Download Contents Micropulse Transducer

Transcript
Micropulse
Transducer
Contents
P.2
P.4
P.6
P.8
P.10
P.12
P.14
P.16
General data
Analog
interface
Digital
pulse interface
SSD
interface
CANopen
interface
Floating
magnets
Captive
magnets
Connectors
P
BTL
General
data
Analog
interface
Digital
pulse
interface
SSD
interface
CANopen
interface
Floating
magnets
Captive
magnets
Connectors
Processors
see page
A.1...
P.1
Micropulse
Transducer
General data
Profile series
Micropulse
Transducer
Series
Magnets starting P.12
Non-contact
Balluff Micropulse
transducer with
transducers in the Profile
floating magnet
housing, with their
mechanical design, the high
protection rating, and
their ease of installation,
are an alternative to linear
transducers such as
potentiometers, glass scales,
and LVDTs. The linear sensing
element is protected in an
aluminum extrusion.
The measuring point along
the sensing element
(waveguide) is indicated by a
passive marker (magnet),
which needs no power.
– non-contact detection of
the actual position
– IP 67, insensitive to
contamination
– wear-free
– insensitive to shock and
vibration
– absolute output signal
– resolution up to 0.002 mm
(depending on processor
used)
– direct signal processing or
through processor cards
for interfacing with any
control system or standalone operation
floating
captive
BTL5 Profile
BTL5-P-3800-2 or BTL5-P-5500-2 or BTL5-P-4500-2
BTL5-F-2814-1S or BTL5-N-2814-1S or BTL5-M-2814-1S
P
BTL
Non-contact transducer with floating magnet
nominal stroke
physical length
General
data
Non-contact transducer with captive magnet
nominal stroke
Analog
interface
Digital
pulse
interface
Non-contact
transducer with
captive magnet
SSD
interface
CANopen
interface
Floating
magnets
Captive
magnets
physical length
Connectors
Ordering code
BTL5-...-M_ _ _ _ -P-S 32
Shock loading
Vibration
Polarity reversal protected
Overvoltage protection
Dielectric strength
Enclosure rating per IEC 529
Housing material
Housing attachment
Connection type
Recommended connector, see P.16
100 g/11 ms per IEC 68-2-27
12 g, 10...2000 Hz per IEC 68-2-6
yes
Transzorb protection diodes
500 V (GND to housing)
IP 67 (when BKS-S32/33 is installed)
anodized aluminum
clamping feet
connector
BKS-S 32M/BKS-S 32M-C/BKS-S 33M
Emissions tests:
RF emission
EN 55 011 Group 1, Class A
Noise immunity tests:
Static electricity (ESD)
Electromagnetic fields (RFI)
Fast transients (BURST)
Line-carried noise,
induced by high-frequency fields
▼
Standard nominal strokes [mm]
P.2
General data
Profile series
IEC 1000-4-2 Severity Level 3
IEC 1000-4-3 Severity Level 3
IEC 1000-4-4 Severity Level 4
IEC 1000-4-6 Severity Level 3
0050,
0400,
0950,
1800,
0100,
0450,
1000,
1900,
0130,
0500,
1100,
2000,
Included:
– Transducer in Profile housing (see starting P.4 for interface options)
– Mounting clamps with isolation bushings and screws
– User's manual
0150,
0550,
1200,
2250,
0175,
0600,
1250,
2500,
0200,
0650,
1300,
2750,
0225,
0700,
1400,
3000,
0250,
0750,
1500,
3250,
Processors
See page
A.1...
0300,
0800,
1600,
3500,
0350,
0850,
1700,
3550,
0360,
0900,
1750
3750
Please order separately:
Magnet P.12
Connector P.16
P.3
Micropulse
Transducer
Analog interface
Profile series
Micropulse
Transducer
Series
Output signal
Transducer interface
Input interface
BTL5 Profile
analog
A
analog
BTL5 Profile
analog
E
analog
Analog interface
Profile series
BTL5 Profile
analog
C
analog
BTL5 Profile
analog
G
analog
The analog outputs of the
Profile series are potentialfree with respect to the input
voltage. The isolation is
accomplished galvanically by
means of a DC-DC converter.
