Download SLE Accessories Catalogue

Transcript
SLE Accessories Catalogue
SLE Accessories and Consumables
for use in the Neonatal Unit
When the smallest thing matters
Contents
SLE2000 & SLE2000 HFO Ventilator Accessories............................................ 4
SLE350 & SLE500 Compressors..................................................................... 4
SLE4000 & SLE5000 Ventilator Accessories.................................................... 5
SLE3600 Inosys Nitric Oxide Therapy System Accessories.............................. 6
Nitric Oxide Circuits and Nebuliser kits............................................................ 6
Biomed NeO2 Blender..................................................................................... 6
SLE1000 nCPAP Driver Accessories................................................................ 7
Aeroneb Solo................................................................................................... 7
Patient Circuits................................................................................................ 8
Filters.............................................................................................................. 8
Procedure Packs............................................................................................. 9
Parts for Reusable Circuits.............................................................................. 9
Fisher & Paykel Accessories.......................................................................... 10
SLE1000 nCPAP Generator........................................................................... 11
Inca (Ventilator nCPAP) system, Cannulaide nasal seals................................. 12
Cannula securing devices and Skin preparation tabs..................................... 13
Miniflow (Ventilator nCPAP system)................................................................ 14
Disposable Humidifiers.................................................................................. 14
TSI Ventilator Test Systems............................................................................ 14
This catalogue is distributed world-wide, and not every product is available in every
country. Please check with your local distributor as to the availability of individual
products.
Items marked with this logo are available as a downloadable brochure or a data-sheet
at www.sle.co.uk If you are viewing this brochure as a PDF and are connected to the
Internet, then clicking on the icon will take you to the relevant English language datasheet (other languages may also be available).
When the smallest thing matters
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
3
SLE2000 & SLE2000 HFO
SLE2000
Infant ventilators & accessories
SLE2000 HFO
Part Number
N2191
Oxygen Sensor
N2186
Silencer
Description
N2191
Oxygen Sensor for use with SLE2000/HFO/HFO+
N2190
Exhalation block assembly for SLE2000
N0635
Exhalation block assembly for SLE2000 HFO
N0635/60
Exhalation block assembly for SLE2000 HFO+
N2186
Silencer - suitable for SLE2000, SLE2000 HFO AND SLE2000 HFO+
N2302
Hose hook for SLE2000/HFO/HFO+
Z0005
Water trap for air supply
N2035
Oxygen hose assembly (U.K.)
N2199
Air hose assembly (U.K.)
N2035/01
Oxygen hose assembly (Export)
N2199/01
Air hose assembly (Export)
N1770
Stand and pole assembly. Suitable for SLE2000, HFO and HFO+
N2328
Test Lung - suitable for all SLE ventilators
N2263
Blue metal restrictor for use with 15 mm reusable circuit.
N2266
Red metal restrictor for use with 10 mm reusable circuit.
N2190
Exhalation Block
for SLE2000
N2328
Test Lung
N2266
Red Restrictor
SLE350 & SLE500
Medical Air Compressors
Part Number
Description
L0350
SLE350 Suitable for use with SLE2000
L0500
SLE500 Suitable for SLE2000 HFO, SLE2000 HFO+, SLE4000 and
SLE5000
The SLE350 and SLE500 Air Compressors are an ideal air source for all SLE ventilators when piped-in
compressed air is not available or when you need a back-up air source for added protection.
Easily accessible filter and indicators make regular maintenance simple and cost effective. Large, lockable castors
provide effortless mobility and stability.
L0500
Compressor
4
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
SLE4000 & SLE5000
Infant ventilators & accessories
SLE4000
Part Number
Description
N6652
Medicart 5 - Deluxe Trolley for SLE4000/5000
N2328
Test Lung - suitable for all SLE ventilators
N6647
Silicone Test Lung suitable for SLE4000/5000
N5402
Autoclavable Flow Sensor for SLE4000/5000 (Each)
N5302/05
Single-use Flow Sensor for SLE4000/5000 (Box of 5)
N5302/50
Single-use Flow Sensor for SLE4000/5000 (Box of 50)
N6656
Flow Sensor Cable for SLE4000/5000 (Each)
N2186/01
Silencer for SLE4000/5000
N6622
Exhalation Block for SLE4000/5000
N6627/212
Patient Circuit Support Arm
N2266/50
Amber metal restrictor for use with 10 mm reusable circuit.
