Download UT350L Limit Controller User`s Manual

Transcript
● Installation Position
Model UT350L
Limit Controller User’s Manual
Front panel
of controller
Purpose
Must not
exceed 30
Rear of
controller
30
Installation
IM 05D01D21-01E
■ External Dimensions and Panel Cutout Dimensions
Unit: mm
11
100
Initial Settings
Operating
procedures,
troubleshooting,
and maintenance
Operations
General installation
Side-by-side close installation
117 min.
[(N-1)96+92]
+0.8
0
(53)
A2-size paper,
back and front
"N" stands for the number of controllers to be
installed.
However, the measured value applies if N 5.
+0.8
92 0
A2-size paper,
back
Describes key operation sequences.
For operation control through external contact inputs,
see Installation User’s Manual.
92
+0.8
0
(25)
■ How to Install
Turn off the power to the controller before installing it on the panel because there is a possibility of electric shock.
1. Safety Precautions
Large bracket
The following symbol is indicated on the controller to ensure safe use.
Panel
(top mounting hardware)
After opening the mounting hole on the
panel, follow the procedures below to install the controller:
CAUTION
1. Insert the controller into the opening
from the front of the panel so that the terminal board on the rear is at the far side.
Terminal board
Direction to insert the
controller
Insert the controller
into the opening at
the front of the panel.
The following symbols are used in the hardcopy user’s manuals.
Insert a screwdriver into the
brackets to tighten the screws.
NOTE
2. Set the brackets in place on the top and
bottom of the controller as shown in the
figure on the left, then tighten the screws
of the brackets. Take care not to overtighten them.
Indicates that operating the hardware or software in a particular manner may damage it or result in a system failure.
Small bracket
(bottom mounting hardware)
IMPORTANT
Draws attention to information that is essential for understanding the operation and/or features of the controller.
Before using the controller, check that the model and suffix codes match your order.
Limit controller
Type
-0
Optional functions
Standard type
0
1
None
With communication
6. Terminal Wiring Diagrams
This equipment has Measurement category I, therefore do not use the equipment for measurements
within Measurement categories II, III and IV.
•
•
•
•
NC
150mm
150mm
Never place the controller directly on flammable items or equipment.
If the controller has to be installed close to flammable items or equipment, be sure to provide shielding panels all
around the controller, at least 150mm away from every side; the panels should be made of either 1.43mm-thick
metal-plated steel plates or 1.6mm-thick uncoated steel plates.
NOTE
■ For DC Relay Wiring
Number of outputs
1
Output signal
Three terminals (NC, NO, and common)
Contact rating
250V AC or 30V DC, 3A (resistance load)
Resolution
10 ms
UT350L
UT350L
Contact Inputs
Contact Outputs
• Purpose: Alarm output, FAIL output
• Number of outputs: 2
• Relay contact rating: 240 V AC/1 A or 30 V DC/1 A (COM
terminal is common) ; 1a , FAIL output ; 1b
• Devices connected to the UT350L must comply with IEC61010
and 60950.
2
T
1
Outlet
• EMC standards: Complies with EN61326, EN61000-3-2,
EN61000-3-3 and EN55011 (CE).
Class A Group 1.
The instrument continues to operate at a measuring
accuracy of within 20% of the range during tests.
• Construction: Only the front panel is dust-proof and drip-proof
(protection class IP55)
For side-by-side close installation the controller loses its
dust-proof and drip-proof protection.
• Material: ABS resin and polycarbonate
• Case color: Black
• Weight: About 1 kg or less
• Dimensions:
96 (W) 96 (H) 100 (depth from panel face) mm
• Installation: Panel-mounting type. With top and bottom
mounting hardware (1 each)
• Panel cutout dimensions:
(W) 92+0.8
(H) mm
92+0.8
0
0
• Installation position: Up to 30° upward facing
(not designed for facing downward)
• Wiring: M3.5 screw terminals (for signal wiring and power/
ground wiring as well)
RS-485 communication * Wiring can only be carried out
Note :
•The “Installation category” implies the regulation for
impulse withstand voltage. It is also called the
“Overvoltage category.” “II” applies to electrical
equipment.
•“Pollution level” describes the degree to which a
solid, liquid or gas which deteriorates dielectric
strength is adhering. “2” applies to a normal indoor
atmosphere.
• Transportation and storage conditions:
Temperature: -25 to 70C
Temperature change rate: 20C/h or less
Humidity: 5 to 95% RH (no condensation allowed)
• Effects of changes in operating conditions
- Effects from changes in ambient temperature:
- On voltage or thermocouple input, 1 V/C or 0.01%
of F.S./C, whichever is larger
- On RTD input, 0.05C /C (ambient temperature) or less
- On analog output, 0.05% of F.S./C or less
- Effects from power supply fluctuation (within rated voltage
range)
- On analog input, 1 V/10 V or 0.01% of F.S./10 V,
equal to or less than whichever is larger
- On analog output, 0.05% of F.S./ 10 V or less
䊏 Receiving 4-20 mA DC Current
Signals with the Controller
See Initial Settings User’s Manual ,
for more information.
TC input
for controllers with
communication functions.
Maximum baud rate: 9600 bps
2
* When receiving 4-20 mA DC current signals,
RTD input
set the PV input type to 1-5 V DC (setpoint “41”).
11 A
12 +
12 +
12 b
SDA(-)
250 4-20mA
13 -
3
25 RDB(+)
Contact rating: 250 V AC, 3 A
30 V DC, 3 A (resistance load)
26
RDA(-)
27
SG
13 B
13 -
mV/V input
Note: Connecting a 250 resistor to the terminals is
optional.
Model: X010-250-2 (resistor with M3.5 crimp-on terminal
lugs)
12 +
13 1
Alarm-1 output
Alarm-2 output
21
2
Alarm output
11
12
3
23
13
AL1 6
4
24
14
AL2 5
5
25
15
COM 7
6
26
16
7
27
17
UT
External AC power supply
8
18
9
19
10
30
Retransmission output
* PV retransmission is configured at factory
before shipment.
16 +
4-20 mA DC
17 Load resistance: 600 or less
20
R
Power supply
Diode
(Mount it directly
to the relay coil
terminal (socket).)
UT’s contact
Relay
(Use one with a relay coil
rating less than the UT’s
contact rating.)
Power supply
CR filter
(Mount it directly
to the relay coil
terminal (socket).)
L
N
8
CAUTION
Confirmation of limit status
External contact input
Contact +5V
UT
Before carrying out wiring, turn off the power to
the controller and check that cables to be connected
are not alive with a tester or the like because
there is a possibility of electric shock.
9
10
Never touch the opening at the bottom of the case. It is to be used in the factory at shipping.
Distribution board,
circuit breaker, etc.
Overhead wire, cable
systems, etc.
NOTE
External DC power supply
R
UT’s contact
Relay
(Use one with a relay coil rating
less than the UT’s contact rating.)
Environmental Conditions
• Normal operating conditions:
Ambient temperature: 0 to 50C (40C or less for side-by-side
close installation)
The operating ambient temperature range is between 0C.
Temperature change rate: 10C/h or less
Ambient humidity: 20 to 90% RH (no condensation allowed)
Magnetic field: 400 A/m or less
Continuous vibration at 5 to 14 Hz: Full amplitude of 1.2 mm or
less
Continuous vibration at 14 to 150 Hz: 4.9 m/s2 or less
Short-period vibration: 14.7 m/s2, 15 seconds or less
Shock: 147 m/s2 or less, 11 ms
Installation height: Height above sea level of 2000 m or less
Warm-up time: 30 minutes or more after power on
Installation category based on IEC61010-1 : II (See Note)
Pollution degree based on IEC61010-1 : 2 (See Note)
Appliances, portable
equipments, etc.
Construction, Installation, and Wiring
• Purpose: Confirmation of limit output.
• Number of input: 1
• Input type: Non-voltage contact or transistor open collector input
• Input contact rating: 12 V DC, 10 mA or more
• On/off determination: For non-voltage contact input, contact
resistance of 1 k or less is determined as “on” and contact
resistance of 20 k or more as “off.”