P
BTL
BTL transducers with analog
outputs are available in the
ranges of 0...10 V, 4...20 mA,
0...20 mA and –10...10 V
with rising or falling signal.
Ordering code
Output
Output voltage
Output current
Load current
max. ripple.
Load resistance
System resolution
BTL5-A11-M_ _ _ _-P-S 32
BTL5-E1_-M_ _ _ _-P-S 32
BTL5-C1_-M_ _ _ _-P-S 32
BTL5-G11-M_ _ _ _-P-S 32
General
data
potential-free
0...10 V and 10...0 V
potential-free
potential-free
potential-free
–10...10 V and 10...–10 V
Analog
interface
4...20 mA or 20...4 mA
0...20 mA or 20...0 mA
max. 10 mA
≤ 5 mV
£ 0.1 mV
≤ 500 Ohm
£ 0.2 µA
Voltage output
Current output
Shock loading
Vibration
Traverse velocity of magnet
Operating voltage
Current draw
Polarity reversal protected
Overvoltage protection
Dielectric constant
Operating temperature
Storage temperature
Pin assignments
Output signals
Supply voltage
Pin
1
2
3
5
6
7
8
£ 0.1 mV
≤ 4 µm
≤ 6 µm (hysteresis + resolution)
fSTANDARD = 1 kHz
±100 µm to 500 mm stroke
±0.02 % 501...3750 mm stroke
[150 µV/°C + (5 ppm/°C × P × U/L)] × ∆T
[0.6 µA/°C + (10 ppm/°C × P × I/L)] × ∆T
100 g/11 ms per IEC 68-2-27
12 g, 10...2000 Hz per IEC 68-2-6
any
24 V DC ±20 %
≤ 150 mA
yes
Transzorb protection diodes
500 V (Ground to housing)
–40...+85 °C
–40...+100 °C
Hysteresis
Repeatability
Internal sampling frequency
max. non-linearity
Temperature coefficient
≤ 500 Ohm
£ 0.2 µA
max. 10 mA
≤ 5 mV
BTL5-A11...
Color
YE
GY
PK
GN
BU
BN
WH
0 V output
10...0 V
0...10 V
GND
+24 V DC
(GND)
BTL5-E10... BTL5-E17...
4...20 mA
20...4 mA
0 V output
10...0 V
0...10 V
GND
+24 V DC
(GND)
BTL5-C10... BTL5-C17...
0...20 mA
20...0 mA
0 V output
10...0 V
0...10 V
GND
+24 V DC
(GND)
P.4
▼
▼
▼
Please order separately:
Magnet page P.12
Connector page P. 16
Please enter code for output
signal and nominal stroke in
ordering code!
Preferred A-interface models
BTL5-A11-M_ _ _ _-P-S 32
marked in blue are available
from stock.
SSD
interface
CANopen
interface
Floating
magnets
Captive
magnets
Connectors
BTL5-G11...
0 V output
10...–10 V
–10 ... 10V
GND
+24 V DC
(GND)
Connect shield to housing.
Included:
– Transducer in Profile housing
– Mounting clamps with isolation bushings and screws
– User's manual
Digital
pulseinterface
Processors
see page
A.1...
