733HC-E Steam Sterilizer
QUICK REFERENCE POSTER
Jacket
Pressure
Gauge
Cycle Information
Chamber
Pressure
Gauge
YDF35(9$&
67$1'%<
([SRVXUH7LPH
([SRVXUH7LPH
&
'U\LQJ7LPH
Command Buttons
that Operate
the Sterilizer
3
3
)
&\FOHV
/RJLQ
0HQX
0RUH
2SHQ
&ORVH
6WRS
6WDUW
CONTROLS
OFF ⁄ ON
CONTROLS
OFF/ON
Printer
CONTROLS
DISABLE ⁄ ENABLE
CONTROLS
DISABLE/ENABLE
(with key)
USB Port
(behind panel
on right side)
TURNING THE STERILIZER ON/OFF
CONTROLS
DISABLE ⁄ ENABLE
Turn the key RIGHT to ENABLE
the controls.
Press CONTROLS OFF/ON to
turn the sterilizer ON (illuminated)
or OFF (not illuminated).
CONTROLS
OFF ⁄ ON
If the button is ILLUMINATED
but the display is OFF, touch the
screen to turn it ON.
Turn the key LEFT to DISABLE
the controls. Remove the key to
prevent unauthorized operation.
OPERATING THE DOOR
WARNING − BURN HAZARD
Steam released from the sterilizer chamber can cause
serious burns. Stand away while the door is moving.
Tap to unseal a sealed door.
P1
P2
Cycles

This status indicator displays
when all doors are sealed.
Select
Cycle
/RJLQ
1. Tap the Cycles button to
display the list of available
cycles.
5. Tap the Start button.
The In Process indicator
displays in the status area
while the cycle runs.
If necessary, you can cancel the cycle:
a. Tap the Stop button.
b. In the More screen, tap the Abort button.
Menu
Screen
WARNING
RISK OF BURNS, INJURY,
OR NONSTERILE ITEMS
This poster is a supplement
to the User Manual. It does
not list detailed instructions
or the hazards associated
with operating this equipment. For more instructions
and warnings, see the User
Manual (PN 61301606344).
61301606345 REV B US
2. In the main menu,
tap the Screen
button.
RISK OF NONSTERILE
DEVICE
You are responsible for any
cycles with settings other
than factory set parameters.
Use biological indicators (BI)
to verify cycle performance.
RISK OF NONSTERILE
DEVICE
If the cycle is canceled, it
must be considered incomplete and the load must be
reprocessed (unwrapped
goods or liquids) or repacked
and reprocessed (wrapped
goods).
0HQX
0RUH
2SHQ
&ORVH
Time
Remaining
in Cycle
7LPH
6WDUW
Start Cycle
EFFECTIVENESS OF THE CYCLE
Before you unload the sterilizer, determine
the effectiveness of the cycle.
COMPLETE AND SUCCESSFUL
The Cycle Complete button
displays. Tap it to silence the alert
sound.
The GREEN Process Complete
status indicator displays.
CYCLE COMPLETE displays in the cycle
information area.
----------------------------------------------------------------------------------------------------------------------------PROCESS
PROCESS END
END
11:15:06
11:15:06
CYCLE
CYCLE RESULTS
RESULTS
Exp.
135.5C
Exp. Temp
Temp Max
Max
135.5C
Exp.
135.3C
Exp. Temp
Temp Min
Min
135.3C
Time
Time at
at Exp
Exp Temp
Temp 00:03:13
00:03:13
DAILY
7
DAILY COUNTER
COUNTER
7
-------------------------------Parameter Check 73.5
00:28:34
14.33
00:28:34
14.33 101.4
101.4
CYCLE
CYCLE COMPLETE
COMPLETE
00:27:47
4.50
00:27:47
4.50 99.5
99.5
AIR-IN
AIR-IN
00:26:47
0.61
00:26:47
0.61 100.9
100.9
00:25:47
0.61
00:25:47
0.61 101.0
101.0
CYCLE COMPLETE
prints below the
CYCLE RESULTS.
The door unseals
and remains closed,
ready to open.
INCOMPLETE AND UNSUCCESSFUL
The Silence Alarm button
displays. Tap it to silence the
pulsing alarm.
The Process Failure status
indicator displays and a red
diagnostic message displays the
reason for the failure.
When the cycle ends, STANDBY displays in
the cycle information area.
The RED Process Incomplete
status indicator and the More
screen display.
SELECTING A PROCESS SCREEN
1. To change the process screen,
tap the Menu button.
3
3
)
&\FOHV
4. Check that the Start button is enabled
(green). If not, correct any failure
conditions and close all doors.
Stop
&
3. If necessary, edit the cycle’s parameters
(password required).
Start
-DFNHW7HPS
36,
2. Tap the button labeled with the correct
cycle for the load.
Tap to seal a closed door.
This status indicator displays
when all doors are closed but
at least one is not sealed.
&KDPEHU36,$
STERILIZING THE LOAD
Tap to close an open door.
Close
36,
'U\LQJ7LPH
The 733HC-E Steam Sterilizer is
designed to process hospital supplies.
For detailed operation information, read your
User Manual. Use this poster for quick reference
only.
Tap to open a closed door.
Open
&
GLVSOD\LQEOXHRUUHG
([SRVXUH7HPS
&
Touch
Screen
&
&KDPEHU7HPS
JUY*5$9,7<
(;32685(
3 ([SRVXUH7HPS
'LDJQRVWLFPHVVDJHV
3 Status Indicators
SIGNATURE: ..........
Circle Graph
Bar Graph
Plot Graph
3. In the Screen menu,
tap the button for the
desired process screen.
Details Graph
HOT SURFACES
The chamber, door, and
accessories may be hot
enough to cause burns.
Wear personal protective
equipment (PPE) when
loading and unloading the
chamber.
POSSIBILITY OF INJURY
Persons entering the chamber could become trapped.
Before entering the chamber, turn the CONTROLS
DISABLE/ENABLE key to
DISABLE, remove it, and
keep it with you.
POSSIBILITY OF INJURY
If a WATER IN DRAIN
message displays, DO
NOT operate the chamber
door. Hot water in the
chamber may spill if the
door is opened. Wait until
the message clears before
attempting to open the door.
RISK OF INFECTION
The Liquids Cycle is not
intended for the sterilization
of liquids intended for direct
patient contact.
-------------------------------CYCLE ABORTED
00:03:11
14.26 88.8
AIR-IN
00:03:00
14.24 89.1
DRYING
CYCLE ABORTED
prints.
The doors remain
sealed. Correct the
cause of the failure. Tap the CLEAR button.
Then unseal the door.
Before contacting Getinge USA Service, have qualified
maintenance personnel check the:
• steam supply: Is pressure adequate, strainer clogged?
• door gasket: Is it worn? Replace as necessary.
• chamber: Is drain screen clogged, screen missing?
• water supply: Is pressure adequate, strainer clogged?
• air filter: Is it dirty, clogged? Replace as necessary.
• electrical supply: Is circuit breaker lit?
If the problem persists, contact your Getinge USA
Service representative by: