEM COMPRESSOR OVER CURRENT RELAY COMPRESSOR INTERNAL THERMOSTAT 5.0A 3.5A 150˚C OFF 3 NO. 51C1,2 3.15A PEH-10MYA-EU PEH-15MYA-EU PUH-10MYC1-EU PUH-15MYC1-EU PUH-10MYE-EU 31.0A 63H1-1 PEH-20MYA-EU PUH-20MYC1-EU 22.0A 31.0A 105 ± 5 ˚C OFF 83 ± 11˚C ON 49C 63H1 HIGH PRESSURE SWITCH 3.5A 2.94MPa OFF - - 2.94MPa OFF 2.16MPa OFF - - 2.16MPa OFF 63H1-2 63H2 HIGH PRESSURE SWITCH (DEFROST) 63H2-1 63H2-2 26D FROST PROTECTOR -4 ± 1.5 ˚C ON, 26 ± 1.5 ˚C OFF -4 ± 1.5 ˚C ON, 26 ± 1.5 ˚C OFF 26D1,D2 - INDOOR FAN MOTOR OVER CURRENT RELAY 51F1 5.0A OUTDOOR FAN MOTOR OVER CURRENT RELAY 51F 2.5A - 150˚C OFF OUTDOOR FAN MOTOR INTERNAL THERMOSTAT FUSE F1 3 - 68 - 4.6A 3.15A 7.2A SPECIAL ORDER Description Model PEH-5MYA PEH-7MYA PEH-8MYA PEH-10MYA PEH-15MYA PEH-20MYA Service ref. PEH-5MYA-EU PEH-7MYA-EU PEH-8MYA-EU PEH-10MYA-EU PEH-15MYA-EU PEH-20MYA-EU Heat pump _ * Low Ambient Cooling PAC-205FC Anti corrosion (Service reference) (PUH-5MYE1-EUS) (PUH-7MYC2-EUS) * Low ambient cooling Description (PUH-8MYC2-EUS, (PUH-10MYC2-EUS, (PUH-15MYC2-EUS) (PUH-20MYC2-EUS) PUH-8MYE1-EUS) PUH-10MYE1-EUS) It is possible to conduct cooling operation under an outdoor temperature even down to -5 ˚C. Model PE-7MYC PE-8MYC PE-10MYC PE-15MYC PE-20MYC Service ref. PE-7MYC-EU PE-8MYC-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU Cooling only * Low Ambient Cooling PAC-205FC _ Anti corrosion (Service reference) (PU-7MYC1-EUS) * Low ambient cooling (PU-8MYC1-EUS) (PU-10MYC1-EUS) (PU-15MYC1-EUS) (PU-20MYC1-EUS) It is possible to conduct cooling operation under an outdoor temperature even down to -5 ˚C. - 69 - PHYSICAL DATA PE-7,8,10,20MYC-EU PE-15MYC1-EU [ PRODUCT] Product type Product number : PACKAGE AIR COOLED HEATPUMP UNITS Indoor unit Outdoor unit Cooling capacity (AS1861) Sensible Cooling capacity (AS1861) Cooling power consumption (Input) Basic temperature condition cooling Basic temperature condition cooling PE-7MYC-EU PU-7MYC1-EU 17.9 14.3 7.2 kW kW kW Indoor Outdoor PE SERIES PE-8MYC-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU PU-8MYC1-EU PU-10MYC1-EU PU-15MYC1-EU PU-20MYC1-EU 57.6 47.0 22.0 28.8 46.1 37.6 17.6 23.0 7.8 10.1 22.0 17.4 27 DB/19 WB 35 DB [ ELECTRICAL ] <Indoor unit> Design voltage Cy cles Power supply Control voltage Voltage change Voltage change Fan motor output Fan motor current Volts 240 Hz Volts 1PH-240V Max. Min. 415 50 3PH-415V 240/24 Volts 240 415 Volts 220 380 HP(kW) 0.28(0.21) 0.94(0.70) 1.34(1.0) 2.95(2.2) Amps 3.2 1.2 2.0 3.5 4.96(3.7) 4.8 <Outdoor unit> Design voltage Cycles Power supply Voltage change Voltage change Fan motor output Fan motor current Max. Min. Volts Hz Volts Volts Volts HP(kW) 2×0.12(2×0.09) Amps 0.7 415 50 3PH-415V 415 380 0.32(0.24) 2×0.32(2×0.24) 2×0.2(2×0.15) 1.0 1.2 2×1.2 [COMPRESSOR] Make Model Type Number of compressor Nominal motor Locked rotor current Normal run current (AS1861) Swept volume Bore Stroke Speed Number of cylinders Oil charge Type of oil Crankcase heater MITSUBISHI JH519YE JH521YE JH527YE JH521YE JH527YE HERMETIC LINE START (RECIPROCATING) 1 2 HP(kW) 6.7(5.0) 7.4(5.5) 10.1(7.5) 7.4(5.5) 10.1(7.5) Amps 76 83 85 85 83 Amps 13.0 15.5 19.2 19.2 15.5 cc/rev 149 160.8 201 201 160.8 mm ø44.45 mm 24.0 25.9 rpm 2900 4 5 4 5 ml 3000 4500 3000 4500 DIAMOND MS32(N-1) OR SUNISO 3GS(D) watts 62 72 62 72 [REFRIGERATION SYSTEM] Refrigerant Refrigerant charge per circuit Number of refrigerant control Refrigerant control Limit of pipe’s length Limit of pipe’s height difference kg 5.7 m mtrs mtrs - 70 - 5.0 1 R22 8.7 4.8 9.7 2 Capillary tube 50 20 (In case of indoor unit above outdoor unit) 30 (In case of outdoor unit above indoor unit) Product number Indoor unit PE-7MYC-EU PU-7MYC1-EU Outdoor unit PE-8MYC-EU PU-8MYC1-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU PU-10MYC1-EU PU-15MYC1-EU PU-20MYC1-EU [INDOOR AIR CIRCUIT] Number of blowers Diameter of blowers Width of blowers Blower drive Fan motor output Fan motor run current Air quantity External static pressure Supply air dimensions(hxw) Return air dimensions(hxw) [EVAPORATOR] Number of evaporator Face area Rows deep Rows high Finned length Face velocity Fin per meter Fin material thickness Fin material/Type Tube diameter Gauge of copper tube Pipe type Number of circuit [OUTDOOR AIR CIRCUIT] Number of fans Diameter of fan Blower drive Quantity of motor Fan motor output Fan motor run current Air quantity [CONDENSER] Number of condensers Face area Rows deep Rows high Finned length Face velocity Fin per meter/Pitch Fin material thickness Fin material/Type Tube diameter/Gauge Pipe type Number of circuit 2 380 270 374 275 Direct drive Belt drive 3.7 2.2 1.00 0.70 0.21 4.8 3.5 2.0 1.2 3.2 3000 2333 1500 1167 1000 100/200 50/125 62/125 341× 1302 412×1000 412×1209 341 × 1102 248 × 998 596×1415 mm mm 250 245 kW A L/s Pa mm mm sq.m 1 0.50 0.42 4 0.86 1.00 4 24 15 1300 1615 1415 3.0 2.7 3.0 513/1.95 513/1.95 474/2.11 0.115 Aluminium / Ring 9.52 0.35 Plain tube Groove tube 10 16 24 mm m/s 1100 2.2 2.8 474/2.11 mm mm mm 1 2 mm 2 600 954 Direct drive 2 kW A L/s 2×0.09 0.7 3167 2×0.15 1.0 3000 3667 1 0.24 1.2 4000 2 2×0.36 2×1.2 8000 2 sq.m 2×2.1 1 30 mm m/s 32 2706 1.4 474 / 2.7 mm mm - 71 - 2 30 2696 1.5 625 / 1.6 538 / 1.86 0.115 Aluminium / Ring 9.52 / 0.35 Groove tube 7 11 1.32 2 40 1299 1.5 6.25/1.6 1.35 2 30 1775 3.0 Plain tube 6 Product number Indoor unit Outdoor unit PE-7MYC-EU PU-7MYC1-EU PE-8MYC-EU PU-8MYC1-EU PE-10MYC-EU PE-15MYC1-EU PE-20MYC-EU PU-10MYC1-EU PU-15MYC1-EU PU-20MYC1-EU [ENCLOSURE AND FRAME] Dimension Dimension Indoor unit Outdoor unit External finish (indoor unit) (outdoor unit) External finish Panel thickness Condense drain size Wei ght Indoor unit Wei ght Outdoor unit Sound pressure level (indoor unit) Sound pressure level (outdoor unit) Sound power level (indoor unit) Sound power level (outdoor unit) width depth height width depth height mm mm mm mm mm mm 1415 1615 650 428 1400 700 980 1690 1993 865 706 998 1996 998 1230 961 Galvanized steel Acrylic resin coationg (Color: Munsell 5Y8/1) 1.2 25.4 67 70 84 212 180 202 205 230 360 285 55 56 59 62 61 65 65 65 68 67 63 64 67 70 69 76 76 76 79 78 mm mm kg kg dbA dbA dbA dbA - 72 - PEH-5,7,8MYA-EU [ PRODUCT] Product type Product number : PACKAGE AIR COOLED HEATPUMP UNITS Indoor unit Outdoor unit Cooling capacity (AS1861) Sensible Cooling capacity (AS1861) Cooling power consumption (Input) Heating capacity (AS1861) Heating power consumption Basic temperature condition cooling Basic temperature condition cooling Basic temperature condition heating Basic temperature condition heating kW kW kW kW kW PEH-5MYA-EU PUH-5MYE1-EU 14.4 11.5 5.5 14.4 4.5 Indoor Outdoor Indoor Outdoor PEH SERIES PEH-7MYA-EU PEH-8MYA-EU PUH-7MYC2-EU PUH-8MYC2-EU PUH-8MYE1-EU 17.9 22.0 14.3 17.6 7.8 7.9 7.2 22.0 18.8 6.5 6.3 27 DB/19 WB 35 DB 21 DB 7 DB/6 WB [ ELECTRICAL ] <Indoor unit> Design voltage Cy cles Power supply Control voltage Voltage change Voltage change Fan motor output Fan motor current Volts Hz Volts Max. Min. Volts Volts HP(kW) Amps 415 240 415 50 3PH-415V 415 380 0.6(0.45) 1.1/1.0 1PH-240V 240/24 240 220 0.28(0.21) 3.2 3PH-415V 415 380 0.94(0.70) 1.2 <Outdoor unit> Design voltage Cycles Power supply Voltage change Voltage change Fan motor output Fan motor current Max. Min. Volts Hz Volts Volts Volts HP(kW) Amps 0.2(0.15) 1.0 415 50 3PH-415V 415 380 2×0.12(2×0.09) 0.7 0.47(0.35) [COMPRESSOR] Make Model Type Number of compressor Nominal motor Locked rotor current Normal run current (AS1861) Swept volume Bore Stroke Speed Number of cylinders Oil charge Type of oil Crankcase heater HP(kW) Amps Amps cc/rev mm mm rpm ml watts Copeland MITSUBISHI JH519YE CRNQ-0500-TFD JH521YE HERMETIC LINE START (RECIPROCATING) 1 5.0(3.73) 6.7(5.0) 7.4(5.5) 65 76 83 8.6 13.0 15.5 101.92 149 160.8 ø49.78 ø44.45 25.9 26.19 24.0 2900 2 4 1952 3000 DIAMOND MS32(N-1) OR SUNISO 3GS(D) CALUMET RO 15 OR WITCO 3GS 40 62 [REFRIGERATION SYSTEM] Refrigerant Refrigerant charge per circuit Number of refrigerant controls Refrigerant control Reverse cycle valve Defrost system Limit of pipe's leng th Limit of pipe's height difference R22 kg 6.6 1 Capillary tube 4-way valve Reverse cycle defrost 50 20 (In case of indoor unit above outdoor unit) 30 (In case of outdoor unit above indoor unit) 5.0 m mtrs mtrs - 73 - 5.7 Product number Indoor unit Outdoor unit PEH-5MYA-EU PUH-5MYE1-EU PEH-7MYA-EU PUH-7MYC2-EU PEH-8MYA-EU PUH-8MYC2-EU PUH-8MYE1-EU [INDOOR AIR CIRCUIT] Number of blowers Diameter of blowers Width of blowers Blower drive Fan motor output Fan motor run current Nominal air quantity External static pressure Supply air dimensions(hxw) Return air dimensions(hxw) [EVAPORATOR] Number of evaporator Face area Rows deep Rows high Finned length Face velocity Fin per meter / pitch Fin material thickness Fin material/Type Fin coating Tube diameter Gauge of copper tube Pipe type Number of circuit [OUTDOOR AIR CIRCUIT] Number of fans Diameter of fan Blower drive Quantity of motor Fan motor output Fan motor run current Nominal air quantity [CONDENSER] Number of condensers Face area Rows deep Rows high Finned length Face velocity Fin per meter/Pitch Fin material thickness Fin material/Type Tube diameter/Gauge Pipe type Number of circuit 1 mm mm 275 0.45 1.1/1.0 700 50/125 kW A L/s Pa mm mm 342×781 248×498 sq.m 0.3 2 250 245 Direct drive 0.21 3.2 1000 50/125 275 0.70 1.2 1167 62/125 341×1102 248×998 342×1118 1 0.42 4 15 780 2.5 513/1.95 mm m/s 15 1100 2.2 474/2.11 0.115 Aluminium / Ring NA 510 D *1 mm mm mm 9.52 0.35 Plain tube Groove tube 7 1 mm kW A L/s 1 0.35 1.2 1583 sq.m 1 1.3 mm m/s 1100 2.8 474/2.11 44 1000 1.56 513/1.95 mm mm 11 2 600 Direct drive 2 2×0.09 0.7 2783 2 2×2.1 2 30 2706 1.35 474 /2.11 0.115 Aluminium / Ring 9.52 / 0.35 Groove tube 7 Specifications subject to change without noice *1 Corrosion proof property : Salt spray JIS Z 2371, 500hrs Humiditiy test 50C 98% 500hrs. *2 Corrosion proof property : Salt spray JIS Z 2371, 1000hrs Humiditiy test 50C 98% 1000hrs. - 74 - Groove tube 10 1 800 1 0.35 1.2 3333 1 1.58 44 1400 1.95 513 /1.95 11 Product number Indoor unit Outdoor unit PEH-5MYA-EU PUH-5MYE1-EU PEH-7MYA-EU PUH-7MYC2-EU PE-8MYA-EU PUH-8MYC2-EU PUH-8MYE1-EU [ENCLOSURE AND FRAME] Dimension Indoor unit Dimension Outdoor unit External finish (indoor unit) (outdoor unit) External finish Panel thickness Condense drain size Weight Indoor unit Weight Outdoor unit Sound pressure level (indoor unit ) Sound pressure level (outdoor unit ) Sound power level (indoor unit ) Sound power level (outdoor unit ) width depth height width depth height mm mm mm mm mm mm mm mm kg kg dbA dbA dbA dbA - 75 - 1095 1415 650 428 1250 1000 1400 550 550 700 1175 1175 980 Galvanized steel Acrylic resin coationg (Color: Munsell 5Y8/1) 1.2 25.4 70 60 67 214 150 211 188 55 56 57 65 63 64 68 76 PEH-10,15,20MYA-EU [ PRODUCT] Product type Product number : PACKAGE AIR COOLED HEATPUMP UNITS PEH SERIES PEH-15MYA-EU PEH-10MYA-EU PUH-15MYC2-EU