Download Sentinel XL Full Hood Brochure - multi-page
Transcript
SENTINEL XL HP FULL HOOD PAPR SYSTEM TM THE CHOICE FOR INFECTIOUS DISEASE ENVIRONMENTS NIOSH approved TC21C-0814 Certified APF 1000 HELPING TO PROTECT HEALTHCARE PROFESSIONALS IN HOT ZONES AND HOSPITALS 2 THE SENTINEL XL HP POWERED AIR PURIFYING RESPIRATOR (PAPR) SYSTEM (MODEL 3000-06) helps to provide improved protection from pathogens for healthcare workers and first receivers in the presence of Ebola and other infectious, often-fatal viruses and diseases. It is designed to work in concert with other CDC- and WHO-recommended personal protection equipment, including fluidresistant gowns, gloves and shoe coverings, in accordance with best practice protocols for donning, use and doffing. The Sentinel XL HP PAPR system comes as a complete kit, including one shoulder length double-bibbed full hood, a flexible breathing hose, blower unit with integrated, rechargeable NiMH battery, a Smart Battery charger, flow monitor and adjustable Quick-LocTM belt, plus two P-100 HEPA cartridges and this user literature—all in a durable zippered duffle bag, ready for immediate deployment. Read on to learn all of the advantages of the Sentinel XL HP PAPR system. 3 ONE HOOD, MANY BENEFITS. The Sentinel XL HP head cover is a fully enclosed latex-free hood with an integrated antimicrobial headband, eliminating the need to buy and stock different size hoods. Its flexible interior profile also ensures a contoured fit around the chin and face. Forward and peripheral vision is excellent through the rugged, sealed, clear plastic face shield. A ribbed breathing tube threads securely into the back. The product is NIOSH approved (TC 21C-0814) and the hood fabric meets ASTM Standards 1670 and 1671. The belt-mounted blower delivers purified ambient air into the hood at 8.5 scfm with 99.97% filtration efficiency, creating positive air pressure inside, which helps to support it. The hood also features two bibs—an inner one that tucks in under the wearer’s fluid-resistant gown through the neck opening, plus an outer bib that drapes over the chest, shoulders and back, allowing free movement. It is recommended that the hood be safely disposed of, rather than decontaminated, after exposure to Ebola or other deadly viruses or diseases. 4 A CHOICE OF THREE INTEGRAL BATTERY PACKS A BLOWER DESIGNED FOR LONG SERVICE LIFE NiMH The Sentinel XL dual-chamber blower is encased in a high-impact The Sentinel XL HP PAPR system comes standard equipped with a rechargeable nylon shell with a rugged inner polycarbonate chamber. It also nickel metal hydride battery (NiMH) and Smart Battery charger. The blower runs features rounded surfaces to resist snagging, plus a robust motor up to 8 hours on a single charge and emits an audible and visual warning if battery design for quieter operation and longer life. The blower delivers power gets low. The battery recharges in 5 hours. 8.5 scfm of filtered ambient air—33% higher flow than required by NIOSH. Air is fed through two NIOSH-approved screw-in type HEPA Li-MnO2 cartridge filters. The blower can also be converted for use in A lithium-manganese dioxide battery is also available. It offers up to 10 hours chemical, biological, radiation or nuclear applications when of operation but is not rechargeable. Its advantage lies in its 10-year shelf life, equipped with three CBRN-type filters. The blower’s integral so it may be left in storage until needed—ready for any emergency—without low-battery voltage alarm—both audible and visual—works with worries about power draining or recharging. all three types of batteries, NiMH, Li-MnO2 and alkaline. ALKALINE For the ultimate in increased readiness, choose ILC’s innovative alkaline battery pack accessory option. Ideal as an NiMH battery backup, or for remote locations, or when available generator power is tapped out, this unique solution comes with a 5-pack of DuraCell® D-cell batteries, its own adapter and backing plate, and runs the blower for up to 10 hours. When the D-cells run low, just replace them with fresh batteries. No waiting, no recharging. And only ILC offers this option. All three Sentinel battery packs snap into place in the blower housing to form an integrated, self-contained system. This exclusive ILC Dover design offers clear advantages over competitive PAPR systems that require the battery pack to be connected to the blower with an external cord that adds weight and complexity, and poses a risk of snagging on medical equipment, patient beds or door handles. ® DuraCell is a registered trademark of The Gillette Company. 