Download Datalogic DS6300 User`s guide
Transcript
DS6300 INSTALLATION QUICK REFERENCE CONTENTS DS6300-100-010 MASTER/SLAVES MODELS.......................................................................................................1 DS6300-100-012 ETHERNET MODELS..................................................................................................................5 DS6300-105-0XX OSCILLATING MIRROR MODELS ............................................................................................9 COMMON FEATURES ..........................................................................................................................................11 For further details on product installation, see the complete Reference Manual available on the configuration CD-ROM included with this product. NOTE DS6300-100-010 Master/Slave Models 1 Figure A 1 Laser Beam Output Window 1 5 1 3 4 3 2 2 Figure B Figure C 1 Programming Keypad 4 Power On LED (Red) 2 TX Data LED (Green) 5 LCD Display 1 Main/Aux. Interface 25-pin Connector 2 Lonworks 9-pin Male Connector 3 Lonworks 9-pin Female Connector 3 Phase On LED (Yellow) Available Models: DS6300 - 10X - 0YY Decoder Model Optical Model 10 = Master/Slave 11 = Profibus 12 = Ethernet 15 = Devicenet 0 = Standard 5 = Oscillating Mirror The following tables display each version’s reading performance. ELECTRICAL FEATURES Supply Voltage 12 - 30 Vdc Power 15 W typical Consumption 20 W Max. (including startup current) Communication Main (isolated) Aux Other Interfaces RS232 RS485 fullduplex RS232 Lonworks RS485 halfduplex Baud Rates Inputs Ext. Trigger 1, 3 aux. digital inputs Outputs 3 software programmable digital outputs 2400 to 115200 115200 (optocoupled NPN or PNP) (optocoupled) OPTICAL FEATURES Light Receiver Avalanche photodiode Wavelength 630 to 680 nm Safety Class Class 2-EN 60825-1; Class IICDRH Laser Control Security system to turn laser off in case of motor slow down READING FEATURES Scan Rate 600-1200 scans/s Max. Resolution 0.2 mm (8 mils) Max. Read. Distance Max. Read. Width (see reading diagram) Max. Depth of Field Aperture Angle USER INTERFACE LCD Display Keypad LED Indicators 2 lines by 16 characters LCD 3 keys Power ON (red color) Phase ON (yellow color) TX Data (green color) 1 DS6300 QUICK REFERENCE SOFTWARE FEATURES Readable Codes Interleaved 2/5 2/5 compressed Code 39 standard Codabar Code 128 EAN 128 Code 93 (standard & full ASCII) EAN/UPC Code Selection Up to 10 codes during one reading phase Headers and Up to 128-byte headers and Terminators 128-byte terminators Operating Modes On Line, Automatic, Test, Config. Mode Genius™ utility program Parameter Storage Non-volatile internal FLASH ENVIRONMENTAL FEATURES Operating 0° to +40 °C (+32 to +104 °F) Temperature Storage -20° to +70 °C (-4° to +158 °F) Temperature Humidity 90% non condensing Vibration IEC 68-2-6 test FC Resistance 1.5 mm; 10 to 55 Hz 2 hours on each axis Shock Resistance IEC 68-2-27 test EA 30 G; 11 ms 3 shocks on each axis Protection Class IP64 PHISYCAL FEATURES Std Models Dimensions (inch) Weight Oscill. Mirror mm 110x113x99 113x180x104.5 (4.33x4.45x3.9) (4.45x7.08x4.11) 1.5 kg (3.3 lb) 2.0 kg (4.4 lb) Accessories: Name GFC-60 GFC-600 CAB-6001 CAB-6002 CAB-6005 CAB-6101 CAB-6102 CAB-6105 CAB-6112 CAB-6115 CAB-6205 CAB-6210 INT-60 PWR-120 BTK-6000 PG6002 PG6001 PG6000 FBK-6000 USX-60 Description 90° mirror 90° mirror close distance Cable to C-BOX100 1 m Cable to C-BOX100 2 m Cable to C-BOX100 5 m Cable master/slave 1 m Cable master/slave 2 m Cable master/slave 5 m Cable master/slave no power 2 m Cable master/slave no power 5 m Cable to SC8000 5 m Cable to SC8000 10 m 20 mA C.L. interface board Power unit 110/230 V AC - 24 V DC Terminator kit (5 pcs) Single unit power supply – US Single unit power supply – UK Single unit power supply – EU Fast bracket kit (2 pcs) Adjustable bracket Part Number 93A201100 93A201102 93A051190 93A051200 93A051210 93A051220 93A051230 93A051240 93A051224 93A051225 93A051250 93A051260 93A151021 93ACC1530 93ACC1710 93ACC1718 93ACC1719 93ACC1720 93ACC1721 93ACC1729 Electrical Connections: The DS6300 reader provides a 25-pin male D-sub connector for connection to power supply, Host interface (Main and Aux), and input/output signals. Two 9-pin connectors provide access to the scanner’s local Lonworks network used for both input and output connections to build a multi-sided or omni-station system. 