Download ESIM110
Transcript
2.7 Output Configuration Output Name Manufacturer default output name: C1 – Controller1. The length of output name can be up to 10 characters including space symbol. Send the following SMS message in order to set a new output name. SMS text: XXXX_C1:NewOutpuName Example: 1111_C1:GATES NOTE: Semi-colon characters, parameter names and/or values are not allowed in output names, eg. PSW, STATUS, ON, OFF etc. Turn ON Output / Output Startup State - NC This feature turns on the output and changes the output startup state to normally closed (NC) at the same time. It is possible to turn on the output by output number or by output name. SMS text: XXXX_C1:ON or XXXX_OutputName:ON Example: XXXX_C1:ON Turn OFF Output / Output Startup State - NO This feature turns off the output and changes the output startup state to normally closed (NC) at the same time. It is possible to turn off the output by output number or by output name. SMS text: XXXX_C1:OFF or XXXX_OutputName:OFF Example: XXXX_Gates:OFF 18