PUH-10MYC2-EU PUH-10MYE1-EU 44.0 28.8 35.2 23.0 10.1 10.2 16.9 28.8 44.0 8.3 14.1 27 DB/19 WB 35 DB 21 DB 7 DB/6 WB Indoor unit Outdoor unit Cooling capacity (AS1861) Sensible Cooling capacity (AS1861) Cooling power consumption (Input) Heating capacity (AS1861) Heating power consumption Basic temperature condition cooling Basic temperature condition cooling Basic temperature condition heating Basic temperature condition heating kW kW kW kW kW Indoor Outdoor Indoor Outdoor PEH-20MYA-EU PUH-20MYC2-EU 57.6 46.0 21.8 57.6 19.3 [ ELECTRICAL ] <Indoor unit> Design voltage Cy cles Power supply Control voltage Voltage change Voltage change Fan motor output Fan motor current Volts Hz Volts Max. Min. Volts Volts HP(kW) Amps 415 50 3PH-415V 240/24 415 380 1.34(1.0) 2.95(2.20) 2.0 4.1 1.34(1.0) 2.0 4.96(3.70) 4.7 <Outdoor unit> Design voltage Cycles Power supply Voltage change Voltage change Fan motor output Fan motor current Max. Min. Volts Hz Volts Volts Volts HP(kW) 2×0.2(2×0.15) Amps 1.0 415 50 3PH-415V 415 380 0.47(0.35) 1.2 2×0.47(2×0.35) 2×1.2 [COMPRESSOR] Make Model Type Number of compressor Nominal motor Locked rotor current Normal run current (AS1861) Swept volume Bore Stroke Speed Number of cylinders Oil charge Type of oil Crankcase heater HP(kW) Amps Amps cc/rev mm mm rpm ml watts MITSUBISHI JH527YE JH521YE JH527YE HERMETIC LINE START (RECIPROCATING) 1 2 10.1(7.5) 10.1(7.5) 7.4(5.5) 85 85 83 19.2 19.2 15.5 201 160.8 201 ø44.45 25.9 2900 5 4 5 4500 3000 4500 DIAMOND MS32(N-1) OR SUNISO 3GS(D) 72 62 72 [REFRIGERATION SYSTEM] Refrigerant Refrigerant charge per circuit Number of refrigerant controls Refrigerant control Reverse cycle valve Defrost system Limit of pipe's leng th Limit of pipe's height difference R22 kg 9.9 1 m mtrs mtrs - 76 - 6.6 9.7 2 Capillary tube 4-way valve Reverse cycle defrost 50 20 (In case of indoor unit above outdoor unit) 30 (In case of outdoor unit above indoor unit) Product number Indoor unit Outdoor unit PEH-15MYA-EU PUH-15MYC2-EU PEH-10MYA-EU PUH-10MYC2-EU PUH-10MYE1-EU PEH-20MYA-EU PUH-20MYC2-EU [INDOOR AIR CIRCUIT] Number of blowers Diameter of blowers Width of blowers Blower drive Fan motor output Fan motor run current Nominal air quantity External static pressure Suppl y air dimensions(hxw) Return air dimensions(hxw) [EVAPORATOR] Number of evaporator Face area Rows deep Rows hi gh Finned length Face velocit y Fin per meter / pitch Fin material thickness Fin material/Type Fin coating Tube diameter Gau ge of copper tube Pipe t ype Number of circuit [OUTDOOR AIR CIRCUIT] Number of fans Diameter of fan Blower drive Quantit y of motor Fan motor output Fan motor run current Nominal air quantity [CONDENSER] Number of condensers Face area Rows deep Rows high Finned length Face velocity Fin per meter/Pitch Fin material thickness Fin material/Type Tube diameter/Gauge Pipe type Number of circuit 2 mm mm kW A L/s Pa mm mm 250 275 Direct drive 1.00 1.00 2.0 1.8 1500 1500 62/125 341×1302 342×1318 248×998 sq.m 1 0.50 280 245 275 Belt drive 3.70 4.7 3000 2.20 4.5 2333 100/200 412×1000 412×1209 596×1415 2 0.86 0.98 4 15 1300 3.0 513/1.95 mm m/s 24 1415 2.7 513/1.95 1615 3.0 592/1.69 0.115 Aluminium / Ring NA 510 D *1 (NA 549 *2) mm mm mm 9.52 0.35 Groove tube 16 Plain tube 10 2 600 1 mm kW A L/s 2 2×0.15 1.0 3167 1 0.35 1.2 3333 sq.m 2 2×2.1 1 1.58 24 2 800 Direct drive 2 2×0.35 1.3 2X3083 2 2×1.32 2×1.07 3 mm m/s 30 2706 1.35 474/2.11 mm mm 11 44 1400 1.95 513/1.95 2.89 0.115 Aluminium / Ring 9.52 / 0.35 Groove tube 11 16 Specifications subject to change without noice *1 Corrosion proof property : Salt spray JIS Z 2371, 500hrs Humiditiy test 50˚C 98% 500hrs. *2 Corrosion proof property : Salt spray JIS Z 2371, 1000hrs Humiditiy test 50˚C 98% 1000hrs. (anti corrosion as special order) - 77 - 37 2800 2.34 474 /2.11 14 Product number Indoor unit Outdoor unit PEH-10MYA-EU PUH-10MYC2-EU PUH-10MYE1-EU PEH-15MYA-EU PUH-15MYC2-EU 1615 650 428 1690 PEH-20MYA-EU PUH-20MYC2-EU [ENCLOSURE AND FRAME] Dimension Indoor unit Dimension Outdoor unit External finish (indoor unit) (outdoor unit) External finish Panel thickness Condense drain size Weight Indoor unit Weight Outdoor unit Sound pressure level (indoor unit ) Sound pressure level (outdoor unit ) Sound power level (indoor unit ) Sound power level (outdoor unit ) width depth height width depth height mm mm mm mm mm mm 1250 550 1175 Galvanized steel Acrylic resin coationg (Color: Munsell 5Y8/1) 1.2 25.4 180 212 84 221 240 431 472 61 62 59 69 65 70 69 67 76 80 1400 700 980 mm mm kg kg dbA dbA dbA dbA - 78 - 1993 865 706 1951 1080 1200 INSTALLATION 1. Space required around unit Indoor unit Dimension of the unit and space necessary for sevicing. PE(H)-15,20 200 946 380 746 530 730 200 PEH-5 PE(H)-7, 8, 10 180 B 400 200 B A 500 500 928 1206 706 428 100 100 A Ceiling access panel PEH - 5 A B 1560 1000 PE(H) - 7, 8 1880 1320 PE(H) - 10 2080 1520 Ceiling access panel A B PE(H) - 15 2187 1587 PE(H) - 20 2490 1890 Outdoor unit Secure enough space necessary for servicing, installing, and for proper function of the unit. To prevent short-cycling, remove obstacles as much as possible. PUH-5, 8, 10 (Side blow) (1) At a single installation Service panel 150 over 500 over Inlet surface 150 over Inlet surface Inlet surface Service panel Inlet surface 150 over 300 over Outlet surface Outlet surface With the inlet surface facing a wall. With the outlet surface facing a wall. (2) Relation of unit when many set up unit. 300 over 500 over 500 over 500 over Please set the unit that the inlet air and the outlet air are not influenced. - 79 - 500 over PU(H)-7,8, 10 (Upper blow) (1) At a single installation 300 over The obstacle is on the outlet side. (Fig 1) The obstacle is in three directions. (Fig 2,3) The obstacle is in four directions. (Fig 4) ceiling 1200 over The right and left side and the back and forth side must be opened. 300 over 500 over However, the outlet side must be opened. Service Panel Fig 2 Fig 1 300 over A If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. 300 over A However, if the service panel is an interior side, the right or left side need 500 over. All “A” is 500 over. However, outlet side must be opened. And the obstacle in two directions must be lower than the unit. A A Fig 3 Fig 4 300 over (2) Relation of unit when many set up unit. (Fig 5,6,7) If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. 500 over A 300 over A A Fig 6 Fig 5 A A 300 over All “A” is 500 over. 300 over 500 over 500 over Service-panel A A Fig 7 A All “A” is 500 over in any case. - 80 - A Service-panel 300 over PU-15 (1) At a single installation The obstacle is on the outlet side. (Fig 1) The obstacle is in four directions. (Fig 2) 300 over ceiling However, the outlet 500 over side must be opened. 1500 over The right and left side and the back and forth side must be opened. 300 over 300 over Service Panel Fig 1 Fig 2 300over (2) Relation of unit when many set up unit. (Fig 3,4) 500over Service-panel 500 over 300 over If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. A A If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. A 300 over Fig 4 Service-panel All “A” is 500 over. Fig 3 PU-20 (1) At a single installation The obstacle is on the outlet side. (Fig 1) The obstacle is in four directions. (Fig 2) 300 over However, the outlet side must be opened. ceiling 500 over 1500 over 300 over 300 over The right and left side and the back and forth side must be opened. Service Panel Fig 2 Fig 1 300 over (2) Relation of unit when many set up unit. (Fig 3,4,5) 300 over Service-panel 300 over 500 over 500 over 300 over If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. A A A A Service-panel Fig 4 Fig 3 All “A” is 500 over. If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. 300 over A Fig 5 A A All “A” is 500 over in any case. - 81 - 300 over If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. PUH-15, 20 (1) At a single installation The obstacle is on the outlet side. (Fig 1) The obstacle is in four directions. (Fig 2) The obstacle is in three directions. (Fig 3,4) ceiling 1500 over 500 over The right and left side and the back and forth side must be opened. 300 over 300 over However, outlet side must be opened. And the obstacle in two directions must be lower than the unit. Service Panel Fig 2 Fig 1 However, the outlet side must be opened. 300 over Service-panel 300 over 300 over 500 over Service-panel Fig 3 Fig 4 300 over (2) Relation of unit when many set up unit. (Fig 5,6,7) Service-panel 300 over 500 over 500 over 300 over If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. A A A If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. A Service-panel Fig 6 Fig 5 All “A” is 500 over. If this side is service panel, you need 500 over. If this side is inlet, you need 300 over. 300 over A Fig 7 A A 300 over All “A” is 500 over in any case. 2. Preparation before installing Indoor unit Reinforcement Please use the specified hanging bolt in any case. Hanging bolt is local supply. Please use the method below or use the angle and the rectangular lumber, etc. and install the hanging bolt. Insert etc 100-150kg - 82 - Hanging bolt M10 (PEH-5,PE(H)-7,8,10) M12 (PE(H)-15,20) 3. Installation of the unit. Indoor unit Please carry the packed until parallelly to installed place. Please install the unit before construction of the ceiling -lined. PEH-5 PE(H)- 7, 8, 10 100 over 100 over U washer Nut 30 30 Washer Nut 100 over PE(H)-15, 20 Nut (M10) Nut (M10) Washer 30 Washer Nut (M10) Ceiling Nut (M10) Outdoor unit Fix unit tightly with bolts as shown below so that unit will be securely fixed in place use concrete or angle foundation of unit. At the time of bottom piping of refrigerant pipe, build a 100mm or higher foundation so that piping will go through bottom of unit. Anchor bolt (local arrangement) PUH-5 PU(H)-7, 8, 10 M8 PU(H)-15, 20 M10 Installation pitch Concrete foundation - 83 - Duct construction Provide canvas flexible ducting between unit when connect to the duct-work. The duct unit must use a nonflammable material. Provide sufficient insulation for prevent dewdrop. Duct earth Duct earth Canvas Duct Canvas Duct Duct Duct Drain pan Inlet Outlet Duct-work length 850mm or more Lifting method When the unit is to be lifted and moved, attach ropes to the suspension plates(3 p.c.s) provided on the top of the unit. When the unit is lifted, it 's center of gravity tends to shift the unit one side and so balance, such as that in the figure below, should be attained. The angles at which the ropes suspend the unit should be at least 60º at the compressor end and at least 45º at the condenser end. Care should be taken to avoid contact with the main unit while carrying. It is necessary to protect the unit with the blanket so that the ropes should not injure the unit. Hook (as directly aligned over the center of gravity as possible. MITSUBISHI ELECTRIC PUH-5,8,10 (side blow) PUH-7,8,10 (upper blow) - 84 - PUH-15,20 (PU-15,20 is same method.) Piping connection Warning Please follow the following procedures, during the piping connection work is carried out. If the procedures are not followed properly, the refrigerant and valve sheet might gush out from the ball valve. It might cause the injury. 