Download ReFreeX user manual for H424V3

Transcript
X
e
ree
RF
H424V3
User manual
doc H424V3
Contents
Contents
2
1 Parameter list
3
2 Parameter remarks
6
3 Alarm list
7
4 Slave alarm list
7
5 Button list
7
6 Led list
7
7 Soft command list
7
8 How to ...
7
9 Shortcut list
8
10 Led and push button location
8
The LATEX source of this document has been automatically produced by 4_13_22 on 2015-11-27
page 2\8
doc H424V3
1
Parameter list
Rem. Parameter
S__
St_
_t0
_td
Fd_
Fd0
Fdd
Fdg
FdE
1
FdP
FdY
FF_
FFh
FFd
2
FFo
FP_
FPt
3
4
5
6
7
8
9
10
11
12
13
14
FPc
FPM
FPS
FPX
FPY
Ft_
Ftt
n__
nE_
nEH
nEF
nEg
c__
cP_
cPH
cPF
cPd
cI_
cIH
cIo
cId
v__
vP_
vPH
vPP
vPd
vt_
vtt
vtH
vtL
vtU
vd_
vd1
vd2
vdd
b__
b1_
b1C
b1A
b2_
b2C
b2A
b3_
b3C
b3A
b4_
b4C
b4A
L__
Lt_
LtL
LtH
Ltd
LO_
Description
Minimum Maximum Default Unit
Functions about storage
Functions about storage temperature
storage room temperature
-55.0
145.0
2.0 ◦ C
differential
0.0
50.0
0.2 K
Functions about defrost duration and timing
immediate delay before next defrost
0 194 4:20:15
0 dd hh:mm:ss
on-time duration of the defrost
0 194 4:20:15 30:00 dd hh:mm:ss
dripping time after defrost
0 194 4:20:15
2:00 dd hh:mm:ss
evaporator fan activation delay after the defrost
0 194 4:20:15
7:00 dd hh:mm:ss
overall period of the defrost
0 194 4:20:15 4:00:00 dd hh:mm:ss
temperature display timeout after end of defrost - resets IA1=OS4=OS5
0 194 4:20:15 20:00 dd hh:mm:ss
Functions about forced defrost
enable forced defrost by keyboard short cut
oFF
_on
_on /
forced defrost duration
0 194 4:20:15 30:00 dd hh:mm:ss
start immediate forced defrost
oFF
_on
oFF /
Functions about defrost preference
defrost type: 0=none / 1=pause / 2=air / 3=electric / 4=hot gas / 5=heat pump /
0
4
2 /
6=heat pump by hp
use door closure input as start command for remote defrost
oFF
_on
oFF /
this side is defrost master (the instrument is divided in two sides)
oFF
_on
oFF /
this side is defrost slave
oFF
_on
oFF /
this side is defrost slave from aux master (0 means from main master - 255 whatever)
0
255
0 /
this side is defrost slave from side nr. (255 means whatever)
1
255
1 /
Functions about defrost temperature
defrost stop temperature
-55.0
145.0
6.0 ◦ C
Functions about fans
Functions about evaporator fans
force evaporator fans when refrigeration is off
oFF
_on
oFF /
enable evaporator fans during defrost
oFF
_on
oFF /
enable evaporator fans during dripping
oFF
_on
oFF /
Functions about door and light
Door switch and evaporator fan
stop evaporator fans when door is open
oFF
_on
_on /
pause defrost timer when air defrost is suspended by evaporator fan stop
oFF
_on
_on /
delay of fan automatic switch on
0 194 4:20:15 30:00 dd hh:mm:ss
Functions about light
switch on the light when the door is open and off when closed
oFF
_on
_on /
switch off the light automatically if it has been switched on from outside
oFF
_on
_on /
delay of light automatic switch off
0 194 4:20:15
30 dd hh:mm:ss
Functions about electronic expansion valve
Functions about electronic expansion valve preference
enable electronic expansion valve
oFF
_on
_on /
refrigerant gas type: 0=R134A / 1=R404A / 2=R507A / 3=R22 / 4=R407C
0
4
0 /
network originating address of the pressure broadcast
0
255
0 /
Functions about electronic expansion valve temperature
wanted overheating (similar to Danfoss thermostatic overheating spring regulation)
-999.0
999.0
8.0 K
maximum overheating
-999.0
999.0
99.0 K
minimum overheating
-999.0
999.0
6.0 K
maximum pressure allowed in the suction line (similar to Danfoss MOP)
0.0
999.0
10.0 (gauge) bar
Functions about electronic expansion valve timing
on-off duty cycle duration
0 194 4:20:15
8 dd hh:mm:ss
on duty cycle duration at refrigeration start (set to 0 for previous stop value)
0 194 4:20:15
5 dd hh:mm:ss
on duty cycle adaptation speed (low value for slow adaptation and small swinging)
0
255
8 /
Functions about probe calibration
Probe nr. 1
room temperature
-999.0
999.0
0.0 K
enable probe
oFF
_on
_on /
Probe nr. 2
defrost temperature
-999.0
999.0
0.0 K
enable probe
oFF
_on
_on /
Probe nr. 3
suction temperature
-999.0
999.0
0.0 K
enable probe
oFF
_on
_on /
Probe nr. 4
unused temperature - eventually used by Id4
-999.0
999.0
0.0 K
enable probe
oFF
_on
_on /
Functions about alarm and stand-by
Temperature alarm
low temperature alarm set point
-55.0
145.0
-2.0 ◦ C
high temperature alarm set point
-55.0
145.0
14.0 ◦ C
alarm delay
0 194 4:20:15 30:00 dd hh:mm:ss
Door alarm
The LATEX source of this document has been automatically produced by 4_13_22 on 2015-11-27
page 3\8
doc H424V3
Rem. Parameter
LOH
LOd
LOt
Lo_
Loo
P__
Pd_
PdM
PdS
PdX
PdY
I__
IA_
IA1
IA2
IA3
IA4
Id_
Id2
Id3
Id4
Id5
OS_
OS1
OS2
OS3
OS4
OS5
OSn
OSS
OSF
OSb
OSY
OSX
LLA
Od_
15
Od1
15
Od3
15
Od5
15
Od6
E__
Ed_
EdS
EdX
EY_
EYY
EYr
EYF
EYt
E0_
E0d
E0E
E1_
E1d
E1t
E1E
E2_
E2d
E2t
E2E
E3_
E3d
E3t
E3E
E4_
E4d
E4t
E4E
E5_
E5d
E5t
E5E
E6_
E6d
Description
enable door alarm
door alarm delay
temperature alarm minimum delay after door opening
On / stand-by status
actual status: stand-by or on
Functions about master preferences
Functions about network address
master address for global network communication
number of slaves connected to this master
number of aux masters connected to this master - 0 means no aux connected
this master is the auxiliary nr. - 0 means it is not aux
Functions about input-output and machine state (read only)
Analog inputs
room temperature
defrost temperature
suction temperature
unused temperature - eventually used by Id4
Digital input
evaporator hardware safety
defrost hardware safety
digital input 4 (door closure / remote defrost) - read by IA4
phase software safety
Machine status
low pressure (LP)
refrigerant saturation temperature corresponding to the low pressure
refrigerant overheating at the evaporator outlet
temperature before defrost - reads IA1 at range reentering after defrost
set point temperature during defrost - reads IA1 at range reentering after defrost
evaporator fan stopped by door opening or manual control
defrost status: 1=normal / 2=defr / 3=drip / 4=fan delay / 5=forced / 6=wait
defrost timer (in countdown-mode)
special defrost display in progress - affects OS4 and OS5 (see FdY)
timer of the temperature display timeout, after the end of defrost (see FdY)
communication alarm: 0=normal / 87=out of range / 88=no link / 89=lost link
actual alarm - read only (0 means no alarm)
Digital output
solenoid
light
evaporator
defrost
Functions about slave preferences
Functions about network address
slave address for local network communication
auxiliary master served by this slave - 0 means it is not aux
Functions about display
input to show on display: 1=IA1 / 2=IA2 ... / 5=OS1 / 6=OS2 ...
enable display rotation: 0=off / 1=all / 2=selected
display special text during defrost
label of special text during defrost
Functions about display rotation, when EYr=1
duration of label display during rotation
duration of value display during rotation
Functions about display rotation, when EYr=2 (repeated for each parameter)
duration of label display during rotation
label text during rotation
duration of value display during rotation
Functions about display rotation, when EYr=2 (repeated for each parameter)
duration of label display during rotation
label text during rotation
duration of value display during rotation
Functions about display rotation, when EYr=2 (repeated for each parameter)
duration of label display during rotation
label text during rotation
duration of value display during rotation
Functions about display rotation, when EYr=2 (repeated for each parameter)
duration of label display during rotation
label text during rotation
duration of value display during rotation
Functions about display rotation, when EYr=2 (repeated for each parameter)
duration of label display during rotation
label text during rotation
duration of value display during rotation
Functions about display rotation, when EYr=2 (repeated for each parameter)
duration of label display during rotation
The LATEX source of this document has been automatically produced by 4_13_22 on 2015-11-27
Minimum Maximum Default Unit
oFF
_on
_on /
0 194 4:20:15 30:00 dd hh:mm:ss
0 194 4:20:15 15:00 dd hh:mm:ss
oFF
_on
oFF /
0
1
0
0
254
2
31
31
1
2
0
0
-55.0
-55.0
-55.0
-55.0
145.0
145.0
145.0
145.0
-55.0
-55.0
-55.0
-55.0
oFF
oFF
oFF
oFF
_on
_on
_on
_on
oFF
oFF
oFF
oFF
/
/
/
/
◦C
◦C
◦C
◦C
/
/
/
/
0.0
999.0
0.0 (gauge) bar
-55.0
145.0
-55.0 ◦ C
-999.0
999.0 -999.0 K
-55.0
145.0
-55.0 ◦ C
-55.0
145.0
-55.0 ◦ C
oFF
_on
oFF /
0
6
0 /
0 194 4:20:15
0 dd hh:mm:ss
oFF
_on
oFF /
0 194 4:20:15
0 dd hh:mm:ss
0
255
0 /
0
255
0 /
oFF
oFF
oFF
oFF
_on
_on
_on
_on
oFF
oFF
oFF
oFF
/
/
/
/
1
0
254
255
1
0
0
000
9
2
1
yyy
0
0
255
255
1 /
2 /
0
000
0
255
yyy
255
0 /
rM= /
6 /
0
000
0
255
yyy
255
1 /
dE= /
0 /
0
000
0
255
yyy
255
1 /
SU= /
0 /
0
000
0
255
yyy
255
1 /
do= /
0 /
0
000
0
255
yyy
255
1 /
LP= /
4 /
0
255
1 /
1 /
0 /
1
0
0
dEF
/
/
/
/
page 4\8
doc H424V3
Rem. Parameter
E6t
E6E
E7_
E7d
E7t
E7E
E8_
E8d
E8t
E8E
E9_
E9d
E9t
E9E
Eb_
EbH
S__
St_
_t0
_td
Fd_
Fd0
Fdd
Fdg
FdE
1
FdP
FdY
FF_
FFh
FFd
2
FFo
FP_
FPt
3
4
5
6
7
8
9
10
11
12
FPc
FPM
FPS
FPX
FPY
Ft_
Ftt
n__
nE_
nEH
nEF
nEg
c__
cP_
cPH
cPF
cPd
cI_
cIH
cIo
cId
v__
vP_
vPH
vPP
vPd
vt_
vtt
vtH
vtL
vtU
vd_
vd1
vd2
vdd
b__
b1_
b1C
b1A
b2_
Description
Minimum Maximum Default Unit
label text during rotation
000
yyy
Lt= /
duration of value display during rotation
0
255
0 /
Functions about display rotation, when EYr=2 (repeated for each parameter)
duration of label display during rotation
0
255
1 /
label text during rotation
000
yyy
oh= /
duration of value display during rotation
0
255
0 /
Functions about display rotation, when EYr=2 (repeated for each parameter)
duration of label display during rotation
0
255
1 /
label text during rotation
000
yyy
bF= /
duration of value display during rotation
0
255
0 /
Functions about display rotation, when EYr=2 (repeated for each parameter)
duration of label display during rotation
0
255
1 /
label text during rotation
000
yyy
SF= /
duration of value display during rotation
0
255
0 /
Functions about buzzer
enable buzzer
0
1
