Download Bio Integrator User Guide - Bio
Transcript
Bio Integrator Plus User Guide animate only as fast as the individual's heart is beating. Heart Rate 3D Spectrum displays: These displays show 25 individual frequency bins, from .02 Hz to .5 Hz. They are broken up into four color bands. A spectral display shows frequency distribution in relation to time and a particular variable. Each color gradient represents a frequency bin that is .02 Hz wide. The entire display is updated after each heartbeat. The heart rate 3D spectrum display will animate only as fast as the individual's heart is beating. You can control how much space is between each "slice" by going to the F4 menu and looking under 3D Spectrum Spacing, Heart Rate. Note: It takes 40 seconds of valid PPG data to collect enough heart beats to create meaningful heart rate spectrum data/displays. We recommend waiting at least this much time before starting to record your session. Regular and Superimposed Oscilloscope Graphs: The Bio Integrator includes a digital oscilloscope for looking at raw EEG waveforms. We also include a superimposed oscilloscopic display that shows left and right traces, but instead of one being above the other, they are superimposed. This allows the clinician to study interesting variations in the raw wave forms between one channel and another. Spectral Histograms: Spectral histograms displays are a useful way to see EEG data because each frequency bin is clearly represented by a moving bar. Real-time EEG data is represented by fluid, smoothly animated and aesthetically engaging spectral histogram displays. These displays represent four separate measures: power, percent power, amplitude, and synchrony. A spectral display shows frequency distribution in relation to time and a particular variable. Depending on the display, the frequency shown is either from 3 Hz to 32 Hz or from 0 Hz to 42 Hz.. Each color gradient represents a frequency bin that is .8 Hz wide. The entire display is updated 20 times per second (every 50ms), as is the EEG analysis, allowing for the observation of both gross and subtle brainwave shifts. When the program is used with two channels of EEG, it is possible to compare two separate sites such as right and left brain activity and observe interesting and exciting differences within individual clients and across clients. EEG Spectral displays: Spectral displays are one of the most exciting features of the Bio Integrator Plus: For the first time, clients and clinicians may watch and train with real-time EEG data represented by fluid, smoothly animated and aesthetically engaging spectral displays. These displays represent four separate measures: power, percent power, amplitude, and synchrony. A spectral display shows frequency distribution in relation to time and a particular variable. Depending on the display, the frequency shown is either from 3 Hz to 32 Hz or from 0 Hz to 42 Hz. Each color gradient represents a frequency bin that is .8 Hz wide. The entire display is updated 20 times per second (every 50ms), as is the EEG analysis, allowing for the observation of both gross and subtle brainwave shifts. When the program is used with two channels of EEG, it is possible to compare two separate sites such as right and left brain activity and observe interesting and exciting Page 31