SENTINEL XL HP
FULL HOOD PAPR SYSTEM
TM
THE CHOICE FOR INFECTIOUS DISEASE ENVIRONMENTS
NIOSH approved TC21C-0814
Certified APF 1000
HELPING
TO PROTECT
HEALTHCARE
PROFESSIONALS
IN HOT ZONES
AND HOSPITALS
2
THE SENTINEL XL HP POWERED AIR PURIFYING
RESPIRATOR (PAPR) SYSTEM (MODEL 3000-06)
helps to provide improved protection from pathogens for healthcare workers and first receivers in
the presence of Ebola and other infectious, often-fatal viruses and diseases. It is designed to work
in concert with other CDC- and WHO-recommended personal protection equipment, including fluidresistant gowns, gloves and shoe coverings, in accordance with best practice protocols for donning,
use and doffing.
The Sentinel XL HP PAPR system comes as a complete kit, including one shoulder length
double-bibbed full hood, a flexible breathing hose, blower unit with integrated, rechargeable
NiMH battery, a Smart Battery charger, flow monitor and adjustable Quick-LocTM belt, plus
two P-100 HEPA cartridges and this user literature—all in a durable zippered duffle bag,
ready for immediate deployment.
Read on to learn all of the advantages of the Sentinel XL HP PAPR system.
3
ONE HOOD, MANY BENEFITS.
The Sentinel XL HP head cover is a fully enclosed latex-free hood with an integrated antimicrobial
headband, eliminating the need to buy and stock different size hoods. Its flexible interior profile also
ensures a contoured fit around the chin and face. Forward and peripheral vision is excellent through
the rugged, sealed, clear plastic face shield. A ribbed breathing tube threads securely into the back.
The product is NIOSH approved (TC 21C-0814) and the hood fabric meets ASTM Standards 1670 and 1671.
The belt-mounted blower delivers purified ambient air into the hood at 8.5 scfm with 99.97% filtration
efficiency, creating positive air pressure inside, which helps to support it. The hood also features
two bibs—an inner one that tucks in under the wearer’s fluid-resistant gown through the neck
opening, plus an outer bib that drapes over the chest, shoulders and back, allowing free movement.
It is recommended that the hood be safely disposed of, rather than decontaminated, after
exposure to Ebola or other deadly viruses or diseases.
4
A CHOICE OF THREE
INTEGRAL BATTERY PACKS
A BLOWER DESIGNED
FOR LONG SERVICE LIFE
NiMH
The Sentinel XL dual-chamber blower is encased in a high-impact
The Sentinel XL HP PAPR system comes standard equipped with a rechargeable
nylon shell with a rugged inner polycarbonate chamber. It also
nickel metal hydride battery (NiMH) and Smart Battery charger. The blower runs
features rounded surfaces to resist snagging, plus a robust motor
up to 8 hours on a single charge and emits an audible and visual warning if battery
design for quieter operation and longer life. The blower delivers
power gets low. The battery recharges in 5 hours.
8.5 scfm of filtered ambient air—33% higher flow than required by
NIOSH. Air is fed through two NIOSH-approved screw-in type HEPA
Li-MnO2
cartridge filters. The blower can also be converted for use in
A lithium-manganese dioxide battery is also available. It offers up to 10 hours
chemical, biological, radiation or nuclear applications when
of operation but is not rechargeable. Its advantage lies in its 10-year shelf life,
equipped with three CBRN-type filters. The blower’s integral
so it may be left in storage until needed—ready for any emergency—without
low-battery voltage alarm—both audible and visual—works with
worries about power draining or recharging.
all three types of batteries, NiMH, Li-MnO2 and alkaline.
ALKALINE
For the ultimate in increased readiness, choose ILC’s innovative alkaline battery
pack accessory option. Ideal as an NiMH battery backup, or for remote locations,
or when available generator power is tapped out, this unique solution comes with a
5-pack of DuraCell® D-cell batteries, its own adapter and backing plate, and runs the
blower for up to 10 hours. When the D-cells run low, just replace them with fresh
batteries. No waiting, no recharging. And only ILC offers this option.
All three Sentinel battery packs snap into place in the blower housing to form an
integrated, self-contained system. This exclusive ILC Dover design offers clear
advantages over competitive PAPR systems that require the battery pack to be
connected to the blower with an external cord that adds weight and complexity,
and poses a risk of snagging on medical equipment, patient beds or door handles.
® DuraCell is a registered trademark of The Gillette Company.
5
TWO EASY-TO-INSTALL
P-100 FILTERS
As easy to screw in as a light bulb, ILC’s high-efficiency particulate air
(HEPA) filters remove 99.97% of 0.3 µm particles from air passing through
them. ILC filters are NIOSH-approved and designed to pass a 4-hour silica
dust test with no drop in required airflow. They are rugged, lightweight and
A SIMPLER FLOW SENSOR
There are no tips, bullet ends or misaligned threading to worry
about. The Sentinel XL flow meter twists securely into place,
then turn on the blower to check airflow. The meter tube is clear
and simple to read. Positive air pressure keeps the sensor indicator
floating up in the safety zone.
will not leak or be difficult to clean like some filtration systems. The safety
plug beneath the chamber can be removed to add a third filter if the blower
is converted for use in CBRN-specific applications.
