Download Rheem RMTG-64DV Specifications

Transcript
INTEGRATED HVAC
& WATER HEATING
HOME HEATING & WATER HEATING
POWERED BY TANKLESS TECHNOLOGY
RHEEM RESIDENTIAL TANKLESS
84
TANKLESS SERIES
Continuous hot water for 2-3 bathroom homes*
NEW
SPRING !
2010
Features of the Hydronic Air Handler
RTG-84DV indoor direct vent and RTG-84X outdoor
natural and LP models – 11,000 - 180,000 BTU max.
• Low profile 34-inch design is lighter, easier to handle and leaves
room for optional accessories
Limited Warranty:
• Left or right side electric connections
8.4 gal./min at 35° F rise max., 6.7 gal./min. at 45° F rise
12-Year on heat exchanger, 5-Year on parts, 1-Year on labor
See Residential Warranty Information Brochure for complete warranty information.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• Integrated control board features diagnostics, manages all operational functions and provides hookups for humidifier and electronic
air cleaner
New! 3"/5" Concentric Vent System with Integrated Condensate Collector
Connects to Metal Fab Inc., 3"/5" Concentric Venting without an adapter
New! Next Generation Burner Technology
Industry Best! .26 GPM Minimum Flow Rate, .40 GPM Minimum
Activation Flow Rate
UMC-117 remote control and 10 ft. of thermostat wire is included
EZ-Link™ cable available for high demand applications to connect two tankless
units to operate as one
New! Manifold up to 6 units with an optional MIC-6 manifold control board
Exclusive! All Rheem models can be linked in up to 20 unit manifold installations
by using the optional MIC-180 and MICS-180 manifold control assembly
High-altitude capability – up to 9,840 ft. elevation above sea level
(no chip required)
Exclusive! Guardian OFW™ overheat film wrap
All Rheem tankless models are third-party efficiency certified by GAMA
Continuous hot water, energy saving and compact, space saving design
Intelligent electronic controls designed to increase energy efficiency and safety
Self Diagnostic System
Digital display shows temperature setting and maintenance codes
Built-in electric blower
Supplied with a 120 volt power cord
Environmentally friendly Low NOx burner meets SCAQMD rule 1146
requirements
Freeze protection to -30° F
• An insulated blower compartment makes it one of the quietest
hydronic air handlers on the market today
180,000 BTU
INDOOR DIRECT VENT
• Pre-paint galvanized steel cabinet
• Molded permanent filter(s)
• Transformer and control fuse protection
• Solid bottom is standard
INSTALLATION INSTRUCTIONS
• A variety of cooling coils and plenums designed to use with the
180,000 BTU
HYDRONIC
AIR HANDLER
OUTDOOR
Product appearance may differ.
* Based on simultaneous showers using 2.5 gallons per minute. Flow rates vary depending
on temperature of cold water supply.
Hydronic Air Handler are available as optional accessories for air
conditioning models
RHWB-
The 84 Series Tankless models can be
converted for Commercial Installations
AIR HANDLER MODEL:
See Commercial Warranty Brochure for details.
RHWB- Series
Tankless water heaters
Features of the Tankless Water Heater
32,000 to AIR
90,000
BTUH [9.38 to 26.39 kW]
HYDRONIC
HANDLER
• Industry best! Minimum flow rate of .26 GPM, minimum activation flow rate of .40 GPM
• Nominal Heating Capacities
from
INSTALLATION
INSTRUCTIONS
Continuous hot water
RHWB-
• 3"/5" concentric vent system with integrated condensate collector
See reverse for specifications.
TANKLESS WATER HEATER MODELS:
RTG-64DV indoor direct vent and RTG-64X outdoor
• Natural and LP models – 11,000 - 150,000 BTU max.
• 6.4 gal./min at 35° F rise max., 5.6 gal./min. at 45° F rise
RTG-84DV indoor direct vent and RTG-84X outdoor
• Natural and LP models – 11,000 - 180,000 BTU max.
• 8.4 gal./min at 35° F rise max., 6.7 gal./min. at 45° F rise
RTG-95DV indoor direct vent and RTG-95X outdoor
• Natural and LP models – 11,000 - 199,900 BTU max.
• 9.5 gal./min at 35° F rise max., 7.4 gal./min. at 45° F rise
• Connects to Metal-Fab, Inc., 3"/5" concentric venting without an
adapter
• Next generation burner technology
• UMC-117 remote control and 10 ft. of thermostat wire is included
• EZ-Link™ cable available for high demand applications to connect
two tankless units to operate as one
• High-altitude capability – up to 9,840 ft. elevation above sea level (no chip required)
• Intelligent electronic controls designed to increase energy efficiency and safety
• Self Diagnostic System
ISO 9001:2008
DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP
IN A SAFE PLACE FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL.