1. PROCEDURE TO CONNECT THE EXTENSION PIPE Proceed with the connection as follows. (1) Open the ball valve cap at first. (Fig. 1) (2) Check the ball valve section is completely closed. (Fig. 2) Valve knob Fig. 1 Valve knob Close Open Pin Pin Fig. 3 Fig. 2 (3) Remove the connection pipe assy. (Fig. 4) Throw away the packing. (Except the PUH-5) Caution: There will be small amount of refrigerant gushed out of the by-pass tube at the moment. Loosen and tighten the flare nut using a double-ended wrench. (Fig. 7 and Table. 1) Coat the flare contact surface and both surface of packing with refrigerator oil. Do not brazing work before removing the connection pipe assy. (Except the PUH-5) (4) Remove the by-pass tube. (Except the PUH-5) (Fig. 5) Braze the extension pipe with the flange assy. (Except the PUH-5) (5) Connect the extension pipes with the ball valves (the flare nut type). (Only the PUH-5) (Fig. 6) Connect the extension pipes with the ball valves (the flare nut and the flange type). (Fig. 6) Use the attached new packing certainly between the ball valve and the flange. Connection Pipe assy Unit side Unit side Extension pipe PUH-5 Connection Pipe assy Unit side Unit side By-pass tube Extension pipe PU(H) 8-20 Flange assy Extension pipe Packing (throw away) Fig. 4 Fig. 5 use the attached new packing Fig. 6 2. HANDLING PRECAUTIONS (1) The extension pipes should be connected under closing condition. (Fig. 2) Do leak test the part of flange and flare. (2) Before charging the refrigerant, vacuum the extension pipes and indoor side to clear all the air and water. (3) Charge the additional amount of refrigerant according to the installation manual. Fig. 7 (4) Do leak test again. (5) Turn the ball valve knob to “Open” position. (Fig. 3) pipe diameter Tightening torque (6) Finally, put the cap back to the ball valve. (mm) (Nm) / (kgcm) 6.35 9.52 12.7 15.88 19.05 14 to 18 / 140 to 180 35 to 42 / 350 to 420 50 to 57.5 / 500 to 575 75 to 80 / 750 to 800 100 to 140/1000 to1400 Table. 1 - 85 - 4. Refrigerant piping Extension piping and installation parts are field supply. C Perform the work only after carefully reading the appropriate instructions. A Install the unit where the refrigerant piping is shortest, When the outdoor unit is lower the difference between the indoor unit and outdoor unit is smallest. As pipes purchased in the market may contain dust, below them off with dry inlet gas. C Take care not to allow dust and water content to enter the piping during pipe processing or installing. Minimize the number of bends, and make the bending B radius as long as possible. Always observe the restriction(allowable length, height difference, pipe diameter) on the refrigerant piping. When the outdoor unit is higher For soldering & brazing, use high-quality materials. Never purge air with a refrigerant. Always use a vacuum pump for purging. Provide proper insulation to the piping . Insufficient insulation cause poor cooling/heating performance or condensation drip, leading to unexpected trouble. Do not insulate gas or low pressure pipe and liquid or high pressure pipe together. For the connection of the refrigerant piping, leave the valve of the outdoor unit fully closed (as set before shipment), and no operate it until the connection between the indoor/outdoor units and refrigerant piping, refrigerant leak test and evacuation work have been completed. The maximum permissible values are shown below. Remove the cover (grommet) attached sheet metal at exit of heat exchanger pipe of indoor unit before connecting the local piping. (This cover is protect the pipe from sheet metal edge at unit transportation.) Please insulate liquid pipe & gas pipe (two places for each) with an insulated pipe of the attachment after connecting piping. Bad example Good example Insulating material Finishing tape Insulating material Finishing tape Liquid pipe Liquid pipe Gas pipe Gas pipe Electric wire PEH-5 Electric wire PE(H)-7 PE(H)-8 PE(H)-10 PE(H)-15 PE(H)-20 Dimension A (m) 20 20 20 20 20 20 Dimension B (m) 30 30 30 30 30 30 Number of bends 15 15 15 15 15 15 Total piping length (m) 50 50 50 50 50 50 12.7 15.88 15.88 15.88 19.05 25.4 25.4 28.6 Piping Liquid pipe (mm) size Gas pipe (mm) - 86 - 2×15.88 2×15.88 2×25.4 2×28.6 Airtight test Airtight test should be made by pressurizing nitrogen gas to 3Mpa. For the test method, refer to the following figure. (Make a test with the valve closed. Be also sure to pressurize both liquid and gas pipe.) The test result can be judged good if the pressure has not been reduced after leaving for about one day after completion of nitrogen pressurization. a. Nitrogen gas b. To indoor unit c. System analyzer d. Low knob e. High knob f. g. Valve Liquid gas h. Gas pipe i. j. Outdoor unit f g b i h c e d a j Service port Evacuation Evacuation should be made from the service port provided on the outdoor unit's valve to the vacuum pump commonly used for both liquid pipe and gas pipe. (Make evacuation from both liquid pipe and gas pipe with valve closed.) Remember :Never carry out air purge by refrigerant. a. System analyzer b. To indoor unit c. Low knob d. High knob e. Valve Liquid gas f. g. e b f h g a c d Gas pipe h. Outdoor unit i. j. Vacuum pump i j Service port Additional refrigerant charge The mount of refrigerant charged in this unit is a appropriate for 5-meter long refrigerant pipes. Refer to the table below and add the corresponding amount of refrigerant if the pipes are extended. (The refrigerant is charged in the outdoor unit.) The outdoor unit of PE-5,8,10 have side blow type and upper blow type. Factory charge refer to the table below. Factory charge Refrigerant piping length unit PU-7 PU-8 PU-10 charge PU-15 mount PU-20 R-22 (kg) PUH-5 PUH-7 PUH-8 PUH-10 PUH-15 PUH-20 5m Outdoor unit 10m 15m 20m 25m 30m 35m 40m 45m 50m Side blow 0 0 0.8 1.6 2.4 3.2 4.0 4.8 5.6 6.4 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0 0.8 1.6 2.4 3.2 4.0 4.8 5.6 6.4 7.2 0 0.8 1.7 2.5 3.3 4.2 5.0 5.8 6.7 7.5 0 2×0.8 2×1.7 2×2.5 2×3.3 2×4.2 2×5.0 2×5.8 2×6.7 2×7.5 - 87 - PU-7 PU-8 7.2 2×0.8 2×1.6 2×2.4 2×3.2 2×4.0 2×4.8 2×5.6 2×6.4 2×7.2 Upper blow charge mount R-22 (kg) PUH-5 PUH-8 PUH-10 5.7 5.0 PU-10 8.7 PU-15 PU-20 2×4.8 2×9.7 5.0 6.6 9.9 PUH-7 5.7 PUH-8 PUH-10 PUH-15 6.6 11.0 2×6.6 PUH-20 2×9.7 5. Drain piping •Incline the drain piping to the outside (drain side) as shown in the figure below. •The outlet of the indoor unit drain pipe is Rc1. •After completion of piping, confirm that drainage is good and that there are no leaks. Indoor unit drain piping Install thermal insulation to prevent dew The drain piping should have a drain trap. C Slope 20mm/m A Drain pan Drain piping B A> = 70mm B> = 2×C > = 70mm C> = 35mm Drain trap The drain pipe should extend below this level. - 88 - Open drain 6. Electric wiring Construct the earth connection. All electrical work must be carried out by a suitable qualified electrical trades-person and in accordance with local supply authority requirements and associated regulators. The range of working voltage is within 10% voltage of power supply. The outdoor unit is to be wired directly from an electrical distribution board either by a circuit breaker (preferred) or HRC fuse. Fix power source wiring to control box by using buffer bushing for tensible force (PG connection or the like). Connect control wiring to control terminal block through the knockout hole of control box using ordinary bushing. Note: Earth wiring must be connected. Arrangement such as terminal block in control box Control module of indoor unit PEH-5, PE(H)-7, 8,10 Control module of indoor unit PE(H)-15, 20 PE(H)-7 only Terminal block for connection wires to Outdoor unit and remote controller PEH-15, 20 only 30FZ F1(3.15A) Terminal block for connection wires to Outdoor unit and remote controller F2(3.15A) F2(3.15A) TB3 11 12 13 14 1 2 3 4 5 6 30FZ Tr PEH only 52F,51F1 Terminal block for power supply wires Terminal block for power supply wires FZ TB2 HZ1 L CZ1 CZ1-1 F1(3.15A) IN CASE OF G03 CZ1-2 HZ1-1 PEH-15, 20 52F&51F1 PE-15, 20 52F1&51F1 52F&51F HZ1-2 PEH-15, 20 HZ1-1 PE-15, 20 FZ TB2 L1 N Tr FZ C L2 L3 N PEH-15,20 only Screw for earth connection Bush and band for the power supply Bush for the thermistor Screw for earth connection Bush and band for the power supply Bush and band for the connection wires to Outdoor unit and remote controller Bush and band for the connection wires to Outdoor unit and remote controller Control module of outdoor unit (PUH-5, 8, 10) Side blow T1 T2 F3 Screw for earth connection 51F2 26D X2 30CZ CZ2 HZ2 F3 3.15A 52C & 51C X1 TB5&6 TB1 Terminal block for power supply wires Terminal block for connection wires to Indoor unit Bush for the thermistor Band for wires - 89 - Control module of outdoor unit PU-15 Control module of outdoor unit PU(H)-7, 8, 10 Upper blow In case of PU-7, 8, 10 In case of PUH-7, 8, 10 Terminal block for power supply wires F3 F3 52C & 51C F3 3.15A F3 3.15A 52C & 51C F3 2 52C1 & 51C1 T1 F3 3.15A 52C2 & 51C2 TB1 L1 51F2 Terminal block for connection wires to Indoor unit 51F2 L2 L3 30CZ1 30CZ2 CZ CZ 2-1 2-2 N TB4&5 11 X1 X2 12 13 N N 30CZ 26D Screw for earth connection TB1 L1 L2 L3 Screw for earth connection N Band for wires TB1 Terminal block for connection wires to Indoor unit Band for wires Screw for earth connection Terminal block for power supply wires Terminal block for power supply wires Control module of outdoor unit PU-20 Control module of outdoor unit PUH-15,20 52F2 & 51F2 52C2 & 51C2 Screw for earth connection 51F3 52C1 & 51C1 51F2 52C2 & 51C2 T1 T2 2 T3 X3 X4 T4 F3 51F3 52C1 & 51C1 2 30CZ1 30CZ2 26D1 26D2 F3(3.15A) X1 TB1 L1 Screw for earth connection CZ2-1 CZ2-2 TB4&5 111213 N N F3 TB1 L1 Terminal block for power supply wires L2 L3 N L2 L3 X2 30CZ1 30CZ2 TB4&5 N 11121314 N N N N FC CZ 2-1 CZ HZ2 2-2 Terminal block for connection wires to Indoor unit F3(3.15A) Terminal block for power supply wires Band for wires - 90 - Band for wires Terminal block for connection wires to Indoor unit Method for connecting electric wire Please do the wiring after consulting the electric power company of jurisdiction beforehand in the instruction. (1) The entire wiring diagram of unit. a a b b PE PE j d c j In case of PE-7,8,10 In case of PE-15,20 PEH-5, 7, 8, 10 g a. Power supply b. Main switch/fuse (field supply) c. Power supply wiring for outdoor unit d. Power supply wiring for indoor unit e. Outdoor unit f. Indoor unit g. Connection wiring for indoor / outdoor units (polarity) h. LCD remote controller i. Connection wiring for indoor / remote controller (no polarity) j. Earth