Ordering example:
BTL5-A1_-M_ _ _ _-P-S 32
Output signal
1
0
7
increasing
and decreasing
(for A and G)
increasing
decreasing
(for C and E)
Standard
nominal strokes [mm]
0050, 0100, 0130, 0150, 0175, 0200, 0225,
0300, 0350, 0360, 0400, 0450, 0500, 0550,
0650, 0700, 0750, 0800, 0850, 0900, 0950,
1100, 1200, 1250, 1300, 1400, 1500, 1600,
1750, 1800, 1900, 2000, 2250, 2500, 2750,
3250, 3500, 3550, 3750
0250,
0600,
1000,
1700,
3000,
P.5
Micropulse
Transducer
Digital pulse interface
Profile series
Micropulse
Transducer
Series
Transducer interface
User interface
P Interface
M Interface
Compatible with BTA
processors and various
OEM controls, e.g., Siemens, Parker, Mitsubishi,
Schleicher, B & R, Schiele,
Esitron, Philips, Fanuc.
Reliable signal transmission,
even over cable lengths
up to 500 m between BTA
and BTL, is assured by the
especially noise-immune
RS485 differential drivers
and receivers. Noise signals
are effectively suppressed.
The I and M interfaces are
control-specific interface
variations.
Digital pulse interface
Profile series
BTL5 Profile
BTL5 Profile
BTL5 Profile
pulse P
pulse P
pulse M
pulse M
pulse I
pulse I
P
BTL
I Interface
Used for parallel operation
of multiple transducers,
for example up to 4 transducers can be controlled by
a single BTA-M/PMT card
(see page A.2).
Ordering code
System resolution
Repeatability
Resolution
Hysteresis
Internal sampling rate
max. non-linearity
Input
Output
Input
Output
Supply voltage
Pin
1
2
3
5
6
7
8
BTL5-I1-M_ _ _ _-P-S 32
Color
YE
GY
PK
GN
BU
BN
WH
Digital
pulseinterface
SSD
interface
CANopen
interface
Floating
magnets
Captive
magnets
Connectors
BTL5-M1-M...
INIT
START/STOP
INIT
START/STOP
GND
+24 V DC
(GND)
BTL5-P1-M...
INIT
START/STOP
INIT
START/STOP
GND
+24 V DC
(GND)
General
data
Analog
interface
processing-dependent
≤ 6 µm (Hysteresis + Resolution)
≤ 2 µm
≤ 4 µm
fSTANDARD = 1 kHz = ≤ 1400 mm
±100 µm to 500 mm nominal stroke
±0.02 % 501...3750 mm nominal stroke
(6 µm ±5 ppm × L)/°C
any
24 V DC ±20 %
≤ 100 mA
–40...+85 °C
–40...+100 °C
Temperature coefficient of overall system
Traverse velocity of magnet
Operating voltage
Current draw
Operating temperature
Storage temperature
Pin assignments
Input/output signals
BTL5-M1-M_ _ _ _-P-S 32
BTL5-P1-M_ _ _ _-P-S 32
BTL5-I1-M...
INIT
START/STOP
INIT
START/STOP
GND
+24 V DC
(GND)
Please order separately:
Magnet page P.12
Connector P.16
P.6
▼
Included:
– Transducer in Profile housing
– Mounting clamps with isolation bushings and screws
– User's manual
Please enter code
for nominal stroke
in ordering code!
▼
▼
Shield connected to housing
Preferred P-interface models
BTL5-P1-M_ _ _ _-P-S 32
marked in blue are available
from stock.
Ordering example:
BTL5-P1-M_ _ _ _-P-S 32
Standard
nominal strokes [mm]
0050,
0300,
0650,
1100,
1750,
3250,
0100, 0130, 0150,
0350, 0360, 0400,
0700, 0750, 0800,
1200, 1250, 1300,
1800, 1900, 2000,
3500, 3550, 3750
0175, 0200, 0225,
0450, 0500, 0550,
0850, 0900, 0950,
1400, 1500, 1600,
2250, 2500, 2750,
0250,
0600,
1000,
1700,
3000,
Processors
see page
A.1...
P.7
Micropulse
Transducer
SSD interface
Profile series
Micropulse
Transducer
BTL5 Profile
synchronous-serial
S
synchronous-serial
Series
Output signal
Transducer interface
User interface
SSD interface
Synchronous serial data
transmission for controls
made by Siemens,
Schleicher, B & R, Mitsubishi,
Schiele, Parker, Esitron,
Philips, Fanuc etc. as well as
for Balluff BDD-AM10-1-SSD
display/controller with two
relay outputs.
