Download APEX User Manual, sn.. - Argo Information Centre
Transcript
APEX records a profile during ascent (ie upcast). Bottom pressure may change due to several causes, such variation of insitu density, internal waves, float grounding in shallows, change of float mass, etc. APEX automatic depth adjustment will compensate in most, but not all, cases. The number of sample points taken is proportional to depth, as per sample depth table below. The first (i.e. deepest) sample is taken at the first point in the depth table above bottom pressure. Depth Table No. 38 Sample Pressure Sample Pressure Sample Pressure Point (dbar) Point (dbar) Point (dbar) Bottom 1 27 53 2000 340 90 2 28 54 1900 330 85 3 29 55 1800 320 80 4 30 56 1700 310 75 5 31 57 1600 300 70 6 32 58 1500 290 65 7 33 59 1400 280 60 8 34 60 1300 270 55 9 35 61 1200 260 50 10 36 62 1100 250 45 11 37 63 1000 240 40 12 38 64 900 230 35 13 39 65 800 220 30 14 40 66 700 210 25 15 41 67 650 200 20 16 42 68 600 190 15 17 43 69 550 180 10 18 44 70 500 170 7 19 45 71 480 160 4 or surf 20 46 460 150 21 47 440 140 22 48 420 130 23 49 400 120 24 50 380 110 25 51 360 100 26 52 350 95 * The SeaBird CTD is not sampled at zero pressure, to avoid pumping the cell dry and/or ingesting surface oil slicks. The shallowest profile point is taken at either 4 dbar or at the last recorded surface pressure plus 5 dbar, whichever value is larger. 9