1 /
Functions about storage
Functions about storage temperature
storage room temperature
-55.0
145.0
2.0 ◦ C
differential
0.0
50.0
0.2 K
Functions about defrost duration and timing
immediate delay before next defrost
0 194 4:20:15
0 dd hh:mm:ss
on-time duration of the defrost
0 194 4:20:15 30:00 dd hh:mm:ss
dripping time after defrost
0 194 4:20:15
2:00 dd hh:mm:ss
evaporator fan activation delay after the defrost
0 194 4:20:15
7:00 dd hh:mm:ss
overall period of the defrost
0 194 4:20:15 4:00:00 dd hh:mm:ss
temperature display timeout after end of defrost - resets IA1=OS4=OS5
0 194 4:20:15 20:00 dd hh:mm:ss
Functions about forced defrost
enable forced defrost by keyboard short cut
oFF
_on
_on /
forced defrost duration
0 194 4:20:15 30:00 dd hh:mm:ss
start immediate forced defrost
oFF
_on
oFF /
Functions about defrost preference
defrost type: 0=none / 1=pause / 2=air / 3=electric / 4=hot gas / 5=heat pump /
0
4
2 /
6=heat pump by hp
use door closure input as start command for remote defrost
oFF
_on
oFF /
this side is defrost master (the instrument is divided in two sides)
oFF
_on
oFF /
this side is defrost slave
oFF
_on
oFF /
this side is defrost slave from aux master (0 means from main master - 255 whatever)
0
255
0 /
this side is defrost slave from side nr. (255 means whatever)
1
255
1 /
Functions about defrost temperature
defrost stop temperature
-55.0
145.0
6.0 ◦ C
Functions about fans
Functions about evaporator fans
force evaporator fans when refrigeration is off
oFF
_on
oFF /
enable evaporator fans during defrost
oFF
_on
oFF /
enable evaporator fans during dripping
oFF
_on
oFF /
Functions about door and light
Door switch and evaporator fan
stop evaporator fans when door is open
oFF
_on
_on /
pause defrost timer when air defrost is suspended by evaporator fan stop
oFF
_on
_on /
delay of fan automatic switch on
0 194 4:20:15 30:00 dd hh:mm:ss
Functions about light
switch on the light when the door is open and off when closed
oFF
_on
_on /
switch off the light automatically if it has been switched on from outside
oFF
_on
_on /
delay of light automatic switch off
0 194 4:20:15
30 dd hh:mm:ss
Functions about electronic expansion valve
Functions about electronic expansion valve preference
enable electronic expansion valve
oFF
_on
_on /
refrigerant gas type: 0=R134A / 1=R404A / 2=R507A / 3=R22 / 4=R407C
0
4
0 /
network originating address of the pressure broadcast
0
255
0 /
Functions about electronic expansion valve temperature
wanted overheating (similar to Danfoss thermostatic overheating spring regulation)
-999.0
999.0
8.0 K
maximum overheating
-999.0
999.0
99.0 K
minimum overheating
-999.0
999.0
6.0 K
maximum pressure allowed in the suction line (similar to Danfoss MOP)
0.0
999.0
10.0 (gauge) bar
Functions about electronic expansion valve timing
on-off duty cycle duration
0 194 4:20:15
8 dd hh:mm:ss
on duty cycle duration at refrigeration start (set to 0 for previous stop value)
0 194 4:20:15
5 dd hh:mm:ss
on duty cycle adaptation speed (low value for slow adaptation and small swinging)
0
255
8 /
Functions about probe calibration
Probe nr. 1
room temperature
-999.0
999.0
0.0 K
enable probe
oFF
_on
_on /
Probe nr. 2
The LATEX source of this document has been automatically produced by 4_13_22 on 2015-11-27
page 5\8
doc H424V3
Rem. Parameter
b2C
b2A
b3_
b3C
b3A
b4_
b4C
b4A
L__
Lt_
13
LtL
14
LtH
Ltd
LO_
LOH
LOd
LOt
Lo_
Loo
I__
IA_
IA1
IA2
IA3
IA4
Id_
Id2
Id3
Id4