N2191/10
Oxygen Sensor for use with SLE4000/5000.
L0291
Oxygen Alarm Silencer (For Demonstration Use Only)
SLE5000
N2191/10
Oxygen Sensor
N5302
Single-use Flow Sensor
N5402
Autoclavable Flow Sensor
N6647
Silicon Test Lung
N6622
Exhalation Block
N2186/01
Silencer
N6627/212
Patient Circuit support arm
N6652
Medicart 5
Trolley
L0291
Oxygen Alarm Silencer
(For Demonstration Use Only)
N6656
Sensor Cable
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
5
SLE3600 Inosys Nitric Oxide System
(Not available in the UK)
For use with fixed-flow ventilators
SLE3600 Inosys
Part Number
Description
N6651
INOSYS System Trolley c/w bottle holders
Nitric Oxide Circuits & Nebuliser kits
Z4123
Inosys Calibration kit
Part Number
Description
BC6216
Nitric Oxide Delivery Kit for 3rd Party Delivery Systems
(Pack size - 1)
BC2110/KIT/5
Nitric Oxide Delivery Kit for use with Inosys and SLE2000/2000 HFO
(Pack size - 5)
BC3110/KIT/5
Nitric Oxide Delivery Kit for use with Inosys and SLE2000 HFO
(Pack size - 5)
BC4110/KIT/5
Nitric Oxide Delivery Kit for use with Inosys and SLE4000/5000
(Pack size - 5)
N4110/20
Nitric Oxide dual hose scavenging filter assembly for SLE2000 HFO/
2000 HFO+/ 4000/ 5000 infant Ventilators
(Pack size - 1)
BC2508/15
Nebuliser Kit 10 mm breathing circuits, for use with all SLE 10 mm BC
Circuits
(Pack size - 15)
BC2506/25
Nebuliser Kit 15 mm breathing circuits, for use with all SLE 15 mm BC
Circuits
(Pack size - 25)
Z4123
INOSYS Calibration kit - complete, disposable.
BC4110/KIT/5
Biomed - NEO2 Blend
Neonatal Air/Oxygen Blender
Part Number
Description
Z2003/FFEU
Low Flow Blender for neonatal use with bleed switch with dual flow
meters 1-15 l/min and 1-3.5 l/min 1.5m Oxygen hose with NIST fitting
1.5 m Air hose with NIST Fitting Medirail bracket with vertical/horizontal
positioning connector pack.
Z2003/FFE5
Low Flow Blender for neonatal use with bleed switch with dual flow
meter 1-15 l/min 1.5 m Oxygen hose with NIST fitting 1.5 m Air hose
with NIST fitting Medirail bracket with vertical/horizontal positioning
connector pack.
Z2003/FLEU
Low Flow Blender for neonatal use with bleed switch with single flow
meter 1-15 l/min and bleed switch 1.5 m Oxygen hose with NIST
Fitting 1.5 m Air hose with NIST fitting Medirail bracket with vertical/
horizontal positioning connector pack.
Z2003/FFE1
Low Flow Blender for neonatal use with bleed switch with dual flow
meters 1-15 l/min and 0-1 l/min. 1.5 m Oxygen hose with NIST Fitting
1.5 m Air hose with NIST fitting Medirail bracket with vertical/horizontal
positioning connector pack.
Air/Oxygen Blender
6
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
SLE1000
nCPAP Driver & accessories
Part Number
Description
L1009/014/000
SLE1000 Trolley complete with Drip pole, 2 locking wheels and
humidifier mounting
Z0010/DIS/EXP/4M
SLE1000 Air and Oxygen hose set. Set of 2, without hose end.
4m length (DISS)
Z0010/NST/EXP/4M
SLE1000 Air and Oxygen hose set. Set of 2, without hose end.
