Download Crestron DM-TX-300N-F Specifications
Transcript
DM-TX Series quickstart guide DigitalMedia™ Transmitters 1 Before Starting ! DM-TX-100/100-F CAUTION: Do not connect power cords until instructed to do so. HDMI IN USB HID LAN DM-TX-200 S G IR PWR NOTE: Before beginning any of these QuickStart procedures, make certain that all DigitalMedia™ cables are installed throughout the home. Mounting Brackets (2) DM LINK Use appropriate hardware (not supplied) to mount unit. HDMI IN SETUP RESET 2 Mounting The DM-TX-100/100-F has attached mounting brackets and is designed to be mounted on a flat surface or attached to a rack rail in the back of an equipment cabinet. It may also be used portably for connection to a wall plate input, and is compact enough to fit discreetly inside a presentation lectern or beneath a table. The DM-TX-200, supplied with a mounting bracket and attaching screws, is designed to be mounted on a flat surface and can even be concealed inside a raceway. DM-TX-100 Optional rack rail mounting. DM OUT D The DM-TX-300N/300N-F is designed to be mounted in an equipment rack using supplied “ears.” These ears must be installed prior to mounting the unit. The only tool required is a #2 Phillips screwdriver. ! M G G B A 24 DM-TX-300N/300N-F Mounting Ears (2) Remove and use the three screws on each side to attach the “ears” to the unit for rack mounting. Do not attach if unit is to be placed on a shelf or stacked. (Refer to NOTE at left.) NOTE: If rack mounting is not required, rubber feet are provided for tabletop mounting or stacking. Apply the feet near the corner edges on the underside of the unit. NOTE: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips). 1 For details, refer to the latest revision of the DM-TX-100, DM-TX-200, and/or DM-TX-300N series DigitalMedia™ Transmitter Guides, Doc. 6810, 6741, or 6907, respectively. QUICKSTART DOC. 6804C (2024043) 01.10 www.crestron.com ©2010 Specifications subject to change without notice. 888.273.7876 201.767.3400 All brand names, product names, and trademarks are the property of their respective owners. Mounting Bracket Use two screws (supplied) to attach to unit for flush mounting. Do not attach if unit is to be placed in a raceway. DM-TX Series WARNING: To prevent bodily injury when mounting or servicing this unit in a rack, take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: • When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. • If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. DM-TX-Series Connection to Room Controller (DM CAT) Connecting to DigitalMedia Room Controller or DigitalMedia Switcher Using a DigitalMedia™ cable (DM-CBL-P or DM-CBL-NP), connect the transmitter(s) directly to a DigitalMedia Room Controller (if required, first connect to a DigitalMedia Repeater and then connect the output of the repeater to a room controller), or connect the transmitter(s) to a DigitalMedia Switcher (via a DMC-CAT/DMC-F interface card). Power Supply PW-2407RU (Not Supplied) LA N IR 2 1 GSG S M Y LA 1 H U B S D N G X T X R TS R TS C D M ID T SE RE CO H D M I P TU SE C D R M K D IN I L DM H IN IN B G R P U T E S R W P IO D U A B G DM INK L EO L VID TR CN R D E M R S -R O T O M R M O C -1 N C O 0 0 N T R O L L E R 4 2 A B G T U O M M D T E S E D T igi ra ta n lM sm e it di te a r IN R M 24 A B G IN 2 B MI HD NS SE Red Orange C -RM Black Gnd Gray Connect the cable from the PW-2407 power supply to either end of the DigitalMedia From “DMNet” Cable, as shown in PW-2407RU the diagram to the right. 0 -10 SG Dig i SwtalM itc edi he a r DM “DMNet” Control & Power For details, refer to the latest revision of the DM-TX-100, DM-TX-200, and/or DM-TX-300N series DigitalMedia™ Transmitter Guides, Doc. 6810, 6741, or 6907, respectively. QUICKSTART DOC. 6804C (2024043) 01.10 UE OT S (SL UT TP DM 7 ICS , NJ 0764 CHO C ELE CTR Fiber OR DigitalMedia Cable IGH LE CK , RO EL 2) DE : RISQ INC ON TR EC ON TR OU AVIS A US ES CR P TU SE IR M D N G X T X R TS R TS C CO D M 4 G2 R PW DM INK L EO L VID TR CN Y LA RE 1 5 IR G B HID US S T 24 A B G I-I DV MI HD Power supply (supplied) required for fiber configurations. P OM IN C/C EO Pr/ VID /Y Pb 0-F I-I DV 0 C-1 MI HD R A IN 47 T OU INC , NJ IGH LE CK ., RO EC EL ICS ON TR TRON CRES 076 US Fiber configurations require local power supplies (supplied). Setting Up Ethernet Setup of the IP address for the DigitalMedia transmitters depends on the way the transmitters are configured within the DigitalMedia system. 