Download "user manual"
Transcript
GB Before making any electrical connections always make sure the power is disconnected inside the distribution board and that the wire ends are not live. Working from inside the vehicle, shift the air conditioner until the four fixing threads are aligned with the square 395 x 395 mm opening of the hole on the roof. Line the four external sides of the connecting duct with adhesive insulating tape so that it adheres to the folded fixing edge (fig. 8). It is compulsory for the air conditioner to be powered via a separate line protected by a 10 A thermomagnetic switch. To ensure good insulation under all possible conditions electrical wiring must be properly sheathed. 4.3 Positioning the air conditioner Before positioning the air conditioner on the vehicle roof it is necessary to lay a sufficient amount of slow-drying sealant around the rim of the aperture. Bring the air conditioner onto the roof (fig. 7 ref. 2) and, without scraping it, position it over the 395 x 395 mm opening previously lined with sealant. Correct alignment of the air conditioner on the roof will provide a view - from inside the camper - of the 4 threaded fixing seats. The arrow in fig. 7 indicates direction of forward drive. Working from inside the camper, insert the connection duct at the base of the air conditioner; use the four self-tapping screws L.12 mm (supplied). Align the duct with the rectangular hole of the ventilator (fig. 9). The arrow in figure 9 indicates the direction of forward drive. The framed perimeter support seal must be aligned with the edge of the hole (fig 7 ref. 1). 9