In case of PEH-15,20 e i In case of PE-7, 8, 10 f In case of PE-15, 20 PEH-5, 7, 8, 10 h In case of PEH-15, 20 (2) Power supply construction and electric wiring connection of indoor and outdoor unit. In case of PEH-5 PE(H)-7,8,10 B A 3phase PE(H)-7:Single phase PEH-5 PE(H)-7,8,10 PE(H)-15,20 G H L1 L2 L3 N PE 13 14 15A 15A 30A In case of PE(H)-15,20 H 15 11 12 13 14 C C PEH only PEH only D 3 phase PUH-5 PU(H)-7,8 PU(H)-10 PU(H)-15 PU(H)-20 50A 50A 60A 100A 125A E L1 L2 L3 N PE 13 14 G H F A. Indoor unit B. Power cable wiring C. Control cable wiring (Fixing wire-- Do not remove) D. Outdoor unit E. Earth leakage breaker (with over-load pretection) F. Fuse G. Power supply terminal bed H. Control cable terminal bed - 91 - 15 11 12 H 13 14 (3) LCD remote controller. (3)-1. Confirmation of parts The following parts are contained in the carton box together with this manual. Please check to make sure that everything is included. Q'TY 1 Remote controller (upper case, lower case) ······································· 1 2 Pan-head screw with cross hole M4 ··················································· 2 3 Wooden screw 4.1 ✕ 16 (for installing unit directly on a wall) ············· 2 4 Instruction manual ················································································ 1 (3)-2. Outline and inside drawing Refer to (3)-5 Refer to (3)-4 INT / EXT JH 1 2 3 4 ON DIP SW 24VAC(N) 24VAC(L) COMP2 FAN HI COMP1 FAN LO 4W V TB1 ERROR EXT TB2 SENSOR Outline (Key cover open) Controller board (3)-3. Installation (1) Decide where you want to install the LCD remote controller (switch box) In deciding, please observe the following precautions: Do not install the LCD remote controller in locations, which are: Exposed to direct sunlight. Susceptible to humidity and moisture. Near a source of heat. Near machines emitting high-frequency waves. (High-frequency welders, etc.) 1) Procure the following parts locally : Switch box for two units Connecting wire (Length : below 20m size : 0.75mm2) Lock nut, bushing (2) Install the lower case on the switch box. Connecting wire Pan-head screws with cross holes Switch box for two units Connect to terminal When installing on switch box Seal the wire lead-in hole completely with putty Caution : Over-tightening the screws can cause deformation and / or cracks on the lower case. Install the LCD remote controller on a wall with flat surface. Installation on an uneven surface can cause cracks on the LCD and other failure. Snap the upper case into place. Hook the two upper claws into their slots, and shut the lower part as shown in the right diagram. Caution : Press the case until it snaps shut. To use, remove the protective sheet on the operation section. To remove the upper case, insert a screwdriver(-) into one of the slots and slide it in the direction of the arrow shown in the diagram on the right. Caution : Do not turn the screwdriver while it is inserted into the slot. Doing so can result in damage to the slot. - 92 - Refer to (3)-3 (3)-4. Wiring (1) Connect the wires on the basis of the following wiring diagram. (2) Connecting work is different each models. (3) LCD remote controller cables must be installed away from the power cables so that they are not influenced by electrical noise from the power cables. (Do not place the LCD remote controller cables and power cables in the same conduit.) Caution : This controller is damaged if mistook the connection. PE-15,20 2 TB4 3 C03 3 3 FZ CZ1 3 GRAY 5 PEH-15,20 2 CZ1 C03 3 4 FZ 3 GRAY 3 FAN HI 4WV AC 24V Tr PAC-204RC COMP2 FAN HI 3 HZ TB3 1 F2 (3.15A) C03 C04 1 1 24VAC(N) 24VAC(L) TB4 3 C03 1 PAC-204RC COMP1 24VAC(N) AC 24V Tr GRAY TB4 1 F2 (3.15A) C03 C04 1 1 4WV GRAY 3 4 FZ GRAY PEH-5,7,8,10 C03 3 FAN HI 24VAC(L) 3 TB3 2 CZ CZ 1-1 1-2 3 4 C03 1 PAC-204RC COMP2 COMP1 AC 24V Tr 24VAC(L) 3 TB3 1 F2 (3.15A) C03 C04 1 1 COMP1 C03 3 C03 1 PAC-204RC COMP1 AC 24V Tr 24VAC(L) F2 (3.15A) C03 C04 1 1 24VAC(N) C03 1 GRAY TB4 1 FAN HI GRAY 24VAC(N) PE-7,8,10 3 4 5 TB3 2 CZ CZ HZ1 FZ 1-1 1-2 GRAY 5 6 (3)-5. Setting DIP switch Set the DIP switches on the basis of the below table. DIP Switch 1 OFF ON DIP Switch 2 ON OFF DIP Switch 3 ON OFF DIP Switch 4 ON OFF Factory pre setting PE setting PEH setting FUNCTION Mode select Fan speed Hi / Lo (*1) (Not change) (Change) Heat pump (Not change) (Not change) (*2) (Not change) (*3) (*3) Cooling only Do not change DIP switch 2. Auto chang over function (*2) Available Auto start at Power failure (*3) Not Available Not Available Automatically Note. *1: This function can not use at above models, because the fan speed of these models is constant. *2: If need this function, please consult your local MITSUBISHI ELECTRIC SALES office for application advice on this function. *3: This function can change by customer self. If this function use, The unit will auto start at power supply come back after power failure. - 93 - (3)-5. How to connect the external sensor (PAC-SE40TSA) to LCD remote controller. This controller is set for using internal sensor. If you need the external sensor, please consult your dealer and purchase option external sensor. (PAC-SE40TSA) And please change below method. Shunt jumper Shunt jumper 1. Remove the cover of LCD remote controller. 2. Connect the wire of external sensor to terminal as below. 3. Replace the shunt jumper from "INT" side to "EXT" side as below. Section A 4. Check above connection. (Refer to PAC-SE40TSA Installation manual.) Replace JH (Shunt jumper) from INT side to EXT side. 5. Attach the cover of LCD remote controller. Printed board INT / EXT JH COMP2 COMP1 4W V ERROR 24VAC (N) 24VAC (L) FAN HI FAN LO Detail section A EXT SENSOR Cover Wiring of external sensor Wiring of LCD remote controller LCD remote controller inside Wiring of LCD remote controller Wiring external sensor External sensor PAC-SE40TSA (4) Wiring example (For metal piping) Breaker capacity Power cable Over current protection switch Earth cable 2.0mm 15A 15A 2.0mm over 2.0mm 2 15A 15A 2.0mm over 2.0mm 2 15A 15A PE(H) -10 2.0mm 2 15A 15A PEH - 5 PE(H) - 7 Control wiring 2 2 2 PE(H) -15 2.0mm 2 30A 30A 2.0mm over Cable or wire of 2 2 2.0mm over 0.75mm (24VDC) 2 2.0mm over PE(H) -20 2.0mm 2 30A 30A 2.0mm over PUH - 5 8mm 2 50A 50A 8mm over 8mm 2 50A 50A 8mm 2 50A 50A 60A 60A The grounding wire must be of the same Cable or diameter as the power cable wires. wire of 2 0.75mm Table above is an example. 2 14mm over (24VDC) The selection of other capacities should be 2 determined in accordance with the relevant 14mm over standards. 2 22mm over PE(H) - 8 PU(H) - 7 PU(H) - 8 PU(H) -10 14mm 2 14mm 2 100A 100A PU(H) -20 22mm 2 125A 125A PU(H) -15 2 2 2 2 8mm over 2 8mm over (5) Selecting earth leakage breaker (NV) To select NF or NV instead of a combination of Class B fuse switch use the following. In the case of Class B fuse rated 15A. Fuse (class B) Earth leakage breaker (with over-load protection) PEH - 5 15A NV30-CA 15A 30mA 0.1s or less PE(H) - 7 15A NV30-CA 15A 30mA 0.1s or less PE(H) - 8 15A NV30-CA 15A 30mA 0.1s or less PE(H) - 10 15A NV30-CA 15A 30mA 0.1s or less PE(H) -15 PE(H) -20 30A 30A NV50-CP NV50-CP 30A 30A 30mA 0.1s or less 30mA 0.1s or less PUH - 5 50A NV50-CA 50A 100mA 0.1s or less PU(H) - 7 PU(H) - 8 50A 50A NV50-CA NV50-CA 50A 50A 100mA 0.1s or less 100mA 0.1s or less PU(H) - 10 60A NV60-CA 60A 100mA 0.1s or less PU(H) - 15 PU(H) - 20 100A 125A NV100-CP 100A 100mA 0.1s or less NV225-CP 125A 100mA 0.1s or less - 94 - NV is a product of MITSUBISHI ELECTRIC. Table above is an example. The selection of other capacities should be determined in accordance with the relevant standards. Note. All electrical wiring must be comply with local electrical authority regulations. 7. The putting condition of the belt (PE(H)-15,20 only) 1. Set the parallel angle of the fan and the motor pulley as shown in the table and figure 1 below. 2. Set the tension of the per one belt when the flexion load is within the range as shown in the figure 1 below at the proper flexion. (A=4.5mm) 3. Adjust the suitable tension after the belt sit properly across the pulley (after more 24-28 hours working). When the new belt is used, adjust the suitable tension about the 1.3 times of the maximum value of the flexion load. 4. Readjust the belt every 2,000 hours after the first adjustment. Exchange the belt when the belt's surroundings length has expanded by 2% including the first expansion of the belt. (about 1%) (about 8,000 hours converted working time) table parallel angle pulley pulley K( ) note 10 or less gap of 3mm every 1m K Flexion load(W) 1.4 2.2kg K K A A=4.5mm K K Figure1 Parallel degree of pulley Figure2 Belt tension 8. Before starting the Trial run Check items (1) Check to see wheter there are refrigerant leakage, and slack power or transmission cable. (2) Conform that 500V megohmmeter shows 1.0M ohm or more between power supply terminal and ground. (3) Do not operate in the case of 1.0M ohm or less. Note : Never carry out megger-ohm check over terminal control board. Otherwise the control board would be broken. (4) Check to see wheter both gas and liquid valves are fully opened. Note : Be sure to tighten caps. (5) Turn universal power supply at least 6 hours before gettig test run in order to current to crank heater. If current-carrying hours are too short, it may result in a malfunction of compressor. (6) Confirm operation of high-pressure switch. If the two lead wires of the outdoor unit fan motor are disconnected from the connector and cooling is performed, the high-pressure switch should operate and stop the unit after 5 to 10 minutes. (7) Confirm that the fans of the indoor and outdoor unit rotate in the correct direction. Change the power supply phase connections if it is rotating in the reverse direction. Perform trial operation after completion of the above items. - 95 - INSTRUCTIONS FOR USE 1. Check points for operation Check the following points before you operate your air conditioner. (1)Check that there is nothing blocking the flow of air from the air outlet into the air inlet. Indoor unit Inlet grille Outlet grille Ceiling Ceiling Obstacle blocking air inlet Obstacle blocking air outlet Outdoor unit Obstacle blocking air inlet. (2)Make sure the air conditioner is properly grounded by checking the ground terminal. Ground - 96 - 2. Caution for use Keep the following points in mind to safeguard against failures and breakdowns. (1) This air conditioner does not restart within 3min. after shut down.(These models have a crankcase heater in the compressor. If the air conditioner is shut down for a short time, please do not turn the power switch to OFF, but turn the operation switch to OFF.) (2) If the air conditioner is shut down by a power failure, set the operation switch to OFF. When the poweris estored, normal air conditioner operation can be resumed. (3) Do not insert a finger or rod into the air outlet and inlet. It can cause injury as the fan inside is rotating at high speed. 