92-24161-94-00
ISO 9001:2008
DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP
IN A SAFE PLACE FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL.
92-24161-94-00
HOME HEATING & WATER HEATING
POWERED BY TANKLESS TECHNOLOGY
1
3
2
HYDRONIC AIR HANDLER
HYDRONIC AIR HANDLER – INSIDE VIEW
SYSTEM COMPONENTS
1
2
3
2
HYDRONIC COIL
A
HYDRONIC AIR HANDLER
The hydronic air handler features a hydronic heating
coil in place of either electric heating elements or
gas-fired heat exchangers. When in heating mode,
the hydro pump circulates hot water between the
tankless water heater and the hydronic coil.
TANKLESS WATER HEATER
The Rheem tankless water heater serves two purposes in the hydronic system: it provides continuous
hot water for use throughout the home. When a call
for heat is made, the tankless water heater also acts
as the heat-source for air handler, providing both hot
water and heating for the home simultaneously.
COOLING COIL
In cooling mode, the cooling coil operates the same
as any other Rheem heating and cooling system.
INTEGRATED
CONTROL
B
STANDARD EQUIPMENT
assembled and wired; Hydronic coil; copper tubes with aluminum
Rheem Heating, Cooling and Water Heating Completely
fins; blower compartment door safety switch; solid state time on/off blower
control; cool fan off delay; field selectable heat fan “off” delay; power and selftest diagnostics; electronic air cleaner connections; humidifier connections;
humidifier on/off delay; single speed option for heating and cooling applications;
HYDRO PUMP
OPTIONAL EQUIPMENT
Side and bottom filter racks; return air cabinet for all sizes.
C
conditions:
requirements at design conditions:
06WMP48A unit will deliver 1560
CFM when configured for HIGH
Before using the Airflow Performance
The ACCA’s Manual J Residential Load
speed.
Table calculate the total static pressure
Calculation method is the established
required. From the given example, note
trade standard, approved by ANSI, for
the Wet Coil Pressure Drop (selected
the correct siziing and selection of
V. Select
heating
capacity of unit
IMPORTANT:
BEFORE
PURCHASING THIS
APPLIANCE,
READ
IMPORTANT ENERGY
COST
AND EFFICIENCY
from
the field supplied
Evaporative
Heating, Ventilation,
Air-Conditioning
to provide the requisite design
Coil Installation Instructions), and
and RefrigerationAVAILABLE
(HVACR) equipment
in Cased
INFORMATION
FROM YOUR
RETAILER.
condition:
the Filter Pressure Drop. Determine both
residential homes. The most recent
From the Hydronic Air Handler/
static pressures at 1600 CFM:
revision is the eight edition, an allTankless Water Heater, note that the
inclusive new approach to ensuring that
Wet Coil Pressure Drop. . . . .30 in. W.C.
unit RHWB-06WMP48A, (as selected
Indoor
Air Canadian
Quality (IAQ)Models
systems are as
(From Coil Manufacturer’s Installation Instructions)
U.S.
and
above) when matched with the RTGefficient, safe, and healthy as possible.
External
Static
Pressure
.
.
.
0.2
in.
W.C.
95 Tankless Water Heater, will
Refer
to theNUMBERS
Air Conditioning Contractors
MODEL
RHWB-10WRP60A
RHWB-06WMP48A
RHWB-08WRP60A
(Ductwork, etc.)
provide 59.2 MBH (59,200 BTU/HR)
of America
website
at:
NOMINAL HEATING CAPACITY RANGE (BTUH)
to 90,000
32,000 to 72,000
35,000 toat82,000
an input water35,000
temperature
(to Air
http://www.acca.org/tech/manualj/ or a
11
x 10
11
x
7
11
x
10
Handler)
of
150°F.
qualified
HVACR
contractor
for further
BLOWER
(D x W)
[mm]
[279 x 254]
[279 x 178]
[279 x 254]
assistance.