2 DS6300 QUICK REFERENCE The details of the connector pins are indicated in the following table: 25-pin D-Sub Male Connector Pinout Pin 1 20 21 8 22 11 12 16 17 18 19 6 10 14 15 24 9, 13 23, 25 Name Function Shield RXAUX TXAUX OUT 1+ OUT 1OUT 2+ OUT 2OUT 3A OUT 3B EXT_TRIG A EXT_TRIG B IN2A IN2B IN3A IN4A IN_REF VS GND Internally connected by capacitor to chassis Receive data of auxiliary RS232 (referred to GND) Transmit data of auxiliary RS232 (referred to GND) Configurable digital output 1 – positive pin Configurable digital output 1 – negative pin Configurable digital output 2 – positive pin Configurable digital output 2 – negative pin Configurable digital output 3 – polarity insensitive Configurable digital output 3 – polarity insensitive External trigger (polarity insensitive) External trigger (polarity insensitive) Input signal 2 (polarity insensitive) Input signal 2 (polarity insensitive) Input signal 3 (polarity insensitive) Input signal 4 (polarity insensitive) Common reference of IN3 and IN4 (polarity insensitive) Supply voltage – positive pin Supply voltage – negative pin 1 13 14 25 25-pin male D-sub Connector Pin RS232 RS485 Full-Duplex RS485 Half-Duplex 2 3 4 5 7 TX RX RTS CTS GND_ISO TX485+ RX485+ TX485RX485GND_ISO RTX485+ RTX485GND_ISO 9-pin Lonworks Connector Pinout Pin 1 9 2 6 3 4 5 7 8 Name Function Shield VS GND VS_I/O Ref_I/O SYS_ENC_I/O SYS_I/O LON A LON B Cable shield Supply voltage – positive pin Supply voltage – negative pin Supply voltage of I/O circuit Reference voltage of I/O circuit System signal System signal Lonworks line (polarity insensitive) Lonworks line (polarity insensitive) 1 5 9 6 Female 5 1 6 9 Male Local Lonworks Connectors Network Termination: When building a local Lonworks system the network must be properly terminated by positioning a BTK-6000 terminator on the DS6300 master reader (BTK-6000 female side) and on the last slave reader (BTK-6000 male side). 9-pin female 9-pin male BTK-6000 Network Terminator 3 DS6300 QUICK REFERENCE Connectivity: Point-to-point layout Local Lonworks Network (Single P.S.) Master DS6300 * C-BOX 100 CAB600X CAB610X * C-BOX 100 BTK6000 CAB600X Local Host Slave 1 Local Host P.S. BTK6000 CAB610X PG6000 PWR120 Slave 2 Single P.S. with 3 Readers Local Lonworks Network (Single P.S.) Master CAB600X * C-BOX 100 CAB611X Slave 1 CAB610X PWR120 Slave 2 Local Host CAB610X Slave 3 Single P.S. with more than 3 Readers Local Lonworks Network (Multi P.S.) CAB611X Slave 3 CAB610X CAB610X Slave 2 Slave 1 CAB600X Master * C-BOX 100 * C-BOX 100 PWR120 Local Host * 4 C-BOX 100 can support up to 2 DS6300 readers. Please contact Datalogic USS Technical Support, if your application requires a multi-slave network. DS6300-100-012 Ethernet Models 1 Figure A 1 Laser Beam Output Window 3 5 1 3 4 1 2 2 Figure B Figure C 1 Programming Keypad 4 Power On LED (Red) 2 TX Data LED (Green) 5 LCD Display 1 RJ45 Modular Connector for Ethernet Interface 2 Lonworks 9-pin Female Connector 3 Main/Aux. Interface 26 D-Sub Male Connector 3 Phase On LED (Yellow) Available Models: DS6300 - 10X - 0YY Decoder Model Optical Model 10 = Master/Slave 11 = Profibus 12 = Ethernet 15 = Devicenet 0 = Standard 5 = Oscillating Mirror The following tables display each version’s reading performance. ELECTRICAL FEATURES Supply Voltage 12 - 30 Vdc Power 15 W typical Consumption 20 W Max. (including startup current) Communication Main (isolated) Aux Other Interfaces RS232 Lonworks RS232 Ethernet RS485 fullduplex RS485 halfduplex Baud Rates Inputs Ext. Trigger 1, 3 aux. digital inputs Outputs 3 software programmable digital outputs 2400 to 115200 115200 (optocoupled NPN or PNP) (optocoupled) OPTICAL FEATURES Light Receiver Avalanche