Download CLAS110NGFCY-BR User Manual
Transcript
INSTALLATION Check the appliance is gas sound when you have finished. Electrical Connection If there is an electrical fault carry out the following checks: WARNING: THIS COOKER MUST BE EARTHED. nn Earth Continuity Check The cooker must be disconnected from the power supply. All external wiring must comply with the local regulations for the Electrical Equipment of Buildings. Connection to the electrical supply can be made with either a plug and socket or be permanently wired via a double-pole switch, having a contact separation of at least 3 mm in all poles. Using an multimeter or ohmmeter to check the resistance, test the leads from any of the cooker’s earth points (e.g. inside electric box cover) – to the earth pin on the cooker’s plug – resistance should be less than 1 Ω. If it is not, check all the earth wires for continuity. Current Operated Earth Leakage Breakers Check that all contacts are clean and tight. Recheck. If the resistance is still greater than 1 Ω there may be a problem, so consult a qualified electrical engineer. The combined use of your cooker and other domestic appliances may cause nuisance tripping, so we recommend that the cooker is protected on an individual RCD (Residual Current Device) or RCBO (Residual Current Breaker with Overload). Polarity Check The cooker must be connected to the power supply. Your meter should be set on 300 V ac scale. IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED ELECTRICIAN. Test at the cooker terminal block: The appliance is supplied with a 250 V high temperature PVC (85 °C) 3-core cable, 0.75 mm2, 2 m long. If a replacement cable is fitted it must be to this specification. The cooker may possibly be supplied with either a moulded or rewirable plug fitted. Should the plug (where supplied) not fit the socket in your home, it should be removed and replaced with a suitable plug. Note: If a moulded plug is fitted which is not suitable, it must be cut off and disposed of properly. To avoid the risk of electrocution, the moulded plug must not be left where children might find it and plug it into a supply socket. It must not be used for any other appliance. Test leads from A to N. The meter should read about 240 V ac. 2. Test leads from A to E. The meter should read about 240 V ac. 3. Test leads from N to E. The meter should read about 0-15 V ac. If the readings are different from these values there is an electrical fault. Rectify any fault and repeat the test. If necessary repeat the test at the supply system socket/spur – if the fault also occurs at this stage then there is a house system fault that requires attention by the Electrical Authority. Any new plug fitted MUST have insulated terminals. The customer should be warned NOT to use the appliance until this examination has been carried out. The wires should be connected into the terminals of your plug as follows: Earth: 1. To the terminal marked E, or coloured GREEN or GREEN/YELLOW. Neutral: To the terminal marked N, or coloured BLACK or BLUE. Active: To the terminal marked A, or coloured RED or BROWN. When wiring the plug make sure that all strands of wire are retained in each terminal. The flexible mains lead, plug and socket must not be directly exposed to flue products or be in contact with hot surfaces. The lead must not be trapped or pulled taut when the appliance is pushed into position. Plug in the appliance. Turn on the electricity supply. 26