HYDRONIC AIR HANDLER PHYSICAL DATA AND SPECIFICATIONS
MOTOR HP [W] - SPEEDS - TYPE
MOTOR FULL LOAD AMPS
HEATING SPEED
3/4
[559] - 4 - PSC
9.5
Med Low
COOLING SPEED
Model
Number Nomenclature
HEAT EXT. STATIC PRESSURE (IN.W.C.) [kPa]
High
0.8 [.20]
RATED EXT. STATIC PRESSURE (IN.W.C.)RHWB
[kPa]
HEATING CFM @ .8" [.199 kPa] W.C. ESP [L/s]
Rheem
COOLING CFM @ .5" [.124 kPa] W.C. ESP [L/s]
1000 [471]
06W 0.5M[.12]
P 36
A
[559] - 4 - PSC
9.5
High
High
0.8 [.20]
High
0.8 [.20]
0.5 [.12]
1453 [685]
0.5 [.12]
1818 [858]
1973 [931]
35-65
[19.4-36.1]
60 = 1900-2100 CFM
C17B
(2) 12" x 16"
[305 x 406]
[mm]
Nominal
Heating
Capacity (BTU/HR)
STANDARD,
HIGH
VELOCITY
06W 60,000
PERMANENT
FILTER (IN.)
08W 80,000
APPROX. SHIPPING WEIGHT (LBS) [kg]
3/4
[559] - 4 - PSC
9.5
Med High
1871Revision
[883]
A = Rev 0
35-65
[19.4-36.1]
48 = 15-1700
CFM
1622 [765]
40-70
[22.2-38.9]
Air Handler
TEMPERATURE
Water RISE RANGE °F [°C]
Series
RETURN AIR Design
CABINETS
(OPT.)
Denotes a major design change in the
RXGRproduct
FILTER
SIZEline (i.e. capacity)
3/4
C24B
(2) 24" x 16"
C24B
(2) 24" x 16"
[609 x 406]
223/4 x 25 x 1
223/4 x 25 x 1
Variations [609 x 406]
P = PSC Motor
153/4 x 25 x 1
Blower Size
118 [53.5] M = 11x7
137 [62.1]
R = 11x10
10W 100,000
145 [65.7]
HYDRONIC AIR HANDLER MODEL IDENTIFICATION
R
H
W
B
Brand
Application
Type
Design
Series
W = Water
B = 2nd Series
R = Rheem H = Air handler
-06W
Heating Output Designation
Inlet Water
Temp = 150F
Output
BTU/HR
06W
08W
10W
60,000
80,000
90,000
M
P
Blower
Size
Variations
M = 11x7
R = 11x10
P = PSC
36
Heat/Cool
Designation
48 = 1500-1700 CFM
60 = 1900-2100 CFM
A
Revision
A = Rev 0
8
Rheem Heating, Cooling and Water Heating
3
UPFLOW MODELS
HYDRONIC AIR HANDLER DIMENSIONS AND SPECIFICATIONS
[
4
4
A
04WM
06WM
08WR
10WR
171/2 [445]
171/2 [445]
241/2 [622]
241/2 [622]
FIGURE 4
URN
IR
MODEL
RHWB-
CLEARANCE TO COMBUSTIBLES, UPFLOW, HORIZONTAL
NO DOWNFLOW
MINIMUM CLEARANCE (IN.)
MINIMUM
CLEARANCE (IN.) [mm]
SHIP
BACKLEFTTOP FRONT
WGTS
RIGHT
SIDE
BACK
TOP
FRONT
3⁄4 ID
06
171⁄2 1611⁄32 155⁄8
15
1325⁄32
0
0
0
1 SIDE
0*
118
7/8
1611/32 [415]
155/8 [397]
15 [422]
1325/32 [350]
0
0
0
1 [25]
2 [51]
3⁄4 ID
08
241⁄2 2311⁄32 225⁄8
22
2025⁄32
0
0
0
1
0*
137
7/8
15 [422]
1325/32 [350]
1611/32 [415]
155/8 [397]
0
0
0
1 [25]
2 [51]
3⁄4 ID
10 11 241⁄2 2311⁄325 225⁄8
22
2025⁄32
0 25 0
0
1
0*
145
7/8
23 /32 [593]
22 /8 [575]
22 [600]
20 /32 [528]
0
0
0
1 [25]
2 [51]
7/8 is recommended
*A service
clearance 22
of 5at
air handlers.
