8.2 Resolution
8.2.1 How to calculate the Resolution
The TDC’s resolution RES is calculated using the divided calibration clock period tCAL and the
calibration values CAL and OFFSET:
RES = tCAL / (CAL – OFFSET) (A0)
8.2.2 Voltage Dependence
Table 8.4 shows the voltage dependence of the Normal-Resolution at normal conditions (typical
process, ambient temperature approx. 28°C), arised from averaging the measured resolution of several TDCs.
Supply Voltage
[V]
2,7
3,0
3,3
3,6
4,0
4,5
5,0
5,5
Normal-Resolution
[ps]
335
293
264
242
220
201
186
177
Table 8.4: Resolution Voltage Dependence (TA ≈ 28°C, typ.)
At Half-Resolution the specified values of Table 8.4 have to be doubled, at High-Resolution the
values have to be shortened by half and at Smart-Resolution they have to be shortened to the fourth
part.
8.2.3 Temperature Dependence
The Normal-Resolution increases by factors of approx. 0,6 ps/K at VDD = 3,3V and approx. 0,4
ps/K at 5V. At Half-Resolution the factors have to be doubled, at High-Resolution the factors have
to be shortened by half and at Smart-Resolution they have to be shortened to the fourth part.
TDC502RefManEngV26.doc
Version: 2.6
Author: AP