photodiode Wavelength 630 to 680 nm Safety Class Class 2-EN 60825-1; Class IICDRH Laser Control Security system to turn laser off in case of motor slow down READING FEATURES Scan Rate 600-1200 scans/s Max. Resolution 0.2 mm (8 mils) Max. Read. Distance Max. Read. Width (see reading diagram) Max. Depth of Field Aperture Angle USER INTERFACE LCD Display Keypad LED Indicators 2 lines by 16 characters LCD 3 keys Power ON (red color) Phase ON (yellow color) TX Data (green color) 5 DS6300 QUICK REFERENCE SOFTWARE FEATURES Readable Codes Interleaved 2/5 2/5 compressed Code 39 standard Codabar Code 128 EAN 128 Code 93 (standard & full ASCII) EAN/UPC Code Selection Up to 10 codes during one reading phase Headers and Up to 128-byte headers and Terminators 128-byte terminators Operating Modes Config. Mode On Line, Automatic, Test, Genius™ utility program Parameter Storage Non-volatile internal FLASH ENVIRONMENTAL FEATURES Operating 0° to +40 °C (+32 to +104 °F) Temperature Storage -20° to +70 °C (-4° to +158 °F) Temperature Humidity 90% non condensing Vibration IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz Resistance 2 hours on each axis Shock Resistance IEC 68-2-27 test EA 30 G; 11 ms 3 shocks on each axis PHISYCAL FEATURES Std Models Dimensions (inch) Weight Oscill. Mirror mm 110x113x99 113x180x104.5 (4.33x4.45x3.9) (4.45x7.08x4.11) 1.5 kg (3.3 lb) 2.0 kg (4.4 lb) Accessories: Name GFC-60 GFC-600 CAB-6011 CAB-6012 CAB-6015 CAB-6205 CAB-6210 INT-60 PWR-120 BTK-6000 PG6002 PG6001 PG6000 FBK-6000 USX-60 Description 90° mirror 90° mirror close distance Cable to C-BOX100 1 m Cable to C-BOX100 2 m Cable to C-BOX100 5 m Cable to SC8000 5 m Cable to SC8000 10 m 20 mA C.L. interface board Power unit 110/230 V AC - 24 V DC Terminator kit (5 pcs) Single unit power supply – US Single unit power supply – UK Single unit power supply – EU Fast bracket kit (2 pcs) Adjustable bracket Part Number 93A201100 93A201102 93A051221 93A051222 93A051223 93A051250 93A051260 93A151021 93ACC1530 93ACC1710 93ACC1718 93ACC1719 93ACC1720 93ACC1721 93ACC1729 Electrical Connections: The DS6300 Ethernet reader provides a 26-pin male D-sub connector for connection to power supply and input/output signals. An Ethernet connector is used for connection to the remote Host (for ex. Remote PC connected via Internet), while a local Lonworks 9-pin male connector connects the Ethernet master to the first slave reader of the system. The details of the connector pins are indicated in the following table: 6 DS6300 QUICK REFERENCE 26-pin D-Sub Male Connector Pinout Pin Name 1 20 21 8 22 11 12 16 17 18 19 6 10 14 15 24 9, 13 23, 25, 26 Shield RXAUX TXAUX OUT 1+ OUT 1OUT 2+ OUT 2OUT 3A OUT 3B EXT_TRIG A EXT_TRIG B IN2A IN2B IN3A IN4A IN_REF VS GND Function Internally connected by capacitor to chassis Receive data of auxiliary RS232 (referred to GND) Transmit data of auxiliary RS232 (referred to GND) Configurable digital output 1 – positive pin Configurable digital output 1 – negative pin Configurable digital output 2 – positive pin Configurable digital output 2 – negative pin Configurable digital output 3 – polarity insensitive Configurable digital output 3 – polarity insensitive External trigger (polarity insensitive) External trigger (polarity insensitive) Input signal 2 (polarity insensitive) Input signal 2 (polarity insensitive) Input signal 3 (polarity insensitive) Input signal 4 (polarity insensitive) Common reference of IN3 and IN4 (polarity insensitive) Supply voltage – positive pin Supply voltage – negative pin 9 1 10 19 18 26 26-pin male D-sub Connector Pin RS232 RS485 Full-Duplex RS485 Half-Duplex 2 3 4 5 7 TX RX RTS CTS GND_ISO TX485+ RX485+ TX485RX485GND_ISO RTX485+ RTX485GND_ISO 9-pin Lonworks Connector Pinout Pin 1 9 2 6 3 4 5 7 8 Name Shield VS GND VS_I/O Ref_I/O SYS_ENC_I/O SYS_I/O LON A LON B Function Cable shield Supply voltage – positive pin Supply voltage – negative pin Supply voltage of I/O circuit Reference voltage of I/O circuit System signal System signal Lonworks line (polarity insensitive) Lonworks line (polarity