7 Motion Controller
Operation manual mzr-7208, mzr-7208X1
The Controller S-HP is programming with the program
»continuous_flowrate_7208.m«! If you switch S1 the pump runs with approx.
3000 rpm and a flow rate of approx. 140 ml/min. If this parameter are not the
best for the process, please change the parameter in the program!
Notice:
Skilled personnel may only do mounting and initial operating of micro annular
gear pumps.
Check for correct polarity. False connecting may cause severe malfunction or
even destroy the electronic of the motor.
!
Last update: July 2013
Avoid in any case dry running of your micro annular gear pump as this may
especially damage the seals. A short phase of dry running when setting the
pump into operation is negligible.
Technical data subject to change without prior notice!.