SSD-Interface
Profile series
Reliable signal transmission
even over cable lengths of up
to 400 m between control
and BTL transducer is
assured by the especially
noise-immune RS485/422
differential line drivers and
receivers. Any noise signals
are effectively suppressed.
P
BTL
Pulse sequence
Pulse (+)
SLoad
SIGN
Data (+)
+Clk
YE
–Clk
PK
+Data
GY
–Data
GN
GND
BU
+24 V
BN
BTL5-S1...
transducer
BTL5-S1_ _-M_ _ _ _-P-S 32
General
data
≤ 2 Digit (Hysteresis + system resolution)
5, 10, 20 or 40 µm
≤ 1 digit
fSTANDARD = 2 kHz
±30 µm for 5 and 10 µm resolution or ≤ ±2 LSB
(6 µm ±5 ppm × L) /°C
100 g/11 ms per IEC 68-2-27
12 g, 10...2000 Hz per IEC 68-2-6
any
24 V DC ±20 %
≤ 80 mA
–20...+85 °C
–20...+100 °C
Analog
interface
Ordering code
Repeatability
System resolution depending on version (LSB)
Hysteresis
Internal sampling rate
max. non-linearity
Temperature coefficient of overall system
Shock loading
Vibration
Traverse velocity of magnet
Operating voltage
Current draw
Operating temperature
Storage temperature
Processor
or
control
BTL5-S1... with processor/controller, wiring example
Pin assignments
Control and
data signals
▼
Supply
voltage (external)
Please enter code
for system resolution
and nominal stroke
in ordering code!
Pin
1
2
3
5
6
7
8
Color
YE
GY
PK
GN
BU
BN
WH
SSD
interface
CANopeninterface
Floating
magnets
Captive
magnets
Connectors
+Clk
+Data
–Clk
–Data
GND
+24 V DC
must remain unconnected
Ordering example:
BTL5-S1_ _-M_ _ _ _-P-S 32
Systemresolution
Codierung
0
1
6
7
▼
Digital
pulseinterface
Binary increasing (24 bits)
Gray increasing (24 bits)
Binary increasing (25 bits)
Gray increasing (25 bits)
Included:
– Transducer in Profile housing
– Mounting clamps with isolation bushings and screws
– User's manual
2
3
4
5
5
10
20
40
µm
µm
µm
µm
Standard
nominal strokes [mm]
0050, 0100, 0130, 0150,
0175, 0200, 0225, 0250,
0300, 0350, 0360, 0400,
0450, 0500, 0550, 0600,
0650, 0700, 0750, 0800,
0850, 0900, 0950, 1000,
1100, 1200, 1250, 1300,
1400, 1500, 1600, 1700,
1750, 1800, 1900, 2000,
2250, 2500, 2750, 3000,
3250, 3500, 3550, 3750
Processors
see page
A.1...
Please order separately:
Magnet page P.12
Connector P.16
P.8
P.9
Micropulse
Transducer
CANopen-Interface
Profile series
Micropulse
Transducer
Series
Output signal
Transducer interface
User interface
CANopen interface
Position and velocity are
represented in a Float
The CANopen interface of
32 number format per ICCC
the Micropulse transducer is 754-1985. They are however
compatible with CANopen
also available as integer raw
per CiA Standard DS-301
values with resolution fixed at
Rev. 3.0, with CAL, and Layer 5 µm or 0.25 µm/s.
2 CAN networks.
Synchronisation Object
Process Data Object
(SYNC)
(PDO)
Serves as a net-wide trigger
Micropulse transducers send for synchronizing all network
their position information
participants. When the
optionally in one or two
SYNC object is received, all
PDOs with 8 bytes of data
Micropulse transducers
each. The contents of the
active on the bus store their
PDOs is free configurable.
current position and velocity
You can send:
information and then send it
sequentially to the control.
