Download Notice evolution- FINAL.indd - Height Safety Products and Projects
Transcript
1.5. When a fall arrest system is being used, for safety, it is essential to check the clearance under the user’s working zone to prevent a collision with an obstacle or the ground in case of fall. North American conformity These Lifeline Systems must be rigged in such a way as to limit the free fall to a maximum of 1,8m (6 feet) (ANSI Z359.1-1992) or five feet per ANSI A10.14-1991 for fall arrest systems and zero feet for restraint systems.1.11. In the course of use, take all necessary steps to protect the system or component from hazards related to the operation (burns, cuts, sharp edges, abrasion, chemical attack, tangling or twisting of the cable, webbing or rope, electrical conductivity, weather conditions, pendulum effect due to fall, etc). 1.6. Ensure that a proper rescue plan and the ability to execute it are available for each specific application of the equipment before using it. 1.7. Use this product at an ambient temperature included between –40°C and +60°C. 1.8. Before each use, ensure that the recommendations for use of each of the components is complied with as stated in the user manual.,. It is strongly recommended that components used on the system come from the same manufacturer to ensure product reliability and performance consistency. A. SHARP EDGES: Avoid working where the connecting subsystem (i.e. full body harness, lanyard, self retracting lifeline, etc.) or other system components will be in contact with, or abrade against, unprotected sharp edges. If working with this equipment near sharp edges is unavoidable, protection against cutting must be provided by using a heavy pad or other means over the exposed sharp edge. WARNING: Do not alter or intentionally misuse this equipment; your safety may depend on it. Consult Capital Safety Group when using this equipment in combination with other components or subsystems other than those described in this manual. Some subsystem and component combinations may interfere with the proper operation of this equipment. Use caution when using this equipment around moving machinery and electrical hazards. Use caution when using this equipment around sharp edges and chemical hazards. B. SWING FALLS: Swing falls occur when the anchorage point is not directly above the point where a fall occurs. The force of striking an object while swinging (horizontal speed of the user due to the pendulum effect) can be great and may cause serious injury. Also in a swing fall situation, the total vertical fall distance of the user may be greater than if the user had fallen vertically (directly below the anchorage point). Thus, there will be an increase in the total free fall distance, and the distance needed to arrest the fall will increase. Swing falls can be minimized by working as close to directly below the anchorage point as possible. If a swing fall situation exists in your application, contact Capital Safety Group before proceeding. 1.9. Whenever possible, it is highly advisable to assign the system or component personally to the user. 1.10. This system or component must necessarily be attached to an anchorage point. Whenever possible, to attach a fall arrest system, choose an anchorage point located ABOVE the position of the user, avoiding any point whose strength may be subject to doubt. It is preferable to use the structural anchors provided for this purpose or anchorage points conforming to the current standards when the strength exceeds the strength levels provided for in the corresponding standards. The user will ensure to limit the chances of potential fall from height (prefer the use of a restraint system). C. RESCUE: It is vital that a rescue plan can be implemented should a user fall at any point along the System. It should be assumed that the fallen user will not be able to participate in their rescue. Different rescue solutions apply for different types of applications. Capital Safety Group can recommend a suitable rescue system for each application and, can supply appropriate equipment. For this purpose, any person working at a height must never remain alone at the place of work and after a fall. Australian conformity D. AFTER A FALL: If the System has been used to arrest a fall, further use of the system should be restricted until a Capital Safety Group Technician or factory authorized representative has performed a full site inspection. During the arrest of a, certain components of the system will deform to help dissipate some of the fall’s energy and will require replacement. These Systems must be rigged in such a way as to limit the free fall to a maximum of 2m (AS/NZS 1891.2) for fall arrest systems and zero meter (no fall) for restraint systems. 2 2