OWON HDS-N Series Handheld DSO & DMM 8-Advanced Function of Oscilloscope division, trigger level or time scale for CH1 or CH2. To back to Autoscale, Press AUTOSET. 6. The oscilloscope is always on main time base. 7. The oscilloscope is turned into Peak Detection mode if it is in Average mode. 8. When video triggering, the horizontal time scale is 50us. If one channel is showing edge signal, the other channel is showing video one, the time scale refers to 50us as video one as standard. 8.13 Record Waveform record: The function provides you to set the time interval between the frames and record the waveform up to 1000 numbers and get the better analysis effect more than before through Playback and Save functions. Four record modes: Record, Play back, Storage, OFF. Record:Record the waveforms up till the set number of frames at specified time intervals. Record menu list: Menu Setting Instruction Record Select record mode. Play back Select play back mode. Mode Storage OFF End frame 1-1000 Select storage mode. Turn off all recorder functions. Set number of record frames. Play Press to start recording. Stop Press to stop recording. Operate Interval 1ms~1000s --> 1/2 Set time interval between record frames. To next menu ON The waveforms are in the state of refreshing when recording. OFF The waveforms stop refreshing when recording. Refreshed Increase The value increases from that of end frame to time interval Decrease The value decreases from that of end frame to time interval Direction --> 1/2 Back to previous menu. Note: Both the waveforms are recorded at record mode. If one channel is off when recording, the channel data is not available at Playback mode. 63