For transistor open collector input, input voltage of 2 V or
less is determined as “on” and leakage current must not
exceed 100 A when “off.”
• Minimum status detection hold time: About 1 second.
• Devices connected to the UT350L must comply with IEC61010
and 60950.
Relay contact rating: 240 V AC, 1 A
30 V DC, 1 A (resistance load)
■ For AC Relay Wiring
Internal Wiring
3
Entrance 4
Cable
• Relay contact output (Standard type: terminals 1 - 2 - 3 )
1
Common
150mm
4
PV input
Relay contact output
Relay
150mm
3
Remarks
Description
CAT.1 For measurements performed
on circuits not directly
connected to MAINS.
CAT.2 For measurements performed
on circuits directly connected
to the low voltage installation.
CAT.3 For measurements performed
in the building installation.
CAT.4 For measurements performed
at the source of the low-voltage
installation.
Limit Control Output
Limit control output
COM
NOTE
2
Either PV, or target setpoint is output.
Number of outputs: 1 (terminals 16 - 17 )
Output signal: 4-20 mA DC
Load resistance: 600 or less
Output accuracy: 0.3% of span under standard operating
conditions (23 2C, 55 10% RH, power frequency of
50/60 Hz)
24
1) Provide power from a single-phase instrument power supply. If there is a lot of noise in the power line, insert an
insulating transformer into the primary side of the line and use a line filter (recommended part: ZAC2205-00U
from TDK) on the secondary side.
As a countermeasures against noise, do not place the primary and secondary power cables close to each other.
2) For thermocouple input, use shielded compensating lead wires for wiring. For RTD input, use shielded wires
that have low conductor resistance and cause no significant differences in resistance between the three wires.
The cables to be used for wiring, terminal specifications, and recommended parts are as shown below.
3) Control output relays may be replaced. However, because they have a life of 100,000 times that of the resistance load, use auxiliary relays to turn on/off a load.
4) The use of inductance (L) loads such as auxiliary relays, motors and solenoid valves causes malfunction or
relay failure; always insert a CR filter for use with alternating current or a diode for use with direct current, as
a spark-removal surge suppression circuit, into the line in parallel with the load.
5) When there is the possibility of being struck by external lightning surge, use the arrester to protect the instrument.
1
Signal Isolations
• PV input terminals: Isolated from other input/output terminals.
Not isolated from the internal circuit.
• 4-20 mA analog output terminals (for retransmission): Isolated
from other input/output terminals and internal circuit.
• Relay contact control output terminals: Isolated between contact
output terminals and from other input/output terminals and
internal circuit.
• Contact input terminals: Not isolated between contact input
terminals and from communication terminals. Isolated from
other input/output terminals and internal circuit.
• Relay contact alarm output terminals: Not isolated between
relay contact alarm outputs. Isolated from other input/
output terminals and internal circuit.
• RS-485 communication terminals: Not isolated from contact
input terminals. Isolated from other input/output terminals
and internal circuit.
• Power terminals: Isolated from other input/output terminals and
internal circuit.
• Grounding terminals: Isolated from other input/output terminals
and internal circuit.
Do not use unassigned terminals as relay terminals.
NO
3. How to Install
CAUTION
Fit the cover hold
over the protrusion
on the mounting bracket.
Retransmission Output
• Number of inputs: 1 (terminals 11 - 12 - 13 )
• Input type: Universal input system. The input type can be
selected with the software.
• Sampling period: 250 ms
• Burnout detection: Functions at TC, RTD, standard signal
(0.4 to 2 V or 1 to 5 V)
Upscale, downscale, and off can be specified.
For standard signal, burnout is determined to have occurred
if it is 0.1 V or less.
• Input bias current: 0.05 A (for TC or RTD b-terminal)
• Measurement current (RTD): About 0.13 mA
• Input resistance: 1 M or more for thermocouple or mV input
About 1 M for DC voltage input
• Allowable signal source resistance: 250 or less for
thermocouple or mV input
Effects of signal source resistance: 0.1 V/ or less
2 k or less for DC voltage input
Effects of signal source resistance: About 0.01%/100 • Allowable wiring resistance: for RTD input
Maximum 150 /wire: Conductor resistance between three
wires should be equal
However, 10 /wire for a maximum range of -150.0 to
150.0C.
Wire resistance effect: 0.1C /10 • Allowable input voltage: 10 V DC for thermocouple, mV, or
RTD input
20 V DC for DC voltage input
• Noise rejection ratio: 40 dB (50/60 Hz) or more in normal mode
120 dB (50/60 Hz) or more in common mode
• Reference junction compensation error: 1.0C (15 to 35C)
1.5C (0 to 15C, 35 to 50C)
• Applicable standards: JIS, IEC, DIN (ITS-90) for thermocouples
and RTD
NOTE
Limit controller (of ordered model): .............................................................. 1
Brackets (mounting hardware): ...................................................................... 1 pair
Unit label: ....................................................................................................... 1
User’s Manuals: .............................................................................................. 3 (A2 size)
User’s Manual (Model UT350L Communication Functions): ....................... 1 (A5 size)
Supplied only for UT350L model with communication functions.
To install the controller, select a location where:
(1) no one may accidentally touch the terminals,
(2) mechanical vibrations are minimal,
(3) corrosive gas is minimal,
(4) temperature can be maintained at about 23°C and the fluctuation is minimal,
(5) no direct radiant heat is present,
(6) no magnetic disturbances are caused,
(7) no wind blows against the terminal board (reference junction compensation
element),
(8) no water is splashed,
(9) no flammable materials are around,
Figure A
23 SDB(+)
Check that the following items are provided:
•
•
•
•
•
5. Hardware Specifications
4. How to Connect Wires
1) Before carrying out wiring, turn off the power to the controller and check that the cables to be connected are not
alive with a tester or the like because there is a possibility of electric shock.
2) For safety, be sure to install a circuit breaker switch (of 5A and 100V AC or 220V AC, and that conforms to
IEC60947) near the controller so as to be operated easily, and clearly indicate that the device is used to deenergize the controller.
3) Wiring must be carried out by personnel who have basic electrical knowledge and practical experience.
Description
Fold the cover in the direction
of the arrow.
Figure B
CAUTION
2. Model and Suffix Codes
UT350L
Sales Unit
1
PV Input Signals
CAUTION
This symbol on the controller indicates that the operator must refer to an explanation in the user’s manual in order
to avoid the risk of injury or death of personnel or damage to the instrument. The manual describes how the operator
should exercise special care to avoid electric shock or other dangers that may result in injury or loss of life.
Safety and EMC Standards
• Safety: Complies with IEC/EN61010-1 (CE), approved by
C22.2 No.61010-1, approved by UL508.
Certified for FM-3810 and FM-3545.
Installation category : CAT. II Pollution degree : 2 (IEC/
EN61010-1, C22.2 No.61010-1)
Measurement category : I (CAT. I : IEC/EN61010-1)
Rated measurement input voltage : 10V DC max.(across
terminals), 300V AC max.(across ground)
Rated transient overvoltage : 1500V (Note)
Note : It is a value on the safety standard which is assumed
by IEC/EN61010-1 in Measurement category I, and is not
the value which guarantees an apparatus performance.
Measurement category
145 min.
Power supply: Rated voltage of 100 to 240 V AC (10%), 50/60 Hz
Power consumption: Max. 20 VA (8.0 W max.)
Internal fuse rating: 250V AC, 1.6A time-lug fuse
Data backup: Non-volatile memory (can be written to up to
100,000 times)
• Withstanding voltage
- Between primary terminals* and secondary terminals**:
At least 1500 V AC for 1 minute
- Between primary terminals* and grounding terminal:
At least 1500 V AC for 1 minute
- Between grounding terminal and secondary terminals**:
At least 1500 V AC for 1 minute
- Between secondary terminals**:
At least 500 V AC for 1 minute
* Primary terminals indicate power terminals and relay
output terminals
** Secondary terminals indicate analog I/O signal and
contact input terminals
• Insulation resistance: 20 M or more at 500 V DC between
power terminals and grounding terminal
• Grounding: Class D grounding (grounding resistance of 100 or less)
• PV display:
4-digit, 7-segment red LED display, character height of 20 mm
• Setpoint display: 4-digit, 7-segment red LED display, character
height of 9.3 mm
• Status indicating lamps: LEDs
2. Fit the holes on the top and bottom (UT350L) of the
terminal cover the projections on the brackets (Fig. B)
and lock in place. The figure right shows the attachment
of a terminal cover to UT350L.
