Product Spec # : DG-EA017(US)
Relocatable Power Tap
Version : 7
Date: August 10, 2011
Page 1 of 3
Test Items
Document Review
1.
Labeling – Packaging
or product
2.
Country of origin
3.
Safety listing mark
4.
General and
Cautionary Markings
5.
User Manual /
Important Safety
Instructions /
Assembly Instructions
Construction Check
6.
Packing
7.
Parts Inventory
8.
Workmanship external
Test Method
Test Requirements
Uniform Labelling
Regulation
Distributor’s name & Address (City, State & Zip) shall be shown on
the packaging
Product Identification
NAFTA &
If imported, country of origin marking shall be provided and clearly
FTCA / Sect. 5
indicated to the ultimate purchaser of a product where it is made.
Document Check
Shall have valid UL or ETL listing or equivalent. Verify listing by
NRTL product directory with the sample's listing number and model
number.
UL 1363, Cls 38
Shall be permanently and clearly marked on the outside of the
enclosure with:
a) Manufactures name, trade name, trademark or other
descriptive marking which identifies the organization
responsible for the product
b) Catalogue number or equivalent
c) Rating in voltage and amperes
d) Date of manufacture
UL 1363, 2ed. Cls. 38 Instructions and warnings shall be provided to identifying
reasonable, foreseeable uses or misuses of the product.
All accessories shall be described in the user’s manual and provided
with instructions for proper use.
DOLLAR
GENERAL
CONFIDENTIAL
Visual
Visual
Visual Check
9.
Workmanship internal
Visual Check
10.
Internal Wires
Visual Check
11.
Mechanical Assembly
Visual Check
12.
Polarization
Visual Check
13.
Cord Type and Length
UL 1363
Electrical Safety
14. Component Check
15.
Dielectric VoltageWithstand Test
16.
Accessibility of Live
Parts
Strain Relief
17.
No hazard when removing the packing
Shall meet label claims.
Shall have no major defects such as:
- Cracks or breakage on provided accessories
- Serious scratches on the external surface
- Peeling of rating or caution / warning label
Solder connections shall be secured
Components shall be reliably mounted on PCB or other proper
fixing.
Wireways shall be smooth and entirely free from sharp edges, burrs,
fins, moving parts, and the like that may cause abrasion of insulation
on conductors. All soldering joints shall be mechanically secured
before soldered.
All mechanical parts shall be securely fixed and prevented from
turning.
Switch, fuse and other protective device shall be connected at
ungrounded conductors.
The polarization of conductors at plug and receptacles shall be
matched
A cord-connected appliance shall be provided with an appropriate
type and length of flexible cord per section
Visual
If listing safety report provided, report any difference of component
used in the sample and the listing report. Exclude plastic material,
insulation material or other without marking components.
UL 1363, 2ed. Cls. 23 The insulation and spacings shall withstand the dielectric voltage
withstand test without breakdown for a period of 1 min when a test
voltage of 1250Vac is applied between:
a) Live parts and accessible metal parts
b) Live parts of different polarity.
Visual Check
The electrical parts shall be located or enclosed so that persons are
protected against inadvertent contact with uninsulated live parts.
UL 1363, Cls 30.2
The supply cord shall withstand for 1 min without displacement a
direct pull of 35lbs.