www.tuv.com
Page 53 of 112
Report No.: 16041780 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
--
--
--
--
Verdict
--
--
Supplementary information:
The temperatures were measured under worst case normal mode defined in 1.2.2.1 and as described in
sub-clause 1.6.2 and at voltages as described above.
With a rated maximum ambient temperature of 45°C, the maximum temperature are calculated as follows:
Winding components providing safety isolation:
- Class B → Tmax = 120°C-10°C = 110°C (10°C decreased by thermocouple method)
Operator touchable surface with maximum temperature rise of: 70°C
For the other non-listed component temperature limit, refer to table 1.5.1.
Test condition:
a. 103.5V/50Hz, rated load.
b. 126.5V/50Hz, rated load.
c. 207V/50Hz, rated load.
d. 253V/50Hz, rated load.
e. 103.5V/50Hz, stand by.
4.5.5
TABLE: Ball pressure test of thermoplastic parts
N/A
Allowed impression diameter (mm) .................... : ≤ 2 mm
Part

Test temperature
(°C)
Impression
diameter (mm)
--
--
-Supplementary information:
The bobbin material of transformer (T1 & T2) is phenolic, no test is needed.
4.7
TABLE: Resistance to fire
Part
N/A
Manufacturer of
material
--
--
Type of material
--
Thickness Flammability
(mm)
class
--
--
Evidence
--
Supplementary information: --
5.1
P
TABLE: touch current measurement
Measured between:
Measured
(mA)
Limit
(mA)
L. N → Enclosure
0.68
3.5
System ON, switch “e” opened.
Output terminals
0.68
3.5
System ON, switch “e” opened.
TRF No. IEC60950_1B