Download operating manual
Transcript
switching on/off OFF Press ON button 2 sec to start continuous laser mode. 2 sec adjusting measuring reference / tripod 1 beep on/off permanent / minimummaximum measuring 1 2 sec simultaneously 1 illumination on/off Device is turned OFF. memory (10 last displays) 10 last displays are displayed. 10 Distance is measured from the front of the device. 8.294 m 2 sec simultaneously clear 1x 2 2x Undo last action. Distance is measured from the tripod thread permanently. Leave actual function, go to default operation mode message code 1 2 The next measurement is added to the previous one. The next measurement is subtracted from the previous one. 2 3 12.847 m Distance is measured from the rear of the device (standard setting). 2 1 3 Aim active laser target. 1 2 volume 3 2 1 5 The result is shown in the main line and the measured value above. Partial Measurements: Press + or after starting the first measurement. Measure and add or subtract distances. Finish with DIST. Measure 2nd length. 4 5 5 4 Aim laser at rectangular point 7 The result is shown in the main line and the measured value above. 7 8.294 m Press 2 sec AREA / VOLUME key to get 2nd results. 3 Press 2 sec AREA / VOLUME key to get 2nd results. Memory is completely deleted. stake out pythagoras (partial Height) 2 1 5 4 Aim laser at lower point. 2 sec simultaneously 3 1 Aim laser at 2nd point. 3 6 Aim laser at rectangular point. The result is shown in the main line and the measured distance above. The result is shown in the main line and the measured distance above. Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maximum measurement. Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maximum measurement. 7 2.602 m 2 Adjust Value Aim Laser at upper point. 6 2 sec The value from the main line can be used for further calculations. delete memory Stops permanent / minimum- maximum measuring. 2 1 . 3 Aim laser at upper point. Aim laser at second target point.. 6 3 pythagoras (3-point) Aim laser at first target point.. Aim laser at first target point. 4 3 8.294 m The minimum and maximum distance measured is displayed (min,max.). The last value measured is displayed in the main line. 8.532 m Navigates through 10 last displays. 10 Used to measure room diagonals (maximum values) or horizontal distance (minimum values) measuring single distance If the message :inFo” appears with a number, observe the instructions in section “message Codes”. Example at left. area 2 7.332 m The result is shown in the main line and the measured value above. This process can be repeated as required. The same process can be used for adding or subtracting areas or volumes. 3 max. min. add / subtract 4 Approve value and start measurement. Move device slowly along the stakeout line. The distance to the next stake-out point is displayed. When approaching a stake out point to less than 0.1 m the instrument starts to beep. The function can be stopped by pressing the CLEAR/OFF button.