2311/32 [593]
/8 least
[575] 24 inches
22 [600] in front
2025of/32all
[528]
0
0
0
1 [25]
2 [51]
MODEL
B
A
B
C
C
D
] Designates Metric Conversions
Rheem Heating, Cooling and Water Heating
Rheem Heating, Cooling and Water Heating
D
E
E
F
LEFT
SIDE
RIGHT
SIDE
F
TABLE 4
HYDRONIC AIR HANDLER AIR FLOW PERFORMANCE - RHWB MODELS
HYDRONIC
AIR HANDLER AIR FLOW PERFORMANCE
- RHWB MODELS
CFM @ ESP
Model
RHWB-06WMP48A
RHWB-08WRP60A
RHWB-10WRP60A
Blower / Motor HP
11x7, 3/4
11x10, 3/4
11x10, 3/4
Speed
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Low
M-Lo
921
1189
915
1180
886
1179
876
1137
855
1131
841
1102
817
1072
780
1030
734
985
690
915
M-Hi
High
1335
1841
1315
1795
1306
1747
1307
1681
1277
1622
1246
1560
1210
1500
1161
1420
1090
1358
1019
1288
Low
1319
1307
1300
1240
1236
1210
1177
1149
1100
1032
M-Lo
M-Hi
1484
1687
1480
1676
1471
1671
1463
1611
1418
1586
1385
1553
1359
1513
1314
1453
1246
1389
1166
1284
High
1971
1974
1948
1929
1871
1806
1751
1699
1610
1511
Low
M-Lo
M-Hi
1299
1515
1684
1294
1519
1695
1308
1499
1693
1279
1487
1663
1257
1415
1620
1231
1418
1586
1205
1394
1569
1165
1348
1514
1122
1296
1451
1053
1221
1365
High
1954
1971
1974
1982
1973
1944
1917
1818
1775
1700
Note: Units tested without filters in place.
SETTING BLOWER
DIRECT DRIVE
TIMINGS
INSTRUCTIONS
FOR
HYDRONIC
AIR HANDLER
WITH
TANKLESS
WATER
HEATER
PERFORMANCE
TABLE
1
HYDRONIC
AIR HANDLER
TANKLESS
WATER
HEATER
PERFORMANCE
CHANGING BLOWER
The IAC (Integrated Air Handler
Entering Water Temperature (°F)
Controls) has four quick connect
SPEED
Heating Air Delivery
terminals
connecting
the
motor
Air Handlerfor
Model
Tankless
Model
Blower Speed ESP (in. w.c.)
120
(CFM)
speed leads. These are:
! WARNING
RTG-53
32600
1. FAN SPEED — motor runs on
RTG-64
DISCONNECT THE ELECTRICAL 40900
this speed when the thermostat
RTG-66
SUPPLY TO THE AIR HANDLER 40200
is in the “FAN ON” position.
RHWB-06WMP48A
High
0.5
1622
RTG-74
37800
BEFORE ATTEMPTING TO
2. COOL — connectRTG-84
desired
CHANGE THE BLOWER SPEED. 40000
cooling speed. RTG-95
FAILURE TO DO SO CAN CAUSE 37200
ELECTRICAL SHOCK RESULTING35000
RTG-53
3. HEAT — connect desired
IN PERSONAL INJURY OR DEATH.42000
heating speed. RTG-64
RTG-66
If RHWB-08WRP60A
cooling speed and fan
speed areMed-High
RTG-74
desired to be the same,
this may be
RTG-84
accomplished by not connecting
“Y”
RTG-95
to the IAC.
The blower motor must be wired for 40400
0.5
1586
blower speeds required for normal 40300
45800
operation.
45300
If additional blower speed taps are
available (leads connected to “M1” 35500
and “M2” on the electronic control), 40800
48300
speeds
0.5may be changed
1620if necessary49300
to fit requirements of the particular
installation. Reconnect the unused 43200
motor leads to “M1” or “M2.” Check 48300
“C.”
motor lead color for speed
Performance is based on the following assumptions:
designation.
Performance is based on the following assumptions:
1) an
an estimated
estimated100
100ft.ft.equivalent
equivalent
length
0.75-inch
piping
1)
length
of of
0.75-inch
piping.
Heating
speeds should not be
2) 0.80”
0.50”w.c.
w.c.ofofexternal
externalairairstatic.
static.
reduced where it could cause the air
handler air temperature rise to
exceed the maximum outlet air
temperature specified for the unit.
