INFRARED SYSTEM
USER MANUAL
Similar to the radio control, this infrared (IR) blocking system incorporates a safety code, meaning that
it is highly reliable when several machines are operating at the same time as any possible
interferences are avoided.
The coverage area of the IR system depends on the height of the IR transmitter and how many are
installed, as if the working range covered by one single IR transmitter is considered insufficient, more
transmitters can be installed thereby increasing the working range. The number of transmitters will
depend on the size of the surface area to be covered.
Because of the optical nature of infrared rays, in order for the IR receiver to correctly acknowledge the
IR transmitter signal, the transmitter should be located at a visible point and free of obstacles,
otherwise the signal will not be received.
The operation of this equipment is limited to covered areas, where there is no direct sunlight, as this
significantly reduces the working range of the infrared system. The delimited area will depend on the
application.
2. INSTALLATION OF THE INFRARED TRANSMITTER
To connect the transmitter, first remove the front cover, by pressing and turning it anti-clockwise. Then
unscrew the two fastening screws of the circuit to access the backside, where the input binding post is
located.
Input feed should be 48/115/230Vac 50Hz and will be connected to the binding posts of the CN3
connector. To select the correct voltage, close one of the jumpers J7, J8 or J9, as shown in figure 3.
The default configuration is a voltage of 230Vac (J9).
1A FUSE
48Vac
115Vac
230Vac
CURRENT FEED
J7
J8
J9
FUS1
CN3
FASTENING
SCREW
RS485 PORT
A
B
FASTENING
SCREW
Fig.3. Connections of the IR transmitter
2