Download SH-8008(FIT)H
Transcript
F&eIT Series 10M/100M AUTO-MDIX Switching HUB (8-port) SH-8008(FIT)H User’s Manual CONTEC CO.,LTD. Check Your Package Thank you for purchasing the CONTEC product. The product consists of the items listed below. Check, with the following list, that your package is complete. If you discover damaged or missing items, contact your retailer. Product Configuration List - Unit…1 - Interface connector plug…1 - This User’s Manual …1 - EU Declaration of Conformity…1 POWER FG+ 5 - 24VDC ViVi+ LED : LINK/ACT Orange : 10M Green : 100M User’s Manual 1 2 1 2 EU Declaration of Conformity 3 4 3 4 5 6 5 6 7 8 7 8 SH-8008H Unit Interface connector plug SH-8008(FIT)H User’s Manual EU Declaration of Conformity i Copyright Copyright 2005 CONTEC CO., LTD. ALL RIGHTS RESERVED. No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this document. The information in this document is subject to change without notice. All relevant issues have been considered in the preparation of this document. Should you notice an omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD. Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may appear in this document or for results obtained by the user as a result of using this product. Trademarks Other brand and product names are trademarks of their respective holder. ii SH-8008(FIT)H Table of Contents Check Your Package............................................................................................................................ i Copyright ............................................................................................................................................ ii Trademarks ......................................................................................................................................... ii Table of Contents .............................................................................................................................. iii 1. Before Using the Product 1 About the Unit .................................................................................................................................... 1 Features........................................................................................................................................ 1 Customer Support ............................................................................................................................... 2 Web Site....................................................................................................................................... 2 Limited One-Year Warranty............................................................................................................... 2 How to Obtain Service ....................................................................................................................... 2 Liability .............................................................................................................................................. 2 Safety Precautions .............................................................................................................................. 3 Safety Information....................................................................................................................... 3 Handling Precautions................................................................................................................... 4 Environment ................................................................................................................................ 5 Inspection..................................................................................................................................... 5 Storage ......................................................................................................................................... 5 Disposal ....................................................................................................................................... 5 2. Nomenclature of unit Components and Their Settings 7 Names of unit Components ................................................................................................................ 7 3. Installation and Connection 9 Installation Method............................................................................................................................. 9 Mounting on a DIN Rail.............................................................................................................. 9 Connection Method .......................................................................................................................... 12 Supplying the Power to the Switching HUB Unit .................................................................... 12 4. Connecting to a Network 13 Network Cables ................................................................................................................................ 13 Connecting a Personal Computer, another HUB unit or bridge ...................................................... 