– the current position of the This assures timemagnet with resolution
synchronous capture of the
selectable for 5, 10, 20
measured values.
and 100 µm
– the current velocity of the
magnet with resolution
selectable for 0.25, 0.5
und 1 mm/s
– the current status of
four free programmable
setpoints (cams)
Emergency Object
Service Data Object (SDO)
This object is sent with the
highest priority. It is used
to report faults or can
also be used for high-priority
transmission of setpoint
status changes.
Service Data Objects transmit the parameters for the
transducer configuration. The
transducer configuration may
be carried out on the BUS by
the controller, or offline using
a PC with a configuration tool
which runs under Windows.
The configuration is stored in
the transducer in a nonvolatile memory.
BTL5 Profile
CANopen
H
CANopen
P
BTL
Termination
Node n
CANopen-Interface
Repeatability
System resolution
Position
configurable
Velocity
Hysteresis
Internal sampling rate
max. non-linearity
Temperature coefficient of overall system
Traverse velocity of magnet
Operating voltage
Current draw
Operating temperature
Storage temperature
Transducer
BTL5-H10...
Node m
Controller/
Master
Range of functions:
– Menu-driven configuration
of all manufacturer-specific
module parameters and
module-specific communications parameters.
Checking entries for valid
values.
– LMT data, consisting of:
Manufacturer's name
(7 characters), Product
name (7 characters) and
Serial no. (14 digits).
The configuration entered is
sent to the BTL module and
there stored in the object
directory. At the same time
the object directory is stored
in the configuration tool.
The configuration parameters, which are stored in
a database, can for example
be copied from one module
to another (e.g., when
replacing modules).
CAN Bus Interface on PC:
1. CANdy*
Connects to the parallel
interface
2. PCI-302*
Plug-in card with bus
analyzer function
*Products of Steinbeis Transferzentrum Prozess-automatisierung,
Weingarten.
Supply
voltage (external)
Pin
1
2
3
5
8
6
7
Using the CANopen interface
and cable lengths up to
2500 m, the signal is sent at a
length-dependent baud rate
to the control. The high noise
immunity of the connection is
achieved using differential
drivers and by the data monitoring scheme implemented in
the data protocol.
▼
is a user-friendly software
for parameterizing the BTL
and for mapping the BTL
data in the PDOs. It can also
be used for test purposes
or for reading out the BTL
parameters or the LMT
– Node-ID and baud rate.
– Setting the working range
and cam switchpoints.
The parameters can also
be configured in teach-in
mode, whereby the resp.
current position is read in
by the configuration tool.
– Operating mode selection
for sending and preparing
BTL data:
continuous,
on-demand,
event-dependent
– Arrangement of the BTL
data (position, velocity and
status) in the data field of
the PDO (Object Mapping).
Pin assignments
Control and
data signals
< 25
1000
General
data
potential-free
≤ 2 digit (Hysteresis + system resolution)
5, 10, 20 and 100 µm
0.25 mm/s, 0.5 mm/s, 1 mm/s
≤ 1 digit
fSTANDARD = 2 kHz
±30 µm at 5 µm resolution
(6 µm ±5 ppm × L)/°C
any
24 V DC ±20 %
≤ 100 mA
–20...+85 °C
–20...+100 °C
Analog
interface
< 50
800
Color
YE
GY
PK
GN
WH
BU
BN
▼
Termination
format per ICCC 754-1985.
These are also however
available as integer raw
values with a resolution of
5 µm or 0.25 µm.
BTL5-H1_ _-M_ _ _ _-P-S 32
Ordering code
Cable length [m] per CiA DS 301
Baud rate [kBaud] per CiA DS 301
BTL Configuration Tool
CANopen
CANopen Interface
Profile series
<100
500
< 250
250
< 500 < 1000 < 1250
125
100
50
Digital
pulseinterface
SSDinterface
CANopen
interface
Floating
magnets
Captive
magnets
Connectors
< 2500
20/10
n.c.