4m length (NIST)
Z0010/NST/UK/4M
SLE1000 Air and Oxygen hose set. Set of 2, with NIST hose end.
4m length (NIST)
Z0010/NST/UK/3M
SLE1000 Air and Oxygen hose set. Set of 2, with NIST hose end.
3m length (NIST)
SLE1000
Z1009/014/000
(Shown without Drip pole)
Aeroneb Solo
Nebuliser System
Part Number
Description
Z1025/NEB/0UK
Aeroneb Solo Starter Kit - UK includes Aeroneb Pro-X control module,
2 Aeroneb Solo nebulisers, 2 adult tee’s with plug, universal bracket,
equipment bracket, AC/DC adaptor and manual
Z1025/NEB/0IN
Aeroneb Solo Starter Kit - International includes Aeroneb Pro-X control
module, 2 Aeroneb Solo nebulisers, 2 adult tee’s with plug, universal
bracket, equipment bracket, European AC/DC adaptor and English
language manual
Z1025/NEB/0NE
Aeroneb Solo Starter Kit - Northern Europe (French, German, Dutch,
Italian) includes Aeroneb Pro-X control module, 2 Aeroneb Solo
nebulisers, 2 adult tee’s with plug, universal bracket, equipment bracket,
AC/DC adaptor and manual
Z1025/NEB/0SE
Aeroneb Solo Starter Kit - Southern Europe (Spanish, Italian,
Portuguese, Greek, Turkish) includes Aeroneb Pro-X control module,
2 Aeroneb Solo nebulisers, 2 adult tee’s with plug, universal bracket,
equipment bracket, AC/DC adaptor and manual
Z1025/NEB/0SC
Aeroneb Solo Starter Kit - Scandinavia (Swedish, Norwegian, Finnish,
Danish) includes Aeroneb Pro-X control module, 2 Aeroneb Solo
nebulisers, 2 adult tee’s with plug, universal bracket, equipment bracket,
AC/DC adaptor and manual
Z1025/NEB/0AU
Aeroneb Solo Starter Kit - Australia includes Aeroneb Pro-X control
module, 2 Aeroneb Solo nebulisers, 2 adult tee’s with plug, universal
bracket, equipment bracket, European AC/DC adaptor and English
language manual
N1025/100/005
Aeroneb Solo nebulisers (Pack of 5)
N1025/200/010
Aeroneb Solo nebulisers (Pack of 10)
N1025/035/010
Aeroneb Solo Neonatal Tee Pieces 12 mm M/12 mm F for use with
Fisher & Paykel neonatal breathing circuit - Pack of 10
N1025/036/010
Aeroneb Solo Neonatal Tee Pieces 10 mm M /10 mm F for use with
Intersurgical circuits (Pack of 10)
N1025/400/010
Aeroneb -disposable Luer connectors for continuous nebulisation (Pack of 10)
N1025/450/010
Aeroneb - Tee Piece plugs (Pack of 10)
L1025/NEB/KIT
Aeroneb Starter Kit for SLE4000 & SLE5000, Aeroneb Solo Neonatal
Tee Pieces 10 mm M/10 mm F (pack of 10), Aeroneb Solo Neonatal Tee
Pieces 12 mm M/12 mm F (Pack of 10)
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
Aeroneb Pro-X
control module and
nebuliser
7
Patient Circuits
For use with SLE Ventilators
Part Number
Description
SLE2000 and SLE2000 HFO circuits
BC5188/100/15
N2387
15 mm Reusable Heated Patient Circuit for use with SLE2000 and
SLE2000 HFO*
N2391
10 mm Reusable Heated Patient Circuit for use with SLE2000 and
SLE2000 HFO*
N2387/60
15 mm Reusable Heated Patient Circuit for use with SLE2000 HFO*
BC2188/100/15
10 mm Single Use Patient Circuit for use with SLE2000 and
SLE2000 HFO: temp port 100 mm from ET Manifold. (Pack size - 15)
BC2188/400/15
10 mm Single Use Patient Circuit for use with SLE2000 and
SLE2000 HFO: temp port 400 mm from ET Manifold. (Pack size - 15)
SLE2000 HFO+ circuits
BC5488/DHW/15
BC2198/100/15
15 mm Single Use Patient Circuit for use with SLE2000 HFO+:
temp port 100 mm from ET manifold. (Pack size - 15)
BC2198/400/15
15 mm Single Use Patient Circuit for use with SLE2000 HFO+: temp
port 400 mm from ET Manifold. (Pack size - 15) Replaces N2252
SLE4000 and SLE5000 circuits
N2391/50
10 mm Reusable Heated Patient Circuit for use with SLE5000*
N2387/50
15 mm Reusable Heated Patient Circuit for use with SLE5000*
BC5488/DHW/15
10 mm Single Use, Dual Heated Patient Circuit, smoothbore
tubing for use with SLE4000 and SLE5000. (Pack size - 15)
BC5188/400/15
10 mm Single Use Patient Circuit for use with SLE4000 and
SLE5000, temp port 400 mm from ET Manifold. (Pack size - 15)
Replaces N5188
BC5188/100/15
10 mm Single Use Patient Circuit for use with SLE4000 and
SLE5000, temp port 100 mm from ET Manifold. (Pack size - 15)
Replaces N5188/02
BC5198/100/15
15 mm Single Use Patient Circuit for use with SLE4000/5000,
temp port 100 mm from ET manifold. (Pack size -15)
BC5198/400/15
15 mm Single Use Patient Circuit for use with SLE4000/5000,
temp port 400 mm from ET manifold. (Pack size -15)
RT228/000/010
Fisher & Paykel RT228 Infant Breathing Circuit with chamber for
use with SLE4000/5000. (Box of 10)
RT228/000/010
* NB Reusable circuits must always be used with the correct reusable flow restrictor (see opposite)
Filters
For use with SLE Ventilators
N2587/000/50
Single Use Bacteria Filter
8
N2029
Autoclavable
Bacteria Filter
Part Number
Description
N2029
Autoclavable Fresh Gas Outlet Bacteria Filter for use with SLE5000,
SLE2000 & SLE2000 HFO (Each)
N2029/60
Autoclavable bacterial filter SLE2000 HFO+. (Each)
N2587/000/50
Single Use Bacteria Filter, suitable for all SLE ventilators. (Box of 50)
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
Procedure Packs
For use with SLE4000 and SLE5000 Ventilators
Part Number
Description
RT228/SEN/010
F&P RT228 circuit bundled with SLE 5302 flow sensor (Pack of 10)
BC5188/100/015/SEN
Intersurgical BC5188/100/15 circuit bundled with SLE 5302 flow
sensor (Pack of 15)
BC5188/400/015/SEN
Intersurgical BC5188/400/15 circuit bundled with SLE 5302 flow
sensor (Pack of 15)
BC5488/DHW/015/SEN
Intersurgical BC5488/DHW/15 circuit bundled with SLE 5302 flow
sensor (Pack of 15)
RT228/SEN/010
BC5188/100/015/SEN
Parts for Reusable Circuits
(Including Reusable Flow Restrictors)
Part Number
Description
N2030/200/001
Proximal Airway Pressure Line reusable
N2998/04
10 mm x 100 mm (Fresh gas port to fresh gas filter silicon tube)
N2998/10
10 mm x 250 mm (Extension Tube Restrictor to Temp Probe)
N2998/24
10 mm x 610 mm (Humidifier to Ventilator) reusable Silicon Tube
N2998/30
10 mm x 760 mm (Expiratory Manifold to Water Trap or Water Trap to
Exhalation Block) reusable Silicon Tube
N2998/48
10 mm x 1220 mm (Temperature Port to Chamber Connector)
reusable Silicon Tube
N3049
Hose Clip (Pack of 3)
N3071
Draw Wire for Heated Wire Insertion
N3139
Reusable Water trap
N3145
Reusable Neonatal Manifold
N3146
Tube Connector and Temperature Probe Assembly
N3148
Tube Connector Adaptor 10 mm Male to 10 mm Female
N3510
Reusable Heater Wire 1200 mm and Chamber Connector
N2266/50
Amber metal restrictor for use with 10 mm reusable circuit for SLE5000
N2263
Blue metal restrictor for use with 15 mm reusable circuit for SLE2000/
SLE2000 HFO/SLE2000 HFO+
N2266
Red metal restrictor for use with 10 mm reusable circuit for SLE2000/
SLE2000 HFO/SLE2000 HFO+
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
N3510
Heater wire and chamber
connector
N3049
Hose clips
N2266/50
Amber Restrictor
N3148
Tube connector adaptor
N3146
Temperature probe adaptor
9
Fisher & Paykel
Humidification systems
Z1012/31
MR850 humidifier
N3220/000/050
Single use chamber
N3290/01/40
Single use autofeed chamber
Part Number
Description
Z1002/11
or
Z1002/10 (UK)
F&P MR850 humidifier for use with reusable patient circuits
(Pole clamp) Fisher & Paykel MR850 heater base, pole clamp,
reusable chamber x 1, electrical adaptor MR858 x 1, airway
temperature probe, flow probe adaptor and user manual
Z1002/31
or
Z1002/30 (UK)
F&P MR850 humidifier for use with reusable patient circuits
(Medirail clamp) Fisher & Paykel MR850 heater base, Medirail
clamp, reusable chamber x 1, electrical adaptor MR859 x 1, airway
temperature probe, flow probe adaptor and user manual
Z1012/11
or
Z1012/10 (UK)
F&P MR850 humidifier for use with single use patient circuits
(Pole clamp) Fisher & Paykel MR850 heater base, pole clamp, single
use chamber x 1, electrical adaptor MR859 x 1, airway temperature
probe, flow probe adaptor and user manual
Z1012/31
or
Z1012/30 (UK)
F&P MR850 humidifier for use with single use patient circuits
(Medirail clamp) Fisher & Paykel MR850 heater base, Medirail
clamp, single use chamber x 1, electrical adaptor MR859 x 1, airway
temperature probe, flow probe adaptor and user manual
N3901
Heated wire adaptor for use with MR700 and SLE reusable patient
circuits with clover leaf connector (each)
N3030
Pole Clamp for F&P MR850 Humidification System (each)
N6627/08
Rail Clamp for F&P MR850 Humidification System (each)
N3220/000/050
F&P single use humidifier chamber MR225 (50 in a box).
N3290/01/40
F&P autofeed single use humidifier chamber MR290 (40 in a box)
N3340
F&P Reusable Humidification Chamber (each)
N3860
52” Temperature probe for use with MR850. (each) N3835
N3858
Electric adaptor for use with MR850 and SLE reusable patient circuits
N3859
Electric adaptor for use with MR850 and SLE single use patient circuits
with flying lead connector
N5600
Electric adaptor for use with MR850 and SLE single use patient circuits
with clover leaf connector
N5601
Electric adaptor for use with MR850 and SLE single use dual heater
wire patient circuits with clover leaf connectors
N5603
Electric adaptor for use with MR730 and SLE single use patient circuits
with clover leaf connector
N5604
Electric adaptor for use with MR730 and SLE single use dual heater
wire patient circuits with clover leaf connectors
N6627/08
Rail clamp
N3030
Pole clamp
10
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
SLE1000 nCPAP Generator
Nasal CPAP Generator with enhanced fluidic flow technology
Part Number
Description
Generators
BH6000/600/010
SLE1000 nCPAP Generator Only (inc 3 prongs). (Pack of 10)
BH6300/605/010
SLE1000 nCPAP Generator with Fisher & Paykel RT124 spiral heated
wire circuit. (Pack of 10)
BH6400/605/010