3 Minutes Operation Shutdown 3. Maintenance For superior performance and lasting durability, please do not forget to conduct proper and regular maintenance Warning . 1.Do not wash the unit with water. If washed with water, electrical shock may be caused. 2.Ahead of the maintenance. For safety, turn the power source off before service work. 3.1 Cleaning the Air Filter Clean the air filter about once a week with a neutral cleanser and leave it to dry in a shady location. Clean more regularly if the air filter gets very dirty. If the filter gets blocked, air will not be sucked in properly, and the cooling effect will deteriorate. Failure to clean the air filter may result in equipment breakdown or malfunctions. 1. Removing the air filter. 2. The air filter is cleaned with the cleaner or washed in clear water. When the filter is dirty, please wash it with lukewarm water and some neutral detergent is recommended. Please do not use a hot water of 50˚C or more. (It transforms occasionally.) It is necessary to avoid massage washing and squeeze strongly. It must rinse enough and the detergent must not remain. 3. When the filter is washed in clear water, it is often dried in the shade. Please do not dry it to direct sunshine and a direct fire. Shaded location Neutral Cleanser 4. The air filter is installed as before. 3.2 Cleaning panels Clean dirt off front panel as follows. Use a household neutral cleanser such as for dishes or vegetables. Moisten a soft cloth with the cleanser, then wipe lightly. Next,wipe three or four times with another soft cloth moisten with water. Finally, wipe off all the remaining cleanser with a soft cloth. Moisten a soft cloth with the alcohol, then wipe off lightly. Isopropyl alcohol is sold at stores as reagents in small quantities. Note: Alcohol is highly combustible. Take extreme care when handling. Also, do not use paint or adhesive thinner. - 97 - Fingermarks Grease Adhesive Paste Neutral Cleanser Isopropyl alcohol 3.3 Cleaning the Outdoor Unit Heat Exchanger If you use your air conditioner for prolonged periods, the outdoor heat exchanger will become dirty, impairing its function and reducing air conditioners performance. Consult your equipment supplier or air conditioning contractor on how to clean the heat exchanger. Heat exchanger 4. The putting adjustment of the belt (PE(H)-15,20 only) The tension of the belt decrease with the passage of the drive time by total length's expands. Under such a condition, it occasionally causes the breakdown by a strange wear and an abnormal sound if it keeps driving. Please have seeing installed manual or consult your dealer about details of the adjustment of V pulley. Adjustment time 4.5mm First time: 24 ~ 28 hours later Since the second times: Every 2000 hours later Exchange: Every 8000 hours later V pulley Flexion load (W) 1.4 kg 2.2kg 5. When beginning to use air conditioner again Please turn on the power supply after confirming an following check is done and abnormality is not found. It is confirmed that air inlet and outlet are not blocked. It is confirmed that the earth connection line does not come off. The earth connection line is installed surely in the unit. It is confirmed that there are neither lifting, blocking, no bending about the drain-hose. Please do the following work. 1. It is confirmed to keep the controller OFF. 2. The power supply switch is turned on. Keep the power switch ON for more than 6 hours before starting operation. Do not turn the power supply OFF during seasons of heavy use, doing so can result in failure. 6. When the air conditioner is not to be used for long time If the air conditioner is not to be used for a long time due to a seasonal change, etc., Please do the following work. 1. The power supply switch is turned off. If the power supply is kept on, several watts or several tends of watts will be wasted. Also, the accumulation of dust, etc., can result in fire. 2. Filter and drain pan are cleaned. Pay attention to throw dust in the drain. 3. Run it for 4-5 hours with the air blowing until the inside is completely dry. Failing to do so can result the growth of unhygienic, unhealthy mold in scattered areas throughout the room. 7. In case of failure 1. Never remodel the air conditioner. Consult your dealer for any repair service. Improper repair work can result in water leakage, electric shock, fire, etc. 2. If the poser breaker is frequently activated, get in touch with your dealer. Leaving the unit as it is under such conditions can result in fire or failure. 3. If the refrigeration gas blows out or leaks, stop the operation of the air conditioner. 4. Thoroughly ventilate the room, and contact your dealer. Leaving the unit as it is can result in accidents due to oxygen deficiency. - 98 - 8. Transferring work, and construction 8.1 Transfer of installation 1. When removing and reinstalling the air conditioner when you enlarge your home, remodel, or move, consult with your dealer in advance to ascertain the cost of the professional engineering work required for transferring the installation. 2. Please do not mix the one other than a specified refrigerant when you add the refrigerant (R-22) at the installation and the transferring. 3. When moving or reinstalling the air conditioner, consult with your dealer. Defective installation can result in electric shock, fire, etc. 8.2 Place for installation. Please do not use the unit in the following places. 1. Place where a lot of oil (The machine oil is contained), moistures, and dust exist. 2. Place where a lot of salinities such as beach districts exists. 3. Place where sulfur gas, volatile gas, and corroded gas are filled. 4. Place where acid solution is frequently used. 5. Place where special spray is frequently used. 6. Hot spring zone. 7. Never machine (high cycle welding machine etc.) generating high cycle. 8. Place where ventilation entrance of outdoor unit is closed by snowfall. 9. The unit must be installed on stable, level surface. The main body might corrode when the unit is used in such a place, the refrigerant leak, the performance of the unit decrease remarkably, and it cause the damage of parts of the unit. 8.3 Regarding electric work 1. The electrical work must be undertaken by a person who is qualified as an electric engineer according to the (technical standard respecting electrical installation), (internal wiring rules), the installation and operation manual with the absolute use of exclusive circuits. The range of working voltage is within ±10% voltage of power supply. 2. Please install a special power supply in the power supply. 3. Please install the earth connection for the electric shock prevention. 4. Never connect the grounding wire to a gas pipe, water pipe, arrester, or telephone grounding wires. For details, consult with your dealer. 5. In some types of installation sites, the installation of an earth leakage breaker is mandatory. For details, consult with your dealer. 6. The breaker and the fuse must use the one of correct capacity. 8.4 Consideration of the noise 1. Take sufficient measures against noise when installing the air conditioners at hospitals or communication-related businesses. 2. If the air conditioner is used in any of the above-mentioned environments, frequent operational failure can be excepted. It is advisable to avoid these type of installation sites. For further details, consult with your dealer. 3. Choose a place where cool or warm air and noise from the outdoor air outlet of the air conditioner do not inconvenience the neighbours. 4. If any obstruction is placed near the air outlet of the unit, decreased performance and increased noise can result. Do not place any obstruction near the air outlet. 5. If the air conditioner produces any abnormal sound, consult with your dealer. 8.5 Disposing of the unit When you need to dispose of the unit, consult your dealer. If pipes are removed incorrectly, refrigerant (fluorocarbon gas) may blow out and come into contact with your skin, causing injury. Releasing refrigerant into the atmosphere also damages the environments. 8.6 Maintenance and inspection 1. If the air conditioner is used throughout several seasons, the insides can get dirty, reducing the performance. 2. Depending upon the conditions of usage, foul odours can be generated and drainage can deteriorate due to dust and dirt, etc. - 99 - 9. Troubleshooting Before you ask for repair service, check the following points: State of Machine It does not run. Cause LCD remote controller “ON-OFF” display is not lit up. No display appears even when the [ON/ OFF] button is pressed. Troubleshooting Power failure. Press the [ON/OFF] button after power restoration. The power supply is turned OFF. Turn the power supply ON. The fuse in the power supply is gone. Replace fuse. The earth leakage breaker is gone. Put in the earth leakage breaker. The wiring phase of power supply is mistaken. Modify the wiring phase of power supply. Air flows out but it does not cool or heat enough. The liquid crystal display shows that it is in the state of operation. Improper temperature adjustment. After checking the set temperature and inlet temperature on the liquid crystal display, refer to [To change room temperature] on page 7, and operate the adjustment button. The filter is filled with dust and dirt. Clean up the filter. There are some obstacles at the air inlet and outlet of the units. Remove. Windows and doors are open. Close. Insufficient refrigerant charge. Contact with your installing contractor. Cool or warm air does not come out. The liquid crystal display shows that it is in operation. The restart-preventing circuit is in operation for Wait for a while. 