CAN_H
n.c.
CAN_L
CAN_GND
0 V (GND)
+24 V DC (do not use 5 V for CAN driver)
Please enter code for software configuration, baud rate
and nominal stroke in the ordering code!
Ordering example:
BTL5-H1_ _-M_ _ _ _-P-S 32
SoftwareConfiguration
0
Included:
– Transducer in Profile housing
– Mounting clamps
with isolation bushings and screws
– User's manual
1
Please order separately:
Magnet page P.12
Connector P.16
3
2
1 × position and
1 × velocity
OV per DS 301
1 × position and
1 × velocity
OV nach DS 406
2 × position and
2 × velocity
OV per DS 406
4 × position
OV per DS 406
Baud
Rate
0
1
2
3
4
5
6
7
1
800
500
250
125
100
50
20
Standard
nominal strokes [mm]
MBaud
kBaud
kBaud
kBaud
kBaud
kBaud
kBaud
kBaud
0050,
0175,
0300,
0450,
0650,
0850,
1100,
1400,
1750,
2250,
3250,
0100, 0130, 0150,
0200, 0225, 0250,
0350, 0360, 0400,
0500, 0550, 0600,
0700, 0750, 0800,
0900, 0950, 1000,
1200, 1250, 1300,
1500, 1600, 1700,
1800, 1900, 2000,
2500, 2750, 3000,
3500, 3550, 3750
Processors
see page
A.1...
O V = Object Directory
P.10
P.11
Micropulse
Transducer
Floating magnets
Profile series
Name
for series
Type
Balluff magnets are available
in floating or captive
configuration. All BTL5
magnets can be used with
any Balluff Micropulse
transducer. The optimum
resolution and repeatability
are provided by the
BTL5-F/M/N-2814 magnet.
Magnet
BTL5 Profile
Magnet
BTL5 Profile
Magnet
BTL5 Profile
floating
floating
floating
P
BTL
Ø4.2
20
D
50 +4
9
14
38
28
C
1
Lateral offset:
C = ±2 mm
Vertical distance:
D = 0.1...4 mm
50
68
Lateral offset:
C = ±15 mm
Vertical distance:
D = 5...15 mm
Lateral offset:
C = ±2 mm
Vertical distance:
D = 0.1...2 mm
PL0001
The BTL5-P-3800 magnet
can be operated at a vertical
distance of 0...4 mm and the
BTL5-P-5500 at a distance
of 5...15 mm from the upper
surface of the housing
extrusion. The BTL5-P-4500
is an electromagnet which
requires a supply voltage of
24 V and can be turned
on and off with this voltage.
This makes it possible to
implement multiplex
operation using multiple
magnets on a single
transducer.
Floating magnets
Profile series
Micropulse
Transducer
Ordering code
Material
Housing
Slide surface
Weight
Traverse velocity of magnet
Operating voltage
Current draw
Operating temperature
Storage temperature
Included
Accessories
(please order separately)
BTL5-P-3800-2
BTL5-P-5500-2
BTL5-P-4500-1
General
data
plastic
plastic
ca. 12 g
any
plastic
plastic
ca. 40 g
any
plastic
plastic
ca. 90 g
any
24 V DC
100 mA
–40 ... +85 °C
–40 ... + 100 °C
magnet
Analog
interface
–40 ... + 85 °C
–40 ... + 100 °C
magnet
2 mounting screws DIN 84 M4 × 35-A2
with washers and nuts
–40 ... + 85 °C
–40 ... + 100 °C
magnet
connectors straight BKS-S 19-1-_ _
connectors right-angle BKS-S 20-1-_ _
Digital
pulse
interface
SSD
interface
CANopen
interface
Floating
magnets
Captive
magnets
Connectors
Please indicate cable length in ordering code!
