Download Manual Merlin V3
Transcript
Choice of installation Part 4: Installation and Start-up Installation 05 = 2HS controller => 2 HS cascade switched via relay Terminal assignment Sensors Mains 1+GND Outdoor sensor 2+GND Collector sensor 3+GND Storage tank sensor 4+GND Flow sensor Heatcircuit 2 5+GND+6 Optional FBR2 (FBR1) for Heatcircuit 1 6+GND Optional room sensor for Heatcircuit 1 7+GND ---8+GND Flow sensor Heatcircuit 1 9+GND Optional hot-water tank bottom 10+GND - - - 11+GND - - - 12+GND+13 Optional FBR2 (FBR1) for Heatcircuit 2 13+GND Optional room sensor for Heatcircuit 2 14+15 Optional eBUS DCF 16+17 Data line CAN-BUS 18+19 Power supply CAN BUS 20 21 24 25 26 27 28 29+30 32+33 34 35 36 37 38 44 N-conductor, mains Power supply, unit Pump, Heatcircuit 1 Pump, Heatcircuit 2 Storage charging pump Mixing Valve, Heatcircuit 2 open Mixing Valve, Heatcircuit 2 closed HS1 HS2 Mixing Valve, Heatcircuit 1 open Mixing Valve, Heatcircuit 1 closed Pump HS1 Pump HS2 Power supply of relay via fuse (e.g. bridge to 22 = L1´)