SLE1000 nCPAP Generator with Fisher & Paykel RT324 spiral heated
wire circuit and 290 autofill chamber. (Pack of 10)
BH6600/600/020
SLE1000 nCPAP Silencer. (Pack of 20)
RT124/000/010
Fisher & Paykel RT124 spiral heated wire circuit. (Pack of 10)
SLE1000 nCPAP
Generator
Prongs
BH1P00/600/010
SLE1000 nCPAP nasal prongs, small. (Pack of 10)
BH2P00/600/010
SLE1000 nCPAP nasal prongs, medium. (Pack of 10)
BH3P00/600/010
SLE1000 nCPAP nasal prongs, large. (Pack of 10)
BH6400/605/010 Kit
Masks
BH4M00/600/010
SLE1000 nCPAP masks, small. (Pack of 10)
BH5M00/600/010
SLE1000 nCPAP masks, medium. (Pack of 10)
BH6M00/600/010
SLE1000 nCPAP masks, large. (Pack of 10)
BH7M00/600/010
SLE1000 nCPAP masks, extra large. (Pack of 10)
Prongs
Bonnets
BH1000/600/010
l
SLE1000 nCPAP white bonnet, size 000. (Pack of 10)
BH0100/600/010
l
SLE1000 nCPAP grey bonnet, size 00. (Pack of 10)
BH0110/600/010
l
SLE1000 nCPAP pink bonnet, size 0. (Pack of 10)
BH0001/600/010
l
SLE1000 nCPAP brown bonnet, size 1. (Pack of 10)
BH0002/600/010
l
SLE1000 nCPAP yellow bonnet, size 2. (Pack of 10)
BH0003/600/010
l
SLE1000 nCPAP blue bonnet, size 3. (Pack of 10)
BH0004/600/010
l
SLE1000 nCPAP gold bonnet, size 4. (Pack of 10)
BH0005/600/010
l
SLE1000 nCPAP green bonnet, size 5. (Pack of 10)
BH0006/600/010
l
SLE1000 nCPAP burgundy bonnet, size 6. (Pack of 10)
BH0007/600/010
l
SLE1000 nCPAP orange bonnet, size 7. (Pack of 10)
BH0008/600/010
l
SLE1000 nCPAP dark green bonnet, size 8. (Pack of 10)
BH0009/600/010
l
SLE1000 nCPAP navy bonnet, size 9. (Pack of 10)
BH1000/STP/001
Bonnet Sampler pack. (Pack of 36)
(includes 3 of each bonnet size plus 10 x tapes)
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
Masks
Silencer
Bonnets
SLE1000 nCPAP
Generator and
bonnet in use
11
Inca
Nasal CPAP system
UK only
Part Number
Description
Includes: Choice of Nasal Cannulae Size, Stay Flex tubing, Knit Cap, Support Foam Blocks,
in-line T and straight Adaptor, Sterile Nasal Prongs.
Inca nCPAP System
N4427/07
Inca Nasal CPAP (Size 7.5) with nasal cannulae (Pack of 5)
N4427/09
Inca Nasal CPAP (Size 9.0) with nasal cannulae (Pack of 5)
N4427/10
Inca Nasal CPAP (Size 10.5) with nasal cannulae (Pack of 5)
N4427/12
Inca Nasal CPAP (Size 12.0) with nasal cannulae (Pack of 5)
N4427/15
Inca Nasal CPAP (Size 15.0) with nasal cannulae (Pack of 5)
Replacement Prongs
N4407/07
Replacement prongs and tubing. Size 7.5 (Pack of 5)
N4407/09
Replacement prongs and tubing. Size 9.0 (Pack of 5)
N4407/10
Replacement prongs and tubing. Size 10.5 (Pack of 5)
N4407/12
Replacement prongs and tubing. Size 12.0 (Pack of 5)
N4407/15
Replacement prongs and tubing. Size 15.0 (Pack of 5)
Adapts a ventilator circuit to give nasal CPAP.
Cannulaide
Nasal seal for infant nCPAP
UK only
Cannulaide
Nasal Seals
Part Number
Description
N4410/100/25
Size 0 for babies up to 700 g (Pack of 25)
N4410/101/25
Size 1 for babies between 700 g and 1250 g (Pack of 25)
N4410/102/25
Size 2 for babies between 1250 g and 2000 g (Pack of 25)
N4410/103/25
Size 3 for babies between 2000 g and 3000 g (Pack of 25)
N4410/104/25
Size 4 for babies more than 3000 g (Pack of 25)
Gentle hydrocolloid nasal seal aids continuous recruitment of alveoli and prevents damage to nasal
septum.