RTG-53
If desired for cool, fan and heat to all
RTG-64
be the same speed, then “piggyback”
RTG-66
jumper
“H/C” to “FAN” and do not Med-High
RHWB-10WRP60A
RTG-74
connect “Y” to the IAC. Do not
RTG-84
connect other motor leads to “H” or
RTG-95
130
140
150
160
39500
47100
46400
46200
47800
45200
47500
51000
54700
54000
52100
50900
N/A
N/A
63500
62700
60300
59200
N/A
N/A
71300
71300
68100
66400
41300
50900
50500
49700
53300
53100
50600
53400
56500
58800
56900
60000
N/A
N/A
65500
71600
66900
70500
N/A
N/A
73600
81600
76000
80700
44500
48000
57800
59600
51800
58200
53300
53200
62100
69500
56900
61000
N/A
N/A
71800
79100
65100
71000
N/A
N/A
83000
89700
75400
79800
IMPORTANT: Always check air
temperature rise after changing the
heating speed for any reason.
Rheem Heating, Cooling and Water Heating
5
RHEEM RESIDENTIAL TANKLESS
64
TANKLESS
SERIES
Continuous hot water for 1-2 bathroom homes*
NEW
SPRING !
2010
RTG-64DV indoor direct vent and RTG-64X outdoor
natural and LP models – 11,000 - 150,000 BTU max.
6.4 gal./min at 35° F rise max., 5.6 gal./min. at 45° F rise
Limited Warranty:
12-Year on heat exchanger, 5-Year on parts, 1-Year on labor
See Residential Warranty Information Brochure for complete warranty information.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
New! 3"/5" Concentric Vent System with Integrated Condensate Collector
Connects to Metal Fab Inc., 3"/5" Concentric Venting without an adapter
New! Next Generation Burner Technology
Industry Best! .26 GPM Minimum Flow Rate, .40 GPM Minimum
Activation Flow Rate
UMC-117 remote control and 10 ft. of thermostat wire is included
EZ-Link™ cable available for high demand applications to connect two tankless
units to operate as one
New! Manifold up to 6 units with an optional MIC-6 manifold control board
Exclusive! All Rheem models can be linked in up to 20 unit manifold installations
by using the optional MIC-180 and MICS-180 manifold control assembly
High-altitude capability – up to 9,840 ft. elevation above sea level
(no chip required)
Exclusive! Guardian OFW™ overheat film wrap
All Rheem tankless models are third-party efficiency certified by GAMA
Continuous hot water, energy saving and compact, space saving design
Intelligent electronic controls designed to increase energy efficiency and safety
Self Diagnostic System
Digital display shows temperature setting and maintenance codes
Built-in electric blower
Supplied with a 120 volt power cord
Environmentally friendly Low NOx burner meets SCAQMD rule 1146
requirements
Freeze protection to -30° F
150,000 BTU
INDOOR DIRECT VENT
150,000 BTU
OUTDOOR
Product appearance may differ.
* Based on simultaneous showers using 2.5 gallons per minute. Flow rates vary depending
on temperature of cold water supply.
SPECIFICATIONS
DESCRIPTION
MODEL
NUMBER
GAS
INPUT
BTU/HR.
FEATURES
TYPE
TEMP.
RANGE
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
WATER FLOW RATE
GPM @ 77° GPM @ 45° GPM @ 35° CONNECTION
RISE MAX. RISE MAX. RISE MAX. WATER GAS
ENERGY INFO.
VENT
DIAMETER
(INCHES)
SHIP.
WEIGHT
(LBS.)
ENERGY
FACTOR
D.O.E. ANN.
OP. COST
NAT/LP
ȐȧߓࠜȧȒ
Ȓȑ
ȵȕȹ
ȫȹȹȐȶȫȐȔȑ
߷ȶߪ
Ȓȑ
ȵȕȹ
ȫȹȹȐȶȫȐȔȑ
Tankless water
heaters
HEIGHT WIDTH
DEPTH
Continuous hot water
RHEEM TANKLESS WATER HEATERS FOR 3 BATHROOM HOMES
߻߽߰ȴȓȑ߭߿߷
ȸȸȳȷȷȷȧȴ
ȸȒȷȳȷȷȷ
߻߽߰ȴȓȑࠁ߷
ȸȸȳȷȷȷȧȴ
ȸȒȷȳȷȷȷ
߲ߟߕߠߠߣ
ȸȷȷɔȧߥߠ
ȸȑȷɔȧ߯
ȐȵȐ
Ȓȵȓ
ȓȵȑ
Ȑȶȑ
Ȑȶȑ
ȹȒȴȒȶȕ
ȸȐȴȔȶȕ
ȖȴȔȶȕ
߸ߦߥߕߠߠߣ
ȸȷȷɔȧߥߠ
ȸȑȷɔȧ߯
ȐȵȐ
Ȓȵȓ
ȓȵȑ
Ȑȶȑ
Ȑȶȑ
ȹȐȴȒȶȕ
ȸȐȴȔȶȕ
ȕȴȔȶȕ
߭ߚߣߖߔߥȧ߿ߖߟߥ
See reverse for specifications.
