Download Basic-type Digital Temperature Controller E5AN/E5EN(96 x

Transcript
Monitor/Setting Item Level
25
C
0
Monitor/Setting
Item Display 1
PF
(E5AN/E5EN only)
Monitor/Setting
Item Display 2
Monitor/Setting
Item Display 3
PF
Monitor/Setting
Item Display 4
PF
Monitor/Setting
Item Display 5
PF
Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced function setting level).
Press the O Key for at least 1 s.
alt2
Advanced Function Setting Level
Alarm 2 Type
0.2
2
M
alh3
C
0.2
M
mspu Multi-SP Uses
M
a2lt Alarm 2 Latch
M
spru
M
a3lt Alarm 3 Latch
SP Ramp Time Unit
Alarm 3
Hysteresis
M
Sequence
rest Standby
Reset
M
to Protect Level
prlt Move
Time
M
sb1n
M
sero Input Error Output
off
M
tr-h
Linear output
n-o
Transfer Output
Upper Limit
M
sb2n
100.0
M
Output
tr-l Transfer
Lower Limit
n-o
M
sb3n
0.0
M
o1-t Linear Current Output
4-20
n-o
M
hbu
Linear output
M
of Multi-SP Uses
ev-m Number
Two SPs: 1
none
M
ev-2
stop
on Method
M
Command
rlrv MB
Logic Switching
Auxiliary Output 3
Open in Alarm
off
M
colr PV Change Color
HB ON/OFF
red
off
M
Burnout
hbh Heater
Hysteresis
0.1
Event Input
Assignment 2
M
of Square
sqr Extraction
Root Enable
M
Junction
cjc Cold
Compensation
on
Event Input
Assignment 1
C
0.65
setting/communications
M protect is set to 0.
0.8
Move by setting password (−169).
C
M
at-h AT Hysteresis
0.8
M
a2on Alarm 2 ON Delay
M
a3on Alarm 3 ON Delay
M
a1of Alarm 1 OFF Delay
0
M
a2of Alarm 2 OFF Delay
0
M
Cycle MV
lcma Limit
Amplitude
20.0
M
inf Input Digital Filter
0.0
M
pvad Additional PV Display
off
M
o-dp
M
a1on Alarm 1 ON Delay
0
M
at-g AT Calculated Gain
0 Displayed when initial
5.0
0
M
alfa α
M
to Advanced
amov Move
Function Setting Level:
C
M
pv-b PV Stable Band
0
M
st-b ST Stable Range
15.0
off
M
hsh HS Alarm Hysteresis
0.1
M
a3of Alarm 3 OFF Delay
0
M
istp Input Shift Type
ins1
M
at Stop and Error
mvse MV
Addition
off
MV Display
M
Select
amad Auto/Manual
Addition
off
off
M
Display
ret Automatic
Return Time
0
C
M
rt RT
off
off
M
M
M
lbal LBA Level
(E5AN/E5EN only)
M
pfd2 Monitor/Setting Item 2
M
pfd3 Monitor/Setting Item 3
0
M
pfd4 Monitor/Setting Item 4
0
8.0
C
M
pfd1 Monitor/Setting Item 1
0
M
lba LBA Detection Time
off
Auxiliary Output 2
Open in Alarm
M
hbl Heater Burnout Latch
1 Four SPs: 2
M
ev-1
Auxiliary Output 1
Open in Alarm
PF Setting
(E5AN/E5EN only)
1
off
3
a
tr-t Transfer Output Type
pf
a-m
M
hsl HS Alarm Latch
off
m
HS Alarm Use
on
off
off
M
alt3 Alarm 3 Type
hsu
off
off
M
2
alh2 Alarm
Hysteresis
C
a1lt Alarm 1 Latch
init Parameter Initialization
2
M
pfd5
M
lbab LBA Band
Monitor/Setting Item 5
0
3.0
M
Output 1
out1 Control
Assignment
M
spdp
M
out2
Control Output 2
Assignment
M
odsl MV Display Selection
Auxiliary Output 1
Assignment
M
Decimal Point
pvdp PV
Display
o
none
M
sub1
alm1
M
sub2
Auxiliary Output 2
Assignment
alm3
"PV/SP" Display
Screen Selection
o
on
M
PV Status Display
pvst Function
off
alm2
M
sub3
4
Auxiliary Output 3
Assignment
(E5AN/E5EN only)
M
csel Character Select
on
M
t-u Soak Time Unit
m
M
alsp Alarm SP Selection
sp-m
M
MV
manl Manual
Limit Enable
off
M
Rate of Change
pvrp PV
Calculation Period
4
M
csca
off
Automatic Cooling
Coefficient Adjustment
M
Overcurrent
ocu Heater
Use
on
M
Overcurrent
ocl Heater
Latch
M
Status Display
svst SV
Function
off
M
Refresh
d.ref Display
Period
0.25
M
Output 1
ra1m Control
ON/OFF Count
0 Monitor
M
ra2m
Control Output 2
ON/OFF Count
0 Monitor
M
ra1
Control Output 1
ON/OFF Count
0 Alarm Set Value
M
Output 2
ra2 Control
ON/OFF Count
0 Alarm Set Value
M
Counter
rac ON/OFF
Reset
0
M
to Calibration
cmov Move
Level
0
M
off
M
och
0.1
Heater Overcurrent
Hysteresis
M
Basic-type Digital Temperature Controller
E5AN/E5EN
17