12
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
Neo-fit
Neonatal Endotracheal tube grip
Part Number
UK only
Description
Includes: Plastic Tube Grip with Adjustable Velcro Strap, Adhesive Foam Pads x 2 Foam Lollipop
Securing tapes
N4225/40
NEO-fit (packed non-sterile 20 in a box)
Provides rapid, secure stabilisation
N4225/40
NEO-fit ET tube grip
Neo-Prep
Neonatal skin preparation tabs
Part Number
UK only
Description
Includes: Plastic Tube Grip with Adjustable Velcro Strap, Adhesive Foam Pads x 2 Foam Lollipop
Securing tapes
N4480/00
NEO-prep skin barrier SMALL (Box of 10)
N4480/01
NEO-prep skin barrier LARGE (Box of 10)
Hypoallergenic skin barrier tabs precut to small and large sizes for use during nasal cannulae
procedures.
NEO-Prep
skin prep tabs
Sticky Whiskers
Nasal cannula securement device
Part Number
Description
N4406
Sticky Whiskers - Nasal cannula securement device (pack of 25)
N4406/MW1/001
Mini Whiskers - Nasal cannula securement device (pack of 25)
UK only
Gentle hydrocolloid adhesive strips to secure cannula in place directly under the infant’s nose
N4406
Sticky Whiskers
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
13
Medin Miniflow Kit
For nasal CPAP use with any Ventilator
Part Number
Description
Z1026/MNF/001
Miniflow nCPAP Generator kit for use with any ventilator
10 x Miniflow device with angled adaptor, head measuring tape and
includes:
Prongs micro - Qty 1. Prongs small - Qty 2. Prongs medium - Qty 2.
Prongs large - Qty 2. Prongs Xlarge - Qty 2. Prongs wide (Asia) - Qty 1
Neonatal mask small - Qty 1. Neonatal mask medium - Qty 1.
Neonatal Mask large - Qty 1. Bonnet xsmall - Qty 1. Bonnet small Qty 1. Bonnet medium - Qty - 1. Bonnet large - Qty 1.
Bonnet xlarge - Qty 1. Bonnett xxlarge - Qty 1.
Bonnet for fixation - Qty 1, T-piece - Qty 10
Medin
Miniflow
Humidification
Disposable Humidifiers
Part Number
Description
N2327
Disposable humidifiers (pack of 50)
N2327
Disposable Humidifier
TSI Ventilator Test Systems
Certifier Plus
Part Number
Description
Z4080
Certifier FA Plus, Flow Analyser System:
4088 Interface model and 4081 High Flow module kit
Z4073
Certifier FA, Oxygen Sensor kit (4073)
Z4082
Certifier FA Plus, Low Flow Module kit (4082)
A low cost portable test system capable of testing multiple parameters of ventilation performance
Z4080
Certifier FA Plus
14
Tel: +44 (0)20 8681 1414 • [email protected] • Fax: +44 (0)20 8649 8570 • www.sle.co.uk
SLE is a world leader in the
design and manufacture of
neonatal ventilators.
Years of ventilation experience
have given the company an
understanding of the challenges
facing nurses and clinicians when
caring for the tiniest and most
critical babies.
From being pioneers of neonatal
Patient Triggered Ventilation
(PTV) in the 1980’s, to the
introduction of combined HFO
(High Frequency Oscillation) in
the 1990’s, SLE has maintained
a position of strength in neonatal
ventilation.
The knowledge and experience
gained during years of
development is evident in all
of SLE’s products: the result of
our ongoing commitments to
innovation, competency and care.
G0052/0UK/001 04/12
SLE Limited.
Twin Bridges Business Park, 232 Selsdon Road,
South Croydon Surrey CR2 6PL UK
Telephone:+44 (0)20 8681 1414 • Fax: +44 (0)20 8649 8570
E-mail: [email protected] • Web: www.sle.co.uk