13 Limitations on the 100M HUB.................................................................................................. 13 Limitations on the 10M HUB.................................................................................................... 14 5. System Reference 15 Specification ..................................................................................................................................... 15 SH-8008(FIT)H iii External Dimensions......................................................................................................................... 17 iv SH-8008(FIT)H 1. Before Using the Product 1. Before Using the Product This chapter provides information you should know before using the product. About the Unit SH-8008(FIT)H is an IEEE-802.3(Ethernet)/IEEE-802.3u(Fast Ethernet) compliant, 8-port switching HUB unit, equipped with full-duplex communication support, AutoMDI/MDI-X feature, and auto-recognition function of communication rates (10Mbps/100Mbps) and communication methods (half/full duplex) by the auto-negotiation feature. SH-8008(FIT)H uses Category 3 or 5, 5e, 6 UTP (unshielded twist pair) cables, or STP (shielded twist pair) cables. For 100Mbps transfer rate, use cables equal to or greater than Category 5. Please read this manual carefully so that you can build a system by connecting the Switching Hub Unit to external devices. Features - The Switching HUB Unit's auto-negotiation feature automatically recognizes communication rates and communication methods, thus permits a connection to devices such as F&eIT series controller modules <CPU-CAxx(FIT)GY*1, CPU-SBxx/xxx(FIT)GY*1> and I/O Assist Server unit <SVR-IOAx(FIT)GY*1>. It also provides eight AutoMDI/MDI-X ports. - Similar to other F&eIT series products, the system, in the unit itself, incorporates a 35-mm DIN rail mounting mechanism as a standard item. - Equipped with FG pin for power supply connector. *1 The Assist Server is available in different product models. "x" in each model number represents a blank or one numeric character. (This is applicable to the rest of this document.) SH-8008(FIT)H 1 1. Before Using the Product Customer Support CONTEC provides the following support services for you to use CONTEC products more efficiently and comfortably. Web Site Japanese English Chinese http://www.contec.co.jp/ http://www.contec.com/ http://www.contec.com.cn/ Latest product information CONTEC provides up-to-date information on products. CONTEC also provides product manuals and various technical documents in the PDF. Free download You can download updated driver software and differential files as well as sample programs available in several languages. Note! For product information Contact your retailer if you have any technical question about a CONTEC product or need its price, delivery time, or estimate information. Limited One-Year Warranty CONTEC F&eIT products are warranted by CONTEC CO., LTD. to be free from defects in material and workmanship for up to one year from the date of purchase by the original purchaser. Repair will be free of charge only when this product is returned freight prepaid with a copy of the original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group office, from which it was purchased. This warranty is not applicable for scratches or normal wear, but only for the electronic circuitry and original products. The warranty is not applicable if the device has been tampered with or damaged through abuse, mistreatment, neglect, or unreasonable use, or if the original invoice is not included, in which case repairs will be considered beyond the warranty policy. How to Obtain Service For replacement or repair, return the device freight prepaid, with a copy of the original invoice. Please obtain a Return Merchandise Authorization Number (RMA) from the CONTEC group office where you purchased before returning any product. * No product will be accepted by CONTEC group without the RMA number. Liability The obligation of the warrantor is solely to repair or replace the product. In no event will the warrantor be liable for any incidental or consequential damages due to such defect or consequences that arise from inexperienced usage, misuse, or malfunction of this device. 2 SH-8008(FIT)H 1. Before Using the Product Safety Precautions Understand the following definitions and precautions to use the product safely. Safety Information This document provides safety information using the following symbols to prevent accidents resulting in injury or death and the destruction of equipment and resources. Understand the meanings of these labels to operate the equipment safely. DANGER DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. SH-8008(FIT)H 3 1. Before Using the Product Handling Precautions CAUTION - Do not modify the unit. CONTEC will bear no responsibility for any problems, etc., resulting from modifying this unit. - Do not use or store the equipment in a hot or cold place, or in a place that is subject to severe temperature changes. (Operating temperature range: 0 - 50°C) - Do not use or store the equipment in a place subject to direct sunlight or near a heating device, such as a stove. - Do not use or store the equipment in a dusty or humid place. (Operating humidity range: 10 - 90%, no condensation) - As this product