+0.8
0
Describes examples of setting PV input types, limit control type A2-size paper,
selection, and alarm types.
front
Making settings described herein allows you to carry out basic
control.
Suffix Code
Part Number
Power Supply Specifications
•
•
•
•
Display Specifications
3.7mm
or
T9115YD
Communication Function
■ Communication protocol
• Personal computer link: Used for communication with a
personal computer, or UT link module of the FA-M3
controller (from Yokogawa Electric Corporation).
• Ladder communication: Used for communication with a ladder
communication module of the FA-M3, or a programmable
controller of other manufactures.
■ Communication Interface
• Applicable standards: Complies with EIA RS-485
• Number of controllers that can be connected: Up to 31
• Maximum communication distance: 1,200m
• Communication method: Two-wire half-duplex, start-stop
synchronization, non-procedural
• Baud rate: 600, 1200, 2400, 4800, or 9600 bps
92
Media
Brief operation,
Contains the parameter map used as a guideline for setting
setpoint recording, Parameters and parameters and lists of parameters for recording user settings.
and
Describes the limit control functions.
description of
Functions
limit control function
Model
0.8 N·m or less
1. Before attaching the terminal cover, bend the side with
the groove inward as shown in Fig. A. Be careful not to
bend it backwards. This not only marks it harder to
attach the cover but will also weaken its hold.
Small bracket
1 to 10 mm (Panel thickness)
■ How to Use the Manuals
Basic operation
Tightening torque
0.3 to 1.65 mm2
Target Model
Introduction
Installation
Shielded wires (three conductors), UL2482 (Hitachi Cable)
Shielded wires
For UT350L
A2-size paper,
front
-
● Terminal Covers (Optional parts)
112
91.8
96
1. Safety Precautions
2. Model and Suffix Codes
3. How to Install
4. How to Connect Wires
5. Hardware Specifications
6. Terminal Wiring Diagrams
Description
-
Other signals
3.7mm
Contents
Describes the tasks (installation, wiring, and others) required
to make the controller ready for operations.
X-
RTD
7 mm or less
96
Manual Title
Shielded compensating lead wires, JIS C 1610,
(See Yokogawa Electric's GS 6B1U1-E.)
Large bracket
This manual describes installation, wiring, and other tasks required to make the controller ready for operation.
Purpose
Thermocouple
Applicable wire size
UT350L
Setup
Power supply, grounding, relay contact outputs 600 V PVC insulated wires, JIS C 3307, 0.9 to 2.0 mm2
● Recommended Terminal Lugs
4th Edition: Apr. 1, 2005
Thank you for purchasing the UT350L limit controller.
The controller is shipped from the factory with 3 hardcopy user’s manuals (A2 size). The 3 user’s manuals in hardcopy
format describe the operating procedures required for basic use. It is recommended that you refer to these user’s manuals to
understand [1] installation, [2] initial settings, [3] operating procedures, and [4] limit control function of the controller.
Name and Manufacturer
7 mm or less
User’s
Manual
● Cable Specifications and Recommended Cables
Install the controller at an angle within 30° from horizontal
with the front panel facing upward. Do not install it facing
downward. The position of right and left sides should be horizontal.
Allowable range: 100 to 240 V AC (10%)
(free voltage)
50/60 Hz shared
RESET when DI=ON
(However, setup parameter
DIS=DI)
DI 19
Transistor contact
DI
19
COM
Common
COM 20
Contact rating: 12 V DC, 10 mA or more
20
IM 05D01D21-01E (1)
IM 05D01D21-01E (2)
User’s
Manual
The following operating procedure describes an example of setting the PV input terminal
controller to a K-type thermocouple (-199.9°F to 999.9°F) and the Thermocouple/mV/V input.............................. 12 - 13
RTD input .................................................. 11 - 12 - 13
measurement range of 0.0°F to 200.0°F.
Model UT350L
Limit Controller User’s Manual
1.
Bring the operating display into view (display
appears at power on).
Initial Settings
IM 05D01D21-02E
10.
Input
Press the
key once to display the parameter
“UNIT” (PV input unit).
Type
Instrument Input
Range Code
Instrument
Input Range
-200 to 1370⬚C
-300 to 2500⬚F
-199.9 to 999.9⬚C
0 to 2300⬚F
-199.9 to 500.0⬚C
-199.9 to 999.9⬚F
-199.9 to 999.9⬚C
-300 to 2300⬚F
-199.9 to 400.0⬚C
-300 to 750⬚F
0.0 to 400.0⬚C
-199.9 to 750.0⬚F
1
Displays
parameter
“UNIT”.
K
2
3
Displays target
setpoint.
J
4
5
This manual describes examples of setting PV input types, limit control types, and alarm types.
Carrying out settings described herein allows you to perform basic control.
Refer to examples of various settings to understand how to set parameters required. Refer to “1. Basic Key Operation
Sequence and Parameter Map” in Parameters and Functions User’s Manual for an easy to understand explanation
of setting various parameters. If you cannot remember how to carry out an operation during setting, press the
key for
more than 3 seconds. This brings you to the display (operating display) that appears at power-on.
2.
Press the
key for more than 3 seconds to
call up the menu “OP.PA”.
SET/ENT
11.
T
Press the
key once to display the parameter
“RH” (maximum value of PV input range).
SET/ENT
6
Displays
parameter
“RH”.
Displays
menu “OP.PA”.
SET/ENT
B
7
S
8
R
9
Thermocouple
Contents
3.
1. Names and Functions of Front Panel Parts
2. Setting PV Input Type
3. Changing Limit Control Type
4. Changing Alarm Type
Press the
“STUP”.
key once to display the menu
12.
Press the
or
key to display the required
setpoint. The figure below shows an example of
setting the maximum value of PV input range to
200.0°F.
Displays menu
“STUP”.
N
10
E
11
L(DIN)
12
1. Names and Functions of Front Panel Parts
14
Blinks during
change.
W
15
Platinel 2
16
PR20-40
17
1. Measured value (PV) display
4.
2. Setpoint display
3. EXCEEDED lamp
5. Alarm indicator lamps
Press the
“PWD”.
SET/ENT
key once to display the parameter
13.
Press the
SET/ENT
key once to register the setpoint.
W97Re3W75Re25
4. Output indicator lamp
8.
6. RESET key
and
30
keys
JPt100
31
7. SET/ENT key
5.
Name of Part
SET/ENT
key once to display the menu
14.
Displays PV.
Displays a parameter symbol when you set a parameter.
Displays an error code (in red) if an error occurs.
2.
Setpoint display
Displays the setpoint (SP) during operation.
Displays the set value of parameters on the parameter setting display.
3.
EXCEEDED lamp
Light (green) to indicate the exceeded status of PV.
Lights while PV exceeds SP.
4.
Output indicator lamp
Light (green) to indicate the output status.
Lights while the relay output is OFF.
5.
Alarm indicator lamps
If any of alarms 1 and 2 occurs, the respective alarm indicator lamp (AL1 and AL2) is lit (in orange).
6.
RESET key
Used to confirm and reset the limit output and related parameters.
7.
SET/ENT
key
Used to switch or register a parameter. Pressing the key for more than 3 seconds allows you to switch
between the operating display and the menu for operating parameter setting display alternately.
and
keys
Used to change numerical values. On setting displays for various parameters, you can change
target setpoints and parameters. Pressing the
key decreases a numerical value,
while pressing the
key causes it to increase. You can hold down a key to gradually increase
the speed of change.
RTD
SET/ENT
Press the
key once to display the parameter
“RL” (minimum value of PV input range).
Function
Measured value (PV)
display
8.
Press the
“FUNC”.
Displays
parameter
“RL”.
Displays
menu “FUNC”.
Press the
key once to display the menu “I/O”.
