INSTALLATION
INSTALLATION OF THIS APPLIANCE MUST CONFORM TO LOCAL CODES. IN THE ABSENCE OF LOCAL APPLICABLE CODES IT MUST COMPLY WITH THE NATIONAL FUEL GAS CODE, ANSI Z223.1, NATIONAL GAS INSTALLATION CODE, CAN/CGA-B149.1, OR THE PROPANE INSTALLATION CODE, CA/
CGA-B149.2, AS APPLICABLE, INCLUDING:
·
THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY SYSTEM WITH ITS INDIVIDUAL
MANUAL SHUT-OFF VALVE.
·
THE APPLIANCE AND ITS INDIVIDUAL SHUT-OFF VALVE MUST BE DISCONNECTED FROM
THE GAS SUPPLY SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST
PRESSURES IN EXCESS OF 0.5 PSI. (3.45 kPa).
·
THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY BY CLOSING ITS INDIVIDUAL
MANUAL SHUT-OFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING
SYSTEM AT TEST PRESSURES EQUAL TO OR LESS THAN 0.5 PSI (3.45 kPa).
OPERATION
SOME UNUSUAL CONDITIONS, SUCH AS NOT CLEANING THE CHAFF COLLECTOR AFTER EACH
ROAST, DRASTICALLY OVERFILLING THE ROAST CHAMBER, OR BLOCKING THE ROASTER
VENT, CAN CAUSE A FIRE IN THE ROASTING CHAMBER. DO NOT LEAVE THE ROASTER TO
RUN UNATTENDED. IN THE EVENT OF A FIRE, TURN OFF THE GAS SUPPLY AND ELECTRIC
POWER AND ALLOW THE ROASTER TO COOL COMPLETELY BEFORE TOUCHING IT.
TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT EXPOSE YOUR ROASTER TO
RAIN OR MOISTURE.
DO NOT REMOVE THE HOUSING COVER FROM THE ROASTER. THERE ARE NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
THIS IS A GAS FIRED APPLIANCE AND MUST NOT BE VENTED INTO A CLOSED SPACE. REFER
TO THE INSTALLATION PORTION OF THIS MANUAL FOR PROPER VENTING.
THE GLASS ROASTING CHAMBER AND THE METAL ABOVE THE ROASTING CHAMBER CAN
CAUSE BURNS IF TOUCHED DURING THE ROASTING CYCLE.
ROASTERS IDENTIFIED FOR USE WITH NATURAL GAS MUST NOT BE RUN ON PROPANE (LP).
DOING SO WOULD POSE A SERIOUS POTENTIAL FIRE HAZARD. BE SURE THAT YOU DO NOT
USE A GAS OTHER THAN THE ONE SPECIFIED ON THE NAMEPLATE OF YOUR ROASTER.