Download Getting Started with Abaqus: Keywords Edition
Transcript
EXAMPLE: RESTARTING THE PIPE VIBRATION ANALYSIS 11.5.3 Running the analysis When running a simulation that will need to read data from a restart file, you must specify the root name of the restart file, without the .res extension, with the oldjob parameter on the Abaqus command line. Thus, use the following command to run this restart analysis: abaqus job=pipe-2 oldjob=pipe 11.5.4 Status file Again, check the status file as the job is running. When the analysis completes, the contents of the status file will look like SUMMARY OF JOB INFORMATION: STEP INC ATT SEVERE EQUIL TOTAL DISCON ITERS ITERS ITERS 3 1 1 0 1 1 3 2 1 0 1 1 3 3 1 0 1 1 3 4 1 0 1 1 3 5 1 0 1 1 3 6 1 0 1 1 4 1 1 0 6 0 TOTAL TIME/ FREQ 1.10 1.20 1.35 1.58 1.91 2.00 2.00 STEP TIME/LPF 0.100 0.200 0.350 0.575 0.913 1.00 1.00e-36 INC OF TIME/LPF DOF IF MONITOR RIKS 0.1000 0.1000 0.1500 0.2250 0.3375 0.08750 1.000e-36 This analysis starts at Step 3 since Steps 1 and 2 were completed in the previous analysis. There are now two output database (.odb) files associated with this simulation. Data for Steps 1 and 2 are in the file pipe.odb; data for Steps 3 and 4 are in the file pipe-2.odb. When plotting results in Abaqus/Viewer, you need to remember which results are stored in each file, and you need to ensure that Abaqus/Viewer is using the correct output database file. 11.5.5 Postprocessing the restart analysis results Start Abaqus/Viewer and specify that the output database file from the restart analysis should be used by giving the following command: abaqus viewer odb=pipe-2 Plotting the eigenmodes of the pipe Plot the same six eigenmode shapes of the pipe section for this simulation as were plotted in the previous analysis. The eigenmode shapes can be plotted using the procedures described for the original analysis. These eigenmodes and their natural frequencies are shown in Figure 11–12; again, the corresponding mode shapes lie in planes orthogonal to each other. 11–21 Abaqus ID: Printed on:
Related documents
Getting Started with Abaqus: Keywords Edition
FiberSim User Manual - The Information and Telecommunication
Getting Started with Abaqus: Interactive Edition
Reduced shock breakaway set screw for use with a surgical construct
2. A tutorial: Creating and analyzing a simple model
ABAQUS_TutorialCantilever Beam
FEM Practicals (Lent 2014-15)
PDF Report - Province of British Columbia
AIRWORTHINESS DIRECTIVE
DFG/TFG 16 - 50 A/B/C-S
A Guide to Static Reduction
Running ABAQUS 6.9 (PDF Format)