Download TECHNICAL BULLETIN
Transcript
TECHNICAL BULLETIN [Issue No.] T40-0007 [Title] Corrections in the QnPRHCPU User's Manual (Redundant System) [Page] 1/4 [Date of Issue] Dec., '06 [Relevant Models] Q12PRHCPU, Q25PRHCPU Thank you for your continued support of Mitsubishi programmable logic controllers, MELSEC-Q series. This bulletin provides information on corrections due to clerical errors in the program examples of the QnPRHCPU User's Manual (Redundant System) (SH-080486ENG) of “version F (printed in June, 2006)”. The contents of this technical bulletin are included in the "version G (printed in December, 2006)". 1. Correction (1) (2) (3) (4) (5) Section 7.1 (1) (b) [Diagram 7.2 Example of REMFR instruction programming] Section 7.3 (1) [Diagram 7.13 Program That Turns on the "USER" LED after System Switching] Section 8.2 (2) (c) [Diagram 8.10 Sample Program for Clearing Standby System CPU Module Error] Appendix 4.5 (1) (a) 2) [Diagram App.7 A sample program of CHANGE] Appendix 5 (2) [Diagram App.20 A program example] 2. Correction details (1) Section 7.1 (1) (b) [Diagram 7.2 Example of REMFR instruction programming] The setting condition for the host data link status has been corrected in the example of a program for reading intelligent function module data of the remote I/O station using the REMFR instruction as shown below. (Error) (Correction) HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN TECHNICAL BULLETIN [Issue No.] T40-0007 [Title] Corrections in the QnPRHCPU User's Manual (Redundant System) [Page] 2/4 [Date of Issue] Dec., '06 [Relevant Models] Q12PRHCPU, Q25PRHCPU (2) Section 7.3 (1) [Diagram 7.13 Program That Turns on the "USER" LED after System Switching] The SM1518 contact and the storage destination device of the DMOV instruction have been corrected in the example of a program for turning ON “USER” LED on the CPU module in the new control system after switching as shown below. (Error) M100 16 END (Correction) F2047 F2047 (3) Section 8.2 (2) (c) [Diagram 8.10 Sample Program for Clearing Standby System CPU Module Error] The SM1510 contact has been corrected in the example of a program for clearing errors of the CPU module in standby system as shown below. (Error) (Correction) HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN TECHNICAL BULLETIN [Issue No.] T40-0007 [Title] Corrections in the QnPRHCPU User's Manual (Redundant System) [Page] 3/4 [Date of Issue] Dec., '06 [Relevant Models] Q12PRHCPU, Q25PRHCPU (4) Appendix 4.5 (1) (a) 2) [Diagram App.7 A sample program of CHANGE] The head device number in the remote register has been corrected in the example of a program when using CC-Link as shown below. (Error) (Correction) K4X1000 HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN TECHNICAL BULLETIN [Issue No.] T40-0007 [Title] Corrections in the QnPRHCPU User's Manual (Redundant System) [Page] 4/4 [Date of Issue] Dec., '06 [Relevant Models] Q12PRHCPU, Q25PRHCPU (5) Appendix 5 (2) [Diagram App.20 A program example] 1) Operation of the program before correction When 32768 seconds (around 9. 1 hours) elapses after the CPU module became RUN status, SD412 value will be –32768. In the following program (before correction), since the processing is repeated in the relevant program until the SD412 value will be 10 or more again (around 9. 1 hours), other sequence operations cannot be performed. Note when this occurs, the CPU module will not be STOP status even the RUN/STOP switch is set from RUN to STOP. 2) Corrections The method for starting with the previous control system has been corrected in the example of a program when mounting a network module to the base unit as shown below. (Before correction) Permits system switching after System B's network unit has started properly. Executes the system switching instruction after System B's network unit has started properly. Jumps to the END instruction during system switching command execution. Enables communication with Program which GX Developers or others. waits 10 seconds Resets the watchdog timer. while System B's network module Jumps to P0 until SD412=10 is starting (10 seconds). (After correction) Makes the subroutine program (P100) execute when the previous control system is the system B. Jumps the processing to the END instruction by executing the system switching instruction. User program Ends the main routine program. Stores the value of SD412 at subroutine program execution to D400. Enables system switching when the network module in the B system starts normally. Executes the system switching instruction when the network module in the B system starts normally. Jumps the processing to P101 with the system switching instruction. Enables communications with GX Developer or others. Program which Calculates the subroutine program waits 10 seconds executing time. for the network Resets the watchdog timer. module startup in the system B. Continues the jumps to P100 until the SD401 value becomes 10 (10 seconds). Ends the subroutine program. HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN