Download - Power Logic
Transcript
Features > High visibility, multilingual, IEC/IEEE configureable display Large, backlit LCD presents multiple simultaneous real-time and time-stamped historical parameters, as well as graphical trends and histograms. > High accuracy standards Meets stringent IEC and ANSI measurement accuracy standards, such as IEC 62053-22 Class 0.2S, ANSI C12.20 0.2 Class 10 and 20. > Digital fault-recording Simultaneously capture voltage and current channels for sub-cycle disturbance transients, as well as multi-cycle sags/swells and outages: 1024 samples/cycle waveform recording, 20/17 μs transient capture (50/60 Hz). > Power quality analysis and compliance monitoring A choice of THD metering, individual current and voltage harmonics readings, waveform capture, EN50160 and flicker (PowerLogic ION7650 only) power quality compliance evaluation and voltage and current disturbance (sag/swell) detection. COMTRADE format waveform records are now available only for meters with the Ethernet port option. > Complete communications: Ethernet (RJ 45 modular or SC fiber) – Serial (RS 485 and/or RS 232) – Modem Gateway functionality simplifies communications architecture and reduces leased line or connection costs. Concurrent, independent ports communicate with protocols such as ION, DNP 3.0, IEC 61850, Modbus RTU, Modbus TCP, Modbus Master. Ethernet port allows the following concurrent connections: 24 Modbus, 8 generic (ION / DNP / Modbus), 4 IEC 61850 dedicated client, 1 FTP and 1 SNMP. Dial-out capability when memory is near full. Data push capability through SMTP (email). > Patented ION technology Provides a modular, flexible architecture that offers extensive user programmability. Uniquely addresses complex monitoring and control applications. Adapts to changing needs, avoiding obsolescence. > Disturbance direction detection Determine the location of a disturbance more quickly and accurately by determining the direction of the disturbance relative to the meter. Analysis results are captured in the event log, along with a time-stamp and confidence level indicating level of certainty. > Alarm setpoint learning Helps simplify alarming configurations by monitoring normal operating parameters and, over time, learning what constitutes a sag, swell, transient or high and low setpoint. Learning can be configured in either ION Setup™ or PowerLogic ION Enterprise software. > Trending and forecasting Forecast values, such as demand to better control demand charges and billing rates. View results via the meter’s web pages. Analyse trends to support proactive maintenance schedules. > Transformer/line loss compensation Automatically measure, compensate and correct for transformer or line losses when meter is physically separated from the point of billing or change of ownership. > Inputs and outputs Digital and analog inputs and outputs for pulse counting, demand metering for other WAGES utilities, equipment status/position monitoring, demand synchronization, triggering conditional energy metering, equipment control or interfacing. ION7550/7650 series power and energy meters • 3