Download SH-8008(FIT)H

Transcript
F&eIT Series
10M/100M AUTO-MDIX
Switching HUB
(8-port)
SH-8008(FIT)H
User’s Manual
CONTEC CO.,LTD.
Check Your Package
Thank you for purchasing the CONTEC product.
The product consists of the items listed below.
Check, with the following list, that your package is complete. If you discover damaged or missing items,
contact your retailer.
Product Configuration List
- Unit…1
- Interface connector plug…1
- This User’s Manual …1
- EU Declaration of Conformity…1
POWER
FG+
5 - 24VDC
ViVi+
LED : LINK/ACT
Orange : 10M
Green : 100M
User’s Manual
1
2
1
2
EU Declaration
of Conformity
3
4
3
4
5
6
5
6
7
8
7
8
SH-8008H
Unit
Interface connector plug
SH-8008(FIT)H
User’s Manual
EU Declaration
of Conformity
i
Copyright
Copyright 2005 CONTEC CO., LTD. ALL RIGHTS RESERVED.
No part of this document may be copied or reproduced in any form by any means without prior written
consent of CONTEC CO., LTD.
CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this
document. The information in this document is subject to change without notice.
All relevant issues have been considered in the preparation of this document. Should you notice an
omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD.
Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may
appear in this document or for results obtained by the user as a result of using this product.
Trademarks
Other brand and product names are trademarks of their respective holder.
ii
SH-8008(FIT)H
Table of Contents
Check Your Package............................................................................................................................ i
Copyright ............................................................................................................................................ ii
Trademarks ......................................................................................................................................... ii
Table of Contents .............................................................................................................................. iii
1.
Before Using the Product
1
About the Unit .................................................................................................................................... 1
Features........................................................................................................................................ 1
Customer Support ............................................................................................................................... 2
Web Site....................................................................................................................................... 2
Limited One-Year Warranty............................................................................................................... 2
How to Obtain Service ....................................................................................................................... 2
Liability .............................................................................................................................................. 2
Safety Precautions .............................................................................................................................. 3
Safety Information....................................................................................................................... 3
Handling Precautions................................................................................................................... 4
Environment ................................................................................................................................ 5
Inspection..................................................................................................................................... 5
Storage ......................................................................................................................................... 5
Disposal ....................................................................................................................................... 5
2.
Nomenclature of unit Components and Their Settings
7
Names of unit Components ................................................................................................................ 7
3.
Installation and Connection
9
Installation Method............................................................................................................................. 9
Mounting on a DIN Rail.............................................................................................................. 9
Connection Method .......................................................................................................................... 12
Supplying the Power to the Switching HUB Unit .................................................................... 12
4.
Connecting to a Network
13
Network Cables ................................................................................................................................ 13
Connecting a Personal Computer, another HUB unit or bridge ...................................................... 13
Limitations on the 100M HUB.................................................................................................. 13
Limitations on the 10M HUB.................................................................................................... 14
5.
System Reference
15
Specification ..................................................................................................................................... 15
SH-8008(FIT)H
iii
External Dimensions......................................................................................................................... 17
iv
SH-8008(FIT)H
1. Before Using the Product
1. Before Using the Product
This chapter provides information you should know before using the product.
About the Unit
SH-8008(FIT)H is an IEEE-802.3(Ethernet)/IEEE-802.3u(Fast Ethernet) compliant, 8-port switching
HUB unit, equipped with full-duplex communication support, AutoMDI/MDI-X feature, and
auto-recognition function of communication rates (10Mbps/100Mbps) and communication methods
(half/full duplex) by the auto-negotiation feature. SH-8008(FIT)H uses Category 3 or 5, 5e, 6 UTP
(unshielded twist pair) cables, or STP (shielded twist pair) cables. For 100Mbps transfer rate, use cables
equal to or greater than Category 5.
Please read this manual carefully so that you can build a system by connecting the Switching Hub Unit to
external devices.
Features
-
The Switching HUB Unit's auto-negotiation feature automatically recognizes communication rates
and communication methods, thus permits a connection to devices such as F&eIT series controller
modules <CPU-CAxx(FIT)GY*1, CPU-SBxx/xxx(FIT)GY*1> and I/O Assist Server unit
<SVR-IOAx(FIT)GY*1>. It also provides eight AutoMDI/MDI-X ports.
-
Similar to other F&eIT series products, the system, in the unit itself, incorporates a 35-mm DIN rail
mounting mechanism as a standard item.
-
Equipped with FG pin for power supply connector.
*1
The Assist Server is available in different product models. "x" in each model number represents a blank or one numeric character.
(This is applicable to the rest of this document.)
SH-8008(FIT)H
1
1. Before Using the Product
Customer Support
CONTEC provides the following support services for you to use CONTEC products more efficiently and
comfortably.
