Download to the pdf
Transcript
Europump Guideline Safety of Electrical Submersible Motors, 2000-08 metal conduits, they shall be contained within an insulating sleeve, unless the conduit cannot move in normal use. Compliance is checked by inspection and by manual test 16.3 Different parts of an appliance which can move in normal use or during user maintenance relative to each other, shall not cause undue stress to electrical connections and internal conductors, including those providing earthing continuity. Flexible metallic tubes shall not cause damage to the insulation of the conductors contained within them. Open-coil springs shall not be used to protect conductors. If a coiled spring, the turns of which touch one another, is used for this purpose, an adequate insulating lining shall be provided in addition to the insulation of the conductors. Compliance is checked by 16.4 Bare internal wiring shall be rigid and fixed so that, in normal use, creepage distances and clearances cannot be reduced below the values specified in 29.1. Compliance is checked during the test of 29.1. 16.5 The insulation of internal wiring shall withstand the electrical stress likely to occur in normal use. Compliance is checked as follows: The insulation shall be electrically equivalent to the insulation of cords complying with IEC 60227 or IEC 60245 or comply with the following electric strength test: A voltage of 2 000 V is applied for 15 min between the conductor and metal foil wrapped around the insulation. There shall be no breakdown. NOTES 1 If the insulation of the conductor does not fulfil one of these conditions, the conductor is considered to be bare. 2 The test is only applied to wiring subjected to the supply mains voltage. 16.6 When sleeving is used as supplementary insulation on internal wiring it shall be retained in position by positive means. Compliance is checked by inspection and by manual test. NOTE - A sleeve is considered to be fixed by positive means if it can only be removed by breaking or cutting or if it is clamped at both ends. 16.7 Conductors identified by the colour combination green / yellow shall only be used for earthing conductors. Compliance is checked by inspection. 16.8 Stranded conductors shall not be consolidated by lead-tin soldering where they are subjected to contact pressures unless the clamping means is constructed so that there is no risk of bad contact due to cold flow of the solder. Compliance is checked by inspection. NOTES Page - 25 -