Download Circuit-Breakers/Non-Automatic Circuit
Transcript
Circuit-Breakers up to 3200 A, Discontinued Series Accessories/spare parts ■ Selection and ordering data For fixed-mounted and withdrawable circuit-breakers Current transformers for neutral conductor overload protection and ground-fault protection Only one of the two measuring methods is permissible in conjunction with the electronic trip unit. The overload protection for the neutral conductor takes effect when the current transformer is fitted in the neutral conductor. The ground-fault current is calculated by means of summation current formation of the phases and the neutral conductor. In the case of electronic trip unit version P, overload protection in the neutral conductor is achievable with 4 transformers (in L1, L2, L3, N) and ground-fault protection by summation current formation, or with a 5th transformer in the neutral point direct measurement of the ground-fault current and overload protection in the neutral conductor (without summation current formation). Type of detection (see Page 5/88) Designation Electronic trip unit version Primary rated current of the transformer 5th and 9th positions of Order No. for circuit-breaker [email protected][email protected].... Required DT order quantity per circuitbreaker For 1 set or 1 unit PS* Order No. Weight per PU approx. kg Vectorial summation with current transformer in the neutral conductor Current transformers for 3-pole circuit-breakers C, D, E, H, J 5 For 4-pole circuit-breakers N, P the fourth current transformer is fitted internally. If electronic trip unit version E is chosen for 4-pole circuit-breakers, the fourth current transformer must be mounted externally and be selected from the table opposite. 315 A 400 A 500 A 630 A 0 0 0 0 A B C D 1 unit C C C C 3WX36 43–1CA00 3WX36 43–1CB00 3WX36 43–1CC00 3WX36 43–1CD00 1 unit 1 unit 1 unit 1 unit on req. on req. on req. on req. 315 A 1000 A 1250 A 1600 A 1 2 3 4 E F G H 1 unit C C C C 3WX36 43–1CE00 3WX36 43–1CF00 3WX36 43–1CG00 3WX36 43–1CH00 1 unit 1 unit 1 unit 1 unit on req. on req. on req. on req. 1250 A 1600 A 2000 A 2500 A 3200 A 5 5 5 6 7 G H J K M 1 unit C C C C C 3WX36 43–1FG00 3WX36 43–1FH00 3WX36 43–1FJ00 3WX36 43–1FK00 3WX36 43–1FM00 1 unit 1 unit 1 unit 1 unit 1 unit on req. on req. on req. on req. on req. 630 A 800 A 1000 A 1250 A 1600 A 0 1 2 3 4 D E F G H 1 unit C 3WX36 43–2BA00 1 unit 3.000 2000 A 2500 A 3200 A 5 6 7 J K M 1 unit C 3WX36 43–2FA00 1 unit 3.000 315 A 400 A 500 A 630 A 0 0 0 0 A B C D 1 unit C C C C 3WX36 43–1CA00 3WX36 43–1CB00 3WX36 43–1CC00 3WX36 43–1CD00 1 unit 1 unit 1 unit 1 unit on req. on req. on req. on req. 800 A 1000 A 1250 A 1600 A 1 2 3 4 E F G H 1 unit C C C C 3WX36 43–1CE00 3WX36 43–1CF00 3WX36 43–1CG00 3WX36 43–1CH00 1 unit 1 unit 1 unit 1 unit on req. on req. on req. on req. 1250 A 1600 A 2000 A 2500 A 3200 A 5 5 5 6 7 G H J K M 1 unit C C C C C 3WX36 43–1FG00 3WX36 43–1FH00 3WX36 43–1FJ00 3WX36 43–1FK00 3WX36 43–1FM00 1 unit 1 unit 1 unit 1 unit 1 unit on req. on req. on req. on req. on req. Direct detection of ground-fault current by means of a current transformer in the grounded neutral point of the transformer. Current transformers for 3- and 4-pole circuit-breakers td test C, E, P, J (3-pole); E, P, J (4-pole) Designation Rated control supply voltage/ rated operational voltage AC 50/60 Hz DC Storage device for shunt release Rated control supply voltage must match the rated control supply voltage of the shunt release 110–127 V 220–240 V 110–115 V 220–250 V Function tester for electronic trip unit for version B, C, D, E, F, G, V, N, P 110–127/220–240 V – Order quantity For 1 set or 1 unit 1 unit D D 3WX31 56–1JG01 3WX31 56–1JJ01 1 unit 1 unit 0.500 0.500 1 unit A 3WX36 47–5JA01 1 unit 1.300 Transfer control device for automatic switchover between two fixed-mounted or withdrawable circuit-breakers (see Page 5/95) 1 unit D 3WX36 66–7JA00 1 unit 11.400 Door sealing frame 1 unit A 3WX36 86–0JA00 1 unit 1.000 Also suitable for electronic trip units of 3WN1 and 3WS1 circuit-breakers 5/108 Siemens LV 30 · 2004 * This quantity or a multiple thereof can be ordered.