Download Owner`s Manual - Smarter Tools
Transcript
Owner’s Manual Troubleshooting _________________________________________________________________________________________________ Problem Cause No Fuel Fill with fuel Generator will not start Faulty spark plug Replace spark plug Unit loaded during start up Remove load from unit Low oil level Fill crankcase to the proper level Place generator on a flat, level surface before restarting Choke in the wrong position. Adjust choke. Spark plug wire loose Attach wire to spark plug Out of fuel Fill fuel tank Low oil level Fill crankcase to the proper level. Place generator on a flat, level surface before starting Generator is overloaded Review load and adjust. See “Power Management” Insufficient ventilation Check for air restriction. Move to a well ventilated area Generator will not start; Generator starts but runs roughly Generator shuts down during operation Generator cannot supply enough power or overheating No AC output Generator gallops Solution Cable not properly connected Check all connections Connected device is defective Replace defective device Circuit breaker is open Reset circuit breaker Capacitor defective Replace capacitor. Contact Smarter Tools Faulty brush assembly Replace brush assembly Contact Smarter Tools Faulty AVR Replace AVR Contact Smarter Tools Loose wiring Inspect and tighten wiring connections Other Contact Smarter Tools Engine governor defective Contact Smarter Tools Overload Review load and adjust. See “Power Management” Faulty cords or device Check for damaged, bare or frayed wires. Replace defective device Repeated circuit breaker tripping 29 ©2009 Smarter Tools, Inc. All Rights Reserved