Web Site
Japanese
English
Chinese
http://www.contec.co.jp/
http://www.contec.com/
http://www.contec.com.cn/
Latest product information
CONTEC provides up-to-date information on products.
CONTEC also provides product manuals and various technical documents in the PDF.
Free download
You can download updated driver software and differential files as well as sample programs available in
several languages.
Note! For product information
Contact your retailer if you have any technical question about a CONTEC product or need its price,
delivery time, or estimate information.
Limited One-Year Warranty
CONTEC F&eIT products are warranted by CONTEC CO., LTD. to be free from defects in material and
workmanship for up to one year from the date of purchase by the original purchaser.
Repair will be free of charge only when this product is returned freight prepaid with a copy of the
original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group office,
from which it was purchased.
This warranty is not applicable for scratches or normal wear, but only for the electronic circuitry and
original products. The warranty is not applicable if the device has been tampered with or damaged
through abuse, mistreatment, neglect, or unreasonable use, or if the original invoice is not included, in
which case repairs will be considered beyond the warranty policy.
How to Obtain Service
For replacement or repair, return the device freight prepaid, with a copy of the original invoice. Please
obtain a Return Merchandise Authorization Number (RMA) from the CONTEC group office where you
purchased before returning any product.
*
No product will be accepted by CONTEC group without the RMA number.
Liability
The obligation of the warrantor is solely to repair or replace the product. In no event will the warrantor
be liable for any incidental or consequential damages due to such defect or consequences that arise from
inexperienced usage, misuse, or malfunction of this device.
2
SH-8008(FIT)H
1. Before Using the Product
Safety Precautions
Understand the following definitions and precautions to use the product safely.
Safety Information
This document provides safety information using the following symbols to prevent accidents resulting in
injury or death and the destruction of equipment and resources. Understand the meanings of these labels
to operate the equipment safely.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury or in property damage.
SH-8008(FIT)H
3
1. Before Using the Product
Handling Precautions
CAUTION
-
Do not modify the unit. CONTEC will bear no responsibility for any problems, etc., resulting from
modifying this unit.
-
Do not use or store the equipment in a hot or cold place, or in a place that is subject to severe
temperature changes. (Operating temperature range: 0 - 50°C)
-
Do not use or store the equipment in a place subject to direct sunlight or near a heating device, such
as a stove.
-
Do not use or store the equipment in a dusty or humid place. (Operating humidity range: 10 - 90%,
no condensation)
-
As this product contains precision electronic components, do not use or store in environments
subject to shock or vibration.
-
Do not use or store the product near equipment generating a strong magnetic field or radio waves.
-
If you notice any strange odor or overheating, please unplug the power cord immediately.
-
In the event of an abnormal condition or malfunction, please consult the dealer from whom the
equipment was purchased.
-
To avoid electric shock, please do not touch the system with a wet hand.
-
Do not open the unit casing. CONTEC will disclaim any responsibility for equipment whose casing
has been opened.
-
Do not modify the product. CONTEC will bear no responsibility for any problems, etc., resulting
from modifying this product.
-
Regardless of the foregoing statements, CONTEC is not liable for any damages whatsoever
(including damages for loss of business profits) arising out of the use or inability to use this
CONTEC product or the information contained herein.
FCC PART 15 Class A Notice
NOTE
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference at his own expense.
WARNING TO USER
Change or modifications not expressly approved the manufacturer can void the user's authority to
operate this equipment.
4
SH-8008(FIT)H
1. Before Using the Product
Environment
Use this product in the following environment. If used in an unauthorized environment, the board may
overheat, malfunction, or cause a failure.
Operating temperature
0 - 50°C
Operating humidity
10 - 90%RH(No condensation)
Corrosive gases
None
Floating dust particles
Not to be excessive
Inspection
Inspect the product periodically as follows to use it safely.
*The ventilation slits are not covered,
and neither dust nor alien substance is attached to the ventilation slits
POWER
FG
5 - 24VDC
ViVi+
LED : LINK/ACT
Orange : 10M
Green : 100M
1
2
1
2
3
4
3
4
5
6
5
6
7
8
7
8
SH-8008H
Storage
When storing this product, keep it in its original packing form.
(1) Put the unit in the storage bag.
(2) Wrap it in the packing material, then put it in the box.
(3) Store the package at room temperature at a place free from direct sunlight, moisture, shock,
vibration, magnetism, and static electricity.
Disposal
When disposing of the product, follow the disposal procedures stipulated under the relevant laws and
municipal ordinances.
SH-8008(FIT)H
5
1. Before Using the Product
6
SH-8008(FIT)H
2. Nomenclature of unit Components and Their Settings
2. Nomenclature of unit Components and
Their Settings
Names of unit Components
Figure 2.1 shows the nomenclature of unit components.