5 TWO EASY-TO-INSTALL P-100 FILTERS As easy to screw in as a light bulb, ILC’s high-efficiency particulate air (HEPA) filters remove 99.97% of 0.3 µm particles from air passing through them. ILC filters are NIOSH-approved and designed to pass a 4-hour silica dust test with no drop in required airflow. They are rugged, lightweight and A SIMPLER FLOW SENSOR There are no tips, bullet ends or misaligned threading to worry about. The Sentinel XL flow meter twists securely into place, then turn on the blower to check airflow. The meter tube is clear and simple to read. Positive air pressure keeps the sensor indicator floating up in the safety zone. will not leak or be difficult to clean like some filtration systems. The safety plug beneath the chamber can be removed to add a third filter if the blower is converted for use in CBRN-specific applications. ONE FLEXIBLE BREATHING TUBE QUICK LOC BELT TM The Sentinel XL blower and battery pack click into place, locking securely to our proprietary belt design. Unlike fabric belts that can be grabby, our polymeric belt is lightweight, smooth, easy to grasp and adjusts in two directions with a simple pull on the straps. The Sentinel XL breathing tube is a clear, ribbed design that reliably links the hood and blower system. Its durable design resists nicks and cuts. Epoxy at both ends of the tube ensures a strong seal and sure-handed threading, top and bottom. The tube is easy to use and replace if exposed to Ebola or other lethal viruses or diseases. Replacement tubes are sold in packs of five. 6 SENTINEL XL™ HP SYSTEM TRAINING TO HELP BETTER PROTECT YOUR PERSONNEL While many hospitals and healthcare systems offer CDC- and WHO-recommended training on how to properly and safely put on, operate and remove PAPRs, ILC can also send a highly skilled instructor to your location for Sentinel XL HP-specific training sessions. This can help to ensure that your physicians and nurses, EMTs, first receivers or other healthcare personnel are competent and confident in all procedures and safeguards. Please review the guidelines as released by the CDC and WHO, then visit their respective websites for the most current data or instructions. Basic Sentinel XL HP system training guidelines may be found in the video section of our website, www.ILCDover.com REPLACEMENTS AND SPARES The Sentinel XL HP PAPR system comes fully equipped to protect one individual. Additional hoods, extra batteries, breathing tubes and HEPA filters may be ordered separately. Hoods in particular should be properly discarded after one-time use in the presence of Ebola or other deadly diseases. For more information about the availability of replacement or spare components, please contact ILC Dover at 302.325.3911, x-506 or 800.631.9567 or send an email to [email protected] 7 SENTINEL XL™ HP PAPR FEATURES/COMPONENTS KEY FEATURES: • Shoulder-length, double-bibbed hood provides full coverage and integrates easily with gowns, suits and other PPE • Single-size hood eliminates the need to purchase and stock multiple sizes • No fit testing required • Audible/visible low-voltage alarm provides peace of mind • Three battery options, including a unique alkaline battery adapter, provide flexibility and readiness in a broad range of use scenarios • Threaded interface filters and breathing-tube connections are reliable and easy to use Lightweight and durable, loose-fitting PAPR designed to protect against airborne infectious diseases. SYSTEM COMPONENTS: • • • • • • • • • • • Blower Choice of full hood (shown) or white or premium head cover 2 HEPA filters and plug Rechargeable NiMH battery pack (standard) Fast battery charger Flow meter Quick-Loc™ belt 33” long HP breathing hose Non-rechargeable LiMnO2 battery pack (optional) Alkaline D-cell battery adapter (optional) Backpack (optional) 8 SENTINEL XL™ HP PAPR EASY CONVERSION EASILY CONVERTIBLE TO CBRN SYSTEM System can be converted for CBRN applications simply by changing hood, hose and filter cartridges. CBRN CAP 2 CONVERSION KIT (5-5000-05) Unique lay-flat butyl hood assembly 3 CBRN filter cartridges CBRN Cap 2 User’s Manual ADD NIOSH-APPROVED BACKPACK (OPTIONAL) Designed to hold blower/battery, hood, charger, hose and up to three filter cartridges. Blower can be charged while in backpack Material: Polyester and nylon 9 One Moonwalker Road Frederica, DE USA 19446-2080 302.335.3911 800.631.9567 [email protected] www.ilcdover.com ABOUT ILC DOVER Founded in 1947, ILC Dover specializes in products and technologies that provide unparalleled protection for people and equipment in hostile environments. We have been the sole designer and manufacturer of NASA space suits since manned Apollo missions began in 1967. And we’re “creating what’s next” for future missions to Mars. We are also leveraging these competencies in materials, soft goods and film-based solutions to protect humans against infectious or deadly diseases and chemical, biological, radiological and nuclear contamination. In the pharmaceutical industry, we provide powder transfer packaging, liners and containment systems, FDA-compliant films, equipment enclosures, and PAPRs to protect workers against active pharmacological agents. Additionally, we are world leaders in engineered inflatable and lighter-than-air products for use by the military and homeland security, plus products for flood, smoke and fire protection and infrastructure security. ILC Dover’s design engineers can also partner with you to custom-create a product or technology for your precise application or need. Let us ”create what’s next” for you. Learn more about us at www.ilcdover.com MKT-0037 Rev D