6
Rheem Heating, Cooling and Water Heating
߬߸߷߬߮߷߽߻߲߬
RHEEM RESIDENTIAL TANKLESS
84
TANKLESS
SERIES
Continuous hot water for 2-3 bathroom homes*
NEW
SPRING !
2010
RTG-84DV indoor direct vent and RTG-84X outdoor
natural and LP models – 11,000 - 180,000 BTU max.
8.4 gal./min at 35° F rise max., 6.7 gal./min. at 45° F rise
Limited Warranty:
12-Year on heat exchanger, 5-Year on parts, 1-Year on labor
See Residential Warranty Information Brochure for complete warranty information.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
New! 3"/5" Concentric Vent System with Integrated Condensate Collector
Connects to Metal Fab Inc., 3"/5" Concentric Venting without an adapter
New! Next Generation Burner Technology
Industry Best! .26 GPM Minimum Flow Rate, .40 GPM Minimum
Activation Flow Rate
UMC-117 remote control and 10 ft. of thermostat wire is included
EZ-Link™ cable available for high demand applications to connect two tankless
units to operate as one
New! Manifold up to 6 units with an optional MIC-6 manifold control board
Exclusive! All Rheem models can be linked in up to 20 unit manifold installations
by using the optional MIC-180 and MICS-180 manifold control assembly
High-altitude capability – up to 9,840 ft. elevation above sea level
(no chip required)
Exclusive! Guardian OFW™ overheat film wrap
All Rheem tankless models are third-party efficiency certified by GAMA
Continuous hot water, energy saving and compact, space saving design
Intelligent electronic controls designed to increase energy efficiency and safety
Self Diagnostic System
Digital display shows temperature setting and maintenance codes
Built-in electric blower
Supplied with a 120 volt power cord
Environmentally friendly Low NOx burner meets SCAQMD rule 1146
requirements
Freeze protection to -30° F
180,000 BTU
INDOOR DIRECT VENT
180,000 BTU
OUTDOOR
Product
appearance may differ. SERIES
84
TANKLESS
* Based on simultaneous showers using 2.5 gallons per minute. Flow rates vary depending
on temperature of cold water supply.
The 84 Series Tankless models can be
Specifications
SPECIFICATIONS
converted for Commercial Installations
DESCRIPTION
FEATURES
See Commercial
Warranty Brochure for details.
MODEL
NUMBER
GAS
INPUT
BTU/HR.
TYPE
TEMP.
RANGE
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
WATER FLOW RATE
GPM @ 77° GPM @ 45° GPM @ 35° CONNECTION
RISE MAX. RISE MAX. RISE MAX. WATER GAS
11,000180,000
RTG-84XN
11,000180,000
HEIGHT
WIDTH
DEPTH
ENERGY
FACTOR
D.O.E. ANN.
OP. COST
NAT/LP
3 by 5
54
.82
$223/$374
N/A
54
.82
$223/$374
Continuous hot water
Indoor
85° to
140° F
3.9
6.7
8.4
3/4
3/4
25-5/8
13-7/8
9-7/8
Outdoor
85° to
140° F
3.9
6.7
8.4
3/4
3/4
23-5/8
13-7/8
8-7/8
Direct Vent
ENERGY INFO.
SHIP.
WEIGHT
(LBS.)
Tankless water heaters
RHEEM TANKLESS WATER HEATERS FOR 3 BATHROOM HOMES
RTG-84DVN
VENT
DIAMETER
(INCHES)
CONCENTRIC
See reverse for specifications.
All models are available in Natural Gas and Propane (LP).
For Propane replace the N with P when ordering.
• Factory set maximum temperature is 120° F. See Use and Care Manual for setting.
• Consult factory for information on sizing the application.
Vent Termination Kits are required for Direct Vent models. Contact your distributor for details.
*COMMERCIAL OPERATION AVAILABLE WITH CONVERSION KITS:
RTG20216A FOR RTG-84DVN
Rheem Heating,
Cooling
and Water Heating
RTG20216B
FOR RTG-84DVP
RTG20216C FOR RTG-84XN
7
RHEEM RESIDENTIAL TANKLESS
95Continuous
TANKLESS
SERIES
hot water for 3 bathroom homes*
RTG-95DV indoor direct vent and RTG-95X outdoor
natural and LP models – 11,000 - 199,900 BTU max.
