Download Display
Transcript
4.2.11 Using the Reference Pulse Inhibit Function (INHIBIT) This function causes the Servo drive to stop counting input reference pulses in position control mode. While this function is being used, the motor remains in servo locked (clamped) status. The /P-CON signal is used to enable or prohibit this function. How to Use Reference Pulse Inhibit Function: INHIBIT To use the INHIBIT function, set parameters as follows. Setting Para. No. Description Pn041 Control Mode Selection 0 0 13 Pn041 11 Default range Control mode Position control reference pulse <->pulse prohibited position control with pulse inhibit function · /P-CON 1CN-11 signal is used to enable or prohibit the INHIBIT function. 1CN-11 ON pulse inhibit enabled OFF pulse inhibit prohibited Relationship between INHIBIT Signal and Reference Pulse 62 Function For speed/torque and position control