Monitor/Setting Item Level 25 C 0 Monitor/Setting Item Display 1 PF (E5AN/E5EN only) Monitor/Setting Item Display 2 Monitor/Setting Item Display 3 PF Monitor/Setting Item Display 4 PF Monitor/Setting Item Display 5 PF Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced function setting level). Press the O Key for at least 1 s. alt2 Advanced Function Setting Level Alarm 2 Type 0.2 2 M alh3 C 0.2 M mspu Multi-SP Uses M a2lt Alarm 2 Latch M spru M a3lt Alarm 3 Latch SP Ramp Time Unit Alarm 3 Hysteresis M Sequence rest Standby Reset M to Protect Level prlt Move Time M sb1n M sero Input Error Output off M tr-h Linear output n-o Transfer Output Upper Limit M sb2n 100.0 M Output tr-l Transfer Lower Limit n-o M sb3n 0.0 M o1-t Linear Current Output 4-20 n-o M hbu Linear output M of Multi-SP Uses ev-m Number Two SPs: 1 none M ev-2 stop on Method M Command rlrv MB Logic Switching Auxiliary Output 3 Open in Alarm off M colr PV Change Color HB ON/OFF red off M Burnout hbh Heater Hysteresis 0.1 Event Input Assignment 2 M of Square sqr Extraction Root Enable M Junction cjc Cold Compensation on Event Input Assignment 1 C 0.65 setting/communications M protect is set to 0. 0.8 Move by setting password (−169). C M at-h AT Hysteresis 0.8 M a2on Alarm 2 ON Delay M a3on Alarm 3 ON Delay M a1of Alarm 1 OFF Delay 0 M a2of Alarm 2 OFF Delay 0 M Cycle MV lcma Limit Amplitude 20.0 M inf Input Digital Filter 0.0 M pvad Additional PV Display off M o-dp M a1on Alarm 1 ON Delay 0 M at-g AT Calculated Gain 0 Displayed when initial 5.0 0 M alfa α M to Advanced amov Move Function Setting Level: C M pv-b PV Stable Band 0 M st-b ST Stable Range 15.0 off M hsh HS Alarm Hysteresis 0.1 M a3of Alarm 3 OFF Delay 0 M istp Input Shift Type ins1 M at Stop and Error mvse MV Addition off MV Display M Select amad Auto/Manual Addition off off M Display ret Automatic Return Time 0 C M rt RT off off M M M lbal LBA Level (E5AN/E5EN only) M pfd2 Monitor/Setting Item 2 M pfd3 Monitor/Setting Item 3 0 M pfd4 Monitor/Setting Item 4 0 8.0 C M pfd1 Monitor/Setting Item 1 0 M lba LBA Detection Time off Auxiliary Output 2 Open in Alarm M hbl Heater Burnout Latch 1 Four SPs: 2 M ev-1 Auxiliary Output 1 Open in Alarm PF Setting (E5AN/E5EN only) 1 off 3 a tr-t Transfer Output Type pf a-m M hsl HS Alarm Latch off m HS Alarm Use on off off M alt3 Alarm 3 Type hsu off off M 2 alh2 Alarm Hysteresis C a1lt Alarm 1 Latch init Parameter Initialization 2 M pfd5 M lbab LBA Band Monitor/Setting Item 5 0 3.0 M Output 1 out1 Control Assignment M spdp M out2 Control Output 2 Assignment M odsl MV Display Selection Auxiliary Output 1 Assignment M Decimal Point pvdp PV Display o none M sub1 alm1 M sub2 Auxiliary Output 2 Assignment alm3 "PV/SP" Display Screen Selection o on M PV Status Display pvst Function off alm2 M sub3 4 Auxiliary Output 3 Assignment (E5AN/E5EN only) M csel Character Select on M t-u Soak Time Unit m M alsp Alarm SP Selection sp-m M MV manl Manual Limit Enable off M Rate of Change pvrp PV Calculation Period 4 M csca off Automatic Cooling Coefficient Adjustment M Overcurrent ocu Heater Use on M Overcurrent ocl Heater Latch M Status Display svst SV Function off M Refresh d.ref Display Period 0.25 M Output 1 ra1m Control ON/OFF Count 0 Monitor M ra2m Control Output 2 ON/OFF Count 0 Monitor M ra1 Control Output 1 ON/OFF Count 0 Alarm Set Value M Output 2 ra2 Control ON/OFF Count 0 Alarm Set Value M Counter rac ON/OFF Reset 0 M to Calibration cmov Move Level 0 M off M och 0.1 Heater Overcurrent Hysteresis M Basic-type Digital Temperature Controller E5AN/E5EN 17