15.
Press the
or
key to display the required
setpoint. The figure below shows an example of
setting the minimum value of PV input range to
0.0°F.
Displays
menu “I/O”.
Blinks during
change.
7.
Press the
key once to display the parameter
“IN” (PV input type).
SET/ENT
16.
Press the
SET/ENT
key once to register the setpoint.
36
0.4 to 2 V
1 to 5 V
0 to 2 V
0 to 10 V
-10 to 20 mV
0 to 100 mV
40
41
50
51
55
56
37
Standard
signal
DC voltage
6.
35
Pt100
2.
Press the
key once to display the
parameter “AL1” (alarm-1 type).
SET/ENT
Displays
parameter
“AL1”.
7.
Press the
key for more than 3 seconds to
call up the menu “OP.PA”.
SET/ENT
Press the
or
key to display the required
setpoint. The figure below shows an example of
setting PV low limit alarm.
Displays menu
“OP.PA”.
⫾0.1% of instrument range ⫾1 digit for temperatures
equal to or higher than 0⬚C
⫾0.2% of instrument range ⫾1 digit for temperatures
below 0⬚C
3.
Press the
“STUP”.
8.
key once to display the menu
Press the
key once to register the setpoint.
SET/ENT
You can take the same
steps for alarm-2 type
(AL2) that are displayed
after this.
Display menu
“STUP”.
⫾0.2% of instrument range ⫾1 digit
⫾0.1% of instrument range ⫾1 digit
⫾0.5% of instrument range ⫾1 digit for temperatures
equal to or higher than 800⬚C
No guarantee of accuracy for temperatures below 800⬚C
4.
⫾0.2% of instrument range ⫾1 digit
⫾0.1% of instrument range ⫾1 digit (Note1)
9.
Press the
key once to display the
parameter “PWD”.
SET/ENT
Press the
key for more than 3 seconds.
This returns you to the display shown at power-on
(figure below).
SET/ENT
(Note2)
Displays
PV.
⫾0.2% of instrument range ⫾1 digit (Note1)
⫾0.1% of instrument range ⫾1 digit (Note1)
Displays target
setpoint.
(Note2)
⫾0.2% of instrument range ⫾1 digit (Note1)
5.
Press the
“FUNC”.
10. When setting an alarm setpoint, see “3. Setting
key once to display the menu
SET/ENT
Alarm Setpoints” in Operations User’s Manual .
⫾0.1% of instrument range ⫾1 digit
The read-out range can be scaled between -1999 and
9999.
Displays menu
“FUNC”.
■ List of Alarm Types
3. Changing Limit Control Type
1.
Bring the operating display into view (display
appears at power on).
6.
The table below shows the alarm types and alarm actions.
In the table, codes 1 to 10 are not provided with stand-by actions, while codes 11 to 20 are provided with stand-by actions.
Press the
key several times to display the
parameter “HI.LO” (limit control type selection).
Alarm type code
SET/ENT
Alarm action
Alarm type
Displays
parameter
“HI.LO”.
Contact
“Open/close” shows status of relay contact, closes
if alarm
and “lit” and “unlit” shows status of lamp
occurs
No alarm
Alarm type
Contact
“Open/close” shows status of relay contact, closes
if alarm
and “lit” and “unlit” shows status of lamp
occurs
OFF
Open (unlit)
Closed (lit)
PV
11
Alarm setpoint
Open (lit)
■ Setting of Main Parameters at the Factory before Shipment
Item
8.
Factory-set defaults
Thermocouple type K (-300 to 2500⬚F) (1)
Hight limit (HI)
Hour and minute (0)
Alarm-1: PV high limit (1), Alarm-2: PV low limit (2)
PV retransmission (1)
PV input type
Limit control type
Time unit for duration time
Alarm output
Retransmission output
Blinks during
change.
17.
SET/ENT
7.
2
Press the
or
key to display the required
setpoint. The figure below is an example of the
controller set to a low limit type.
PV low limit
Closed (lit)
Alarm setpoint
12
PV
Press the
The controller is configured to the initial value of each parameter at the factory before shipment.
First check the initial values shown in “2. Lists of Parameters,” in Parameters and Functions User’s Manual and
change parameter values as necessary.
key once to register the setpoint.
* If the type of input is voltage, also configure
the PV Input Decimal Point Position (SDP),
Maximum Value of PV Input Scale (SH) and
Minimum Value of PV Input Scale (SL) that are
displayed after parameter RL.
Hysteresis
3
Deviation high
limit
Blinks during
change.
3.
Deviation within
high and low
limits
Closed (lit)
Open (unlit)
PV
Target SP
Deviation setpoint
13
Press the
“STUP”.
key once to display the menu
2500°F
8.
Press the
SET/ENT
Deviation low
limit
key once to register the setpoint.
Closed (lit)
2V
0°F
Minimum value of
PV input range (RL)
800°F
Set a range
to be
controlled
Maximum value of
PV input range (RH)
Parameters to be set for temperature input
1. PV input type (IN): Set according to a sensor
2. Maximum value of PV input range (RH): Set the
maximum value of the range to be controlled.
3. Minimum value of PV input range (RL): Set the
minimum value of the range to be controlled.
5V
Hysteresis Closed Hysteresis
(lit)
Open
(unlit)
Open
(unlit)
Deviation setpoint
Deviation setpoint
Displays menu
“STUP”.
RL
PV input range
RH
Set a range to
be controlled
PV input scale
0.0m3/h
50.0m3/h
Minimum value of
Maximum value of
PV input scale (SL)
PV input scale (SH)
Parameters to be set for voltage input
1. PV input type (IN): Set according to an input signal
2. Maximum value of PV input range (RH): Set the maximum value of an input signal.
3. Minimum value of PV input range (RL): Set the minimum value of an input signal.
4. Position of PV input decimal point (SDP): Set the position of the decimal point for PV input display.
5. Maximum value of PV input scale (SH): Set the maximum value of the scale to be controlled.
6. Minimum value of PV input scale (SL): Set the minimum value of the scale to be controlled.
4.
Press the
“PWD”.
SET/ENT
key once to display the parameter
The controller may automatically initialize the registered operating parameter setpoints if any change is made to the
data item PV Input Type (IN), Maximum Value of PV Input Range (RH), Minimum Value of PV Input Range (RL),
PV Input Decimal Point Position (SDP), Maximum Value of PV Input Scale (SH) or Minimum Value of PV Input
Scale (SL). After a change has been made to any of these data items, be sure to verify the registered operating
parameter setpoints to ensure that they are correct. If any data item has been changed to its default, set it to a
required value.
Closed
(unlit)
9.
Press the
key for more than 3 seconds.
This returns you to the display shown at power on
(figure below).
Hysteresis
10
De-energized
on PV low limit
Deviation
setpoint
PV
SET/ENT
19
Alarm setpoint
15
21
Open (lit)
Alarm setpoint
FAIL output
(Note 2)
Closed
(unlit)
20
PV
The controller stops when in a FAIL state.
The control output is set to “OFF”,
alarm output is set to “OFF” and
retransmission output is set to 0%.
22
Stand-by Action
⬚C
Press the
“FUNC”.
18
5
Open (lit)
SET/ENT
Displays target
setpoint.
PV
8
Open (lit)
PV
Hysteresis
De-energized on
Closed
deviation high
(unlit)
limit alarm
Displays
PV.
5.
17
9
De-energized
on PV high limit
14
PV
Fault diagnosis
Fault diagnosis output
output (Note 1)
NOTE
7
4
Target SP
(input signal)
Instrument
input range
Instrument
input range
PV input range
4V
PV
Hysteresis
Open (unlit)
Example of Voltage Input
1V
Closed
(lit)
Deviation setpoint
Target SP
Target SP
Example of Temperature Input
Hysteresis
Open
(unlit)
Hysteresis
NOTE
-300°F
Closed
(lit)
Target SP
Displays
menu “OP.PA”.
Displays
PV.
Deviation high
and low limits
Open (unlit)
2. Setting PV Input Type
9.
16
PV
Target SP
Hysteresis
Press the
key for more than 3 seconds to
call up the menu “OP.PA”.
