Download USER MANUAL
Transcript
User Manual: 50 Gallon Smart Foam Unit | English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT Operation Instructions: 1. Verify that the drain plug (DP-A) is securely closed. 2. Follow all instructions from the chemical manufacturer. Fill the tank with water and the advised percentage of chemical concentrate. 3. Verify that the valve (PVCV34FM) at the base of the suction line is open, to allow fluid into the suction line. 4. Verify that the air trigger port is clean and free of blockages or debris, and the discharge hose is not kinked or obstructed. 5. With the wand pointed in a safe direction, connect an air line to the air inlet fitting (AP25). Note: When you connect the air line, listen for any sound from the unit. If you hear the pump activate and begin to cycle, disconnect the air line immediately. This indicates that there is a blockage or other problem somewhere in the system, which could cause the unit to activate spontaneously. The problem must be addressed before proceeding (see “Troubleshooting Instructions”). 6. Place thumb over the air trigger to activate the unit and begin foaming. 7. While the unit is running and discharging product, adjust the needle valve (NV14Y) as needed to regulate the wetness or dryness of the foam following the steps below: a. Close needle valve completely in clockwise direction. b. Open needle valve in counter-clockwise direction 2 complete turns. c. Continue to open needle valve in ¼ turn increments, allowing 30 seconds between adjustments, until desired consistency of foam is achieved. 8. Release the air trigger to stop foaming. Note: When you release the air trigger, the unit will shut off and depressurize. Foam that is already in the discharge hose may seep out, but no more foam will be created until you cover the air trigger again. Maintenance Instructions: To keep your unit operating properly, periodically perform the following maintenance procedures: Note: Before performing any maintenance, ensure that the unit has been disconnected from the air supply according to the “After Use Instructions.” Also ensure that the unit tank is empty, and/or close the valve (PVCV34FM) at the base of the suction line to shut off the flow of liquid from the tank. Reopen the valve after maintenance is complete. • Inspect the air pump (P56/P56K/P56V) for wear and leaks. • Inspect all hoses for leaks or excessive wear. Make sure all hose clamps are in good condition and properly secured. • Check the air trigger port on the handle for debris and clean as needed. When cleaning, be careful not to push debris into the port, as it may become lodged inside and create a blockage. • Clean and replace the filter (AFR25) located within the air regulator (R25) as needed. Access the filter by unthreading the air regulator bowl (ABR25) from the air regulator (R25). • Check the suction line and strainer (STR38-IL) for debris or blockages, and clean as needed. • Drain your air compressor tank on a regular basis to help extend pump life. An air source with a high moisture content will accelerate pump wear. Note: If your air source has a high moisture content, you may wish to install a water separator (WS-20CFM) before the unit. After Use Instructions: 1. Open the drain plug (DP-A) and drain the unit tank. 2. Rinse the unit tank thoroughly with fresh water. Then replace the drain plug and fill the tank with fresh water. 3. Activate the unit and allow it to run for 2-4 minutes, or until all chemical has been flushed from the system. 4. Open the drain plug (DP-A) and drain any water remaining in the unit tank. Then replace and secure the drain plug. 5. Disconnect the air line from the air fitting (AP25). 6. Allow any liquid remaining in the discharge hose to drain out through the discharge wand before storing the unit. Model No.: FI-50N-SM, FI-50NK-SM, FI-50NV-SM AND RELATED UNITS Page 4 of 9 | 03302015