Download Untitled - Winsis.com
Transcript
www.tuv.com Page 53 of 112 Report No.: 16041780 001 IEC 60950-1 Clause Requirement + Test Result - Remark -- -- -- -- Verdict -- -- Supplementary information: The temperatures were measured under worst case normal mode defined in 1.2.2.1 and as described in sub-clause 1.6.2 and at voltages as described above. With a rated maximum ambient temperature of 45°C, the maximum temperature are calculated as follows: Winding components providing safety isolation: - Class B → Tmax = 120°C-10°C = 110°C (10°C decreased by thermocouple method) Operator touchable surface with maximum temperature rise of: 70°C For the other non-listed component temperature limit, refer to table 1.5.1. Test condition: a. 103.5V/50Hz, rated load. b. 126.5V/50Hz, rated load. c. 207V/50Hz, rated load. d. 253V/50Hz, rated load. e. 103.5V/50Hz, stand by. 4.5.5 TABLE: Ball pressure test of thermoplastic parts N/A Allowed impression diameter (mm) .................... : ≤ 2 mm Part Test temperature (°C) Impression diameter (mm) -- -- -Supplementary information: The bobbin material of transformer (T1 & T2) is phenolic, no test is needed. 4.7 TABLE: Resistance to fire Part N/A Manufacturer of material -- -- Type of material -- Thickness Flammability (mm) class -- -- Evidence -- Supplementary information: -- 5.1 P TABLE: touch current measurement Measured between: Measured (mA) Limit (mA) L. N → Enclosure 0.68 3.5 System ON, switch “e” opened. Output terminals 0.68 3.5 System ON, switch “e” opened. TRF No. IEC60950_1B Comments/conditions