Download Manual - Hearth & Home Technologies
Transcript
AVFL Vent Free Fireplace MAINTENANCE AND CLEANING FLAME APPEARANCE Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation. Thermocouple for Natural Gas CHECK THE PILOT FLAME The pilot flame must always be present when the heater is in operation. It should just touch the top of the thermocouple tip for natural gas. Refer to Figure 27 for correct pilot flame. If the pilot flame does not touch the thermocouple, then the main burner cannot function reliably. Refer to Figure 28 for incorrect shape of pilot flame. Thermocouple for LP FP2272 Figure 27 – Correct Pilot Flame Appearance CHECK BURNER FLAME APPEARANCE In normal operation, at full rate after 15 minutes, the flames should appear as shown in Figure 29. Thermocouple for Natural Gas If logs are installed, the flames should be yellow and should not impinge on the logs. Thermocouple for LP FP2273 Figure 28 – Incorrect Pilot Flame Appearance LG1181 Figure 29 – Burner Flame Appearance (Shown with fireglass only) 28 20305467