Displays target
setpoint.
SET/ENT
6
Closed
(unlit)
Deviation
setpoint
Hysteresis
2.
Contact
opens
if alarm
occurs
Hysteresis
De-energized
on deviation low
limit alarm
1
PV high limit
Alarm type code
Alarm action
Contact
opens
if alarm
occurs
Hysteresis
Displays target
setpoint.
SET/ENT
7
Blinks during
change.
Displays
PV.
Press the
key for more than 3 seconds.
This returns you to the display shown at power-on
(figure below).
Factory-set defaults
).......PV input high limit alarm
).......PV input low limit alarm
7
Displays
PV.
⫾0.1% of instrument range ⫾1 digit
⫾0.25% of instrument range ⫾1 digit for temperatures
below 0⬚C
The following operating procedure describes an example of changing limit control type (factory-set default: high limit type)
to low limit type.
The controller automatically returns to the display at the time of power-on (i.e., operating display) if no key is
operated for at least one minute.
Press the
or
key to display the required
setpoint. The figure below is an example of the
controller set to a Pt100 resistance temperature
detector (-199.9°F to 999.9°F).
5
-
*
Performance in the standard operationg condition (at 23⫾2⬚C, 55⫾10%RH, and 50/60Hz power frequency)
Note1: The accuracy is ⫾0.3⬚C of instrument range ⫾1 digit for a temperature range from 0⬚C to 100⬚C.
Note2: The accuracy is ⫾0.5⬚C of instrument range ⫾1 digit for a temperature range from -100⬚C to 200⬚C.
*
To receive a 4-20 mA DC signal, select a standard signal of 1 to 5 V DC and connect it to a 250⍀ resistor. This resistor is optional.
Model: X010-250-2 (resistor with M3.5 crimp-on terminal lugs)
Displays
parameter “IN”.
IMPORTANT
⫾0.15% of instrument range ⫾1 digit
0 to 2000⬚C
32 to 3600⬚F
-199.9 to 500.0⬚C
-199.9 to 999.9⬚F
-150.0 to 150.0⬚C
-199.9 to 300.0⬚F
-199.9 to 850.0⬚C
-300 to 1180⬚F
-199.9 to 500.0⬚C
-199.9 to 999.9⬚F
-150.0 to 150.0⬚C
-199.9 to 300.0⬚F
0.400 to 2.000 V
1.000 to 5.000 V
0.000 to 2.000 V
0.00 to 10.00 V
-10.00 to 20.00 mV
0.0 to 100.0 mV
6.
Bring the operating display into view (appears at
power-on).
6
Displays target
setpoint.
0 to 1700⬚C
32 to 3100⬚F
0 to 1700⬚C
32 to 3100⬚F
0 to 1900⬚C
32 to 3400⬚F
18
1.
⫾0.1% of instrument range ⫾1 digit for temperatures
equal to or higher than 0⬚C
⫾0.2% of instrument range ⫾1 digit for temperatures
below 0⬚C
⫾0.15% of instrument range ⫾1 digit for temperatures
equal to or higher than 400⬚C
⫾5% of instrument range ⫾1 digit for temperatures
below 400⬚C
-199.9 to 999.9⬚C
-300 to 1800⬚F
-199.9 to 900.0⬚C
-300 to 1300⬚F
-199.9 to 400.0⬚C
-300 to 750⬚F
0.0 to 400.0⬚C
-199.9 to 750.0⬚F
0 to 2300⬚C
32 to 4200⬚F
0 to 1390⬚C
32 to 2500⬚F
13
Measurement Accuracy
0 to 1800⬚C
32 to 3300⬚F
-200 to 1300⬚C
-300 to 2400⬚F
U(DIN)
1.
4. Changing Alarm Type
The following operating procedure describes an example of chang- Alarm output terminals
ing alarm-1 (factory-set default:PV high limit alarm) to PV low limit Alarm-1 (terminal numbers
alarm.
Alarm-2 (terminal numbers
When you have changed alarm type, the alarm setpoint will be initialized; set the alarm setpoint again.
Select the unit from the UNIT parameter.
SET/ENT
Displays
PV.
4th Edition: Apr. 1, 2005
■ Instrument Input Range Codes
Treated
as normal
key once to display the menu
Normal
Abnormal
The alarm
output turns on.
Low limit of
alarm setpoint
The alarm output does not
turn on in this region even
if the PV value is below the
low limit of the alarm setpoint.
Displays
menu “FUNC”.
Power-on
Time
Note 1: The fault diagnosis output turns on in case of input
burnout, A/D converter failure, or reference junction compensation (RJC) failure. In case of RJC
failure, the controller continues control under the
condition of “RJC=OFF”.
Note 2: The FAIL output is on during normal operation and
turn off in case of ROM failure, RAM failure, power
failure.
IM 05D01D21-02E (1)
3. Setting Alarm Setpoints
User’s
Manual
Model UT350L
Limit Controller User’s Manual
Operations
IM 05D01D21-02E
1.
Bring the operating display into view (display
appears at power on).
Press the
setpoint.
4.
or
6
5
-
7
7
Factory-set defaults
)............PV high limit alarm
)............PV low limit alarm
Following parameters can be seen in the confirmation display. These parameters can be confirmed and reset by pressing the
key at each parameter display.
key to display the required
1.
Displays PV.
Bring the operating display (PV/SP dispaly) into
view (display appears at power on).
Displays
target setpoint.
When the instrument is specified as high limit type,
go to the step 4.
When the instrument is specified as low limit type, go
to the step 5.
Blinks during
change.
4.
Displays PV.
2.
Press the
key for more than 3 seconds to call
up the menu “OP.PA”.
SET/ENT
Press the
5.
SET/ENT
key once to register the setpoint.
SET/ENT
Contents
1. Monitoring-purpose Operating and Confirmation Displays Available during Operation
2. Setting Target Setpoint (SP)
3. Setting Alarm Setpoints
4. Confirmation of the Limit Output
5. Operation in Confirmation Display
6. Troubleshooting
7. Cleaning and Maintenance
Displays
target setpoint.
Displays menu
“OP.PA”.
3.
Press the
“A1”.
SET/ENT
key twice to display the parameter
NOTE
<For “high limit” type>
Press the
key. If the controller is specified
as high limit type, “HI” will be displayed.
The maximum value of PV that has been measured
up to now is shown in the SP display.
(E002)
System data error 0%
None
0% or less
0% or less
or OFF
Stopped
OFF
0%
Normal action Normal action Normal action Normal action
Normal
(out of
(out of
(out of
(out of
action
accuracy)
accuracy)
accuracy)
accuracy)
Faulty calibration
value
Press the
key if reset is designated.
If you don't want to reset, just go to the step 6.
(E400)
Parameter error
0%
OFF
OFF
Remedy
Faulty
Contact us
for repair.
Check and set
the parameters,
as they have
been set to the
limited values.
0%
■ Possible Errors during Operation
6.
PV
Control
output
Alarm
output
Retransmis- Commusion output nication
Press the
key for more than 3 seconds.
This returns you to the display shown at power-on
(figure below).
Displays “RJC”
and PV
alternately
Measured
with RJC=0
Normal
action
Normal
action
Normal
action
Normal
action
Normal action
Normal
action
Normal
action
Normal
action
Normal
action
105%
Normal
action
Normal
action
Normal
action
Normal
action
Dependent on the BSL
parameter Up-scale: 105%
Down-scale: -5%
Normal
action
Normal
action
Normal
action
Normal
action
Check wires and
sensor.
Normal
action
Normal
action
Normal
action
Normal
action
Check process.
Normal
action
Normal
action
Normal
action
Normal
action
Check wires and
communication parameters,
and make resetting.
Recovery at normal receipt
0% or
less
Stopped
Faulty if power off/on does
not reset start the unit.
Contact us for repair.
0%
Stopped
Check for abnormal power.
SET/ENT
Displays PV.
2.
Press the
“TIME”.
key once to display the parameter
SET/ENT
5.
The SP display shows the duration time after PV
exceeds SP. If “0.00” shows here, PV has not
exceeded SP or the time is already confirmed.