contains precision electronic components, do not use or store in environments subject to shock or vibration. - Do not use or store the product near equipment generating a strong magnetic field or radio waves. - If you notice any strange odor or overheating, please unplug the power cord immediately. - In the event of an abnormal condition or malfunction, please consult the dealer from whom the equipment was purchased. - To avoid electric shock, please do not touch the system with a wet hand. - Do not open the unit casing. CONTEC will disclaim any responsibility for equipment whose casing has been opened. - Do not modify the product. CONTEC will bear no responsibility for any problems, etc., resulting from modifying this product. - Regardless of the foregoing statements, CONTEC is not liable for any damages whatsoever (including damages for loss of business profits) arising out of the use or inability to use this CONTEC product or the information contained herein. FCC PART 15 Class A Notice NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference at his own expense. WARNING TO USER Change or modifications not expressly approved the manufacturer can void the user's authority to operate this equipment. 4 SH-8008(FIT)H 1. Before Using the Product Environment Use this product in the following environment. If used in an unauthorized environment, the board may overheat, malfunction, or cause a failure. Operating temperature 0 - 50°C Operating humidity 10 - 90%RH(No condensation) Corrosive gases None Floating dust particles Not to be excessive Inspection Inspect the product periodically as follows to use it safely. *The ventilation slits are not covered, and neither dust nor alien substance is attached to the ventilation slits POWER FG 5 - 24VDC ViVi+ LED : LINK/ACT Orange : 10M Green : 100M 1 2 1 2 3 4 3 4 5 6 5 6 7 8 7 8 SH-8008H Storage When storing this product, keep it in its original packing form. (1) Put the unit in the storage bag. (2) Wrap it in the packing material, then put it in the box. (3) Store the package at room temperature at a place free from direct sunlight, moisture, shock, vibration, magnetism, and static electricity. Disposal When disposing of the product, follow the disposal procedures stipulated under the relevant laws and municipal ordinances. SH-8008(FIT)H 5 1. Before Using the Product 6 SH-8008(FIT)H 2. Nomenclature of unit Components and Their Settings 2. Nomenclature of unit Components and Their Settings Names of unit Components Figure 2.1 shows the nomenclature of unit components. POWER Power supply connector FG 5 - 24VDC ViVi+ LED : LINK/ACT Orange : 10M Green : 100M 1 2 LED Indicator 1 2 3 4 3 4 5 6 10BASE-T/100BASE-TX port 5 6 7 8 7 8 SH-8008H Figure 2.1. Names of unit Components Table 2.1. LED Indicators LED name Comm. status LED POWER LED Number of LED LINK/ACT : ORANGE(8) :10M GREEN(8) :100M POWER: GREEN (1) LED display OFF : Not connected to Ethernet ON : Connected to Ethernet Flashing : Communicating OFF : Power off ON : Power on Table 2.2. Connectors Name 10BASE-T/ 100BASE-TX port Power supply connector SH-8008(FIT)H Function Ports 1 - 8 This is the port for connecting the PC (LAN Adapter) and other HUB units and bridges. Auto-switching of communication rates (10Mbps/100Mbps) and communication methods (half/full duplex) 2-piece power supply detachable connector, FG pin Dedicated plug (MC1.5/3-ST-3.5, made by PHOENIX CONTACT Corp.) as a standard item. Screw-in cable connection. 7 2. Nomenclature of unit Components and Their Settings 8 SH-8008(FIT)H 3. Installation and Connection 3. Installation and Connection Installation Method Mounting on a DIN Rail Mounting procedure (1) Pushing the fixing hook with a flat-blade screwdriver renders it into a lock-enabled condition. 35mmDIN rail Press here to lift the fixing hook Figure 3.1. Mounting on a DIN rail < 1 / 3 > (2) Hook the unit from the upper part of the DIN rail, and press the lower part of the unit onto the DIN rail. Side view Figure 3.1 Mounting on a DIN rail < 2 / 3 > SH-8008(FIT)H 9 3. Installation and Connection (3) The fixing hook is automatically locked, and the unit can be mounted in one-touch. Fixing hook Side view Figure 3.1. Mounting on a DIN rail < 3 / 3 > 10 SH-8008(FIT)H 3. Installation and Connection Removal procedures (1) Lower the fixing hook for the unit to unlock it. 35mmDIN rail Figure 3.2. Removing the unit from the DIN rail < 1 / 3 > (2) With the fixing hook unlocked, pull the lower part of the unit toward you. Side view Figure 3.2. Removing the unit from the DIN rail < 2 / 3 > (3) By lifting the unit, you can easily remove it from the DIN rail. Side view Figure 3.2. Removing the unit from the DIN rail < 3 / 3 > SH-8008(FIT)H 11 3. Installation and Connection Connection Method Supplying the Power to the Switching HUB Unit The Switching HUB Unit and power supply unit (POW-DD10GY, etc) can be cable connected using the detachable connector that is provided on either the unit face or the unit face. Keep the cable length no greater than 50cm (for AWG24 - 16). (no greater than 20cm for AGW28, no greater than 35cm for AWG26). Compatible cables are AWG28 - 16. Strip the cable jacket off about 7mm. The fastening torque for the cable core should be 0.22 - 0.25Nm. Third-party DC output power supply units can also be connected in the same way. CAUTION - Because the power supply unit generates heat, a minimum spacing of 2.0 cm should be provided between the SH-8008(FIT)H and any adjoining units, and care should be taken so that the ventilation holes are not covered. - Input power requirements of the SH-8008(FIT)H: 5 - 24VDC±5%, 0.54 - 0.15A (Max.) Cable connection POWER POWER FG Vo+ 5 - 24VDC 5VDC Vo- ViVi+ FG LED : LINK/ACT Orange : 10M Green : 100M 1 2 1 2 3 4 3 4 5 10 - 30VDC 6 VoFG 5 6 Vo+ 7 8 7 8 POW-DD10 SH-8008H Figure 3.3. Connecting the Switching HUB Unit to the DC-DC power supply unit 12 SH-8008(FIT)H 4. Connecting to a Network 4. Connecting to a Network Network Cables Cables meeting the following specifications should be used: - Equal to or greater than Categor 3 UTP, STP cable (for 10BASE-T) - Equal to or greater than Categor 5 UTP, STP cable (for 100BASE-TX) - There are straight/cross UTP and STP cables. Auto MDI/MDI-X feature allows connection of your Switching HUB unit to a personal computer (LAN adapter) or another HUB unit and a bridges using either a straight or cross cable. Connecting a Personal Computer, another HUB unit or bridge When connecting the Switching HUB unit to a personal computer, an F&eIT series contoroller unit, another HUB unit or a bridge, use any 10BASE-T/100BASE-TX port and either a straight or cross cable. SH-8008(FIT)H CPU-CA20(FIT)GY, CPU-CA10(FIT)GY Straight cable Figure 4.1. Connecting example to a personal computer, another HUB unit, or a controller unit Limitations on the 100M HUB In the case of a 100BASE-TX HUB(ClassII), the HUB can be cascade-connected for a maximum of two levels. The maximum allowable cable length per segment is 205 meters. SH-8008(FIT)H 100BASE-TX HUB (Class II) (1) 100BASE-TX HUB (Class II) (2) - For cables (1), (2), (3), use category 5UTP cables. (3) - The total length of cables (1), (2), (3) should be no more than 205 meters. Figure 4.2. Limitations on the 100M HUB SH-8008(FIT)H 13 4. Connecting to a Network Limitations on the 10M HUB In the case of a 10BASE-T HUB, the number of HUB that can be connected in a cascading fashion using UTP cables is 4 levels. The maximum allowable UTP cable length between cascade-connected HUB is 100 meters. SH-8008(FIT)H 10BASE-T HUB Figure 4.3. Limitations on the 10M HUB 14 SH-8008(FIT)H 5. System Reference 5. System Reference Specification Table 5.1. Specifications Item Ethernet standards Specification IEEE802.3/IEEE802.3u -compliant Data transfer rate 10Mbps/100Mbps (auto-recognition) Access method CSMA/CD Communications method All ports: full/half duplex (auto-switching) Topology Star topology Flow control FullDuplex : IEEE802.3x compliant flow control HalfDuplex : Back pressure Number of effective ports 8 Switching method Store and forward Address table 1,024 entries Queue buffer 512Kbyte Aging time 200 - 300 Sec LED indicator POWER(green), Link/ACT 10M(orange), Link/ACT 100M(green) Filtering rate 8,130pps (in case of 10Mbps)/148,800pps (in case of 100Mbps) Forwarding rate 8,130pps (in case of 10Mbps)/148,800pps (in case of 100Mbps) Power supply voltage 5V - 24VDC±5% Use of a F&eIT series power supply unit recommended; or an off-the-shelf stabilized power supply unit FG pin Power supply connector equipped with FG pin Power consumption (Max.) For 5V input : 0.54A, For 12V input : 0.22A, For 24V input : 0.15A External dimensions (mm) 52.4(W) x 64.7(D) x 94.0(H) (exclusive of protrusions) Weight 160g Module installation method One-touch attachment of a 35mm DIN rail. Attachment mechanism contained in the system unit as a standard item SH-8008(FIT)H 15 5. System Reference Table 5.2. Installation Environment Requirements Item Operating temperature Specification 0 - 50°C Storage temperature -10 - 60°C Humidity 10 - 90%RH(No condensation) Floating dust particles Not to be excessive Corrosive gases None Line-Noise resistance Vibration resistance Line-noise *1 AC line/2kV, Signal line/1kV (IEC1000-4-4Level 3, EN61000-4-4Level 3) Static electricity resistance Contact discharge/4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2) Atmospheric discharge/8kV (IEC1000-4-2Level 3, EN61000-4-2Level 3) Sweep resistance 10 - 57Hz/semi-amplitude 0.15mm,57 - 150Hz/2.0G 40minutes each in X, Y, and Z directions (JIS C0040-compliant, IEC68-2-6-compliant) Impact resistance 15G, half-sine shock for 11ms in X, Y, and Z directions Grounding Class D grounding (previous class 3 grounding) (JIS C0041-compliant, IEC68-2-27-compliant) *1 POW-AD22GY is used. 16 SH-8008(FIT)H 5. System Reference External Dimensions 14.0 14 31.5 (1.2) POWER FG Vi- LED : LINK/ACT Orange : 10M Green : 100M Vi+ 35.0 5 -24VDC 1 2 1 3 3 94 2 4 4 5 5 45.0 6 6 7 8 7 8 SH-8008H 52.4 64.7 4 [mm] Figure 5.1. External dimensions SH-8008(FIT)H 17 SH-8008(FIT)H User’s Guide CONTEC CO., LTD. February 2010 Edition 3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan Japanese http://www.contec.co.jp/ English http://www.contec.com/ Chinese http://www.contec.com.cn/ No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. [02052010] [07062005] 02052010_rev2 Management No. A-40-675 Parts No. LYEM652