Download Electrical/Battery/Mechanical Protocols - Hardware
Transcript
Product Spec # : DG-EA017(US) Relocatable Power Tap Version : 7 Date: August 10, 2011 Page 1 of 3 Test Items Document Review 1. Labeling – Packaging or product 2. Country of origin 3. Safety listing mark 4. General and Cautionary Markings 5. User Manual / Important Safety Instructions / Assembly Instructions Construction Check 6. Packing 7. Parts Inventory 8. Workmanship external Test Method Test Requirements Uniform Labelling Regulation Distributor’s name & Address (City, State & Zip) shall be shown on the packaging Product Identification NAFTA & If imported, country of origin marking shall be provided and clearly FTCA / Sect. 5 indicated to the ultimate purchaser of a product where it is made. Document Check Shall have valid UL or ETL listing or equivalent. Verify listing by NRTL product directory with the sample's listing number and model number. UL 1363, Cls 38 Shall be permanently and clearly marked on the outside of the enclosure with: a) Manufactures name, trade name, trademark or other descriptive marking which identifies the organization responsible for the product b) Catalogue number or equivalent c) Rating in voltage and amperes d) Date of manufacture UL 1363, 2ed. Cls. 38 Instructions and warnings shall be provided to identifying reasonable, foreseeable uses or misuses of the product. All accessories shall be described in the user’s manual and provided with instructions for proper use. DOLLAR GENERAL CONFIDENTIAL Visual Visual Visual Check 9. Workmanship internal Visual Check 10. Internal Wires Visual Check 11. Mechanical Assembly Visual Check 12. Polarization Visual Check 13. Cord Type and Length UL 1363 Electrical Safety 14. Component Check 15. Dielectric VoltageWithstand Test 16. Accessibility of Live Parts Strain Relief 17. No hazard when removing the packing Shall meet label claims. Shall have no major defects such as: - Cracks or breakage on provided accessories - Serious scratches on the external surface - Peeling of rating or caution / warning label Solder connections shall be secured Components shall be reliably mounted on PCB or other proper fixing. Wireways shall be smooth and entirely free from sharp edges, burrs, fins, moving parts, and the like that may cause abrasion of insulation on conductors. All soldering joints shall be mechanically secured before soldered. All mechanical parts shall be securely fixed and prevented from turning. Switch, fuse and other protective device shall be connected at ungrounded conductors. The polarization of conductors at plug and receptacles shall be matched A cord-connected appliance shall be provided with an appropriate type and length of flexible cord per section Visual If listing safety report provided, report any difference of component used in the sample and the listing report. Exclude plastic material, insulation material or other without marking components. UL 1363, 2ed. Cls. 23 The insulation and spacings shall withstand the dielectric voltage withstand test without breakdown for a period of 1 min when a test voltage of 1250Vac is applied between: a) Live parts and accessible metal parts b) Live parts of different polarity. Visual Check The electrical parts shall be located or enclosed so that persons are protected against inadvertent contact with uninsulated live parts. UL 1363, Cls 30.2 The supply cord shall withstand for 1 min without displacement a direct pull of 35lbs. Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services. Copying is prohibited without permission of Intertek in written document. This specification does not purport to include all the necessary provisions nor address all of the safety concerns, if any, associated with its use. Compliance with this specification does not of itself confer immunity from legal obligations.