insensitive) 5 1 6 9 Male Local Lonworks Connectors RJ45 Female Modular Connector HUB / SWITCH DS6300 TX+ 1 1 TX- 2 2 RX+ 3 3 n. c. 4 4 n. c. 5 5 RX- 6 6 n. c. 7 7 n. c. 8 8 1 8 RJ45 Female Modular Connector n. c. = not connected 7 DS6300 QUICK REFERENCE Connectivity: Point-to-point layout Remote Host DS6300 * C-BOX 100 CAB601X PG6000 Ethernet Network Remote Host Ethernet Master CAB601X * C-BOX 100 Slave 1 PWR120 Slave 2 * 8 C-BOX 100 can support up to 2 DS6300 readers. Please contact Datalogic USS Technical Support, if your application requires a multi-slave network. DS6300-105-0XX Oscillating Mirror Models 1 Figure A 1 Laser Beam Output Window Oscillating mirror models are used when coverage of a large reading area is required, mainly in picket fence applications. The DS6300 scanner mounts a dedicated optic head with integrated oscillating mirror driven by a linear motor. The speed, precision, repeatability, and reliability of this driving technology assure high level performance. The new oscillating mirror is completely software controlled and software programmable. The Genius™ software tool allows adjusting the linear motor speed (oscillating frequency) and the upper and lower limits of the oscillation by defining the top and bottom line limit angles. When the oscillating mirror is programmed to read barcode labels at very small angles, position the reader to assure at least 10° for the Skew angle (see DS6300 Reference Manual). This angle refers to the most inclined or external laser line, so that all other laser lines assure more than 10° Skew. This avoids the direct reflection of the laser light emitted by the reader. 10° Oscillating Mirror Skew Angle Otherwise, the scanner can be mounted at an angle of inclination of 17.5° in order to attain symmetrical deflection ranges. 10 7. 5° 17.5° Oscillating Mirror Reading Position In the above case, the zone where the scan line is perpendicular to the reflecting surface corresponds to a neutral zone at the center of the reading field. 9 DS6300 QUICK REFERENCE The mirror can be deflected up to 40°. Oscillation with respect to the output window median axis is asymmetrical (see figure below). ° 3 7 .5 40° -2.5° 0° Oscillating Mirror Maximum Aperture and Asymmetry By configuring the oscillating speed up to the maximum value of 19 Hz, raster emulation can be performed for reading fast moving objects. Hz Max. Aperture 0-5 6-10 11-15 6-19 40° 30° 20° 10° By limiting the raster width to the minimum necessary, the number of scans on the reading surface is increased. NOTE Oscillating angles are selected in software where the minimum and maximum angles correspond to –2.5° and +37.5°. +37.5° +17.5° The scanner can be tilted in order for the 17.5° software setting to correspond with the 0° horizontal plane. -2.5° Oscillating Mirror Extreme Angle Positions These models provide higher scanning speed (1200 scans/sec) compared to standard models and the reading performance is not adversely effected by the oscillating mirror. The example represents the selection of an angle of +10° for the bottom line and an angle of +20° for the top line (see figure below). +37.5° +27.5° +17.5° Oscillating Mode 10 Common Features Mechanical Installation: TM The DS6300 reader can be positioned and installed in the best way possible as a result of the Step-A-Head feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading position. The reading head and the decoder base can be rotated independently from each other allowing the installation even in the most critical locations. Step-A-Head™ Feature The following diagrams give the overall dimensions of the reader standard model, oscillating mirror model and mounting bracket. They may be used for their installation: 16.5 0.65 85 3.34 42 1.65 22 0.86 4 0.15 30 1.18 76 2.99 50 1.96 35 1.37 5.11 130 30 1.18 82 3.22 50 1.96 20 0.78 60 2.36 25 0.98 18 0.71 10 0.4 Ø4.1 0.16 11 0.43 14 0.55 R5 11 0.43 14 0.55 R36 mm inch R22 75 2.95 113 4.45 50 1.96 72 2.83 100 3.93 36 1.41 74 2.85 99 3.90 R1 Ø8 110 4.33 .5 DS6300 Mounting Bracket Overall