3 minutes. (To protect the compressor, a 3-minute restartpreventing circuit is built into the unit. Therefore, there are occasions sometimes when the compressor does not start running immediately. There are cases when it does not run for as long as 3 minutes.) Can not change to Heat mode. (PEH only) Can not change to Heat mode when press the “MODE” key. DIP switch 1 is not correct. Change the DIP switch off to on. (Refer to Installation manual.) On heating, cool air comes out. (PEH only) Indoor unit operation shift to defrost. Wait for a while. (Heating operation starts after ending defrosting operation.) Fan runs but compressor do not run. The set temperature of thermostat is excessively high for cooling. excessively low for heating. (PEH only) For temperature control, decrease the set temperature at cooling. increase the set temperature at heating. (PEH only) The room temperature is excessively low for cooling. excessively high for heating. (PEH only) Can not be operated as it is out of temperature control range. Fan runs but stops immediately. Air outlet and inlet are blocked. Remove blocking matter. Fogged white steam is discharged from the indoor unit. When the indoor temperature and humidity are high, such a phenomenon is occasionally had at the beginning of system operation. It is not a breakdown. Please use as it is. Water or steam is discharged from the outdoor unit. At cooling, water which places to cooling piping and piping connection part drops. When heating, water which places to the heat exchanger drops. (PEH only) It is not a breakdown. Please contact and consult your dealer. The drain pipe is clogged due to dust, therefore the drain water overflow. On heating, the air flow stops although a set temperature is not reached. (PEH only) Frost adheres to the outdoor coil when the temperature on the outside is low and humidity is high. This frost is melted. It is not a breakdown. Please use as it is. LCD remote controller error display Indicate Cause Troubleshooting E01 Room temperature sensor open. Automatically reset to restoration error. E02 Room temperature sensor short. Automatically reset to restoration error. E03 Error input from Indoor unit or Outdoor unit. Push the On-Off switch. (OFF to ON) - 100 - HOW TO OPERATE If you use the LCD remote controller, you can operate below method. Please consult operate method with dealer, if you use field supply control parts. Display section C 1. ON / OFF G B E H D F A J 1 E E Operation lamp Start an operation Press the [ON/OFF] button 1 Operation lamp lights up and operation starts. For purposes of explanation, all the displays on this page are shown in their lit condition. This configuration does not occur in the actual unit. Before starting operation * Make sure that the power supply is turned ON before use. (Keep the power supply turned ON at all times when the air conditioner is in use. Use of the unit without power can result in compressor failure.) Stop an operation Press the [ON/OFF] button A [Current/start/ending time] Display B Operation mode Displays the status of operation. C [Checking] Display This displays indication when some abnormality occurs in the unit. D [Set temperature] Display Displays the set temperature. E [Operation] Lamp Lights up during operation, goes off during stop. F [Room temperature] Display Displays the temperature of the air sucked in during operation. G [Fan speed] Display This displays indication High-speed or Low-speed. H [Key lock] Display This display indication during key lock function active. J [Timer Hold / Resume setting] Display - 101 - again * Once the buttons have been set, pressing of the [ON/OFF] button only can repeat the same operation thereafter. * During operation, the operation lamp above the [ON/OFF] button lights up. Caution: Warning: Check and confirm the power circuit before use. For the contents, refer to the previously described chapter [Crucial points to be observed for safety]. 1 Operation lamp goes off and operation stops. Even if the operation button is pressed immediately after the operation is once stopped, operation is not restarted for about 3 minutes. This function protects the machine. It automatically starts operation after the lapse of approximately 3 minutes. 2. Selecting operation 3. Room temperature adjustment B D F 2 B 3 Operation mode display D When selecting operation Press the [MODE] button Set temperature display and F room temperature display To change room temperature 2 Consecutive press of the [MODE] button switches the operation over to “FAN”, “COOL”, “HEAT” and “AUTO”. For the contents of operation, check the display. For fan Press the [MODE] button 2 and bring up the “FAN” display. * The fan operation functions to circulate the air in the room. * The temperature of the room cannot be set by fan operation. Press the [SET TEMP] button temperature of your choice. 3 and set the room Press or button once changes the setting by 1˚C. If the pressing is continued, the setting continues to change by 1˚C. * Indoor temperature can be set within the following range. Cooling 19 ~ 30 ˚C Heating 17 ~ 28 ˚C (PEH only) Caution: Never expose your body directly to cool air for a long time. Excessive exposure to cool air is bad for your health, and should therefore be avoided. For cooling Press the [MODE] button 2 and bring up the “COOL” display. 2 and bring up the “HEAT” display. For heating (PEH only) Press the [MODE] button Caution: * When the air conditioner is used together with burners, thoroughly ventilate the area. Insufficient ventilation can result in accidents due to oxygen deficiency. * Never place a burner at a place where it is exposed to the airflow from the air conditioner. Doing so can result in imperfect combustion of the burner. For Auto change over (PEH only) Press the [MODE] button 2 and bring up the “AUTO” display. This function is special order. Please consult your local Mitsubishi Electric Sales office for application advice on this function. Because this function need low ambient cooling parts as option. Indoor temperature can be set within the following range. Indoor temperature setting range : 17 ~ 30 ˚C - 102 - * It is impossible to set the room temperature by the air-blow operation. Press and button together, the unit of temperature change “˚C ” (degree-centigrade) and “˚F ”. (degree-Fahrenheit) 4. Time setting 5. Other function A H J 5 1 8 9 5 10 4 A J 7 7 6 Current time display Timer Hold/Resume display 11 Key lock Press the [MINUTE] button 7 three times consecutively, the word “KEY LOCK” will displayed H . At this time, only [ON-OFF] button 1 is valid. This function purpose is protect from mischief of child etc. Clock setting Press the [CLOCK] key 4 one time will activate set clock mode. Press the [CLOCK] key 4 again will disable set clock mode. Under set clock mode, the real time clock and present day setting can be changed by pressing [DAY] button 5 , [HOUR] button 6 or [MINUTE] button 7 . To cancel the key lock function, Please press [MINUTE] button 7 three times consecutively again. Caution: [CLOCK] key 4 is not allowed to be pushed with the thing of sharp tip. Test run 7-Days timer setting Press the [TEST] button 11 two times consecutively. The unit will run and finished automatically after two hours. There are two buttons for timer. One is [ON TIMER] 8 , another is [OFF TIMER] 9 . Press the button one time will activate set timer mode. Press the same button again will disable set timer mode. Under set timer mode, the 7-days timer setting can be changed by pressing [DAY] button 5 , [HOUR] button 6 or [MINUTE] button 7 . Day setting During set clock mode or set timer mode, press the [DAY] button will change the day setting. 5 Hour setting During set clock mode or set timer mode, press the [HOUR] button will change the hour setting. Minute setting During set clock mode or set timer mode, press the [MINUTE] button 7 will change the minute setting. Timer Hold / Resume setting If 7-days timer is set, then the word “Timer Active” is displayed J . To clear all the timers setting, press and hold the [HOLD] button 10 until the word “Timer Active” is not displayed. To resume the timer setting after timers have been held, press and hold the [HOLD] button 10 until the word “Timer Active” is displayed. - 103 - 6 LOW AMBIENT COOLING PARTS; OPTION PAC-205FC (Fan controller) 1. Outline This fan controller apply to following units. Model name Model name Q'TY PUH-5,8,10 (side blow) Q'TY PUH-15,20 PUH-7,8,10 (upper blow) 2 set 1 set PU-7,8,10 These units can be operated on cooling mode at the low ambient temperature with this optional FAN CONTROLLER. Please read carefully this manual and install following this. 2. Caution 1. Fan controller changes the outdoor fan speed. Strong wind is injurious to fan speed controller. Please install the windproof when unit is influenced by strong wind such as install it on the place there is no building in surrounding or the rooftop 2. As the case may be the operation with FAN CONTROLLER generate an electromagnetic sound from fan motor. Please consider the soundproofing wall equipment etc. when using the fan controller in the place where the noise becomes a problem. There is no worry which interferes to the unit though an electromagnetic sound might be generated from fan motor. 3. When shipping the fan controller, the dip switch on the control circuit board is set as follows. Do not change factory set of all dip switches. ON SW2 ON Only SW3 direction is different. SW3 ON ON SW1 SW2 SW1 SW0 SW0 SW3 1 2 3 4 1 (3,4 ON) 2 3 4 (All OFF) 1 2 3 4 (1,3 ON) 1 2 3 4 5 6 7 8 (1,3,4,5,6 ON) Control circuit board Fan controller inside 3. Parts There are the following parts in this box, and confirm whether there are all attached. There are two kinds of wiring sticker in this box. Accessory assy 1 Please select the pertinent one by model name. Accessory assy 2 Installation manual (This manual) Fan controller Accessory assy 1 Name Wiring sticker Screw Connector cap Spring Earth sticker Grommet 2 12 1 1 1 2 Pipe cover Band Connector assy 3 15 1 Shape Amount Accessory assy 2 Name Attachment Attachment Attachment Shape Amount 1 1 3 - 104 - 4. Installation 4-1. PU(H)-7,8,10 Please use the following parts during installation of fan controller. There are two kinds of wiring sticker, please use writing as "ONLY PU(H)-7,8,10". Accessory assy 1 Wiring sticker Use Accessory assy 2 Spring Connector cap Screw Earth sticker Attachment Grommet Band Pipe cover Connector assy ONLY PU(H)-7,8,10 9 1 Accessory assy 1 Wiring sticker Screw 1 1 Accessory assy 2 Attachment Attachment 1 2 3 3 15 1 Not use 3 1 1 1 4-1-1. Install 4-1-2. Wiring 1. The service panel and control box cover are removed. 1. The wiring from the printed circuit board CN04 is pulled out. (In case of PU-7,8,10 only) Control box cover Service panel Fan controller 2. Penetrate the knockout holes at Grommet the pillar L. The grommet (2 pieces) install to the hole for wiring in the pillar L. Wiring hole pull out CN04 Fan controller inside Pillar L Install to the top panel. (Screw 2 pieces) 3. The attachment (3 pieces) install to the unit with the screw (6 pieces). 