POWER
Power supply connector
FG
5 - 24VDC
ViVi+
LED : LINK/ACT
Orange : 10M
Green : 100M
1
2
LED Indicator
1
2
3
4
3
4
5
6
10BASE-T/100BASE-TX port
5
6
7
8
7
8
SH-8008H
Figure 2.1. Names of unit Components
Table 2.1. LED Indicators
LED name
Comm. status LED
POWER LED
Number of LED
LINK/ACT :
ORANGE(8) :10M
GREEN(8) :100M
POWER: GREEN (1)
LED display
OFF : Not connected to Ethernet
ON : Connected to Ethernet
Flashing : Communicating
OFF : Power off
ON : Power on
Table 2.2. Connectors
Name
10BASE-T/
100BASE-TX port
Power supply
connector
SH-8008(FIT)H
Function
Ports 1 - 8
This is the port for connecting the PC (LAN Adapter) and other HUB units
and bridges.
Auto-switching of communication rates (10Mbps/100Mbps) and
communication methods (half/full duplex)
2-piece power supply detachable connector, FG pin
Dedicated plug (MC1.5/3-ST-3.5, made by PHOENIX CONTACT Corp.)
as a standard item.
Screw-in cable connection.
7
2. Nomenclature of unit Components and Their Settings
8
SH-8008(FIT)H
3. Installation and Connection
3. Installation and Connection
Installation Method
Mounting on a DIN Rail
Mounting procedure
(1) Pushing the fixing hook with a flat-blade screwdriver renders it into a lock-enabled condition.
35mmDIN rail
Press here to lift the fixing hook
Figure 3.1. Mounting on a DIN rail < 1 / 3 >
(2) Hook the unit from the upper part of the DIN rail, and press the lower part of the unit onto the DIN
rail.
Side view
Figure 3.1 Mounting on a DIN rail < 2 / 3 >
SH-8008(FIT)H
9
3. Installation and Connection
(3) The fixing hook is automatically locked, and the unit can be mounted in one-touch.
Fixing hook
Side view
Figure 3.1. Mounting on a DIN rail < 3 / 3 >
10
SH-8008(FIT)H
3. Installation and Connection
Removal procedures
(1) Lower the fixing hook for the unit to unlock it.
35mmDIN rail
Figure 3.2. Removing the unit from the DIN rail < 1 / 3 >
(2) With the fixing hook unlocked, pull the lower part of the unit toward you.
Side view
Figure 3.2. Removing the unit from the DIN rail < 2 / 3 >
(3) By lifting the unit, you can easily remove it from the DIN rail.
Side view
Figure 3.2. Removing the unit from the DIN rail < 3 / 3 >
SH-8008(FIT)H
11
3. Installation and Connection
Connection Method
Supplying the Power to the Switching HUB Unit
The Switching HUB Unit and power supply unit (POW-DD10GY, etc) can be cable connected using the
detachable connector that is provided on either the unit face or the unit face.
Keep the cable length no greater than 50cm (for AWG24 - 16). (no greater than 20cm for AGW28, no
greater than 35cm for AWG26).
Compatible cables are AWG28 - 16. Strip the cable jacket off about 7mm. The fastening torque for the
cable core should be 0.22 - 0.25Nm.
Third-party DC output power supply units can also be connected in the same way.
CAUTION
-
Because the power supply unit generates heat, a minimum spacing of 2.0 cm should be provided
between the SH-8008(FIT)H and any adjoining units, and care should be taken so that the
ventilation holes are not covered.
-
Input power requirements of the SH-8008(FIT)H: 5 - 24VDC±5%, 0.54 - 0.15A (Max.)
Cable connection
POWER
POWER
FG
Vo+
5 - 24VDC
5VDC Vo-
ViVi+
FG
LED : LINK/ACT
Orange : 10M
Green : 100M
1
2
1
2
3
4
3
4
5
10 - 30VDC
6
VoFG
5
6
Vo+
7
8
7
8
POW-DD10
SH-8008H
Figure 3.3. Connecting the Switching HUB Unit to the DC-DC power supply unit
12
SH-8008(FIT)H
4. Connecting to a Network
4. Connecting to a Network
Network Cables
Cables meeting the following specifications should be used:
-
Equal to or greater than Categor 3 UTP, STP cable (for 10BASE-T)
-
Equal to or greater than Categor 5 UTP, STP cable (for 100BASE-TX)
-
There are straight/cross UTP and STP cables. Auto MDI/MDI-X feature allows connection of your
Switching HUB unit to a personal computer (LAN adapter) or another HUB unit and a bridges using
either a straight or cross cable.
