9. When Moving the Unit
Procedures from Preparing to Move Through Reinstalling
To move the machine, you must completely drain all ink inside the machine and secure the print heads in
place with packing materials to protect them. Attempting to move the machine without first doing this may
result in damage to internal components due to leaking ink or damage to the heads. This operation requires
four unused SOL INK cleaning cartridges. Have these on hand before you start.
Important Notes on Moving
 Be sure to use SOL INK cleaning cartridges. Use of any other type may result in breakdown.
 Once the preparations for moving are complete, move the machine and fill it with ink with
as little delay as possible. Allowing the machine to stand without ink may damage the print
heads.
 When moving the machine, keep it at a temperature between 5 to 40˚C (41 to 104˚F) and at
relative humidity between 20 to 80% (with no condensation). Failure to do so may result in
breakdown.
 Handle the machine with care when moving, keeping it level (not tilted at an angle) and preventing it from striking other objects.
1.


w
x
y

Drain the ink and wash the interior.
Press
.
MENU
SUB MENU
Press
several times until the screen shown on the
left appears.
Press
SUB MENU
INK CONTROL
Press
several times until the screen shown on the
left appears.
Press
in this order.
INK CONTROL
HEAD WASH
Press
CLEANING LIQUID
IS REQUIRED
Make sure the cleaning fluid is ready.
Press
.
CHECK
Discard the discharged ink in the drain bottle.
DRAIN BOTTLE
Be sure to discard the discharged ink.
Press

60
.
.
Thereafter, follow the on-screen instructions to carry out the operations.
After cleaning has finished, the sub power is automatically switched off.
WARNING
Never put discharged fluid or ink closed to fire.
Doing so may cause the blaze.
CAUTION
To store discharged fluid temporarily, keep it in the provided drain bottle
or in a durable container such as a metal can or polyethylene tank, and
close the cap tightly.
Any spillage or vapor leakage may cause fire, odor, physical distress.