2. Disconnect connector C11 - C11 and C21 - C21. The connector C11 and C21 remove to the motor side and the control box side. MF2 Control box C11 C21 C11 C21 F/C Install to the pillar L. (Screw 1 piece) Attachment 4. Wiring from the fan controller is passed through the hole of procedure 2. The thermistor and other wiring should use separate wiring hole. The fan controller install to the attachments with the screw (3 pieces). Thermistor wiring Other wiring only 3. Cover the connector C11 (control box side) is cap with the connector cap The connector assy connect as shown in the figure below. When it is connected, the connector is connected in the control box. The wiring from CN04 connect to the terminal block (F/C, N) in the control box. (In case of PUH-7,8,10 only) MF3 Connector assy Control box Fan controller C11 C21 C11 C21 Other wiring 5. Confirm the thermistor holder position. The spring insert in the thermistor holder. The thermistor (black wiring) which is connected to the fan controller is put in the holder. Thermistor Accumulator Thermistor holder position Compressor Thermistor position 6. Please use the pipe cover The thermistor wiring is bundled as follows before the pipe cover is installed. Fan controller Terminal block F/C N This wiring is PUH-7,8,10 only. CN04 U V W L1 L2 L3 Connector cap Please be careful, do not damage wires by the sheet metal edges or the fin, etc. 4. After connect wiring, to prevent wiring being damaged with the fin, the pipe cover (2 pieces) and band (4 pieces) are used. In that time, never bundle the thermistor wiring with other wiring. Thermistor holder Spring Insert the thermistor (1 piece) and fix with the band Pipe cover Thermistor wiring only (2 pieces). Band Other wiring Fan controller Band Pipe cover Thermistor wiring only Other wiring Pipe Comp cover 7. The earth sticker and wiring sticker are put on the following place. 1. The earth sticker is put on the top panel. 2. The wiring sticker is put on the control box cover (inside). Fan controller wiring sticker Earth sticker Control box Pillar L Control box cover Fan controller Put a earth sticker N Terminal block MF2 Thermistor wiring only MF3 Unit wiring sticker 5. After wiring ends, the wiring is bundled with a remaining band. Never bundle the thermistor and other wiring together. 6. Ensure there is not wiring mistake found, then only install the controller box cover and service panel. Put a wiring sticker - 105 - . 4-2. PUH-15,20 Please use the following parts during installation of fan controller. There are two kinds of wiring sticker, please use writing as "W881927". The fan controller is necessary for these models by two sets. (The following accessory parts show the fan controller one set.) Accessory assy 1 Wiring sticker Spring Screw Accessory assy 2 Earth sticker Grommet Attachment Pipe cover Band Use 1 Wiring sticker Not use 5 1 Accessory assy 1 Screw Connector 1 2 1 Accessory assy 2 Attachment Connector assy Attachment 3 15 ONLY PU(H)-7,8,10 1 7 1 1 3 4-2-1. Install 1 4-2-2. Wiring 1. The service panel and control box cover are removed. Control box cover 1. The wiring from the printed circuit board CN04 is pulled out. (In case of PR-15,20 only) Service panel 2. Penetrate the knockout holes at Grommet the top panel. The grommet (2x2 pieces) install to the hole for wiring in the top panel. Wiring hole 3. The attachment (2x1 pieces) install to the pillar 2 with the screw (2x2 pieces). pull out Fan controller CN04 Fan controller inside 2. Disconnect connector C11 - C11 and C21 - C21. The connector C11 and C21 remove to the motor side and the control box side. Install to the pillar 2. (Screw 2x2 pieces) MF2 MF3 Control box C11 C21 C11 C21 F/C N Attachment Terminal block 4. Wiring from the fan controller is passed through the hole of procedure 2. The thermistor and other wiring should use separate wiring hole. The fan controller install to the attachments with the screw (2x1 pieces) and install to the top panel with the screw (2x2 pieces). Install to the top panel. (Screw 2 pieces) Thermistor wiring only 3. When the fan controller is installed, the connector is connected in the control box. The wiring from CN04 connect to the terminal block (F/C, N) in the control box. (In case of PUH-15,20) Other wiring MF2 MF3 Terminal block Control box Fan controller C11 Thermistor wiring only Install to the top panel. (Screw 2 pieces) Other wiring C11 Fan controller Fan controller C21 C21 F/C N This wiring is PUH-15,20 only. CN04 U V W L1 L2 L3 CN04 U V W L1 L2 L3 Fan controller 5. Confirm the thermistor holder position. (2 places) The spring (2x1 pieces) insert in the thermistor holder. The thermistor (black wiring) which is connected to the fan controller is put in the holder. Please be careful, do not damage wires by the sheet metal edges or the fin, etc. Thermistor Thermistor holder 4. After connect wiring, to prevent wiring being damaged with the fin, the pipe cover (2x2 pieces) and band (2x4 pieces) are used. In that time, never bundle the thermistor wiring with other wiring. Thermistor holder position Compressor Spring Thermistor position 6. Please use the pipe cover (2x2 pieces). The thermistor wiring is bundled as follows before the pipe cover is installed. Top panel Control box Insert the thermistor (2x1 pieces) and fix with the band Pipe cover Thermistor wiring only Other wiring Thermistor wiring only Other wiring Band Band Pipe cover Fan controller Thermistor wiring only Pipe 7. The earth sticker and wiring sticker are put on an following place. 1. The earth sticker (2x1 pieces) is put on the top panel. 2. The wiring sticker (1 piece) is put on the control box cover (inside). Earth sticker 5. After wiring ends, the wiring is bundled with a remaining band. Never bundle the thermistor and other wiring together. 6. Ensure there is not wiring mistake found, then only install the controller box cover and service panel. Fan controller wiring sticker Unit wiring sticker Fan controller Put a earth sticker Put a wiring sticker Other wiring - 106 - 4-3. PUH-5,8,10 (Side blow type) Please use the following parts during installation of fan controller. There are two kinds of wiring sticker, please use writing as "W881927". Accessory assy 1 Wiring sticker Spring Screw Accessory assy 2 Earth sticker Grommet Pipe cover Band Use 1 Wiring sticker Not use 3 1 Accessory assy 1 Screw Connector 1 2 3 Accessory assy 2 Attachment Attachment Attachment 15 Connector assy ONLY PU(H)-7,8,10 1 9 1 1 4-3-1. Install 1 4-3-2. Wiring Control box cover 1. The service panel and control box cover are removed. 3 1 1. Disconnect connector C11- C11. The connector C11 removes to the motor side and the control box side. Service panel MF2 Control box C11 C11 51 Grommet 2. Penetrate the knockout holes at the pillar 3. The grommet (2 pieces) install to the hole for wiring in the pillar 3. Terminal block 2. When the fan controller is installed, the connector is connected in the control box. The wiring from CN04 connect to the terminal block (F/C, N) in the control box. Wiring hole Pillar 3 MF2 3. Wiring from the fan controller is passed through the hole of procedure 2. The thermistor and other wiring should use separate wiring hole. The fan controller install to the pillar 3 with the screw (1 piece) and install to the top panel with the screw (2 pieces). Control box Fan controller C11 Terminal block C11 Install to the top panel. (Screw 2 pieces) F/C CN04 N U V W L1 L2 L3 Thermistor wiring only Fan controller Please be careful, do not damage wires by the sheet metal edges or the fin, etc. Other wiring Install to the pillar 3. (Screw 1 piece) 3. After connect wiring, to prevent wiring being damaged with the pipe header, the pipe cover (2 pieces) and band (4 pieces) are used. In that time, never bundle the thermistor wiring with other wiring. 4. Confirm the thermistor holder position. The spring insert in the thermistor holder. The thermistor (black wiring) which is connected to the fan controller is put in the holder. Thermistor wiring only Other wiring Fan controller Thermistor holder position Thermistor Control box Thermistor holder Thermistor wiring only Compressor Accumulator 5. Please use the pipe cover Pipe cover (2 pieces). Band 5. Ensure there is not wiring mistake found, then only install the controller box cover and service panel. Pipe 6. The earth sticker and wiring sticker are put on an following place. 1. The earth sticker is put on the pillar 3. 2. The wiring sticker is put on the control box cover (inside). Unit wiring sticker Earth sticker Fan controller wiring sticker Fan controller Put a earth sticker Pillar 3 4. After wiring ends, the wiring is bundled with a remaining band. Never bundle the thermistor and other wiring together. Insert the thermistor (1 piece) and fix with the band Pipe cover Band Other wiring Spring Thermistor position The thermistor wiring is bundled as follows before the pipe cover is installed. N Put a wiring sticker - 107 - 5. Before starting the trial run. Please execute the following confirmations to prevent wrong connection. If there is wrong connection, it may damage fan controller, but also damage the unit. Confirmation Please intercept the power supply without fail, and secure safety when you execute detaching wiring, the connector, and the measurement machine to the following work. Step Step 1 Connected confirmation Confirmation matter Check Correspondence Step 1-1 Is fan controller's power supply input wiring position connected correctly as shown in installed manual? Step 1-2 Is the phase of the connection of fan controller power supply input (TB IN) accurate? Step 1-3 Is the phase of the connection of fan controller output (TB OUT) accurate? Step 1-4 Is the phase of connection of fan controller output wiring to fan motor accurate? Step 1-5 Is the thermistor for the condensing temperature detection of the attachment connected with CN01? Step 1-6 Is the thermistor for the condensing temperature detection accurately installed in the unit? Step 1-7 In case of the heat pump model, the wiring for full load input is connected with CN04? Step 1-8 In case of the heat pump model, the wiring for full load input is connected accurately in control box? Step 2-1 Does the fan rotate in a correct direction, when the unit is driven ? Step 2 Drive confirmation Step 2-2 The thermistor for the condensing temperature detection is removed to CN01. Drive to the cooling operation. (The unit stops abnormally when the cooling operation drive is continued for a long time occasionally. - High pressure switch off) Whether LED01 has blinked is confirmed. When the unit is in operation, the fan controller output voltage measured in TB OUT, and checked whether the output of about 200V. There is a problem when it is an output of about 300V. Troubleshooting 1,2 Troubleshooting 3 Step 2-3 The thermistor for the condensing temperature detection is surely connected with CN01 as before. Step 2-4 In case of the heat pump model and the heating drive is possible, the heating drive is executed and the voltage of CN04 is input AC198V - 264V. In that case, the fan must be full load drive. (The output of the power-supply voltage is confirmed in TB OUT. ) When heating cannot be driven, step 1-7, step 1-8 is executed again. Refer to Step 1-3 TB IN TB OUT Refer to Step 1-5 Step 2-2 Step 2-3 CN01 CN04 U Refer to Step 1-7 Step 2-4 V W L1 L2 L3 U : Red V : White W : Black L1 : Red L2 : White L3 : Black Fan controller layout - 108 - Refer to Step 1-2 Troubleshooting 4 Cause Check point - 109 - 6) The fan motor and unit side control box are defective. Fan power supply wiring is connected with fan controller power supply taking out part, and confirm operation. Whether the voltage is input to fan motor is confirmed. Whether the fan motor operation is