Connecting a Personal Computer, another HUB
unit or bridge
When connecting the Switching HUB unit to a personal computer, an F&eIT series contoroller unit,
another HUB unit or a bridge, use any 10BASE-T/100BASE-TX port and either a straight or cross cable.
SH-8008(FIT)H
CPU-CA20(FIT)GY,
CPU-CA10(FIT)GY
Straight cable
Figure 4.1. Connecting example to a personal computer, another HUB unit, or a controller unit
Limitations on the 100M HUB
In the case of a 100BASE-TX HUB(ClassII), the HUB can be cascade-connected for a maximum of two
levels. The maximum allowable cable length per segment is 205 meters.
SH-8008(FIT)H
100BASE-TX HUB
(Class II)
(1)
100BASE-TX HUB
(Class II)
(2)
- For cables (1), (2), (3), use category 5UTP cables.
(3)
- The total length of cables (1), (2), (3) should be no more than 205 meters.
Figure 4.2. Limitations on the 100M HUB
SH-8008(FIT)H
13
4. Connecting to a Network
Limitations on the 10M HUB
In the case of a 10BASE-T HUB, the number of HUB that can be connected in a cascading fashion using
UTP cables is 4 levels. The maximum allowable UTP cable length between cascade-connected HUB is
100 meters.
SH-8008(FIT)H
10BASE-T HUB
Figure 4.3. Limitations on the 10M HUB
14
SH-8008(FIT)H
5. System Reference
5. System Reference
Specification
Table 5.1. Specifications
Item
Ethernet standards
Specification
IEEE802.3/IEEE802.3u -compliant
Data transfer rate
10Mbps/100Mbps (auto-recognition)
Access method
CSMA/CD
Communications method
All ports: full/half duplex (auto-switching)
Topology
Star topology
Flow control
FullDuplex : IEEE802.3x compliant flow control
HalfDuplex : Back pressure
Number of effective ports
8
Switching method
Store and forward
Address table
1,024 entries
Queue buffer
512Kbyte
Aging time
200 - 300 Sec
LED indicator
POWER(green), Link/ACT 10M(orange), Link/ACT 100M(green)
Filtering rate
8,130pps (in case of 10Mbps)/148,800pps (in case of 100Mbps)
Forwarding rate
8,130pps (in case of 10Mbps)/148,800pps (in case of 100Mbps)
Power supply voltage
5V - 24VDC±5%
Use of a F&eIT series power supply unit recommended; or an
off-the-shelf stabilized power supply unit
FG pin
Power supply connector equipped with FG pin
Power consumption (Max.)
For 5V input : 0.54A, For 12V input : 0.22A, For 24V input : 0.15A
External dimensions (mm)
52.4(W) x 64.7(D) x 94.0(H) (exclusive of protrusions)
Weight
160g
Module installation method
One-touch attachment of a 35mm DIN rail.
Attachment mechanism contained in the system unit as a
standard item
SH-8008(FIT)H
15
5. System Reference
Table 5.2. Installation Environment Requirements
Item
Operating temperature
Specification
0 - 50°C
Storage temperature
-10 - 60°C
Humidity
10 - 90%RH(No condensation)
Floating dust particles
Not to be excessive
Corrosive gases
None
Line-Noise
resistance
Vibration
resistance
Line-noise *1
AC line/2kV, Signal line/1kV (IEC1000-4-4Level 3, EN61000-4-4Level 3)
Static electricity
resistance
Contact discharge/4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2)
Atmospheric discharge/8kV (IEC1000-4-2Level 3, EN61000-4-2Level 3)
Sweep resistance
10 - 57Hz/semi-amplitude 0.15mm,57 - 150Hz/2.0G
40minutes each in X, Y, and Z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
Impact resistance
15G, half-sine shock for 11ms in X, Y, and Z directions
Grounding
Class D grounding (previous class 3 grounding)
(JIS C0041-compliant, IEC68-2-27-compliant)
*1 POW-AD22GY is used.
16
SH-8008(FIT)H
5. System Reference
External Dimensions
14.0
14
31.5
(1.2)
POWER
FG
Vi-
LED : LINK/ACT
Orange : 10M
Green : 100M
Vi+
35.0
5 -24VDC
1
2
1
3
3
94
2
4
4
5
5
45.0
6
6
7
8
7
8
SH-8008H
52.4
64.7
4
[mm]
Figure 5.1. External dimensions
SH-8008(FIT)H
17
SH-8008(FIT)H
User’s Guide
CONTEC CO., LTD.
February 2010 Edition
3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan
Japanese http://www.contec.co.jp/
English http://www.contec.com/
Chinese http://www.contec.com.cn/
No part of this document may be copied or reproduced in any form by any means without prior written
consent of CONTEC CO., LTD.
[02052010]
[07062005]
02052010_rev2
Management No. A-40-675
Parts No.