9.5 gal./min at 35° F rise max., 7.4 gal./min. at 45° F rise
Limited Warranty:
12-Year on heat exchanger, 5-Year on parts, 1-Year on labor
See Residential Warranty Information Brochure for complete warranty information.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
New! 3"/5" Concentric Vent System with Integrated Condensate Collector
Connects to Metal Fab Inc., 3"/5" Concentric Venting without an adapter
New! Next Generation Burner Technology
Industry Best! .26 GPM Minimum Flow Rate, .40 GPM Minimum
Activation Flow Rate
UMC-117 remote control and 10 ft. of thermostat wire is included
EZ-Link™ cable available for high demand applications to connect two tankless
units to operate as one
New! Manifold up to 6 units with an optional MIC-6 manifold control board
Exclusive! All Rheem models can be linked in up to 20 unit manifold installations
by using the optional MIC-180 and MICS-180 manifold control assembly
High-altitude capability – up to 9,840 ft. elevation above sea level
(no chip required)
Exclusive! Guardian OFW™ overheat film wrap
All Rheem tankless models are third-party efficiency certified by GAMA
Continuous hot water, energy saving and compact, space saving design
Intelligent electronic controls designed to increase energy efficiency and safety
Self Diagnostic System
Digital display shows temperature setting and maintenance codes
Built-in electric blower
Supplied with a 120 volt power cord
Environmentally friendly Low NOx burner meets SCAQMD rule 1146
requirements
Freeze protection to -30° F
199,900 BTU
INDOOR DIRECT VENT
199,900 BTU
OUTDOOR
Product
appearance may differ. SERIES
95
TANKLESS
* Based on simultaneous showers using 2.5 gallons per minute. Flow rates vary depending
on temperature of cold water supply.
The 95 Series Tankless models can be
Specifications
SPECIFICATIONS
converted for Commercial Installations
DESCRIPTION
FEATURES
See Commercial
Warranty Brochure for details.
MODEL
NUMBER
GAS
INPUT
BTU/HR.
TYPE
TEMP.
RANGE
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
WATER FLOW RATE
GPM @ 77° GPM @ 45° GPM @ 35° CONNECTION
RISE MAX. RISE MAX. RISE MAX. WATER GAS
11,000199,900
RTG-95XN*
11,000199,900
HEIGHT
WIDTH
DEPTH
ENERGY
FACTOR
D.O.E. ANN.
OP. COST
NAT/LP
3 by 5
54
.82
$223/$374
N/A
54
.82
$223/$374
Continuous hot water
Indoor
85° to
140° F*
4.3
7.4
9.5
3/4
3/4
25-5/8
13-7/8
9-7/8
Outdoor
85° to
140° F*
4.3
7.4
9.5
3/4
3/4
23-5/8
13-7/8
8-7/8
Direct Vent
ENERGY INFO.
SHIP.
WEIGHT
(LBS.)
Tankless water heaters
RHEEM TANKLESS WATER HEATERS FOR 3 BATHROOM HOMES
RTG-95DVN*
VENT
DIAMETER
(INCHES)
CONCENTRIC
See reverse for specifications.
All models are available in Natural Gas and Propane (LP).
For Propane replace the N with P when ordering.
8
• Factory set maximum temperature is 120° F. See Use and Care Manual for setting.
• Consult factory for information on sizing the application.
Vent Termination Kits are required for Direct Vent models. Contact your distributor for details.
Rheem Heating, Cooling and Water Heating
*COMMERCIAL OPERATION AVAILABLE WITH CONVERSION KITS:
RTG20214A FOR RTG-95DVN
RTG20214B FOR RTG-95DVP
RTG20214C FOR RTG-95XN
ACCESSORIES
ACCESSORIES
ACCESSORIES
RETURN AIR PLENUM: RXGR-C17B
RXGR-C24B
RETURN AIR PLENUM: RXGR-C17B
EXTERNAL BOTTOM FILTER
RACK: RXGF-CB
RXGR-C24B
EXTERNAL
FILTER
RACK:
RXGF-CA
EXTERNAL SIDE
BOTTOM
FILTER
RACK:
RXGF-CB
EXTERNAL SIDE FILTER RACK: RXGF-CA
FILTER RACK FILTER SIZES* INCHES [mm]
RXGF-CA
RXGF-CB
MODELFILTER RACK FILTER SIZES* INCHES [mm]
(SIDE)
(BOTTOM)
3/4 x 25
3/4 x 25
RXGF-CB
RXGF-CA
15
15
MODEL
RHWB-04WMAES
(BOTTOM)
(SIDE)
[400
x 635]
[400
x 635]
3/4 x 25
3/4 x 25
15
15
RHWB-04WMAES
RHWB-06WGAES
[400 x 635]
[400 x 635]
3
15
/
4
x
25
153/4 x 25
22
RHWB-06WGAES
RHWB-08WRAJS
[400 x 635]
[578
[400 x 635]
223/4 x 25
153/4 x 25
[578 x 635]
[400 x 635]
153/4 x 25
*Filter racks
are shipped without filters.223/4 x 25
RHWB-10WRAJS
[578may
x 635]
[400 1"
x 635]
Filters shipped with hydronic air handler
be used or a suitable
[25.4 mm]
filter. racks are shipped without filters.