ONE FLEXIBLE BREATHING TUBE
QUICK LOC BELT
TM
The Sentinel XL blower and battery pack click into place, locking
securely to our proprietary belt design. Unlike fabric belts that can
be grabby, our polymeric belt is lightweight, smooth, easy to grasp
and adjusts in two directions with a simple pull on the straps.
The Sentinel XL breathing tube is a clear, ribbed design that reliably
links the hood and blower system. Its durable design resists nicks
and cuts. Epoxy at both ends of the tube ensures a strong seal and
sure-handed threading, top and bottom. The tube is easy to use
and replace if exposed to Ebola or other lethal viruses or diseases.
Replacement tubes are sold in packs of five.
6
SENTINEL XL™ HP SYSTEM TRAINING
TO HELP BETTER PROTECT
YOUR PERSONNEL
While many hospitals and healthcare systems offer CDC- and WHO-recommended training
on how to properly and safely put on, operate and remove PAPRs, ILC can also send a highly
skilled instructor to your location for Sentinel XL HP-specific training sessions. This can
help to ensure that your physicians and nurses, EMTs, first receivers or other healthcare
personnel are competent and confident in all procedures and safeguards.
Please review the guidelines as released by the CDC and WHO, then visit their respective
websites for the most current data or instructions. Basic Sentinel XL HP system training
guidelines may be found in the video section of our website, www.ILCDover.com
REPLACEMENTS AND SPARES
The Sentinel XL HP PAPR system comes fully equipped to protect one individual.
Additional hoods, extra batteries, breathing tubes and HEPA filters may be ordered
separately. Hoods in particular should be properly discarded after one-time use in
the presence of Ebola or other deadly diseases. For more information about the availability
of replacement or spare components, please contact ILC Dover at 302.325.3911, x-506 or
800.631.9567 or send an email to [email protected]
7
SENTINEL XL™ HP PAPR
FEATURES/COMPONENTS
KEY FEATURES:
• Shoulder-length, double-bibbed hood provides full coverage and
integrates easily with gowns, suits and other PPE
• Single-size hood eliminates the need to purchase and stock multiple sizes
• No fit testing required
• Audible/visible low-voltage alarm provides peace of mind
• Three battery options, including a unique alkaline battery adapter,
provide flexibility and readiness in a broad range of use scenarios
• Threaded interface filters and breathing-tube connections are
reliable and easy to use
Lightweight and durable, loose-fitting PAPR designed
to protect against airborne infectious diseases.
SYSTEM COMPONENTS:
•
•
•
•
•
•
•
•
•
•
•
Blower
Choice of full hood (shown) or white or premium head cover
2 HEPA filters and plug
Rechargeable NiMH battery pack (standard)
Fast battery charger
Flow meter
Quick-Loc™ belt
33” long HP breathing hose
Non-rechargeable LiMnO2 battery pack (optional)
Alkaline D-cell battery adapter (optional)
Backpack (optional)
8
SENTINEL XL™ HP PAPR
EASY CONVERSION
EASILY CONVERTIBLE TO CBRN SYSTEM
System can be converted for CBRN applications simply by changing hood, hose and filter cartridges.
CBRN CAP 2 CONVERSION KIT (5-5000-05)
Unique lay-flat butyl hood assembly
3 CBRN filter cartridges
CBRN Cap 2 User’s Manual
ADD NIOSH-APPROVED BACKPACK (OPTIONAL)
Designed to hold blower/battery, hood, charger, hose and up to three filter cartridges.
Blower can be charged while in backpack
Material: Polyester and nylon
9
One Moonwalker Road
Frederica, DE USA 19446-2080
302.335.3911
800.631.9567
[email protected]
www.ilcdover.com
ABOUT ILC DOVER
Founded in 1947, ILC Dover specializes in products and technologies that provide unparalleled protection for people and equipment
in hostile environments. We have been the sole designer and manufacturer of NASA space suits since manned Apollo missions began
in 1967. And we’re “creating what’s next” for future missions to Mars. We are also leveraging these competencies in materials, soft
goods and film-based solutions to protect humans against infectious or deadly diseases and chemical, biological, radiological and
nuclear contamination. In the pharmaceutical industry, we provide powder transfer packaging, liners and containment systems,
FDA-compliant films, equipment enclosures, and PAPRs to protect workers against active pharmacological agents.
Additionally, we are world leaders in engineered inflatable and lighter-than-air products for use by the military and homeland
security, plus products for flood, smoke and fire protection and infrastructure security. ILC Dover’s design engineers can also
partner with you to custom-create a product or technology for your precise application or need. Let us ”create what’s next” for you.
Learn more about us at www.ilcdover.com
MKT-0037 Rev D