confirmed. When the voltage impression and fan motor does not work, fan motor is defective. When the voltage is not impressed to the fan, the unit side control box is defective. When there is no wrong above-mentioned, it is assumed fan controller connection state, if abnormality relapses, the control printing board is defective and exchange. At the time of turning off light. The CN01 connector is removed, and measures resistance. When the resistance is 25 kilo-ohm or more, repair the control printing board due to the thermistor open breakdown. In case of thermistor is correct, the control printing board is defective and exchange. The content of P15 is judgment. (SCRM) The blinking of LED01 is confirmed. At the time of turning on light. (always) After checking item 1)-4), when the power supply is turned on, the blinking of LED01 is The CN01 connector is removed, and measures resistance. When the resistance is 1 kilo-ohm or confirmed. less, repair the control printing board due to the thermistor short-circuit breakdown. In case of thermistor is correct, the control printing board is defective and exchange. Replace SCRM when abnormality is found. Resistance between the lines of primary side Replace the transformer in case of abnormal resistance. (red and white) about 310 ohm. Resistance between the lines of secondary side (CN02 the connector is removed from the printing wiring board.) Between 1-3 pin about 0.9 ohm CN02- thermistor TB OUT - fan motor The wiring mistake is corrected. The power supply wiring is confirmed, and corrected. Troubleshooting 5) The control printing wiring board is defective. The resistance is confirmed. (Between the lines of primary side, and lines of secondary side.) The unit side connection is confirmed. The fan controller connection is confirmed. TB IN-NF wiring TB IN-T01-CN02. NF-SCRM-TB OUT CNU, CNV, CNW-SCRM (The connection is noted.) Is the power-supply voltage 342-457V? Content of confirmation 4) The thyristor module (SCRM) is defective. The content of P15 is checked. (SCRM) 3) The transformer (T01) is defective. 2) Connected mistake 1. The fun does not run. 1) The power-supply voltage is abnormal. The value of power-supply voltage is confirmed. (TB IN) State of Machine Please intercept the power supply without fail, and secure safety when you execute detaching wiring, the connector, and the measurement machine to the following work. 6. Troubleshooting - 110 - State of Machine Cause 3) Connected mistake 2) Output wiring supply reverse-phase. 1) Power supply reverse-phase. It becomes highpressure abnormal pressure. Something wrong occurs by step2-2 drive confirmation of installed confirmation matter. Check point The phase of U, V, W is corrected. Is the phase of U, V, W correct? Troubleshooting The phase of L1, L2,L3 is corrected. Content of confirmation Is the phase of L1, L2, L3 correct? The phase of U, V, W is corrected. Is the phase of U, V, W correct? The phase of fan motor output wiring is confirmed. (TB OUT) If the position where the thermistor is installed is wrong, the rotation speed control of the fan as condensing temperature is impossible. The connected phase is confirmed. The wiring mistake is corrected. When there is an input in CN04, the fan is full load.. TB OUT - fan motor (The phase (U, V, W) is noted.) Position of the wiring for full load input (In heating) Installation position of thermistor The content of P14 is judgment. (SCRM) SCRM exchange when abnormality is found. The set of dip switch is confirmed. (SW0-3) It is confirmed that the switch setting is The control substrate is matched to setting the (P2) corresponding to the electric wiring diagram. electric wiring diagram. The unit side connection is confirmed. When there is a connector connection in CNX, it is removed. There must not be connector connection in CNX. (CNX is compulsion full load input. Full load when short-circuited.) CNU, CNV, CNW-SCRM (The connection is noted.) CN02- thermistor CN04- the wiring for full load input in heating In cooling, when there is an input in CN04, wiring (CN04 input is AC198-264V in heating.) of CN04 is mistake connection. The wiring is corrected. NF-SCRM-TB OUT (The connection phase is noted.) TB IN-T01-CN02 (The connection phase is noted.) The connected phase is confirmed. The wiring mistake is corrected. The phase of L1, L2,L3 is corrected. Is the phase of L1, L2, L3 correct? The phase of input voltage is confirmed. (TB IN) The fan controller connection is confirmed. TB IN-NF wiring (The connection phase is noted.) During heating drive, there is an input in CN04 and the fan becomes full load drive. Normality Is not AC198-264V input in CN04? The input voltage is confirmed. (CN04) CNU, CNV, CNW-SCRM (The connection is noted.) The fan controller connection is confirmed. TB IN-NF wiring (The connection phase is noted.) The connected phase is confirmed. The wiring mistake is corrected. NF-SCRM-TB OUT (The connection phase is noted.) The phase of input voltage is confirmed. (TB IN) The phase of fan motor output wiring is confirmed. (TB OUT) 5) The thyristor module (SCRM) is defective. The content of P14 is checked. (SCRM) 4) The control printing wiring board setting is defective. 3) Connected mistake 2) Power supply reverse-phase. Output wiring reverse-phase. 3. The rotation speed 1) During heating drive of fans cannot control. 2. The fan rotates oppositely. - 111 - 4. The fan never becomes full load drive. (In heating) State of Machine Item 1) is checked, again. 3) The control printing wiring board is defective. After checking item 1), there is a possibility of a defective printed circuit board if a normal drive is not done. The content of P14 is judgment. (SCRM) 2) The thyristor module (SCRM) is defective. The content of P14 is checked. (SCRM) The unit side connection is confirmed. CNU, CNV, CNW-SCRM (The connection is noted.) CN04- the wiring for full load input (CN04 input is AC198-264V in heating.) Position of the wiring for full load input (In heating) NF-SCRM-TB OUT TB IN-T01-CN02 The fan controller connection is confirmed. TB IN-NF wiring 1) Connected mistake After checking item 1)-5), when the power supply is turned on, the blinking of LED01 is confirmed. Content of confirmation The blinking of LED01 is confirmed. Check point 6) The control printing wiring board is defective. Cause After checking item 1), if there is no problem, the control printing board is defective and exchange. Replace SCRM when abnormality is found. The wiring mistake is corrected. It is confirmed that wiring is correctly connected. The wiring mistake is corrected. At the time of blinking The item 2), 3) are confirmed again, and there is no connection mistake, the control printing board is defective and exchange. At the time of turning off light (There is a possibility of the thermistor open breakdown.) The CN01 connector is removed, and measures resistance. When the resistance is 25 kilo-ohm or more, repair the control printing board due to the thermistor open breakdown. In case of thermistor is correct, the control printing board is defective and exchange. At the time of turning on light (always) (There is a possibility of the thermistor short-circuit.) The CN01 connector is removed, and measures resistance. When the resistance is 1 kilo-ohm or less, repair the control printing board due to the thermistor short-circuit breakdown. In case of thermistor is correct, the control printing board is defective and exchange. Troubleshooting Thyristor module (SCRM) <Judgment Method> Measure the resistance between each of the SCRM pins and judge if there is a failure or not by the resulting values. <Judgment Values 1> Check between G and K. Use the smallest resistance range on the tester. Judgment Value: 1.5 ohm 80 ohm <Judgment Values 2> Check between AK1 and AK2. Use the greatest resistance range on the tester. Judgment Value: 60 kilo-ohm ohm <External View> AK1 AK1 AK1 K G K G K G G K G K G K AK2 AK2 AK2 <Internal Circuit Diagrams> AK1 AK1 AK1 K K K G G G G G K K AK2 G AK2 - 112 - K AK2 SPECIFICATION GUIDELINES Air to air reverse cycle split air conditioning system. The systems shall operate at out door ambient temperatures as high as __ ºC. The system shall have a total cooling capacity of __kW or greater with an indoor air quantity of __ L/s at __ ºC DB and __ ºC WB entering indoor coil temperature with a __ ºC temperature entering the outdoor coil. The system shall have a sensible heat capacity of kW or greater with a room DB temperature of __ ºC. The total heating capacity (without electric element heaters) shall be conditions, with __ ºC of indoor air entering indoor coil at __ ºC DB. kW or greater at __ ºC DB, __ ºC WB outdoor air The compressors shall be a welded high efficiency hermetic type with internal vibration isolation and be equipped with a crankcase heater. Coils shall be of non-ferrous construction with mechanically bonded aluminum plate fins Outdoor coils shall be made, of 9.52mm OD, 0.35mm thick formless copper tubes mechanically bonded to 0.12mm thick aluminum plate fins. Face area of the coil shall not be less than __ m 2 The coil shall be factory pressure and leak tested at 3.3 MPa pressure. The indoor coil face area shall be not less than __ m2. Multi-wing propeller type fans shall be fitted at the condenser and shall be dynamically balanced, to ensure smooth airflow and shall discharge vertically and be direct driven by a weatherproof three phase squirrel cage __kW induction motor. The system shall be factory wired and all electrical wiring must comply with the Local wiring code (Controls and control wiring shall be supplied by the contractor). Compressors and fan motors shall have both internal and current sensitive overload devices. An automatic defrost control shall be included to accomplish defrosting (only if required) every __minutes for a period of __minutes. High pressure switch (pre-set) shall be factory installed. The enclosure is weatherproof casing constructed of phosphatized, zinc coated steel with powder coating. (OUTDOOR UNIT) The unit shall be provided with hoisting plates for rigging and hoisting the unit. The hoisting plates shall be located in the pillars. (OUTDOOR UNIT) The unit shall have a drain connection provided (25mm BSP:male thread). The enclosure shall have openings provided for power connections. Access for both service and installation shall be provided to compressors, control wiring, and fans. Side panels and top panels shall be removable for easy service access. The unit maximum dimensions shall be : height: __mm, width: __mm and depth: __mm (INDOOR UNIT) : height: __mm, width: __mm and depth: __mm (OUTDOOR UNIT) Due to continuous product development, these guidelines are subject to change. - 113 - DATA BOOK Issuued in Nov. 2002 MEE01K074-A Printed in Japan. PE,PEH New publication effective Nov. 2002. Specifications subject to change without notice.