Download X Series User Manual
Transcript
Chapter 7 Counters Table 7-1. Counter Timing Measurements Implicit Timing Support Sample Clocked Timing Support Buffered Edge Count No Yes Buffered Pulse Width Yes Yes Buffered Pulse Yes Yes Buffered Semi-Period Yes No Buffered Frequency Yes Yes Buffered Period Yes Yes Buffered Position No Yes Buffered Two-Signal Edge Separation Yes Yes Measurement Counter Input Applications The following sections list the various counter input applications available on X Series devices: • Counting Edges • Pulse-Width Measurement • Pulse Measurement • Semi-Period Measurement • Frequency Measurement • Period Measurement • Position Measurement • Two-Signal Edge-Separation Measurement Counting Edges In edge counting applications, the counter counts edges on its Source after the counter is armed. You can configure the counter to count rising or falling edges on its Source input. You also can control the direction of counting (up or down), as described in the Controlling the Direction of Counting section. The counter values can be read on demand or with a sample clock. © National Instruments Corporation 7-3 X Series User Manual