2.12 PUMP DUTY Fig. 6 shows the flow-rate available – after allowing for pressure loss through the appliance – for system requirements. When using this graph, apply only the pressure loss of the system. The graph is based on a 20oC temperature differential. 6,8 6,4 6,0 Residual head (x 100 mbar) 5,6 5,2 4,8 4,4 4,0 3,6 3,2 2,8 2,4 2,0 1,6 1,2 0,8 0,4 0,0 Fig. 5 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 Flow rate (l/h) Fig. 6 Key 8 Location A B C D E F G H I J K L M N P Q Below an opening (window, air-brick, etc.) Above an opening (window, air-brick, etc.) To the side of an opening (window, air-brick, etc.) Below gutter, drain-pipe, etc. Below eaves Below balcony, car-port roof, etc. To the side of a soil/drain-pipe, etc. From internal/external corner Above ground, roof, or balcony level From a surface or boundary facing the terminal From a terminal facing a terminal From an opening in the car-port into the building Vertically from a terminal on the same wall Horizontally from a terminal on the same wall From a structure to the side of the vertical terminal From the top of the vertical terminal to the roof flashing R S T V W To the side of a boundary To the side of an opening or window on a pitched roof Below an opening or window on a pitched roof From a vertical terminal to an adjacent opening (window, air-brick, etc.) From a vertical terminal to an adjacent vertical terminal Minimum distance 300 mm 300 mm 300 mm 25 mm 25 mm 25 mm 25 mm (60mm for 80/125 - 5” flue) 25 mm (60mm for 80/125 - 5” flue) 300 mm 600 mm 1200 mm 1200 mm 1500 mm 300 mm 300 mm As determined by the fixed collar of the vertical terminal 300 mm 600 mm 2000 mm (call Vokera technical for advice) 300 mm (only if both terminals are the same hight)