Displays
target setpoint.
<For “low limit” type>
Press the
key. If the instrument is specified
as a low limit type, “LO” will be displayed.
The minimum value of PV that has been measured
up to now is shown in the SP display.
SET/ENT
Displays
parameter
“TIME”.
4. Confirmation of the Limit Output
1.
Bring the operating display (PV/SP display or SP
only display).
3.
(E300)
A/DC error
(OVER) or Excessive PV -5% or 105%
(-OVER) Out of -5 to
105%
If you want to confirm and reset the duration time,
press the
key for about one second.
The duration time will be reset.
If you don't want to reset the time, just move to the
next step.
6.
Press the
key once to display the operating
display (PV/SP display).
SET/ENT
Faulty
communication line
Normal action
All indications off Runaway (due None
to defective
power or
noise)
0% or less OFF
or OFF
All indications off Power off
0%
None
OFF
Remedy
Faulty
Contact us for repair.
Displays PV.
Press the
key for about one second. Confirm
that the OUT lamp becomes OFF.
The output has been on.
Displays
“0.00”
Ex.) SP=120.0, PV=125.0, Hysteresis=5
Operating Display
PV value blinks. EEPROM
error
SP decimal
point blinks.
(on setpoint
display unit)
3.
RJC error
(B.OUT) PV burnout
error
Press the
key if reset is designated.
If you don't want to reset, just go to the step 6.
See “3. Description of Limit Control Functions” in Parameters and Functions User’s Manual .
Here explains the way to reset key operation.
Not displayed
Faulty ROM
Retransmission Communication
output
Error indication Description
(on PV display of error
unit)
Procedure 1) The exceeded lamp lights, and also the output lamp lights.
Procedure 2) Exceeded lamp is off when the PV recovers to the normal status where PV doesn’t exceed SP, while OUTPUT
lamp keeps lit until the confirmation is done.
Procedure 3) Confirmation of the limit output can be done either by a front panel or external contact input.
When setup parameter OP.SL is
set to 1.
Faulty RAM
(E001)
Alarm
output
SET/ENT
When the measured value (PV) exceeds the setpoint for limit control (SP).
When setup parameter OP.SL is
set to 0.
(factory-set default)
Measured input
value (PV)
(E000)
PV decimal point blinks.
Control
output
PV
Also configure the Alarm-2 Setpoint (A2) parameter
that follows this step.
Do not use the instrument generating strong magnetic field such as radio equipment and the like near the controller.
This may cause the fluctuation of the PV value.
Power on
Description
of error
The following shows possible errors occurring during operations.
Displays
parameter
“A1”.
1. Monitoring-purpose Operating Confirmation Displays Available during Operation
The following table shows errors that may be detected by the fault diagnosis function when the power is turned on.
Error indication
(on PV display unit)
● Duration time (TIME)
● Maximum value of PV (HI) or Minimum value of PV (LO)
4th Edition: Apr. 1, 2005
This manual describes key entries for operating the controller. For operations using external contact inputs. See “6. Terminal
Wiring Diagrams” in Installation User’s Manual . If you cannot remember how to carry out an operation during
key for more 3 seconds. This brings you to the display (operating display) that appears at power-on.
setting, press the
■ Errors at Power On
5. Operation in Confirmation Display
The following operating procedure describes an example of setting Alarm output terminals
160.0 to alarm-1 setpoint. Check alarm type before setting the alarm Alarm-1 (terminal numbers
setpoint. To change the type of alarm, see “4. Changing Alarm Type” Alarm-2 (terminal numbers
in Initial Settings User’s Manual .
Displays
target setpoint.
■ If a Power Failure Occurs during Operation
● Momentary power failures shorter than 20 ms
The controller is not affected at all and continues normal operation.
Displays PV.
Target
Setpoint
PV / SP display
SP only display
EXCEEDED lamp
is lit.
Target
Setpoint
Displays
target setpoint.
OUT lamp
is lit.
SET/ENT
SET/ENT
SET/ENT
key
key
2.
key
● Power failures of 20 ms or longer
EXCEEDED lamp
is off.
OUT lamp
is off.
• The alarm function of the controller continues to work normally. (Alarms with the stand-by feature temporarily return
to their stand-by state, however.)
• Setting parameters that have already been configured retain their settings.
• After recovery from a power failure, limit control status is reset.
6. Troubleshooting
■ Troubleshooting Flow
If the operating display does not appear after turning on the controller’s power, follow the measures in the procedure below.
If a problem appears complicated, contact our sales representative.
Comfirmation
If your control tasks are not successful, check the preset parameters and controller wiring before concluding the controller
to be defective. The following show examples of troubleshooting you should refer to in order to avoid the possibility of
other problems.
Is the instrument
defective?
Confirm that the EXCEEDED lamp is off and the
OUT lamp is lit.
OUT status cannot be reset while the EXCEEDED
lamp is lit.
Yes
No
Totally
inoperable?
Ex.) SP=120.0, PV=115.0, Hysteresis=5
Is key
operation
faulty?
Yes
Yes
No
Is display
faulty?
No
Is I/O
signal faulty?
Yes
Is
communication
link faulty?
No
Yes
Yes
Displays PV.
EXCEEDED lamp
is off.
Duration time display
SET/ENT
key
SET/ENT
When limit control type is
set as high limit.
(factory-set default)
Check the key lock
setting.
Check the supply
voltage.
OUT lamp
is lit.
Confirmation Display
key
Check wiring on the
power supply
terminals.
Displays
target setpoint.
When limit control type is
set as low limit.
Turn off power, and
then turn it on again.
Check the
instrument’s I/O
specifications.
Correct
errors.
■ Confirmation of Limit Status
Limit control output and related parameter such as duration time and maximum / minimum PV value can be confirmed by a
front key operation. It is possible to confirm limit control output by using external contact input. The way of confirmation
is set by setup parameter DIS.
Table blow shows the item which can be confirmed by front key or external contact input according to the setting of DIS.
Minimum value display
Item to be confirmed
2. Setting Target Setpoint (SP)
The following operating procedure describes an example of setting 120.0 to a target setpoint.
Bring the operating display into view (display
appears at power on).
Displays PV.
3.
Press the
SET/ENT
key once to register the setpoint.
DIS parameter = KEY
Is
key lock
enabled?
Yes
No
Yes
Yes
Disable
key lock.
DIS parameter = DI
Output relay
KEY
Able
DI
Disable
KEY
Disable
DI
Able
Duration time
Able
Disable
Able
Disable
Maximum / Minimum value
Able
Disable
Able
Disable
Does the code
include a communication
option?
No communication
capability.
Check the
communication-related
parameters.
• The UT350L controllers have a universal input.
The type of PV input can be set/changed using the parameter “IN”. At this point, the controller must be wired correctly
according to the selected type of PV input. Check the wiring first if the controller fails to show the correct PV. To do
this, refer to Initial Settings User’s Manual .
With the parameters “RH”, “RL”, “SDP”, “SH” and “SL”, it is possible to scale the input signal and change its number
of decimal places. Also check that these parameters are configured correctly.
7. Cleaning and Maintenance
Find the cause.
Use a dry cloth and wipe gently to clean the product’s front panel, keys, and other areas.
NOTE
Check
communication wiring.
Check the specifications
of communication
counterpart.
Correct?
Ask the vendor for repair.
No
● The controller does not show the correct measured value (PV).
■ Cleaning
No
No
1.
Check the
instrument's suffix
code.
Check the specifications
of I/O counterpart for
wrong polarity.
Normal?
Maximum value display
■ Troubleshooting When the Controller Fails to Operate Correctly
Do not use solvents such as alcohol or benzine.
■ Replacing the Mounting Bracket
If the mounting bracket is damaged or lost, order a replacement using the following serial number and sales unit.
Part No.
Sales Unit
T9115NL
One pair (upper and lower bracket)
IMPORTANT
■ Limited Life Componets and Maintenance
Take note of the parameter settings when asking the vendor for repair.
The parts used in this product that have an especially limited life are shown below.
Part No.
