G8 DUAL SETTING
G8.1 DUAL SETTING
Screen
Description
Range
Default Value
Function
Adjust
Applications
1 DUALSETING=NO
Dual Setting.
Yes/No
No
Enable/Disable a second adjustment for G4 Acceleration, G5 Deceleration and for the
overload curve (G3.3 Overload Curve).
When a second parameter is required set select Dual Setting to Yes. This second
adjustment is activated by one of digital inputs.
Mills, crushers and any application that at a certain operation stage requires a
harder/softer parameter set.
G8.2 TORQUE PULSE 2
Screen
Description
Range
Unit
Default Value
Function
Adjust
2 PLS TORQ2=50%
Dual setting Torque Pulse
50 a 100%
% of rated Motor torque
50%
Choose the torque pulse level applied to the motor for the time specified at G8.3
Set this value in conjunction with G8.3 to initiate a first acceleration of the motor.
G8.3 PULSE TORQUE TIME 2
Screen
Description
Range
Units
Default Value
Function
Adjust
3 PLS TQ T2=OFF
Dual setting Pulse Time.
OFF, 0 to 0.9s
Seconds
OFF
Refer to G4.3.
Refer to G4.3
G8.4 INITIAL TORQUE 2
Screen
Description
Range
Default Value
Function
Adjust
4 INIT TRQ2 =30%
Dual setting Initial Torque.
30 to 99%
30%
Refer to G4.4
Refer to G4.4
G8.5 INITIAL TORQUE TIME 2
Screen
Description
Range
Units
Default Value
Function
Adjust
5 INIT TQ T2=1s
Dual setting Initial Torque Time .
0 a 10
seconds
1
Refer to G8.4
Refer to G4.5
G8.6 ACCELERATION TIME 2
Screen
Description
Range
Units
Default Value
Function
Adjust
62
6 ACC TIME2=12s
Dual Setting Acceleration Time.
0 to 180
Seconds
12
Refer to G4.6
Refer to G4.6
POWER ELECTRONICS Technical Manual V5