03, 05, 10, 15
= PVC-Cable 3 m, 5 m, 10 m or 15 m
PU-03, PU-05, PU-10, PU-15
= PuFlex-Cable 3 m, 5 m, 10 m or 15 m
Processors
see page
A.1...
P.12
P.13
Micropulse
Transducer
Captive magnets
Profile series
Name
for series
Type
Captive magnets,
Control arm
Profile series
Micropulse
Transducer
Magnet
BTL5 Profile
Magnet
BTL5 Profile
Magnet
BTL5 Profile
captive
captive
captive
Name
for
Control arm (including swivel eye)
Magnet BTL5-F-2814-1S
P
BTL
nominal length
Material
Housing
Slide surface
24
66.4
±18º
30.4
M5
40
1
60
15
51
59.5
28
50
68
adjustment range –5 mm
PL0004
PL0006
50
68
BTL5-M-2814-1S
BTL5-N-2814-1S
BTL5-F-2814-1S
anodized aluminum
plastic
ca. 32 g
any
–40...+85 °C
–40 ... + 100 °C
anodized aluminum
plastic
ca. 35 g
any
–40...+ 85 °C
–40 ... + 100 °C
plastic
plastic
ca. 28 g
any
–40...+85 °C
–40 ... + 100 °C
BTL2-GS10-_ _ _ _-A
General
data
Material
aluminum
Analog
interface
Weight
ca. 150 g/m
Digital
pulse
interface
Ordering code
SSD
interface
▼
Weight
Traverse velocity of magnet
Operating temperature
Storage temperature
20
1
57
48.5
1
PL0005
50
68
Ordering code
41
M5x10
23.5
20
12.5
21
41
28
18
M5
28
18
CANopen
interface
Please enter code for nominal
length in ordering code!
Floating
magnets
Captive
magnets
Ordering example:
BTL2-GS10-_ _ _ _-A
Connectors
Standard
nominal length [mm]
0075, 0100, 0125, 0150, 0200, 0250, 0350, 0400,
0450, 0500, 0600, 0800, 1000, 1500, 2000
Swivel eye
part no. 714619
Processors
see page
A.1...
P.14
P.15
Micropulse
Transducer
Connectors
Profile series
Connector
for series
Version
Ordering code
Crimp contacts
Solder connection
Housing material
Contact
Contact surface
Cable strain relief
Min. cable diameter
Cable
No. of leads × cross-section/AWG
Enclosure rating per IEC 529
BKS-S 32M
BTL5 Profile
BKS-S 32M-C
BTL5 Profile
BKS-S 33M
BTL5 Profile
straight
straight
right-angle
BKS-S 32M-_ _
BKS-S 32M-C-_ _
BKS-S 33M-_ _
max. 0.5 mm² (AWG 20)
max. 0.75 mm2 (AWG 18)
nickel plated brass
CuSn
0.8 µm Au
PG 9
6...8 mm
Lif2Y-FC-11Y- 0
7 × 0.25mm² (AWG 24)
IP 67 (when fully attached)
nickel plated brass
CuSn
0.8 µm Au
PG 9
6...8 mm
Lif2Y-FC-11Y- 0
7 × 0.25mm² (AWG 24)
IP 65 (when fully attached)
max. 0.75 mm2 (AWG 18)
ZnAlCu1, nickel plated
CuSn
0.8 µm Au
PG 9
6...8 mm
Lif2Y-FC-11Y- 0
7 × 0.25mm² (AWG 24)
IP 67 (when fully attached)
Please indicate cable length in ordering code!
Code 00 for unassembled
(use shielded cable).
Code 05, 10, 15, 20, 25, 30 m
for finished assembled cable
Pin assignments
View of
female solder side
Pin
1
2
3
5
6
7
8
Color
YE
GY
PK
GN
BU
BN
WH
Mounting clamps with
isolation bushings and screws
are included with transducer
P.16