Service Life
Aluminum electrolytic capacitor
About 10 years (Estimated)
Non-volatile memory
Can be written to up to 100,000 times
Alarm output relay
100,000 times
Limit control output relay (Note)
100,000 times
Note) Limit control output relay can be replaced by users.
Displays
target setpoint.
2.
Press the
setpoint.
or
key to display the required
Blinks during
change.
IM 05D01D21-02E (2)
Description of Operating Parameter Menu Display
User’s
Manual
Model UT350L
Limit Controller User’s Manual
Description of Setup Parameter Menu Display
Displays the
operating
parameter
menu symbol
“OP.PA”.
2. Lists of Parameters
Nothing appears.
Nothing appears.
Parameter
Symbol
Parameters and Functions
IM 05D01D21-03E
■ Setup Parameters
■ Operating Parameters
Displays the
setup
parameter
menu symbol
“FUNC” or “I/O”.
● Control Function-related Parameters
Name of Parameter
Target setpoint
Setting Range and Description
0.0 to 100.0% of PV input range
Initial Value
0.0% of PV input range
User Setting
Parameter
Symbol
Alarm-1 type
(SP)
4th Edition: Apr. 1, 2005
Alarm-1 setpoint
Description of Operating Parameter Setting Display
Description of Setup Parameter Setting Display
(A1)
This manual contains a parameter map as a guideline for setting parameters, and lists of parameters for recording User
Settings.
Displays a
parameter
symbol.
Alarm-2 setpoint
Displays a
parameter
symbol.
(A2)
PV input filter
Displays a
setpoint.
Contents
Displays a
setpoint.
OFF, 1 to 120 seconds.
Used when the PV input fluctuates.
PV high limit alarm:
100.0% of PV input range
Deviation alarm: 0.0% of PV
input range span
Other PV low limit alarm:
0.0% of PV input range
(AL1)
Alarm-2 type
(AL2)
Alarm-1 hysteresis
OFF, 1 to 22
1: PV high limit (energized, no stand-by action)
2: PV low limit (energized, no stand-by action)
3: Deviation high limit (energized, no stand-by action)
4: Deviation low limit (energized, no stand-by action)
5: Deviation high limit (de-energized, no stand-by action)
6: Deviation low limit (de-energized, no stand-by action)
See “List of Alarm Types” in Initial Settings User’s Manual .
0.0 to 100.0% of PV input range span
OFF
Hysteresis for PV high limit alarm
Output
(HY1)
(FL)
PV input bias
1. Basic Key Operation Sequence and Parameter Map
2. Lists of Parameters
3. Description of Limit Control Functions
4. Parameters in the Confirmation Displays
5. Function Block Diagram
PV alarm: -100.0 to 100.0% of PV input range
Deviation alarm: -100.0 to 100.0% of PV input
range span
Setting Range and Description
Name of Parameter
-100.0% to 100.0% of PV input range span
Used to correct the PV input range.
0.0% of PV input range
span
0.0 to 100.0% of PV input range span
0.5% of PV input range span
?
(H)
User Setting
1
2
0.5% of PV
input range span
Point of
on-off action
(Alarm setpoint)
On
Alarm-2 hysteresis
(BS)
Limit control output
hysteresis
Initial Value
Off
Hysteresis
(HY2)
In case of HIGH LIMIT
Limit control type selection
HI: High limit, LO: Low limit
Restart mode
0: Limit output is ON at power on in any cases,
1: Limit output is OFF at power on when PV doesn’t
exceed SP
Operating display
selection
0: PV/SP display first,
1: SP only display first
0
Time unit for duration time
0: hour and minute
1: minute and second
0
Protocol selection
0: PC link communication
1: PC link communication (with sum check)
2: Ladder communication
Baud rate
0: 600, 1: 1200, 2: 2400, 3: 4800, 4: 9600 (bps)
HI
Output
If you become unsure of key operation during parameter
setting, hold down the
key for more than 3 seconds.
This returns you to the display at power-on
(i.e., operating display).
SP
(HI.LO)
On
SET/ENT
1. Basic Key Operation Sequence and Parameter Map
Hysteresis
Off
(R.MD)
Power on
PV
In case of LOW LIMIT
(OP.SL)
Output
SP
Operating Display
On
Confirmation Display
0
(TMU)
Off
Measured input
value (PV)
Hysteresis
When limit control type is
set as “high limit.”
(factory-set default)
When setup parameter
OP.SL is set to “ 0.”
(factory-set default)
SET/ENT
SET/ENT
key
PV / SP display
PV
SET/ENT
key
(P.SL)
0
4
key
(BPS)
Target
Setpoint
Parity
Maximum value display
(PRI)
Not displayed
Stop bit
0: None
1: Even
2: Odd
1
1, 2
1
SET/ENT
SET/ENT
Duration time display
key
SET/ENT
When setup parameter
OP.SL is set to “ 1.”
SP only display
(STP)
key
When limit control type is
set as “low limit.”
key
Data length
7, 8:
Fixed at 8, when the P.SL parameter is set to Ladder Communication.
Address
1 to 99
However, the maximum number of stations connectable
is 31.
Minimum response
time
0 to 10 (⫻ 10 ms)
8
(DLN)
Target
Setpoint
Minimum value display
(ADR)
1
0
(RP.T)
● Input-/Output-related Parameters
SET/ENT
key
Press this key for more
than 3 seconds to
move to the operating
parameter setting
display.
Parameter
Symbol
Basic Key Operation Sequence
key
SET/ENT
Press this key for
more than 3 seconds
to move to the
operating
display.
1. Setting display can be switched (moved) using the
key.
SET/ENT
2. A numerical value is changed by
(1) Using the
or
(2) Pressing the
3. Pressing the
Operating Parameter Setting Display
SET/ENT
SET/ENT
(IN)
key to change a displayed value (decimal point blinking) and
SET/ENT
PV input type (INPUT
terminals)
11 - 12 - 13 terminals
PV input unit
key to register it.
(UNIT)
key on an operating display (for more than 3 seconds) brings you to the
Max. value of PV input
range
operating parameter setting display.
4. Pressing the
Name of Parameter
key on the operating parameter setting display (for more than 3 seconds)
(RH)
returns you to the operating display.
or
key
SET/ENT
SET/ENT
5. Pressing the
key
SET/ENT
Min. value of PV input
range
key on the setup parameter setting display (for more than 3 seconds)
SET/ENT
returns you to the operating display.
key
Password input
You cannot return to the operating parameter setting display from the setup parameter setting
(No password is required
when PWD = 0.)
display.
SET/ENT
key
Target setpoint
Alarm-1 setpoint
Not displayed when AL1=OFF.
Alarm-2 setpoint
Not displayed when AL2=OFF.
key
Press this key for
more than 3 seconds
to move to the
operating
display.
Setup Parameter Setting Display
Control function
related
(RL)
or
PV input bias
SET/ENT
SET/ENT
key
To switch the parameter display, press the
SET/ENT
SET/ENT
Alarm-1 type
Alarm-2 type
PV input unit
Alarm-1 hysteresis
Maximum value of PV
input range
Alarm- 2 hysteresis
Minimum value of PV
input range
Limit control type selection
PV input
decimal point position
Restart mode
Maximum value of
PV input scale
Operating display selection
Minimum value of
PV input scale
Time unit for duration time
Presence/absence of PV input
reference junction compensation
Protocol selection
Selection of PV input
burnout action
Baud rate
Retransmission
output type
Parity
Maximum value of
retransmission output scale
key.
NOTE
Stop bit
Changing the registered value of a setup parameter
may cause the registered value of an operating parameter to be initialized automatically. Thus, when
you have changed a setup parameter, always check
that the registered value of the operating parameter
is appropriate. If it is initialized to default, reset it to
the required value.
SET/ENT
key
Displayed only for controller with
communication functions.
Max. value of
instrument
input range
Min. value of
instrument
input range
-1999 to 9999, however SL < SH
Set the read-out scale of voltage-mode PV input.
100.0
(SH)
Max. value of PV input
scale
(displayed at voltage input)
(SL)
Min. value of PV input
scale
(displayed at voltage input)
(SDP)
key
PV input type
(INPUT terminals)
⬚F
1
key
key
(This parameter is not shown for voltage input.)
