User Manual Fiber Optic - Bridge and Repeater Document code: MN67182F_ENG Revision 2.000 Page 7 of 13 Industrial Electronic Devices SET SWITCH BAUD RATE FOR “F” SERIES: The switches for setting the CAN0 baud rate and CAN1 on the front panel of the device. Dip n° 1, 2, 3, 4 CAN1 setting Dip n° 5, 6, 7, 8 CAN0 setting Speed CAN1 BPS Speed CAN0 BPS Dip 1 Dip 5 Dip 2 Dip 6 Dip 3 Dip 7 Dip 4 Dip 8 10K 20K 50K 62.5K 100K 125K 250K 500K 800K 1000K ON OFF ON OFF OFF ON OFF ON OFF ON OFF ON ON ON OFF OFF ON ON OFF OFF OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON ON ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31