Dimensions 60 2.36 30 1.18 DS6300 Overall Dimensions mm inch 16.5 0.65 99 3.90 63.5 2.50 104.5 4.11 85 3.35 69 2.72 113 4.45 114 4.48 102 4.01 110.3 4.34 56 2.20 mm inch 180 7.08 DS6300 Oscillating Mirror Model Overall Dimensions 11 DS6300 QUICK REFERENCE Focus Adjustment: The DS6300 provides a manual adjustment of the optics to optimize the reading performance by choosing the best focus between two extreme positions. The focus adjustment is continuous and not by step; thus, allowing an optimum adjustment around the selected position. The relative focus positions range from 0 to 100. The adjustment can be simply made through an external screw placed on the back of the optic HEAD and protected by a cap. The screw may be rotated either clockwise or counterclockwise in order to move the scanner internal lenses. In particular, a clockwise rotation causes a farther focus from the scanner, while a counterclockwise rotation causes a nearer focus to the scanner. An internal sensor tracks the exact laser beam focusing position allowing it to be shown on the reader display or through the Genius™ software program. Do not stare at the laser beam output window during this operation to avoid hazardous visible laser light. WARNING Refer to the following instructions when adjusting the focus: 1) Remove the regulation screw protecting cap (see following Figure) positioned on the back of the optic Head; 2) Press and hold both the ▲ (up arrow) or ▼ (down arrow) key for about 2 seconds to enter the Main menu; 3) Use the ▲ (up arrow) or ▼ (down arrow) key to select “Test Mode” item, then press the ENT (enter) key to confirm. The reader enters Test Mode; 4) Press the ENT (enter) key to toggle between the graphical (default) and numerical visualization of the focus position; Display Visualization The first line of the display shows the read code and Good Read percentage. Possible suspending commas at the end of the code mean that the code is too long to be displayed. The second line of the display indicates the value of the focus position according to the table below. The indications “Too Near” or “Too Far” are represented for values outside the focus range. Graphical Visualization A |---^----------| Æ where . indicates the focus position B N-------------| Æ where N indicates that the focus position is “Too Near” C |--------------F Æ where F indicates that the focus position is “Too Far” CodeRead… 100% |------^------------------| Graphical Visualization Numerical Visualization Fxxx Æ where xxx ranges from 000 to 100 TooNear Fxxx* Æ where xxx is greater than 100 CodeRead… 094% F034 Normal Visualization 5) Rotate the focus adjustment screw to reach the desired focus position. The display is refreshed with the new values; 6) Press the ▲ (up arrow) key to exit the Test Mode; 12 DS6300 QUICK REFERENCE 7) Use the ▲ (up arrow) and ▼ (down arrow) key to select the “Exit” item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current operating mode. Focus Adjustment Screw The reader display shows the focus position only when the laser beam is activated. NOTE It is possible to visualize the focus position and the reading percentage on the terminal tool provided by the Genius™ configuration program (see Genius™ Help On-Line for details). Reading Diagrams: In the following reading diagrams (0,0) is the center of the laser beam output window. DS6300-100-0XX – Resolution: 0.20 mm/8 mils 0 0 10 6 8 10 12 14 250 8 200 6 150 4 100 2 50 0 0 -2 -50 -4 -100 -6 -150 -8 -200 16 18 20 22 24 (in) 150 200 250 300 350 400 450 500 550 600 Focus Position = 0 (mm) Focus Position = 40 -10 -250 (in) (mm) 13 DS6300 QUICK REFERENCE Reading Diagrams: DS6300-100-0XX – Resolution: 0.30 mm/12 mils 0 0 12 300 10 250 8 200 6 150 4 100 2 50 0 0 -2 -50 8 10 12 14 16 18 20 22 24 26 28 30 32 34 (in) 200 250 300 350 400 450 500 550 600 650 700 750 800 850 (mm) Focus Position = 0 Focus Position = 40 -4 -100 -6 -150 -8 -200 -10 -250 Focus Position = 60 -12 -300 (in) (mm) DS6300-100-0XX – Resolution: 0.50 mm/20 mils 0 0 24 600 20 500 16 400 12 300 8 200 4 100 0 