Set the PV input range, however RL < RH.
-Temperature input
Set the range of temperature that is actually controlled.
- Voltage input
Set the range of a voltage signal that is applied.
The scale across which the voltage signal is actually controlled
should be set using the parameters Maximum Value of PV Input
Scale (SH) and Minimum Value of PV Input Scale (SL).
Presence/absence of
PV input reference
junction compensation
Selection of PV input
burnout action
(BSL)
Retransmission output
type
User Setting
1
0 to 3
Set the position of the decimal point of voltage-mode PV input.
0: No decimal place
1: One decimal place
2 , 3: Two, three decimal places
(RJC)
Limit control output
hysteresis
OFF, 1 to 18, 30, 31, 35 to 37, 40, 41, 50, 51, 55, 56
See Instrument Input Range Codes in Initial Settings
User’s Manual .
⬚C: degree Celsius
⬚F: Fahrenheit
Initial Value
PV input decimal point
position (displayed
at voltage input)
Input/output
related
PV input filter
Setting Range and Description
0.0
OFF, ON
ON
OFF
1: Up scale
2: Down scale
1: PV, 2: SP
1
1
(RET)
(RTH)
(RTL)
Displayed at voltage input.
Max. value of
retransmission output
scale
Min. value of
retransmission output
scale
The way of confirmation
RTL + 1 digit to 100.0% of PV input range
100.0% of
PV input range
0.0% of PV input range to RTH - 1 digit
0.0% of
PV input range
KEY
KEY: By key operation.
DI: By contact output, only the limit output can be confirmed.
(DIS)
Key lock
OFF: No key lock
ON: Change to any parameter prohibited
Prohibits any operating parameter or setup parameter from
being changed.
The setpoint of the LOCK parameter itself can be changed,
however.
OFF
Password setting
0: Password not set
1 to 9999
0
(LOCK)
(PWD)
Minimum value of
retransmission output scale
Data length
The way of confirmation
Address
Key lock
Minimum response time
Password
SET/ENT
key
IM 05D01D21-03E (1)
■ Power on Status
3. Description of Limit Control Functions
4. Parameters in the Confirmation Displays
5. Function Block Diagram
The state of output relay at power-on can be set by a setup parameter restart mode R.MD.
■ In Case of High Limit Control
When a measured value (PV) exceeds a setpoint (SP). “EXCEEDED” lamp lights, and “OUT” lamp turns ON (point A). The limit control
output relay is de-energized then.
“EXCEEDED” lamp turns off when PV goes into normal condition, while “OUT” lamp stays on as it is (point B). “OUT” lamp turns off
when a confirming operation is done by an operator (point C). The way to confirm is pushing the “RESET” key (or by an exeternal contact,
according to the setting of setup parameter DIS). The confirming operation is not accepted during PV exceeds SP (point D). State of output
relay is de-energized whenever “OUT” lamp is on. (NC terminal : CLOSE, NO terminal : OPEN)
(A)
(B)
(C)
(A)
(D)
■ Duration Time
Setup Parameters
Restart mode R.MD :
0 : Limit output relay is de-energized at power on.
1 : Limit output relay is energized at power on.
The time while PV exceeds SP is counted and stored in the memory. It is displayed in the “TIME” display in the confirmation display.
Display time range : 0.00 to 99.59
● When parameter R.MD is set to 0.
PV INPUT
DI
19 and 20
Input selection
- To RESET
- Push “RESET” key for about one second to reset the duration time in the confirmation display where “TIME” is displayed.
When the count are reset, “0.00” is displayed until PV exceeds SP again.
- The time count are reset when power is turned on.
- If PV exceeds SP during the old time count data is retained in the memory, the old data should be automatically reset, and the
new time counting starts from “0.00”.
- It is impossible to reset the time count while PV exceeds SP by any operation.
- Duration time cannot be reset by an external contact input.
In Case of High Limit Control
(A)
Contact input
terminals
Unit of time is be either “hour.minute” or “minute.second”, and can be set by setup parameter TMU.
The limit output relay is always de-energized at power on, even if PV doesn’t exceed SP (point A). (NC terminal : CLOSE, NO terminal :
OPEN). “OUT” lamp is lit. After the confirmation, state of output relay is energized (NC terminal : OPEN, NO terminal : CLOSE) and “OUT”
lamp turns off, if the PV doesn’t exceed SP (point B).
(B)
PV input
terminals
11 , 12 and 13
(B)
SP
DIS
IN
Unit selection
UNIT
Input range conversion
RH,RL
Input bias
BS
Input filter
FL
SDP, SH, SL
Hysteresis
PV
■ Maximum / Minimum Value
SP
The maximum value or minimum value of PV is stored in the memory and display in the “HI” or “LO” display in the confirmation display.
When the control type is specified as high limit control, the maximum value is displayed in the “HI” display, and control type is specified as
low limit control, the maximum value is displayed in the “LO” display.
When the PV exceeds SP and then returns to the normal status, Maximum / Minimum Value is retained as it is , but when PV exceeds SP again,
it is automatically reset and starts taking new value for its minimum / maximum value.
Hysteresis
EXCEEDED
Lamp
off
OUT
Lamp
off
Output Relay
off
lit
off
lit
off
on
off
lit
PV
lit
off
on
- To RESET
EXCEEDED
Lamp
OUT
Lamp
off
off
Operation
(RESET key or
external contact input)
■ In Case of Low Limit Control
When a measured value (PV) exceeds a setpoint (SP). “EXCEEDED” lamp lights, and “OUT” lamp turns ON (point A). The limit control
output relay is de-energized then.
“EXCEEDED” lamp turns off when PV goes into normal condition, while “OUT” lamp stays on as it is (point B). “OUT” lamp turns off
when a confirming operation is done by an operator (point C). The way to confirm is pushing the “RESET” key (or by an exeternal contact,
according to the setting of setup parameter DIS). The confirming operation is not accepted during PV exceeds SP (point D). State of output
relay is de-energized whenever “OUT” lamp is on. (NC terminal : CLOSE, NO terminal : OPEN)
(B)
(C)
off
lit
on
- Push the “RESET” key for about one second to reset the maximum / minimum value in the confirmation display where “HI” or
“LO” is displayed. The value is reset, and the value immediately after the confirmation should be recognized as a maximum or
minimum value.
- When the power is turn on, the memory should be reset and the first PV should be recognized as maximum.
- Maximum / Minimum value cannot be reset by an external contact input.
- It is impossible to reset the maximum / minimum value while PV exceeds SP by any operation.
off
(A)
(D)
Target setpoint
PV dispay
RET
RTH
RTL
Retransmission
output
HI.LO
Limit control
H
PV or SP
AL1
AL2
A1
A2
HY1
HY2
Alarm function
Limit
control
output
RET
OUTPUT
Current
terminals
16 and 17
Relay
terminals
1 , 2 and 3
AL1
on
Confirmation
(not accepted)
Confirmation
(accepted)
(A)
off
lit
off
Output Relay
Operation
(RESET key or
external contact input)
lit
SP
RESET
AL2
Alarm 1 Alarm 2
terminals terminals
6 and 7
5 and 7
Power on
Confirmation
(accepted)
Confirmation
(accepted)
Terminal
Parameter
Function
Analog signal
Contact signal
Front panel key
Legend
● When parameter R.MD is set to 1.
The limit output relay is always energized at power on (point A) (NC terminal : OPEN, NO terminal : CLOSE) and “OUT” lamp is off, except
when PV exceeds SP at power on.
(B)
In Case of High Limit Control
(A)
PV
Hysteresis
SP
SP
Hysteresis
PV
EXCEEDED
Lamp
off
OUT
Lamp
off
lit
off
on
off
on
Output Relay
off
lit
off
lit
lit
off
EXCEEDED
Lamp
off
OUT
Lamp
off
Output Relay
Operation
(RESET key or
external contact input)
Confirmation
(accepted)
on
off
Confirmation
(not accepted)
Operation
(RESET key or
external contact input)
lit
lit
off
off
on
Power on
Confirmation
(accepted)
IM 05D01D21-03E (2)