Configuring Battery Characteristics and Battery Charging
Table 3-3 Custom Battery Menu Values
Setting




Values
Default
Description
12V: 10.0–16.0V
24V: 20.0–32.0V
36V: 30.0–48.0V
48V: 40.0–64.0V
60V: 50.0–72.0V
13.5V
27.0V
40.5V
54.0V
67.5V
Sets the float voltage for a
custom battery type.
12V: -45–0mV/degC
24V: -90–0mV/degC
36V: -135–0mV/degC
48V: -180–0mV/degC
60V: -225–0mV/degC
-27mV
-54mV
-81mV
-108mV
-135mV
Battery temperature
compensation for a custom
battery type. This setting is
the reference that the BTS
uses to adjust the charging
voltage when the temperature
falls above or below 25 °C.
See “Battery Temperature
Compensation”.
See “Default Battery Charging Settings” on page A–2 for default settings for
standard battery types.
CAUTION: Equipment damage
The XW SCC is incapable of determining battery type and cannot warn against or
disallow incorrect settings. The settings for bulk, absorption, float and equalization charge
must be checked carefully against the battery specifications. Incorrect settings may
damage the battery or shorten battery life.
975-0400-01-01