1. Transmitters connected to a room controller use their own configuration settings. The units ship in DHCP mode, but the following static addresses can be set on the units by holding the SETUP button depressed while the unit boots up: • The DM-TX-100, 200, and 300 series units default to 192.168.1.231/232/233. • The DM-RMC-100/100-F defaults to 192.168.1.241/242. NOTE: This process overwrites any current settings. Also, for the DM-TX-100/100-F, the USB console is enabled and HID functionality is blocked until reboot. www.crestron.com ©2010 Specifications subject to change without notice. 888.273.7876 201.767.3400 All brand names, product names, and trademarks are the property of their respective owners. IN GND TX RX RTS CTS R A IN 47 T OU TRON CRES LE CK ., RO EC EL ICS , NJ US 076 IGH INC ON TR IN IN DIO R AU L G + + - -RM DM DIO L AU DIF SP Y MI US G IN DIO R AU L G + + - DIF SG B Y P TU SE SP HD NS A P OU DM M IN 24 IN OM IN C/C EO Pr/ VID /Y Pb G N LA M D DIO L IR G S T OU DM M CO MI AU P TU SE B HID D MI HD 2 B US SE 2 1 GSG S G N LA M CO HD GND TX RX RTS CTS R PW UT INP C DM DD TT iiggii rraa ttaa nn llMM ssm e m ed iitt dii ttee aa rr M D R DM R E O O -R S M M T R C CO 1 ON N 00 T R -F O L L E R Power Supply (Supplied) Power Supply (Supplied) Fiber Cable N LA D T igi ra ta n lM sm e it di te a r Connection to Room Controller (Fiber) 2. Transmitters connected to a DigitalMedia Switcher are configured automatically by the switcher. 3. With a PC connected as shown in the diagram below, use Crestron Toolbox™ to set the IP addresses of the transmitter and room controller or DigitalMedia Switcher. PC/Laptop DigitalMedia Transmitter USB Cable OR USB Cable Room Controller or DigitalMedia Switcher 2 K RIR SHOC OUV TRIC PAS ELEC OPEN OF NE RISK DO NOT IQUE G A 7.0 0V~ -25 Hz 10050/60 Digita lMedia FiberOR Cable DM-TX-Series The 300N/300N-F have front panel controls for making selections. dia M The DM-TX-200 has auto routing functionality by default: • If no signal is present on HDMI IN, RGB IN and AUDIO IN will be routed. • If a signal is present on HDMI IN and no audio is embedded in the video, (i.e., a DVI signal) HDMI IN video and AUDIO IN audio will be routed. • If a signal is present on HDMI IN with audio embedded in the signal, HDMI IN audio and video will be routed. D The DM-TX-100/100-F does not have video switching because there is only one AV input. Me RE Check that the DM input of the room controller or DigitalMedia Switcher are connected to the transmitters, and connect/turn on power. Check the transmitter LEDs, the output display, and verify the signal settings. Check the room controller PWR LED ( on/green). Check the DM LINK LED ( on/green). Check that the VIDEO LED is on/green when a video signal is detected. PW US Connecting AV Sources, Outputs, and Verifying Signals • • • ital G 4 Dig B 1. Configurations with a transmitter connected to a room controller require a power supply, PW-2407RU, connected either to the transmitter or to the room controller. For configurations using DM CAT cables, the power supply must be purchased; for configurations using fiber cable, the power supply is provided. 3. For detailed instructions on the DigitalMedia Room Controller (DM-RMC-100 and DM-RMC-100-F) or the DigitalMedia Switcher, refer to the latest version of their respective guides (Doc. 6743, 6744, and 6755) which can be obtained from the Crestron website (www.crestron.com/manuals). R A NOTE: DigitalMedia cable should have a minimum length of 15 feet (4.6 meters). 2. Configurations with a DigitalMedia Switcher may not require an additional power supply; the switcher typically supplies power for the transmitter. Use the Crestron Power Calculator to verify that there is enough DMNet power on the switcher. Connection to DigitalMedia Switcher OR D 3 24 quickstart guide DigitalMedia™ Transmitters