Id5
OS_
OS1
OS2
OS3
OS4
OS5
OSn
OSS
OSF
OSb
OSY
OSX
LLA
Od_
15
Od1
15
Od3
15
Od5
15
Od6
2
Nr.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Description
defrost temperature
enable probe
Probe nr. 3
suction temperature
enable probe
Probe nr. 4
unused temperature - eventually used by Id4
enable probe
Functions about alarm and stand-by
Temperature alarm
low temperature alarm set point
high temperature alarm set point
alarm delay
Door alarm
enable door alarm
door alarm delay
temperature alarm minimum delay after door opening
On / stand-by status
actual status: stand-by or on
Functions about input-output and machine state (read only)
Analog inputs
room temperature
defrost temperature
suction temperature
unused temperature - eventually used by Id4
Digital input
evaporator hardware safety
defrost hardware safety
digital input 4 (door closure / remote defrost) - read by IA4
phase software safety
Machine status
low pressure (LP)
refrigerant saturation temperature corresponding to the low pressure
refrigerant overheating at the evaporator outlet
temperature before defrost - reads IA1 at range reentering after defrost
set point temperature during defrost - reads IA1 at range reentering after defrost
evaporator fan stopped by door opening or manual control
defrost status: 1=normal / 2=defr / 3=drip / 4=fan delay / 5=forced / 6=wait
defrost timer (in countdown-mode)
special defrost display in progress - affects OS4 and OS5 (see FdY)
timer of the temperature display timeout, after the end of defrost (see FdY)
communication alarm: 0=normal / 87=out of range / 88=no link / 89=lost link
actual alarm - read only (0 means no alarm)
Digital output
solenoid
light
evaporator
defrost
Minimum
-999.0
oFF
Maximum Default Unit
999.0
0.0 K
_on
_on /
-999.0
oFF
999.0
_on
0.0 K
_on /
-999.0
oFF
999.0
_on
0.0 K
_on /
-55.0
145.0
-55.0
145.0
0 194 4:20:15
-2.0 ◦ C
14.0 ◦ C
30:00 dd hh:mm:ss
oFF
_on
0 194 4:20:15
0 194 4:20:15
_on /
30:00 dd hh:mm:ss
15:00 dd hh:mm:ss
oFF
_on
oFF /
-55.0
-55.0
-55.0
-55.0
145.0
145.0
145.0
145.0
-55.0
-55.0
-55.0
-55.0
oFF
oFF
oFF
oFF
_on
_on
_on
_on
oFF
oFF
oFF
oFF
◦C
◦C
◦C
◦C
/
/
/
/
0.0
999.0
0.0 (gauge) bar
-55.0
145.0
-55.0 ◦ C
-999.0
999.0 -999.0 K
-55.0
145.0
-55.0 ◦ C
-55.0
145.0
-55.0 ◦ C
oFF
_on
oFF /
0
255
0 /
0 194 4:20:15
0 dd hh:mm:ss
oFF
_on
oFF /
0 194 4:20:15
0 dd hh:mm:ss
0
255
0 /
0
255
0 /
oFF
oFF
oFF
oFF
_on
_on
_on
_on
oFF
oFF
oFF
oFF
/
/
/
/
Parameter remarks
Remark
The period of each cycle includes on-time + off-time, that is the overall duration of the cycle.
Following defrost cycles will be aligned to the end of forced one.
For defrost synchronization of refrigerated expositors.
No action if the light is switched on from inside the room.
When off, the refrigeration solenoid is steadily on during cooling.
The address of the central unit who is broadcasting pressure (usually 1). Use 0 for previous application H425V1 with no origin specification.
Caution! Low overheating causes liquid return and compressor damage.
Overheating over the maximum forces valve anticipated opening.
Overheating under the minimum delays valve opening.
Caution! Short duty cycle reduces valve life.
Caution! Low overheating causes liquid return and compressor damage.
Caution! High adaptation speed causes swing in the suction line and damage to the compressor.
The low temperature differential is fixed, and alarm status stops at 0.2 ◦ C above the set point.