0 8 12 16 20 24 Focus Position = 60 -8 -200 -12 -300 -20 -500 -24 -600 (in) (mm) 14 32 36 40 44 Focus Position = 100 -4 -100 -16 -400 28 48 52 54 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Focus Position = 0 (in) (mm) DS6300 QUICK REFERENCE Reading Diagrams: DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.20 mm/8 mils 0 0 10 250 8 200 6 150 4 100 2 50 0 0 -2 -50 -4 -100 -6 -150 -8 -200 6 8 10 12 14 16 18 20 22 24 (in) 150 200 250 300 350 400 450 500 550 600 Focus Position = 0 (mm) Focus Position = 40 -10 -250 (in) (mm) DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.30 mm/12 mils 0 0 12 300 10 250 8 200 6 150 4 100 2 50 0 0 -2 -50 8 10 12 14 16 18 20 22 24 26 28 30 32 34 (in) 200 250 300 350 400 450 500 550 600 650 700 750 800 850 (mm) Focus Position = 0 Focus Position = 40 -4 -100 -6 -150 -8 -200 -10 -250 -12 -300 (in) (mm) Focus Position = 60 15 DS6300 QUICK REFERENCE Reading Diagrams: DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.50 mm/20 mils 0 0 24 600 20 500 16 400 12 300 8 200 4 100 0 0 8 12 16 20 24 28 32 36 40 48 52 54 44 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 (in) (mm) Focus Position = 100 Focus Position = 60 -4 -100 -8 -200 -12 -300 -16 -400 Focus Position = 0 -20 -500 -24 -600 (in) (mm) Safety Precautions 1 1 2 Figure A Figure B 1 Warning and Device Class Label 1 Laser Safety Label 2 Identification Label 1 Figure C 1 Laser Safety Label 16 DS6300 QUICK REFERENCE The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed. The laser beam can be switched off through a software command (see also the Genius™ Help On-Line). AVOID EXPOSURE - LASER LIGHT IS EMITTED FROM THIS APERTURE Laser Safety Label for Oscillating Mirror and Standard Models CAUTION LASER LIGHT WHEN OPEN US AD DATALOGIC S.P.A. Via Candini, 2 40012 LIPPO DI CALDERARA (BO) ITALY Amp. MANUFACTURED VOLT 1.5-0.5 JANUARY 2002 10-30 DC MODEL No. J N2468 R R SERIAL No. EA FA LASER LIGHT - DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX. OUTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630~680 nm EN60825-1:1994 OC . F AVOID EXPOSURE TO BEAM N This product conforms to the applicable requirements of 21CFR 1040 at the date of manufacture. Warning and Device Class Label Device Identification Label The laser diode used in this device is classified as a Class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulations. As it is not possible to apply a classification label on the laser diode used in this device, the following label is reproduced below: LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT MAXIMUM OUTPUT RADIATION 35 mW EMITTED WAVE LENGTH 630~680 nm TO EN60825-1 (1994) Laser Diode Class Label Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (35 mW at 630 ~ 680 nm). Power Supply - This product is intended to be installed by Qualified Personnel only. All DS6300 Models: This device is intended to be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source which supplies power directly to the scanner via the 25/26-pin connector. 17 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DS6300-XXX-XXX, Laser Scanner and all its models e tutti i suoi modelli et tous ses modèles und seine modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: der nachstehend angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/336/EEC EMC Directive e 92/31/EEC, 93/68/EEC and et und y emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas 73/23/ECC Low Voltage Directive Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etates membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: EN 55022, August 1994: LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE) EN 61000-6-2, April 1999: ELECTROMAGNETIC COMPATIBILITY (EMC). PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS EN 60950, October 1996: SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT EN 60825, March 1993: RADIATION SAFETY OF LASER PRODUCTS, EQUIPMENT CLASSIFICATION, REQUIREMENTS AND USER’S GUIDE Lippo di Calderara, 16/04/2002 Ruggero Cacioppo Quality Assurance Supervisor 821000682 (Rev. B)