*Filter
Filters shipped with hydronic air handler may be used or a suitable 1" [25.4 mm]
filter.
RHWB-08WRAJS
RHWB-10WRAJS
PLENUM DATA FOR “INDOOR COOLING” COILS
Plenum adapters are required in some instances for use on appliPLENUM
“INDOOR
COOLING”
COILS
cations
whenDATA
plenumFOR
and hydronic
air handler
size do not
match.
Plenum
adapters
are requiredSheet
in some
See
Indoor
Coil Specification
for instances
Details. for use on applications
when
plenum
and
hydronic
air
handler
size do not match.
AIR HANDLER
PLENUM
COIL
See Indoor
Coil
Specification
Sheet
for
Details.
WIDTH
WIDTH
PLENUM ADAPTER
[mm]
AIRIN.
HANDLER
1/2 [445]
17WIDTH
IN.
1/2[mm]
17
[445]
1
17
171//22 [445]
[445]
1711//22 [445]
17
[445]
1711//22 [445]
24
[622]
1711//22 [445]
24
[622]
IN.
[mm]
PLENUM
1/4 [413]
16WIDTH
IN.
1/4[mm]
20
[514]
1
16
215//48 [413]
[549]
1
20
251//44 [514]
[641]
5
21
251//84 [549]
[641]
PLENUM
ADAPTER
RXAA-C185
RXAA-C173
RXAA-C185
RXAA-C187
RXAA-C173
RXAA-C174
RXAA-C187
RXAA-C177
[
1
25
RXAA-C174
215//48 [641]
[549]
RXAA-C187
241/2 [622]
251/4 [641]
RXAA-C177
215/8 [549]
RXAA-C187
241/2 [622]
] Designates Metric Conversions
[
] Designates Metric Conversions
PLENUM
COIL
RXAL-B16BU
PLENUM
RXAL-B20BU
RXAL-B16BU
RXAL-B21BU
RXAL-B20BU
RXAL-B25BU
RXAL-B21BU
RXAL-B25BU
RXAL-B25BU
RXAL-B21BU
RXAL-B25BU
RXAL-B21BU
TANKLESS WATER HEATER ACCESSORIES
Visit RheemTankless.com for a current listing of Rheem
Tankless accessories.
Rheem
Heating,
Cooling
Water
Heating
Rheem
Heating,
Cooling
andand
Water
Heating
97
Rheem Heating, Cooling and Water Heating
7
TYPICAL PIPING ARRANGEMENT FOR DIRECT SPACE HEATING AND
DOMESTIC WATER SUPPLY WITH TANKLESS
(BV)
(DV)
All piping to be 3/4 inch.
Evaporator Coil
Air Separator
Flow Switch
10
Rheem Heating, Cooling and Water Heating
Rheem Heating, Cooling and Water Heating
11
[
] Designates Metric Conversions
GENERAL
WARRANTY
GENERALTERMS
TERMSOFOFLIMITED
LIMITED
WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
Hydronic
AirParts*
Handler
WarrantyRequired).......Ten
Terms
Conditional
(Registration
(10) Years
*For Complete Details of the Limited Warranty, Including Applicable
Terms and Conditions, See Your Local Installer or Contact the
Manufacturer for a Copy.
Any Other Part* . . . . . . . . . . . . . . . . . . . . . . Five (5) Years
Labor* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . One (1) Year
Air Handler Heat Exchanger/Coil* . . . . . . . . . Five (5) Years
Rheem Heating, Cooling and Water Heating
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
Rheem Heating,
Cooling and
Water Heating
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without no tice.”
PRINTED IN U.S.A.
12
04-10 DC
Rheem Heating, Cooling and Water Heating
FORM NO. H11-534
Supersedes Form No. G11-450 Rev. 16
5