Download Contents
Transcript
Instructions for the installer 9.6.2 Adjusting the minimum setting for LPG To adjust the minimum setting with LPG, you must tighten the screw inside or next to the tap rod (depending on the model) fully in a clockwise direction. The bypass diameters for each individual burner are shown in table “9.2 Adjustment for LPG”. After adjustment with a gas other than the preset one, replace the label on the casing of the appliance with the label corresponding to the new gas. The label is inserted inside the pack together with the nozzles. 45