4-2 Function Mode
Register
No.
Function name
Parameter
No.
R/W
Function
10A6h
Allowable momentary power
interruption time
b002
R/W
3 to 250
0.1 [s]
10A7h
Retry wait time
b003
R/W
3 to 1000
0.1 [s]
10A8h
Momentary power
interruption/undervoltage
trip during stop selection
b004
R/W
00: Disabled
01: Enabled
⎯
10A9h
Momentary power
interruption retry time
selection
b005
R/W
00: 16 times
01: No limit
⎯
1170h
Starting frequency at
frequency pull-in restart
b011
R/W
00: Frequency at interruption
01: Max. frequency
02: Set frequency
⎯
10ADh
Electronic thermal level
b012
R/W
2nd electronic thermal level
b212
R/W
2000 to 10000
Set the rated current to 10000
0.01 [%]
1527h
10AEh
Electronic thermal
characteristics selection
b013
R/W
1528h
2nd electronic thermal
characteristics selection
b213
R/W
10B5h
Overload limit selection
b021
R/W
1529h
2nd overload limit selection
b221
R/W
10B6h
Overload limit level
b022
R/W
152Ah
2nd overload limit level
b222
R/W
10B7h
Overload limit parameter
b023
R/W
152Bh
2nd overload limit parameter
b223
R/W
10BBh
Overload limit source
selection
b028
R/W
00: Set values in b022
01: Input FV terminal
⎯
152Ch
2nd overload limit source
selection
b228
R/W
00: Set values in b222
01: Input FV terminal
⎯
1171h
Deceleration rate constant at
frequency pull-in restart
b029
R/W
1 to 30000
1172h
Frequency pull-in restart
level
b030
R/W
200 to 20000
Functions
4
Monitor or data range
00: Reduced torque characteristics 1
01: Constant torque characteristics
02: Reduced torque characteristics 2
00: Disabled
01: Enabled in acceleration/constant
speed operation
02: Enabled in constant speed operation
2000 to 15000
Set the rated current to 10000
1 to 300
4-99
Resolution
⎯
⎯
⎯
⎯
0.01 [%]
0.1 [s]
0.1 [s]
0.01 [%]