The high temperature differential is fixed, and alarm status stops at 0.2 ◦ C under the set point.
The minus sign on display ("-") signals that output is going to start after a delay.
The LATEX source of this document has been automatically produced by 4_13_22 on 2015-11-27
page 6\8
doc H424V3
3
Alarm list
Display
A01
A02
A03
A04
A05
A06
A07
Alarm
low temperature
high temperature
door open
RTC memory loss
Side 1 lost defrost
Side 2 lost defrost
Bad defr. par. side 1
A08
Bad defr. par. side 2
4
Slave alarm list
Display
A96
A97
A98
A99
5
Push
B1
B2
B3
B4
B5
B6
6
Led
L1
L2
L3
L4
L5
L6
L7
7
Alarm
slave EEPROM
out of range
no link
lost link
Failed write operation onto the slave EEPROM.
The slave address EdS might be out of the master range, the latter going from 1 to PdS.
The slave does not receive any message from the master.
The slave lost the communication with the master.
Button list
button
esc - silence
up
on/stand-by - pause
left - light
down - defrost
right - menu - set
Function
Exit without saving from any menu - alarm buzzer silence.
Up navigation in the menu.
Toggle between on and stand-by - toggle evaporator fan stop.
Left navigation in the menu - switch the light on and off.
Down navigation in the menu - force immediate defrost.
Right navigation in the menu - display and modify the set point - enter menu.
Led list
cooling
evaporator
defrost
unused
unused
unused
light
Function
On during cooling.
On during evaporator run - blinking slowly during activation delay.
On during defrost - blinking slowly during dripping.
Unused in this application.
Unused in this application.
Unused in this application.
On when lighting is on - blinking slowly during deactivation delay.
Soft command list
Soft command
8
Low temperature limit has been reached.
High temperature limit has been reached.
Time limit for door opening has been reached.
Memory loss of real time clock [RTC] - timer reset.
Side 1 of the instrument is defrost slave and does not receive any message from the defrost master.
Side 2 of the instrument is defrost slave and does not receive any message from the defrost master.
Bad defrost parameters for side 1 of the instrument, please ensure: Fdd+Fdg+FdE<FdP, 5 sec<FdP, not concurrent
FPS and FPM, nor FPS and FPc, nor PdX and PdY. Put FPt=0 to avoid this check.
Bad defrost parameters for side 2 of the instrument, please ensure: Fdd+Fdg+FdE<FdP, 5 sec<FdP, not concurrent
FPS and FPM, nor FPS and FPc, nor PdX and PdY. Put FPt=0 to avoid this check.
Function
How to ...
How to ...
Switch between on and stand-by.
Function
Keep pressed B3 button, to activate and deactivate stand-by. In stand-by every output is disabled except light,
leds from L1 to L6 blink, timers continue to count.
The LATEX source of this document has been automatically produced by 4_13_22 on 2015-11-27
page 7\8
doc H424V3
How to ...
Stop or restart evaporator fans.
Program the menu.
Show or change temperature set.
Force a defrost.
Shortcut list
Buttons to press
B5
10
Shortcut description - keep pressed 5 seconds
Force an immediate defrost.
Led and push button location
ReFreeX
L1 L2 L3 L4 L5 L6
B1
B2
L7
B4
B5
B3
Set
B6
doc A112X1
9
Function
Press shortly the B3 button. When the evaporator fans are stopped, the display blinks.
Keep pressed B6 to enter the menu. Navigate up and down with B2 and B5. Select the submenu by B6.
Change the parameter by B2 and B5, press B6 to confirm, or B4 to go back without saving. The changes
will have effect after the exit from programming pressing B4 repeatedly. Press B1 to exit immediately without
saving any parameter.
Press shortly B6 - the display shows the current set point - change it by B2 and B5, and confirm it by B6. As
alternative, enter the menu program as explained above, modify the parameter _t0, then confirm it.
Keep pressed B5.
80% refrigerant reduction – full digital control – reduced winter consumption
80% di riduzione del refrigerante – controllo digitale completo – consumi invernali ridotti
The LATEX source of this document has been automatically produced by 4_13_22 on 2015-11-27
page 8\8